E X T RACT 83







FAN TYPE FAN LOCATION MAX PAGE

PERFORMANCE



MEVDC INLINE DUCT 98l/s 84



MEVAC INLINE DUCT 95l/s 88



GENIE DCE WALL/WINDOW/CEILING 31l/s 94



GENIE DC WALL/WINDOW/CEILING 31l/s 100



GENIE WALL/WINDOW/INLINE 25l/s 106



GENIE NKF1 WALL 70l/s 112



SLIMAIRE SINGLE SPEED WALL/CEILING 82l/s 118



SLIMAIRE TWIN SPEED WALL/WINDOW/CEILING 82l/s 122



COOKERHOOD WALL 117l/s 126



ACOUSTIC VENTILATION EXTERNAL WALL 128









nuaire.co.uk 83

EXTRAC T

MEV DC

TEC HNI C A L I NFO R MATI O N









M E VD C M ULT I P O I NT E X TRACT



A QUIET, ENERGY EFFICIENT, LOW DEPTH CENTRAL EXTRACT SYSTEM.

SAP Q RECOGNISED.









84 029 2085 8200

EXTR AC T

MEV DC

TEC H NIC A L INFO R MATI O N









B E NE F I T S



MEETS BUILDING REGULATIONS QUICK INSTALLATION ADDED STRENGTH

SAP Appendix Q recognised. Part F&L - England & Unique locating bracket enables the units to be ABS moulded case & lid provides longer life and a

Wales. Scottish technical handbook (BRE398 fixed in any plane, quickly and efficiently at either more robust unit.

referenced). Technical booklet K1998. 1st fix or 2nd fix stage.

ADDITIONAL OPTIONS

LOW DEPTH, HIGH PERFORMANCE REMOTE FAILURE INDICATOR Run on timer, humidistat, G2 filter together with a

Only 190mm deep & up to 98l/s. Visual and audible failure indicator. range of round and rectangular spigot and damper

Code: ES-AVI / ES-OPUS-RFI. kits.

MOST EFFICIENT

Latest DC motors provide high performance with EASY COMMISSIONING WARRANTY

low SFP within their respective class. Ecosmart ‘dial a duty’ option allows for infinitely 5 year warranty for peace of mind.

variable speed selection allowing for exact design

QUIETEST SOLUTION selection. Basic, cost effective model also available.

Advanced motor and impeller technology with Code - MEVDC2. Contact Nuaire’s technical

acoustic lined lid (fully lined case option available) EASY MAINTENANCE team 02920 858200 for further information.

provide one of the quietest options. Easy to access for optional filters for quick and easy

maintenance.



FLEXIBLE SOLUTION

Unit can be fixed horizontally or vertically.









Dial a duty. (Optional). Simple fixing bracket.









Acoustically lined lid. (optional case lining available). Easy access to filter. (Optional).







Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 85

EXTRAC T

MEV DC

TEC HNI C A L I NFO R MATI O N









PERFORMANCE - MEVDC Casing



MEVDC Multi Point Extract

Tested in duct



600 V

ISO 5801 2007







500

Fan Static Pressure (Pa)









400

Code description (example)



300 MEVDC - ES G2 L H D4

4

| | | | | |

200 1 2 3 4 5 6

2 3



1

100 1. DC motor type

2. Ecosmart ‘Dial a duty’ (optional)

3. G2 filter (optional)

0

0 20 40 60 80 100 120 4. Lined case (optional)

Air volume flow rate (l/s)

5. Humidistat (optional)

6. D4 damper kit (optional)

Note: Above are variable speeds, not set speeds.



MEVDC



E L E CT R I C AL & S OU N D



Curve Power Consumption FLC Open inlet sound power levels dB re 1pW Breakout Noise level

Watts Amps 63 125 250 500 1K 2K 4K 8K dBA@3m

1 11 0.14 39 39 44 36 31 22 21 18 19

2 21 0.19 40 42 46 41 37 28 24 18 27

3 35 0.25 43 43 50 46 41 31 28 27 31

4 52 0.37 45 44 54 52 44 35 31 27 34



Note: above sound level figures are for fully lined unit. Unit has a soft start feature as standard therefore the starting current is the same as the full load current.

