GMSI LOWCOST
CARWASH STRUCTURES
1- ONE STOP SHOPPING FOR YOUR CARWASH BUILDING
2- IN HOUSE DESIGN BY OUR OWN UK ENGINEERS
3- LOCAL AUTHORITY DESIGN QUERIES DEALT WITH BY GMSI
4- DESIGN FLEXIBILTY - WE FIT THE BUILDING TO SUIT YOUR REQUIREMENTS
5- MANUFACTURED IN OUR OWN FACTORY
6- INSTALLED BY OUR OWN ERECTORS.
7- MANAGEMENT AND SUBCONTRACTOR SUPERVISION BY OUR OWN SITE
MANAGEMENT.
8- ALL SITES SURVEYED BY OUR OWN SURVEYORS
9- IN HOUSE CONTROL FOR BETTER QUALITY, BETTER DELIVERY, BETTER
FLEXIBILITY
10- QUALITY AND SAFETY CERTIFIED TO THE HIGHEST CRITERIA.
1. Building.
STRUCTURE Standard glazed barrel vault carwash enclosure supported on 6no. main columns
& 4no. door posts.
DIMENSIONS 10450mm x 5100mm main carwash external plan dimensions.
COLUMN SIZE 100*100 SHS main columns.
CLEAR HEIGHT 3200mm from datum.
FRAME STRUCTURE
Constructed from structural hollow section columns and rafters with paralell channel
eaves tie acting as rainwater gutter.
All material to be supplied in accordance with section properties of BS4 part 1 and BS4848 part 4.
The fabrication tolerances of all fabricated structural steelwork will be in accordance with the
National Structural Steelwork Specification, 3rd Edition. All hot rolled steel work to be hot dipped
galvanised after fabrication to EN ISO 1461 : 1999 80 microns zinc film thickness.Proprietary items
supplied in manufacturer standard finish.
FASCIAS 700mm deep non structural fascia, complete with high level radius corners and radius vertical
corner column cladding.
Manufactured from 1.5mm thick galvanised steel sheet, polyester powder coat finish to Sainsbury’s
Blue RAL 5002.
BARREL VAULT Purpose made low rise translucent barrel vault.
Constructed from 60*60 structural hollow section rafters spanning to a radius of 5000mm, glazed with a translucent
16mm multiwall polycarbonate sheet externally clamped with an 4mm aluminium pressure plate. Ends to be infilled
with same polycarbonate sheet fixed to end rafter with curved cleader rail.
GLAZING Side elevations 10000mm x 3100mm.
Constructed from extruded aluminium flush frames - 102 x 45 box section with pocket glazing seals, finish anodised
satin silver grade AA25, glazed with 6.4mm laminated safety glass. 7no. panes per elevation, size to be 14285mm x
3100mm.
Options:
500mm extension modules, length and width
Optional solid rear wall
2. Doors.
VEHICLE ENTRY AND EXIT DOORS SPECIFICATION
ALR 40 Aluminium Sectional Door(s)
Sectional Overhead Door made from aluminium extruded sections c/w 52mm / 91mm wide intermediate vertical rails and
infill as detailed below.
(Refer to Sectional Door Technical Manual for exact No. of sections).
Infill
Bottom,intermediate and top sections glazed with 3mm single clear acrylic sheet.
Electrically operated
Electrically operated by a WA 100 - Single Phase 240v operator with: Emergency hand chain in case of power failure,
automatic reset.
IP65 protection.
Slack cable devices.
Controls
Lift rate - 150mm/sec (see section 10 -Alternatives)
B 45 N Prewired control unit built into motor c/w ready to plug in safe extra low 24v "OPEN-STOP-CLOSE" membrane
keypad with miniature lock. Open and close by "press and hold" (deadman) only. CEE 16 amp 3 pin 240v IP64 protection
plug in connections for operator and control wiring.
Opto-electric self monitoring closing edge safety devise to automatically stop a closing door on obstruction and return
150mm to clear.
Photocell safety beam.
