1.    Detection Strips, Urine
1.1   Detection Strips, Urine for Glycosuria

 X    1.1.1 Clinistix                                                      bottle of 50 .................. 3.27
      Strip impregnated one end with: glucose oxidase and a peroxidase, and o-tolidine, buffered.
      (Supplied with an instruction sheet, analysis record and colour chart)


      1.1.2 Diabur Test 5000                                                 vial of 50 .................. 2.92
      Twin zone strip impregnated one end with: glucose oxidase/peroxidase and tetramethylbenzidine
      indicator.
      (Supplied with an instruction sheet, analysis record and colour chart)


      1.1.3 Diastix                                                        bottle of 50 .................. 2.78
      Strip impregnated one end with: glucose oxidase and a peroxidase, and potassium iodide, buffered.
      (Supplied with an instruction sheet, analysis record and colour chart)


      1.1.4 Medi-Test Glucose                                              bottle of 50 .................. 2.33
      Strip impregnated one end with: glucose oxidase and a peroxidase, and o-tolidine.
      (Supplied with an instruction sheet, analysis record and colour chart)

      1.1.5    Mission Glucose                          1G                  container of 50 .................. 2.29




1.2   Detection Strips, Urine for Ketonuria (Acetonuria)

      1.2.1 Ketostix                                                     bottle of 50 .................. 2.95
      Strip impregnated one end with: sodium nitroprusside, glycine, and phosphate buffer.
      (Supplied with an instruction sheet and colour chart)


     1.2.2 Ketur Test                                                     vial of 50 .................. 2.81
      Strip impregnated one end with: sodium nitroprusside, glycine and alkaline buffer.
      (Supplied with an instruction sheet and colour chart)

      1.2.3    Mission Ketone                           1K                  container of 50 .................. 2.50




 To be deleted 1 February 2011
X To be deleted 1 December 2011




November 2011                                           1
Part II                      Approved List Of Chemical Reagents


1.3   Detection strips, Urine for Proteinuria

      1.3.1 Albustix                                                     bottle of 50 .................. 4.10
      Strip impregnated one end with: tetrabromophenol blue, and citrate buffer.
      (Supplied with an instruction sheet, and colour chart)

      1.3.2 Medi-Test Protein 2                                         bottle of 50 .................. 3.27
      Strip impregnated one end with: tetrabromophenol blue and citrate buffer.
      (Supplied with instruction sheet and colour chart)




2.    Detection Strips, Blood For Glucose
      Notes on the use of Blood Glucose Testing Strips (BGTS) are given in the appendix to Part II.
      Lancets are listed in Part III under 'Hypodermic Equipment'. Meters for use with BGTS or Discs are
      not available separately on Prescription Form HS21.


2.1   Colorimetric Strips - Visually Readable

      2.1.1   Betachek Visual                                              container of 50 .................. 6.80


      2.1.2 Glucoflex-R                                              container of 50 .................. 7.40
      Strip with dual pads at one end impregnated with glucose oxidase and chromogens. The low range
      pad gives readings between 1.0 and 7.0 mmol/l, light to mid blue. The high range pad gives
      readings between 7.0 and 44.0mmol/l, buff-green to dark green. This strip can be used with all
      Reflolux Blood Glucose Meters.

      (Supplied with an instruction sheet, meter barcode strip and colour chart.)




November 2011                                          2
Part II                     Approved List Of Chemical Reagents



2.2   Biosensor Strips - to be read only with the appropriate meter
      NB These meters are not available on prescription.

      Biosensor strips have a target area for the blood sample at one end impregnated with glucose
      oxidase. The test strip is inserted into the meter and when the blood sample is applied to the target
      area a current is produced proportionate to the concentration of blood glucose in the sample.
      NB Exactech, MediSense G2 and MediSense Optium strips are not interchangeable

      2.2.1 Advantage Plus                                              container of 50 ............... 15.44
      Strip with an arc-shaped indentation along one side for easy sample application. The test area is
      located in the centre of the strip, covered by a translucent laminate. Blood is drawn into the test area
      from the curved edge of the strip by capillary action and glucose is converted by glucose
      dehydrogenase in a two-step bi-amperometric process. The small current produced is read by the
      meter and converted to a glucose concentration. The strip gives readings in the range 0.6-
      33.3mmol/l. The strips cannot be visually read and the use of an Advantage meter is essential.

      Ascensia Microfill see Contour

      2.2.2   Aviva                                                    container of 50 ............... 15.15

      2.2.3   CareSens N                                               container of 50 ............... 12.75

      2.2.4   Clever Chek                                              container of 50 ............... 16.30

      2.2.5   Contour                                                  container of 50 ............... 14.85

      2.2.6   CozyLab S7                                               container of 50 ................. 9.85

      2.2.7   Element                                                  container of 50 ............... 11.50      NEW

      2.2.8 FreeStyle                                                container of 50 ................ 15.16
      Freestyle test strips enable simple blood glucose testing using the Freestyle colorimetric meter.
      Freestyle strips contain PQQ Glucose Dehydrogenase and detect glucose levels between
      1.1mmol/L and 27.8mmol/L.