Step curves are for information purposes only and are not individual units. The electrical and sound information in the table is nominal.

Note: dBA figures are calculated based on hemi-spherical propagation.





S A P A PPE N DIX Q T E S T R E S U LT S OPTIONAL EXTRAS



Application Specific fan power Energy Saving Trust Optional extras: Code MEVDC

(W/l/s) Best Practice Compliant Ecosmart Dial ‘a’ duty ES G

MEV-DC MEVDC-ES Run on timer R G

Kitchen + 1 wetroom 0.35 0.34 Yes G2 filter G2 G

Kitchen + 2 wetrooms 0.30 0.31 Yes *G4 filter (for MEV-SVS application) G4 G

Kitchen + 3 wetrooms 0.31 0.33 Yes Acoustic lining (full case) L G

Kitchen + 4 wetrooms 0.33 N/A Yes Humidistat H G

Kitchen + 5 wetrooms 0.38 N/A Yes *Please refer to page 2.10

Spigot/damper kits (Choose from S1-D4)

Kit 1 - 4 x 100 circular & 2 x 125 circular spigots S1 G

Kit 2 - 6 x rectangular spigots 110 x 54mm S2 G

Kit 3 - 6 x rectangular dampers 110 x 54mm D3 G

Kit 4 - 4 x 100 & 2 x 125 circular damper D4 G

Note – unless spigot kit is specified, a default kit comprising of 4 x 100 and

2 x 125mm spigots will be included.





86 029 2085 8200

EXTR AC T

MEV DC

TEC H NIC A L INFO R MATI O N









DIMENSIONS (MM) - MEVDC

Mounting bracket

Single screw unit fixing









10

SIDE VIEW END VIEW

125 ø









190

Cable entry 20mm Removable panel

containing filter access

VIEW WITH ACCESS PANEL REMOVED MOUNTING BRACKET TOP VIEW

50

Bracket fixing 4 holes 7.5 dia.









140

350









Filter

170







3









490







WIRING - MEVDC



Unit serving Bathroom only Unit Serving Kitchen and two Bathrooms

Fan Fan

Unit Unit



MAINS MAINS

230V N N 230V N N

50Hz 50Hz

L L L L

Fuse 2A Fuse 2A Room

Optional SL lights SL

lamp 3 Pole 3 Pole

isolator Light

switches isolator

Remote/light switch (Double

Pole)







Unit Serving Kitchen and Bathroom Kitchen switch

Fan

Unit



MAINS

230V N N

50Hz

L L

Fuse 2A Room

light SL

Light 3 Pole

switch isolator

(Double

Pole)



Kitchen switch









Download specification from www.nuaire.co.uk/specifications

F

nuaire.co.uk 87

EXTRAC T

MEVAC

TEC HNI C A L I NFO R MATI O N









M E VAC M ULT I P O I NT E X T RACT



QUIET, MULTI-CONNECTION, LOW DEPTH CENTRAL EXTRACT SYSTEM.









88 029 2085 8200

EXTR AC T

MEVAC

TEC H NIC A L INFO R MATI O N









B E NE F I T S



MEETS BUILDING REGULATIONS QUICK INSTALLATION ADDED STRENGTH

Part F - England & Wales. Scottish technical Unique locating bracket enables the units to be ABS moulded case & lid provides longer life and a

handbook (BRE398 referenced). Technical booklet fixed in any plane, quickly and efficiently at either more robust unit.

K1998. 1st fix or 2nd fix stage.

ADDITIONAL OPTIONS

LOW DEPTH, HIGH PERFORMANCE EASY MAINTENANCE Run on timer, humidistat, G2 filter together with a

Only 190mm deep and up to 95l/s (AC). Easy to access for optional filters for quick and easy range of round and rectangular spigot and damper

maintenance. kits.