Red & Green traffic lights.
Volt free status relays.
Tracks - galvanised steel tracks
N - Normal lift.
Finish
Aluminium extrusions anodised in natural finish.
Locking
Standard inside lock c/w electrical interlock.
Security anti-lift device.
EPDM Seals
Hollow profile seal with double lip as floor seal, central seal between the individual door sections, plastic side contact strips
and lintel seal.
Compliance with:
BS EN 12453: 2001 - Requirement for Safety in use of Power Operated Doors.
BS EN 12604: 2000 - Mechanical Aspects.
* Finger trap protection to panel joints inside and out.
* Side frames shaped as hand guards.
* Covered cable drums: (with Low Headroom tracks & <2500mm high)
* Open and close by dead-man control only.
* Operator with self-holding gears to hold door in the event of cable or spring failure (Anti-drop safeguard).
* Anti-slack cable device.
* Power operated doors CE Marked with manufacturers declaration of conformity.
s
* Prevention of persons being lifted: (Dead-man' control or torque limit on impulse control)
* Closing forces: 400N
2 No. 3.9m long x 3.2m high.
Personnel
Wicket Door (Pass Door)
Outward opening inset wicket personnel door (position dependent on door width) c/w profile cylinder mortise lock, black
plastic lever handle set, door closer and electrical interlock switch.(required to one end only.)
OR
Emergency access door in driver'side elevation (required to one side only.)
s
Single escape door in glazing screen, fitted with 1no. Briton 376 face panic bolt (no external locking facility)
3. Electrics
To establish which of the following options will apply to each site, a detailed electrical survey and monitoring period is
recommended, the cost of which is not included in this proposal.
1-In some but not all instances it will be necessary to deliver power to the building . If so it will have to come from the
plant room :
To get power to the building from an integrated plant room
OR
To get power to the building from a remote plant room
2- Having connected the building , power must be taken to both the entry and exit doors
To get power from the building to the carwash doors :
Install 2 supplies terminated into weatherproof isolators for roller shutters at either end of the building.
3 - In order for the wash to control the doors a Car Wash Machine/ Doors Interface is required.
Provide signal cables from card acceptor and connections to enable door control by carwash machine.
4. Other electrical equipme nt
1. Lighting.
3 twin batten fluorescent light units.
Emergency light for each personnel door
Heaters
2 No. Bush Nelson SWD-A-3000-2 including
wire guards controlled via a froststat and time
clock.
Two of these units will maintain an interior
temperature of +1C at an outside temperature of
-5C. To maintain 1C inside down to-10C three
units will be required
.
.
Model No. Output Volts Control Length Weight Guard Guard
(w) (mm) (kg) Quantity Length
SWD-A-3000-2 3000 230 5-30deg adj stat 1440 12.4 SWG-5 1600
Bush Nelson convector
heater
9. Timings
Lead time - 3 weeks
Standard installation - 7 days
Maximum workload - 12 sites a month
Day 1
Day 1-2 Bolts
Day 3 - Steel frame
Day 3 - Polycarbonate roof
Day 5 – Hormann Doors
Day 6 - completed structure
Day 6 - completed structure
Acoustic Properties of Individual
Component Parts
-Doors
-Roof
16mm Multiwall Polycarbonate Roof Cladding
-Walls
-Glazing
Alternative 6mm solid polycarbonate in lieu of glazing
Alternative EPS core composite cladding in lieu of glazing
For Free Survey & Estimate Contact:
Alex Galanis Will Newberry
Sales Director Area Sales Manager
Cannon Lane Cannon Lane
Tonbridge, Kent TN9 1PP Tonbridge, Kent TN9 1PP
ENGLAND ENGLAND
Tel: +44 (0)1732 351358 Tel: +44 (0)1732 351358
Direct: +44 (0)1732 378321 Direct: +44 (0)1732 378333
Mobile: +44 (0)77785 227358 Mobile: +44 (0)7785 227359
Fax: +44 (0)1732 770563 Fax: +44 (0)1732 770563