Embed
Email

Help

Document Sample
Help
Shared by: HC111203194235
Categories
Tags
Stats
views:
2
posted:
12/3/2011
language:
English
pages:
7
Help





About SCview.xls, version 4.2, 22-November-2006



SCview.xls is an Excel Spreadsheet for viewing and printing results from the

SC11 version 2.3 or later and the SC15 (any version).

Because of a file format change, you need version 1.7 or later for SC11 version 4.2.

This version of the spreadsheet is required to view the Chart and Spectrum Datalog files.

It is provided by Spicer Consulting free of charge, but without any support commitment.

Feel free to copy and modify it. It was developed under Excel 97 and requires Visual Basic Macros enabled.



Using this Spreadsheet



To view exported data, click the Chart tab and press the Open button which is to the right

of the chart. Select a text file that has been exported by the SC11 or SC15 and click

Open. The file will be displayed on the chart. The Preview button gives you a Print Preview and the

Print button prints the chart immediately, with no intervening dialog boxes.

The "Chart Axes" button gives access to a simple window to change the axis and title options. There are 3 buttons:

"Apply" makes any changes to the chart and keeps the window open, "OK" makes any changes and closes the window.

"Cancel" and the "close window" icon in the corner will close the window without making any changes since the last time "Apply" w



The tables below control the standard settings of the Y axis for the various different units.

You can edit the table to change the settings.

If you wish to add a user defined unit to the SC11 list below, use the "Add User Defined Y unit" button.

This will ensure that the unit is placed in the list in a position where the search for units is not disrupted.

The new export file format contains range information for the data. This is used to set up the initial chart.

If this range information is not present then the chart range is set using the tables below



How it works



Open calls the macro LoadFile which opens the text file and

puts it under the Data tab. It then fills in the X axis values and works out all the information for the

chart before updating it. Open relies on the chart being partly set up beforehand. Therefore you can

change some aspects of the chart manually and Open will keep them the same. However, it might

stop working if you remove something it expects to be there.

The "Add User Defined Y unit" button brings up a form to fill in the details of the new unit. It also checks

that the details are valid and places the new unit in the list in a position where the "open" routine's search

for an appropriate unit will not be disrupted. Note: the unit may not be placed in an obvious location in the list.



SC15 Y Unit Table

SC11 Y Unit Table This table sets a standard Y axis title a

This table sets a standard Y axis title and range for each Y unit * is a wildcard. The last row matches a

Yunit Title Log Ymin Ymax Yunit

mG Magnetic Field TRUE 0.001 10 *N

nT Magnetic Field TRUE 1 1000 *lbf

uT Magnetic Field TRUE 0.001 1 *Pa

A/m Magnetic Field TRUE 0.001 1 *psi

mA/m Magnetic Field TRUE 0.1 100 dB

V Voltage TRUE 0.001 10 um/s2

mV Voltage TRUE 1 1000 mm/s2

ug's Acceleration TRUE 0.0001 10 *m/s2

mg's Acceleration TRUE 0.0001 10 *g's

mm/s2 Acceleration TRUE 0.01 100 *Gal

mm/s Velocity TRUE 0.0001 0.1 mil/s2

um/s Velocity TRUE 0.01 100 inch/s2

um Displacement TRUE 0.001 1 um/s

nm Displacement TRUE 0.001 1 mm/s

Pa Sound Level TRUE 0.001 1 *m/s









Page 1

Help





mPa Sound Level TRUE 1 30 mil/s

dB Sound Level FALSE 50 90 inch/s

Default User Defined Units TRUE Auto Auto um

Add User Defined Y unit

mm

*m

mil

inch

degrees

*V

*T

*Gauss

(*)2

(*)2/Hz

*









Page 2

Help









sual Basic Macros enabled.









title options. There are 3 buttons:

s any changes and closes the window.

making any changes since the last time "Apply" was clicked.







Defined Y unit" button.

r units is not disrupted.

o set up the initial chart.









new unit. It also checks

e "open" routine's search

n obvious location in the list.



