					       Solutions for Ambulatory
       Blood Pressure Monitoring
       Peripherals for Ambulatory Blood Pressure Monitors

       Doctor Pro 3 Blood Pressure Analysis Software
              TM-2480 Printer Terminal




0366




                                  Technology You Can Trust


            http://www.aandd.jp
More Precise Treatment for Hypertensive Patients!
Skyrocketing healthcare costs and an increase in hypertensive/borderline patients demand quicker and more
accurate diagnoses. Physicians require devices that guarantee they can meet these changing patient needs. For over
20 years, A&D has led the field in ambulatory blood pressure monitoring by designing and providing products to
help healthcare providers save time and perform diagnosis accurately in order to effectively treat hypertension. Our
devices not only benefit healthcare professionals, but also patients because they provide information necessary to
prescribe effective anti-hypertensive drugs.

Today, A&D is proud to introduce two solutions for general/family practioners: the Doctor Pro 3 Blood Pressure
Analysis Software and the TM-2480 Printer Terminal. Doctor Pro 3 analysis software is designed to diagnose patient
data collected by the TM-2430 Ambulatory BP Monitor or the UA-767PC Personal BP Monitor on a Windows™
computer. This software stores patient data on a database, making it easier for healthcare professionals to keep
track of multiple measurement records for a single patient and diagnose the patients’ condition faster than ever.
The TM-2480 Printer Terminal is designed to make optimal use of our TM-2430 ABPM and is ideally suited for use
in a doctor’s office – a PC connection is not required. By itself, this terminal provides a quick, accurate method for
healthcare professionals to perform basic diagnoses. Use it together with our Doctor Pro 3 Blood Pressure Analysis
Software, and healthcare professionals are able to easily record blood pressure data for long-term patient analysis.




TM-2480 Printer Terminal                                                 Doctor Pro 3 Blood Pressure Analysis Software
This unique printer terminal can be connected to the TM-2430             Our new blood pressure analysis software is the link between
ABP monitor or our UA-767PC Home-Use BP monitor with one                 your A&D TM-2430 ABP Monitor or UA-767PC Personal BP
cable. What makes this terminal so special is its ability to print out   monitor and your Windows™ computer. Not only does it provide
results in either a table format or as simple, easy-to-read graphs       data storage, patient information, summary reports and graphing
for diagnostic purposes. Healthcare professionals can also use the       capabilities, it also controls the TM-2430 monitor, and sets
printer’s keyboard to input the desired settings on the TM-2430          calendar and measurement intervals. This software prints out all
ABP monitor (date/time, calendar and measurement intervals). In          data (including graphs) on any PC printer.
addition, the TM-2480 operates with an AC or batteries, so users
can print out and read the blood pressure data even when no              Features
computer is available!                                                   ■ Various Analysis
                                                                           1. Statistical Analysis
Features                                                                      Statistical data may be viewed in full, partial, sleep and awake
1. Use either with the TM-2430 ABP monitor or our UA-767PC                    periods by switching between clearly labeled tabs.
   personal monitor.
                                                                           2. Graphical Data
2. Print out blood pressure measurement results easily in both                Graphic position, a scale for histogram, correlation plots and
   table and graph format.
                                                                              systolic/diastolic, mean arterial blood pressure and pulse trend
3. Enter monitor parameters (date/time, intervals) using the                  graphs may be defined by the user with drop down menus
   printer’s clock and automatic measurement functions.                       and a selection dialog box.
                                                                           3. Data Conversion
                                                                              Built-in data conversion capability automatically transposes data
                                          TM-2480      Doctor Pro3            files to compatible spreadsheet and statistical application formats.
 Tabular data output                                                       4. Custom Report
                                                                              Custom report formats may be generated and saved for future use.
 Trend graphs
 Histograms                                                              ■ Special Features
                                                                           1. Patients’ database
 Correlations
                                                                              Doctor Pro 3 manages all patient data in a database and keeps
 HBI Analysis (Pressure load)                                                 track of each patient’s record
 Standard deviation                                                        2. USB connection
                                                                             The Doctor Pro 3 accepts a USB connection to the TM-2430 and
 Customized summary reports
                                                                              UA-767PC via A&D’s USB cable (AX-KO3057-200). No complicated
 Patient record data                                                          communication setting is needed for communicating with A&D
 Data retention                                                               devices. Just connect the monitors and the PC.
                                                               TM-2480
                                                            Printer Terminal