QUIETEST SOLUTION

Advanced motor and impeller technology with FLEXIBLE SOLUTION WARRANTY

acoustic lined lid (fully lined case option available) Unit can be fixed horizontally or vertically. 3 year warranty for peace of mind.

provide one of the quietest options.









Easy access to filter. (Optional).









Acoustically lined lid. Simple fixing bracket.







Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 89

EXTRAC T

MEVAC

TEC HNI C A L I NFO R MATI O N









PERFORMANCE - MEVAC Casing

MEVAC Multi Point Extract

400

Tested in duct



V

ISO 5801 2007

350







300





Code description (example)

250

Fan Static Pressure (Pa)









MEVAC - 6S R G2 S2

200 | | | | |

1 2 3 4 5

150

1. AC motor type

2. Adjustable speed (optional)

100

3 4 3. Run on timer (optional)

4. G2 Filter (optional)

2

50 5. S2 Spigot kit (optional)

1





0

0 10 20 30 40 50 60 70 80 90 100

Air volume flow rate (l/s)

Note: Above are variable speeds, not set speeds.



MEVAC



E L E CT R I C AL & S OU N D



Curve Power Consumption FLC Open inlet sound power levels dB re 1pW Breakout Noise level

Watts Amps 63 125 250 500 1K 2K 4K 8K dBA@3m

1 14 0.15 43 37 42 35 32 23 22 26 20

2 26 0.2 46 43 52 45 45 37 27 26 32

3 37 0.22 41 40 57 51 51 43 35 28 37

4 59 0.25 45 45 66 58 59 51 45 37 45



Note: above sound level figures are for lid lined unit only.Unit has a soft start feature as standard therefore the starting current is the same as the full load current.

Please note step curves are for information purposes only and are not individual units. (The units has 4 speeds and uses, 2 from 4 speeds (default speeds are 1 and 3). Optional 6S model).

Note: dBA figures are calculated based on hemi-spherical propagation. The electrical and sound information in the above table is nominal.



PRODU CT FE AT U R E S OPTIONAL EXTRAS



Code MEVAC Optional extras: Code MEVAC

Features: Adjustable speed option 6S G

AC motor G Run on timer R G

2 speed (fixed) G G2 filter G2 G

Mounting brackets G *G4 filter (for MEV-SVS application) G4 G

Acoustic lined lid G Acoustic lining (full case) L G

Note – unless spigot kit is specified, a default kit comprising of 4x100 & 2x125mm *Please refer to page 2.10

spigots will be included.

Spigot/damper kits (Choose from S1-D4)

Kit 1 - 4 x 100 circular & 2 x 125 circular spigots S1 G

Kit 2 - 6 x rectangular spigots 110 x 54mm S2 G

Kit 3 -6 x rectangular dampers 110 x 54mm D3 G

Kit 4 - 4 x 100 & 2 x 125 circular damper D4 G

Note – unless spigot kit is specified, a default kit comprising of 4 x 100 and

2 x 125mm spigots will be included.



90 029 2085 8200

EXTR AC T

MEVAC

TEC H NIC A L INFO R MATI O N









DIMENSIONS (MM) - MEVAC

Mounting bracket

Single screw unit fixing









10

SIDE VIEW END VIEW

125 ø









190

Cable entry 20mm Removable panel

containing filter access

VIEW WITH ACCESS PANEL REMOVED MOUNTING BRACKET TOP VIEW

50

Bracket fixing 4 holes 7.5 dia.









140

350









Filter

170









K



490









WIRING - MEVAC

Unit Serving Kitchen and Bathroom Unit Serving Kitchen and Utility and Bathroom



230V 230V

1ph 1ph

N N N N

50Hz 50Hz

supply L L supply L L

Fuse 2A max. Room Fuse 2A max. Room

light SL light SL

Light switch Light switch

bathroom bathroom

(double pole) (double pole)

Kitchen switch

Kitchen switch Utility switch









Unit Serving Kitchen and two Bathrooms



230V

1ph N

50Hz N

supply L L

Fuse 2A max.

