EP 1110-1-29

31 Aug 01

Appendix B

Analytical Data Acceptance Criteria for Lead-Based Paint Hazard Clearance Activities







Table B-1



DATA ATTRIBUTE ACCEPTANCE LIMITS

Frequency SINGLE WIPE COMPOSITE WIPE PAINT CHIP SOIL



INDEPENDANT CALIBRATION Within  10% of Known Value Within  10% of Known Value Within  10% of Known Value Within 10% of Known Value

VERIFICATION (ICV)

Once per Day

INITIAL CALIBRATION BLANK (ICB) Absolute Value Not More Than Absolute Value Not More Than Absolute Value Not More Than Absolute Value Not More Than

At the Beginning of Run 10% of the Regulatory Limit or 10% of the Regulatory Limit or 10% of the Regulatory Limit or 10% of the Regulatory Limit or

Minimum Level of Concern Minimum Level of Concern Minimum Level of Concern Minimum Level of Concern

CONTINUING CALIBRATION Within  15% of Known Value for Within  15% of Known Value for Within  15% of Known Value for Within  15% of Known Value for

VERIFICATION CCV) ICP or FAAS; Within  20% for ICP or FAAS; Within  20% for ICP or FAAS; Within  20% for ICP or FAAS; Within  20% for

Beginning and End of Run and Every 10 GFAA GFAA GFAA GFAA

Samples or as specified in the SOP

INTERFERENCE CHECK SAMPLE (ICS) Within 20% of Known Value Within 20% of Known Value Within 20% of Known Value Within 20% of Known Value

Beginning and End of Run or Twice Every

Eight Hours

CONTINUING CALIBRATION BLANK Absolute Value not More Than Absolute Value not More Than Absolute Value not More Than Absolute Value not More Than

(CCB) 10% of Regulatory Limit of Level 10% of Regulatory Limit of Level 10% of Regulatory Limit of Level 10% of Regulatory Limit of Level

After each ICS and CCV of Concern of Concern of Concern of Concern

LABORATORY CONTROL SAMPLE (LCS) Within  20% of Known Value Within  20% of Known Value Within  20% of Known Value Within  20% of Known Value

One per 20 Samples or Batch-Minimum

Frequency 5%

MATRIX SPIKE SAMPLE (MSS) Within 25% of Calculated Value Within 25% of Calculated Value Within 25% of Calculated Value Within 25% of Calculated Value

One per 20 Samples or Batch-Minimum

Frequency 5%

DUPLICATE FIELD SAMPLE (DFS) Within 25% Relative Percent Within 25% Relative Percent Within 25% Relative Percent Within 25% Relative Percent

One per 20 Samples or Batch-Minimum Difference (RPD) Difference (RPD) Difference (RPD) Difference (RPD)

Frequency 5%

MATRIX BLANK (MB) Absolute Value Not More Than Absolute Value Not More Than Absolute Value Not More Than Absolute Value Not More Than

One per 20 Samples or Batch-Minimum 10% of Regulatory Limit of Level 10% of Regulatory Limit of Level 10% of Regulatory Limit of Level 10% of Regulatory Limit of Level

Frequency 5% of Concern of Concern of Concern of Concern

Adapted from Table 1, EPA NLLAP Laboratory Quality System Requirements (LQSR) Revision 2.0, August 1, 1996.







B-1



Related docs
Other docs by ajizai
agc
Views: 1  |  Downloads: 0
Bilaga-10-Invitation-press-FKG
Views: 0  |  Downloads: 0
UnderGrd-1
Views: 0  |  Downloads: 0
Interactiv
Views: 0  |  Downloads: 0
business_toc
Views: 0  |  Downloads: 0
Problems - Welcome to web.gccaz.edu
Views: 0  |  Downloads: 0
student-images-upload
Views: 0  |  Downloads: 0
By registering with docstoc.com you agree to our
privacy policy

You are almost ready to download!

You are almost ready to download!