SC15 Y Unit Table

This table sets a standard Y axis title and range for each Y unit

* is a wildcard. The last row matches anything the other rows missed.

Title Log Ymin Ymax

Force TRUE 0.001 100

Force TRUE 0.001 100

Pressure TRUE 0.001 100

Pressure TRUE 0.001 100

FALSE -60 40

Acceleration TRUE 0.001 100

Acceleration TRUE 0.001 100

Acceleration TRUE 0.001 100

Acceleration TRUE 0.001 100

Acceleration TRUE 0.001 100

Acceleration TRUE 0.001 100

Acceleration TRUE 0.001 100

Velocity TRUE 0.001 100

Velocity TRUE 0.001 100

Velocity TRUE 0.001 100









Page 3

Help





Velocity TRUE 0.001 100

Velocity TRUE 0.001 100

Displacement TRUE 0.001 100

Displacement TRUE 0.001 100

Displacement TRUE 0.001 100

Displacement TRUE 0.001 100

Displacement TRUE 0.001 100

Phase FALSE -200 200

Voltage TRUE 0.001 100

Magnetic Field Strength TRUE 0.001 100

Magnetic Field Strength TRUE 0.001 100

Power Spectrum TRUE 0.001 100

Power Spectral Density TRUE 0.001 100

FALSE Auto Auto









Page 4

Data





Exported by SC11 Spectrum Analyser 3.0 - Sensor 02016

14:30 21-May-02

window Hanning averages 8

xunit Hz fx 1.258925 points 21 x0

Frequency (Hz) A Spec

dB (RMS) dB (RMS)

1.58E+01 6.50E+01 7.00E+01

2.00E+01 4.92E+01 5.00E+01

2.51E+01 5.15E+01 5.00E+01

3.16E+01 5.34E+01 5.00E+01

3.98E+01 5.06E+01 5.00E+01

5.01E+01 5.28E+01 4.00E+01

6.31E+01 4.89E+01 4.00E+01

7.94E+01 5.16E+01 4.00E+01

1.00E+02 4.76E+01 4.00E+01

1.26E+02 4.51E+01 7.00E+01

1.58E+02 4.54E+01 7.00E+01

2.00E+02 4.88E+01 7.00E+01

2.51E+02 4.48E+01 7.00E+01

3.16E+02 4.08E+01 5.00E+01

3.98E+02 4.23E+01 5.00E+01

5.01E+02 4.67E+01 5.00E+01

6.31E+02 4.48E+01 5.00E+01

7.94E+02 4.20E+01 4.00E+01

1.00E+03 3.97E+01 4.00E+01

1.26E+03 4.03E+01 4.00E+01

1.58E+03 3.64E+01 4.00E+01









Page 5

Data









1.58E+01









Page 6

90





85





80

Sound Level dB (RMS)









75





70





65





60





55





50









Frequency (Hz)

A Spec



Averages: 8 Window: Hanning A Peak: 65.041 dB (RMS) At: 15.85 Hz

Filename: C:\Data\SoundLevel3.txt Program: Exported by SC11 Spectrum Analyser 3.0 - Sensor 02016

Figure: 1 Time: 14:30 21-May-02


Related docs
Other docs by HC111203194235
???????
Views: 7  |  Downloads: 0
Adapter
Views: 13  |  Downloads: 0
Subtraction questions
Views: 0  |  Downloads: 0
MASSES THIS WEEK AT EPIPHANY
Views: 2  |  Downloads: 0
Mary L
Views: 1  |  Downloads: 0
DUNDEE CITY SPORTS COUNCIL
Views: 7  |  Downloads: 0
MONTESSORI EDUCARE ACADEMY
Views: 5  |  Downloads: 0
Ennis Track Club Ope.. - Marian AC Homepage
Views: 0  |  Downloads: 0
Artículos_3713
Views: 0  |  Downloads: 0
Vom Gebet (De oratione)
Views: 1  |  Downloads: 0
By registering with docstoc.com you agree to our
privacy policy

You are almost ready to download!

You are almost ready to download!