F Room

lights SL



Light switch

bathroom/wc

(double pole)







Kitchen switch









Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 91

EXTRAC T

MEV DC

TEC HNI C A L I NFO R MATI O N









CONSULTA NT S SP E CI F I C ATION



MEVDC UNIT

The unit shall be designed specifically for incorporation within a system designed The unit shall incorporate electrical connections to allow for the unit’s "boost"

to comply with the requirements of Part F Building Regs. Ducting and grilles airflow to be triggered by any one or combination of the following:

forming part of the system are specified elsewhere.

1. A switched live signal, 230V.

The unit shall be manufactured by a BSI Registered Firm with ISO 9000 2. A remote speed control.

certification. The unit’s casing shall be of ABS, Moulded plastic with a part lined

lid of high density class "O" flame retardant acoustic insulation designed to limit When the unit "boost" has been triggered by the switched live signal the unit

noise breakout from the unit to a maximum of 34dBA (DC model) - hemi- shall incorporate an adjustable "run on" facility (optional).

spherical radiation.

The MEVDC unit shall be offered with a 5 year warranty.

The unit shall incorporate a low profile single point mounting bracket for

horizontal or vertical mounting of the unit. When installed the unit shall not MEVDC-ES (optional Ecosmart control).

project any more than 190mm from the surface onto which it installed.

The unit shall be provided with a casing mounted, easily accessible, factory

Air discharge from the unit shall be via a tapered spigot for easy connection to connected, user control panel providing the following airflow control settings:

ducting. The unit shall be capable of multiple air inlets formatting. The unit

casing shall have the facility to allow the connection, via tapered air inlet spigots (a) Setting of the unit’s "background" design airflow rate via a calibrated dial

supplied with the unit of up to 4 No. 100 mm diameter and 2 No. 125mm labelled between 10 and 90 litres/second.

diameter air inlet ducts. (b) Setting of the units "boost" design airflow rate via a calibrated dial labelled

between 10 and 90 litres/second.

The unit shall incorporate a quick release, access panel for easy maintenance if (c) Setting of the "boost" airflow run on time via a calibrated dial labelled

filter is fitted. Replacement filter codes are G2 = 776717 and G4 = 776718. between 0 and 60 minutes.





The unit shall be constructed with one removable panel allowing full The unit shall incorporate a factory fitted, automatic constant volume control

maintenance access. The unit shall incorporate a fully speed adjustable (note: facility to ensure as far as is practical that the pre-set "background" and "boost"

stepped speed control shall not be acceptable) low energy, high efficiency DC design airflows are maintained, within the capabilities of the unit’s performance

fan/motor assembly with sealed for life bearings designed to operate levels.

continuously at a pre-set "background" design airflow rate with the ability to

increase to a pre-set "boost" design airflow rate as and when required. It shall The control panel shall also incorporate a fan status indicator light and the

operate up to an ambient temperature of 40°C and be fitted with a one shot facility to check and provide visual indication that the installed unit is actually

thermal overload protective device. achieving the duties set at the dial.





The impeller should be a centrifugal backward curved type, dynamically

balanced mounted directly onto the motor.









92 029 2085 8200

EXTR AC T

MEVAC

TEC H NIC A L INFO R MATI O N









CO NSULTA NT S SP E CI FIC ATION



MEVAC UNIT

The unit shall be designed specifically for incorporation within a system designed

to comply with the requirements of Part F Building Regs. Ducting and grilles

forming part of the system are specified elsewhere.





The unit shall be manufactured by a BSI Registered Firm with ISO 9000

certification. The unit’s casing shall be of ABS, Moulded plastic with a part lined

lid of high density class "O" flame retardant acoustic insulation designed to limit

noise breakout from the unit to a maximum of 45dBA (AC model) - hemi-

spherical radiation.