                                                                                                *
                              TM-2430                                                                         UA-767PC




                                                                                                *
                                                           Doctor Pro 3
                                                            Blood Pressure
                           Downloading BP Data
                                                           Analysis Software
                           Uploading Date/Time, Interval

                  *UA-767PC-Date/time only

     Printouts                                                                 Summery Report




Tabular Data
Output




Blood Pressure
Trend




                                                                               Correlations         Histogram




Pulse Trend




                                                                               Trend                BP List




HBI Analysis
(Pressure Load)
TM-2480           Specifications
 Power Supply                       AC Adapter or 6 x LR-06 (AA) Alkaline Batteries
 Power Consumption                  Max. 9.6W
 Display                            LCD
 Printer                            Serial Thermal Dot Matrix
 Printing Speed                     1 Line/Second (approx.)
 Paper Size                         58mm(W) x 50mm(Dia)
 Communication                      EIA RS-232C
 Operating Temperature              +10°C ~ +40°C (+50°F ~104°F) Less than 85% RH (non condensing)
 Storage Temperature                –10°C ~ +55°C (+14°F ~131°F) Less than 95% RH (non condensing)
 Dimensions                         220 (W) x 85 (H) x 130 (D) mm / 8.7 (W) x 3.3 (H) x 5.1 (D) inches
 Weight                             530g (1.2 lbs.)

TM-2480 Contains:
  1-   TM-2480 printer
  1-   Thermal paper
  1-   Communication cable (AX-KO1502)
  1-   AC adapter (AX-TB207, 230V C plug)
  1-   Instruction manual

TM-2480 Options:
  Printer paper (AX-PP147S, 5 rolls/box)
  Communication cable (AX-KO1502)




Doctor Pro 3            Specifications
 Hardware Requirements
  CPU                               Pentium III 1GHz equivalent or higher
  RAM                               256MB or more
  Hard Disk                         1GB required
  Drive                             CD-ROM drive
  Interface                         USB 2.0/1.1
  OS                                Windows™ 2000 Professional, Windows™ XP (Home & Professional)
                                    or Windows™ VISTA (all)

                                                        Windows™ is a registered trademark of Microsoft Corporation.
Doctor Pro 3 (TM9501) Contains:
  1- Software on CD
  1- Communication cable (AX-KO3057-200)
  1- Instruction manual

Doctor Pro 3 Options:
  Communication cable (AX-KO3057-200)




                                                          3-23-14 Higashi-Ikebukuro,Toshima-ku,Tokyo 170-0013 Japan
                                                          Telephone:[81](3)5391-6132 Fax:[81](3)5391-6148
                                                          1-243, Asahi,Kitamoto-shi,Saitama, 364-8585 Japan
                                                          Telephone:[81](0485)93-1111 Fax:[81](0485)93-1119
                                                          (EN46001 Certified Factory)
                                                          http://www.aandd.jp

                                                          1756 Automation Parkway, San Jose, CA 95131 U.S.A.
                      Medical/LifeSource
                  A&D Medical LifeSource                  Telephone:[1](408)263-5333 Fax:[1](408)263-0119

                                                          Unit 24/26 Blacklands Way Abingdon Business Park,
                                                          Abingdon, Oxon OX14 1DY UNITED KINGDOM
                                                          Telephone:[44](1235) 550420 Fax:[44](1235) 550485
                                                          (Authorized Representative Established in the European Community)

                                                          32 Dew Street, Thebarton, South Australia 5031 AUSTRALIA
                                                          Telephone:[61](8)8301-8100 Fax:[61](8)8352-7409

                                                          Vereyskaya str.112 Kuntsevo Block, 121357,
                  A&D RUS CO., LTD.                       Moscow, RUSSIA
                                                          Telephone: [7] (495) 937-33-44 Fax: [7] (495) 937-55-66

                                                          Manhattan Bldg. 8F, 36-2 Yoido-dong, Youngdeungpo-gu, Seoul, KOREA
                                                          Telephone:[82](2) 780-4101 Fax:[82](2) 782-4280



                    D Inst uments       Pr    e mited
                  A&D Instruments India Private Limited
                                                          509 Udyog Vihar Phase V Gurgaon-122 016, Haryana, INDIA
                                                          Telephone: [91](124) 471-5555 Fax: [91](124) 471-5599


                                                                                                                               ADC-TM2480-04-PR4-08a02

				