      2.2.9   FreeStyle Lite                                            container of 50 ................ 15.16

      2.2.10 FreeStyle Optium (formerly Optium Plus)                    container of 50 ................ 15.06

      2.2.11 GlucoLab                                                   container of 50 .................. 9.89   NEW

      2.2.12 GlucoMen GM                                                container of 50 ................ 14.93

      2.2.13 GlucoMen LX Sensors                                        container of 50 ................ 14.91

      2.2.14 GlucoMen Sensors                                          container of 50 ............... 13.94
      Gives a reading in the range 1.1-33.3mmol/L.
      (Supplied with an instruction data sheet)

      2.2.15 GlucoMen Visio                                            container of 50 ............... 14.80

      2.2.16 GlucoRx Strips                                            container of 50 ................. 9.95

      2.2.17 GlucoRx Nexus Strips                                      container of 50 ................. 9.95

      2.2.18 IME-DC                                                    container of 50 ............... 14.10




November 2011                                        3
Part II                    Approved List Of Chemical Reagents



     2.2.19 Medisense SoftSense                                       container of 50 ............... 15.05
     MediSense SoftSense blood glucose biosensor test strips for use with the MediSense SoftSense
     blood glucose meter. Fresh capillary blood can be drawn for testing from alternative sites (such as
     the forearm, upper arm, base of thumb) and traditional finger sites. Gives a reading of 1.7 - 2.5
     mmol/l.
     (Supplied with instruction sheet and meter calibrator.)

     2.2.20 Microdot                                                   container of 50 ............... 12.96

     2.2.21 Microdot +                                                 container of 50 ............... 13.50

     2.2.22 Myglucohealth                                              container of 50 ............... 15.50

     2.2.23 Mylife Pura                                                container of 50 ............... 13.99     

     2.2.24 Omnitest 3                                                 container of 50 ............... 12.00

     2.2.25 On-Call Advanced                                           container of 50 ............... 13.65

     2.2.26 One Touch Ultra                                            container of 50 ............... 15.00

     Biosensor test strip. 1 microlitre blood is applied to the top edge of the strip. The blood is drawn into
     a reaction cell impregnated with glucose oxidase. The system measures an electric current
     generated from the reaction, which is proportional to the level of glucose in the sample.
     Measurement range is 1.1-33.3mmol/L. Alternative site testing is possible.
     (Supplied with an instruction sheet.)

     2.2.27 One Touch Verio                                            container of 50 ................ 14.99

     2.2.28 One Touch Vita                                             container of 50 ................ 14.81

              Optium Plus see FreeStyle Optium

    2.2.29 PocketScan                                               container of 50 ............... 14.41
     Biosensor test strip with a target area for the blood sample at one end. The test strip is inserted
     into the meter and when a small blood sample is applied to the target area it is then automatically
     drawn by capillary action into the reaction cell impregnated with glucose oxidase. The system
     measures an electric current generated from the reaction, which is proportional to the level of
     glucose in the sample. Measurement range is 1.1-33.3mmol/L.
     (Supplied with an instruction sheet.)

     2.2.30 Sensocard                                                  container of 50 ............... 16.30

     2.2.31 SuperCheck 2                                               container of 50 ................. 8.49

     2.2.32 TRUEone                                                    container of 50 ......... ……14.52

     2.2.33 TRUEresult                                                 container of 50 ......... ……14.53

     2.2.34 TrueTrack System                                           container of 50 ............... 14.52

     2.2.35 WaveSense Jazz                                             container of 50 ............... 14.73




 to be deleted 1 January 2012




November 2011                                       4
Part II                      Approved List Of Chemical Reagents



2.3   Biosensor Disc - to be read only with the appropriate meter
      Biosensor test sensor disc contains 10 individually sealed test strips. Blood is drawn by capillary
      action into a strip exposed from inside the meter. The level of glucose is measured using a
      mediated electrochemical technique based on the glucose oxidase.

      2.3.1 Ascensia Autodisc Test Sensor Disks            5 discs of 10 strips each ............... 14.73
      For use with Ascensia Breeze (with automatic calibration) and
      Ascensia Espirit 2 blood glucose meters (with manual calibration).
      Gives reading in the range 0.6 – 33mmol/L
      (supplied with instruction sheet).

      2.3.2   Breeze 2                                        5 discs of 10 strips each ............... 14.45

      2.3.3   Every x 3                                      15 drums of 6 strips each ............... 25.35




2.4   Colorimetric Strips- to be read only with the appropriate meter


      2.4.1 Active                                                     container of 50 ............... 15.43
      Strip with application zone consisting of detection film, covered by an orange protective mesh and
      featuring a reservoir to collect excess blood. Glucose is converted by glucose-dye-
      oxidoreductase, and an indicator reaction produces the colour change. The strip gives readings in
      the range of 0.6 - 33.3mmol/L. The use of a Glucotrend, Glucotrend 2, Glucotrend Premium or
      Accu-Chek Activ meter is essential.
      (Supplied with an instruction sheet, colour chart and coding chip).