The unit shall incorporate a low profile single point mounting bracket for

horizontal or vertical mounting of the unit. When installed the unit shall not

project any more than 190mm from the surface onto which it installed.





Air discharge from the unit shall be via a 125mm diameter tapered spigot for

easy connection to ducting. The unit shall be capable of multiple air inlets

formatting. The unit casing shall have the facility to allow the connection, via

tapered air inlet spigots supplied with the unit, of up to 4 No.100 mm diameter

and 2 No. 125mm diameter air inlet ducts.





The unit shall incorporate a quick release, access panel for easy maintenance if

filter is fitted.





The AC version should be a capacitor run external rotor motor capable of 2 fixed

speeds. 230V 50Hz AC with ball race bearings, greased for life. It shall operate up

to an ambient temperature of 40°C and be fitted with a one shot thermal

overload protective device.





The impeller should be a centrifugal backward curved type, dynamically

balanced mounted directly onto the motor.





The unit shall incorporate electrical connections to allow for the unit’s "boost"

airflow to be triggered by a switched live signal.





The MEVAC unit shall be offered with a 3 year warranty.









Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 93

EXTRAC T

G ENI E DC E

TEC HNI C A L I NFO R MATI O N









G E NI E - D CE D E CE NT RA L I SED M ECHANIC AL EXTRACT FANS (dMEV)



MEET YOUR CODE FOR SUSTAINABLE HOMES REQUIREMENT WITH

DECENTRALISED MEV. SAP APPENDIX Q RECOGNISED.









94 029 2085 8200

EXTR AC T

G ENI E DC E

TEC H NIC A L INFO R MATI O N









B E NE F I T S



MEETS REGULATIONS EASY COMMISSIONING IDEAL FOR HIGH RISE BUILDINGS

SAP Appendix Q recognised. Commission in seconds with a dial ‘a’ duty feature. Fan is capable of maintaining the set flow rate to

New Part F-ventilation in buildings (System 3) within 5% even under wind load conditions.

continuous mechanical extract. POWERFUL YET COMPACT

New Part L - conservation of fuel and power. Improved performance over the AC fan, up WARRANTY

BRE digest 398. to 30l/s for the bathroom fan. 5 year warranty with extended warranty options.

Meets minimum fan power in ‘Domestic Building

Services Compliance Guide’ (2010 edition). COMPLETE USER SAFETY

Flame retardant construction and Genie 12V model

ECONOMICAL is IPX4 rated.

Daily running cost is 80% lower than AC fans due

to low wattage motor technology. WIDE RANGE OF OPTIONS

Range is ideal for all applications including

SILENT RUNNING bathroom, en-suite, kitchen and utility areas.

Utilising market leading motor and impellor Available in 230V or 12V with a choice of controls

technology to produce the quietest of fans with a for boost speed.

maximum of 35dBA@3m.

FLEXIBLE SOLUTION

QUICK AND EASY INSTALLATION Mount anywhere. Install in the wall, ceiling or

AND MAINTENANCE window. Low profile recess option is available.

Clip in push fit components ensure reduced time on (Window kit code – WINKIT).

site.

EASY TO CLEAN

Simply remove filter and wash in warm soapy

water.









CLIP IN PUSH FIT COMPONENTS MOUNTING OPTIONS





Easily removed fan/motor assembly. Removable electronic control module.









Semi-recessed mounted - wall.

Plug-in wiring connector.









Surface mounted - wall.









Semi-recessed mounted - ceiling.







Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 95

EXTRAC T

G ENI E DC E

TEC HNI C A L I NFO R MATI O N









PERFORMANCE GENIE-DCE EXTRACT FANS Casing

Genie-DCE Extract Fans

120

V









100 ISO 5801

BS848 Part 1 2007







Full speed - Boost

80

Fan Static Pressure (Pa)









60

Note: see window kit for window version.



