Help

Shared by: 78Wa5371
Categories
Tags
-
Stats
views:
8
posted:
12/3/2011
language:
English
pages:
7
Document Sample
scope of work template
							                                                     Help


About SCview.xls, version 4.2, 22-November-2006

SCview.xls is an Excel Spreadsheet for viewing and printing results from the
SC11 version 2.3 or later and the SC15 (any version).
Because of a file format change, you need version 1.7 or later for SC11 version 4.2.
This version of the spreadsheet is required to view the Chart and Spectrum Datalog files.
It is provided by Spicer Consulting free of charge, but without any support commitment.
Feel free to copy and modify it. It was developed under Excel 97 and requires Visual Basic Macros enabled.

Using this Spreadsheet

To view exported data, click the Chart tab and press the Open button which is to the right
of the chart. Select a text file that has been exported by the SC11 or SC15 and click
Open. The file will be displayed on the chart. The Preview button gives you a Print Preview and the
Print button prints the chart immediately, with no intervening dialog boxes.
The "Chart Axes" button gives access to a simple window to change the axis and title options. There are 3 buttons:
"Apply" makes any changes to the chart and keeps the window open, "OK" makes any changes and closes the window.
"Cancel" and the "close window" icon in the corner will close the window without making any changes since the last time "Apply" w

The tables below control the standard settings of the Y axis for the various different units.
You can edit the table to change the settings.
If you wish to add a user defined unit to the SC11 list below, use the "Add User Defined Y unit" button.
This will ensure that the unit is placed in the list in a position where the search for units is not disrupted.
The new export file format contains range information for the data. This is used to set up the initial chart.
If this range information is not present then the chart range is set using the tables below

How it works

Open calls the macro LoadFile which opens the text file and
puts it under the Data tab. It then fills in the X axis values and works out all the information for the
chart before updating it. Open relies on the chart being partly set up beforehand. Therefore you can
change some aspects of the chart manually and Open will keep them the same. However, it might
stop working if you remove something it expects to be there.
The "Add User Defined Y unit" button brings up a form to fill in the details of the new unit. It also checks
that the details are valid and places the new unit in the list in a position where the "open" routine's search
for an appropriate unit will not be disrupted. Note: the unit may not be placed in an obvious location in the list.

                                                                                                 SC15 Y Unit Table
SC11 Y Unit Table                                                                                This table sets a standard Y axis title a
This table sets a standard Y axis title and range for each Y unit                                * is a wildcard. The last row matches a
   Yunit                Title                 Log         Ymin            Ymax                      Yunit
     mG             Magnetic Field           TRUE         0.001            10                          *N
     nT             Magnetic Field           TRUE           1             1000                        *lbf
     uT             Magnetic Field           TRUE         0.001             1                         *Pa
    A/m             Magnetic Field           TRUE         0.001             1                        *psi
   mA/m             Magnetic Field           TRUE          0.1             100                        dB
      V                Voltage               TRUE         0.001            10                       um/s2
     mV                Voltage               TRUE           1             1000                      mm/s2
    ug's             Acceleration            TRUE        0.0001            10                       *m/s2
    mg's             Acceleration            TRUE        0.0001            10                        *g's
  mm/s2              Acceleration            TRUE          0.01            100                       *Gal
   mm/s                Velocity              TRUE        0.0001            0.1                      mil/s2
    um/s               Velocity              TRUE          0.01            100                     inch/s2
     um             Displacement             TRUE         0.001             1                        um/s
     nm             Displacement             TRUE         0.001             1                       mm/s
     Pa              Sound Level             TRUE         0.001             1                        *m/s




                                                   Page 1
                                           Help


   mPa              Sound Level    TRUE             1           30     mil/s
    dB              Sound Level    FALSE            50          90    inch/s
Default       User Defined Units   TRUE      Auto        Auto            um
Add User Defined Y unit
                                                                        mm
                                                                         *m
                                                                         mil
                                                                        inch
                                                                     degrees
                                                                          *V
                                                                          *T
                                                                     *Gauss
                                                                         (*)2
                                                                      (*)2/Hz
                                                                           *




                                       Page 2
                                                                           Help




sual Basic Macros enabled.




 title options. There are 3 buttons:
s any changes and closes the window.
making any changes since the last time "Apply" was clicked.