      2.4.2   Betachek G5                                               container of 50 ............... 14.19


      2.4.3 Compact                                         3 drums of 17 strips each ................ 15.56
      Drum containing 17 individually sealed test strips. Blood is drawn by capillary action into a strip
      exposed from inside the meter. Glucose is converted by glucose-dye-oxidoreductase, and an
      indicator produces the colour change. The strip gives readings in the range of 0.6 - 33.3 mmol/L.
      The strips cannot be visually read and the use of an Accu-Chek Compact meter is essential.
      (Supplied with an instruction sheet.)




November 2011                                        5
Part II                         Approved List Of Chemical Reagents



      2.4.4 One Touch                                                     container of 50 ................ 14.84
       Strip with a small circular test area forming a well over a single pad impregnated with glucose
       oxidase, peroxidase and chromogens. The strip gives readings in the range 0.0-33.3mmol/L (cream
       to blue). The strips cannot be visually read, and the use of a “One Touch” blood glucose meter is
       essential.
       (Supplied with an instruction sheet and analysis record).


2.5      Colorimetric Cassette- to be read only with the appropriate meter

         2.5.1   Mobile                                                     container of 100 ................ 30.47


2.6      Colorimetric Test Tip

         2.6.1   FineTouch testing tips                                                     50 ................ 14.43




3.       Detection Strips, Blood For Ketones (Beta-Hydroxybuterate)
         -to be read only with appropriate meter which is not available on prescription.
3.1      FreeStyle Optium β-Ketone Test Strips            70784-35                     10 ................ 20.27

3.2      GlucoMen LX Ketone Test Strips                       42216                         10 ................ 19.93


         Optium β-Ketone Test Strips see FreeStyle Optium β-Ketone Test Strips




 To be deleted 1 January 2012




November 2011                                             6
Part II                      Approved List Of Chemical Reagents



4.     Detection Strips For Use In Testing Blood For Determination Of International
       Normalised Ratio (INR)
       Test strips for the quantitative determination of Prothrombin Time in capillary or venous whole blood
       in the range of 0.8 to 8.0 International Normalised Ratio (INR) using the CoaguChek/CoaguChek S
       monitor. Field of application. Test for monitoring oral anticoagulation therapy. (Long term therapy
       with coumarin derivatives.)

4.1    Alere INRatio (formerly                0100071                               12 ................ 30.53
       HemoSense INRatio)                     0100139                               48 .............. 119.35


4.2    CoaguChek PT
       (Roche Diagnostics)                    1937634                               12 ................ 32.55
                                              1937642                               48 .............. 127.26

4.3    CoaguChek XS PT Test
       (Roche Diagnostics)                    04625358                              24 ................ 65.09
                                              04625315                              48 .............. 127.25

      HemoSense INRatio see Alere INRatio

4.4    ProTime 3 curvettes
                                              49006000                               6 ................ 15.54
                                              49005000                              25 ................ 63.25


5.     Detection Pad, Sweat For Neuropathy
5.1    Neuropad                                                                      2 .................. 7.07

       CoaguChek testing strips are designed to be used with the CoaguChek meter, which is not available
       on prescription.

       (Supplied with an instruction sheet and meter code chip.)




November 2011                                       7
Part II                    Approved List Of Chemical Reagents


Part II - Appendix

     Notes on Blood Glucose Testing
1.   Blood glucose testing strips (BGTS) are primarily intended for insulin-dependent diabetics who will
     normally have received consultant advice on their condition. One pack (50 strips) would normally be
     sufficient for 2 months. All strips should be kept in their original container and should not be cut or
     slit. Because of the differences in colour change in colorimetric types, strips are not
     interchangeable.
     Due regard should be given to the manufacturer's instructions and to the recommendation
     on storage and period of use after first opening.

2.   Misleading results, which could be hazardous if acted upon, might arise if users are inadequately
     trained. It is therefore essential that patients should receive appropriate training before attempting to
     use BGTS for monitoring their blood glucose. This instruction should be given by health care
     professionals who are trained in the use of the product. It should be noted that there are small
     variations in technique between different makes. Some technical factors are given in paragraph 5
     below.

3.   General practitioners should be aware that defects in colour vision may occur in diabetes and certain
     BGT strips should not be prescribed for such patients for visual use. (see outline of colour changes
     described in each entry on the foregoing pages).

4.   Reagent Strips are subject to the following limitations:

     Fluoride Specimen:       The strips are not to be used with blood specimens preserved with fluoride.

     Serum and Plasma:        The strips are not designed for use with serum or plasma.

     Haematocrit:             Extremes in haematocrit levels can affect test results:


     Due regard should be given to the manufacturer’s product specifications.

5.   Disposal of Lancets. Patients should be reminded of the need to exercise caution when disposing of
     used lancets. These should be placed in a tin or other strong container before disposal. (The
     needle clipping device listed in Part III is not generally suitable for use with lancets).

     As with single-use syringes, the arrangements outlined above are not suitable for patients where
     there is a risk of infection being transmitted. General Practitioners are similarly advised that blood
     lancets should only be prescribed for patients who are carriers of infectious diseases where suitable
     arrangements have been made for the disposal of the used articles as contaminated waste. Medical
     Officers for environmental health can advise on these arrangements.