Defined Y unit" button.
 r units is not disrupted.
o set up the initial chart.




new unit. It also checks
e "open" routine's search
 n obvious location in the list.

            SC15 Y Unit Table
            This table sets a standard Y axis title and range for each Y unit
            * is a wildcard. The last row matches anything the other rows missed.
                                   Title               Log        Ymin       Ymax
                                   Force              TRUE        0.001       100
                                   Force              TRUE        0.001       100
                                 Pressure             TRUE        0.001       100
                                 Pressure             TRUE        0.001       100
                                                     FALSE         -60        40
                               Acceleration           TRUE        0.001       100
                               Acceleration           TRUE        0.001       100
                               Acceleration           TRUE        0.001       100
                               Acceleration           TRUE        0.001       100
                               Acceleration           TRUE        0.001       100
                               Acceleration           TRUE        0.001       100
                               Acceleration           TRUE        0.001       100
                                  Velocity            TRUE        0.001       100
                                  Velocity            TRUE        0.001       100
                                  Velocity            TRUE        0.001       100




                                                                          Page 3
                                           Help


       Velocity           TRUE    0.001   100
       Velocity           TRUE    0.001   100
    Displacement          TRUE    0.001   100
    Displacement          TRUE    0.001   100
    Displacement          TRUE    0.001   100
    Displacement          TRUE    0.001   100
    Displacement          TRUE    0.001   100
        Phase             FALSE   -200    200
       Voltage            TRUE    0.001   100
Magnetic Field Strength   TRUE    0.001   100
Magnetic Field Strength   TRUE    0.001   100
  Power Spectrum          TRUE    0.001   100
Power Spectral Density    TRUE    0.001   100
                          FALSE   Auto    Auto




                                          Page 4
                                               Data


            Exported by SC11 Spectrum Analyser 3.0 - Sensor 02016
                   14:30 21-May-02
                window Hanning        averages 8
                    xunit Hz                 fx 1.258925          points 21   x0
Frequency (Hz)    A           Spec
             dB (RMS)      dB (RMS)
   1.58E+01    6.50E+01      7.00E+01
   2.00E+01    4.92E+01      5.00E+01
   2.51E+01    5.15E+01      5.00E+01
   3.16E+01    5.34E+01      5.00E+01
   3.98E+01    5.06E+01      5.00E+01
   5.01E+01    5.28E+01      4.00E+01
   6.31E+01    4.89E+01      4.00E+01
   7.94E+01    5.16E+01      4.00E+01
   1.00E+02    4.76E+01      4.00E+01
   1.26E+02    4.51E+01      7.00E+01
   1.58E+02    4.54E+01      7.00E+01
   2.00E+02    4.88E+01      7.00E+01
   2.51E+02    4.48E+01      7.00E+01
   3.16E+02    4.08E+01      5.00E+01
   3.98E+02    4.23E+01      5.00E+01
   5.01E+02    4.67E+01      5.00E+01
   6.31E+02    4.48E+01      5.00E+01
   7.94E+02    4.20E+01      4.00E+01
   1.00E+03    3.97E+01      4.00E+01
   1.26E+03    4.03E+01      4.00E+01
   1.58E+03    3.64E+01      4.00E+01




                                              Page 5
           Data




1.58E+01




           Page 6
                        90


                        85


                        80
 Sound Level dB (RMS)




                        75


                        70


                        65


                        60


                        55


                        50




                                        Frequency (Hz)
                                        A     Spec

Averages: 8           Window: Hanning                 A Peak: 65.041     dB (RMS)         At: 15.85       Hz
Filename: C:\Data\SoundLevel3.txt                    Program: Exported by SC11 Spectrum Analyser 3.0 - Sensor 02016
   Figure: 1                                            Time: 14:30      21-May-02

						
Related docs
Other docs by 78Wa5371
Year 2 Planning Autumn Term 2002
Views: 27  |  Downloads: 0
ARANSAS COUNTY INDEPENDENT SCHOOL DISTRICT
Views: 9  |  Downloads: 0
Kokerprofielen Staal
Views: 233  |  Downloads: 0
?????????
Views: 15  |  Downloads: 0
Leht1 - Download as Excel
Views: 356  |  Downloads: 0
Sheet1
Views: 216  |  Downloads: 0
Promote
Views: 9  |  Downloads: 0
Diapositiva 1
Views: 51  |  Downloads: 0