Kitchen (13l/s)

40 Code descriptions



GENIE-DCE-H12

20

Bathroom/ | | | |

wet room (8l/s)

1 2 3 4

0 1. Genie range

0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 20.0 22.0 24.0 26.0 28.0 30.0 32.0 2. Low wattage DC motor

3. Control function

Air volume flow rate (l/s) 4. Voltage





GENIE-DCE FANS RANGE AND CONTROL FUNCTION

Sound levels

Unit Trickle-Bathroom Trickle-Kitchen Full speed/Boost Mounting Operating

Code dBA@3m dBA@3m dBA@3m Type Voltage Control function



GENIE-DCE 18 20 34.5 surface 230 continuous ventilation at imperceptible noise level with boost

duty activated via light switch or remote fan switch (by others)

or integral pullcord.

With adjustable run-on timer (1–60 mins).



GENIE-DCE-12 18 20 34.5 surface 12 12V continuous ventilation at imperceptible noise level with

boost duty activated via light switch or remote fan switch

(by others) or integral pullcord. With adjustable run-on timer

(1–60 mins). Purpose made transformer.



*GENIE-DCE-H 18 20 34.5 surface 230 continuous ventilation with boost via integral humidistat,

pull cord or light switch (by others).

With adjustable run-on timer (1–60 mins).



*GENIE-DCE-H12 18 20 34.5 surface 12 12V continuous ventilation with boost via integral humidistat,

pull cord or light switch (by others).

With adjustable run-on timer (1–60 mins).

Purpose made transformer.



*Recommended for optimum humidity and odour control. Note: Code for Genie Window kit is WinKit.







SAP APPENDIX Q TEST RESULTS *SYSTEMS WITH RIGID DUCTING ONLY

Fan Specific Flow Flow rate % Reduction

Unit speed fan power rate - wind of total

configuration Location setting (W/l/s) (l/s) condition (l/s) flow rate (%)

In room Kitchen Kitchen 0.28 14.4 13.8 4

Wet room Bathroom 0.28 9.1 8.7 4

Through wall Kitchen Kitchen 0.23 15.1 14.8 2

Wet room Bathroom 0.23 8.2 8.2 0









96 029 2085 8200

EXTR AC T

G ENI E DC E

TEC H NIC A L INFO R MATI O N









WINDOW MOUNTING OPTION Top three shutter blades temporarily

removed during installation. Window 4mm to 32mm thick.

The window mounting kit is designed for mounting the unit into

Cut 125mm hole for fan.

windows 4mm to 32mm thick using a 125mm dia hole.

Electrical cable passed

For further information please refer to Installation document 671504. through the inner gasket

and fed into case.





Unit case.





Outer shutter

frame.



Outer gasket, spigot moulding

locates in window aperture.



Inner gasket, spigot moulding

locates in window aperture.



Approximately 150mm of

cable for final wiring.

DIMENSIONS GENIE-DCE FAN UNIT (MM)



73 126



18 71





80





200 98 OD







173



208

18



Recessed mounting Overall width when

flange provided 55 Recessed only







WIRING - 230V AND 12V FANS



230V units via Remote Switch 3 12V units via Remote Switch 3

1 1

230V 12V

GENIE-DCE N GENIE-DCE-12 N N N

GENIE-DCE-H GENIE-DCE-H12

L L L L

N E N E

L 2 2

L SL 2

Fuse 2 amp Fuse 2 amp Fan

Transformer

The switched Live signal to terminal 2 must be at 230V to enable the fan

and at 0V to stop the fan after the adjustable timed overrun period.

Induced voltages in the switched live field wiring can keep the unit running.



230V units via Pullcord 3 12V units via Pullcord 3

1 230V 12V 1

GENIE-DCE N GENIE-DCE-12 N N N N

N Fuse 2 amp

GENIE-DCE-H GENIE-DCE-H12

L L L L L L

Fuse 2 amp E E

As wiring for remote switch

2 excluding switch. 2

Fan

Transformer







Warning: For EMC compliance the 12V cable should not be fitted within 50mm of 230V or other cables or on the same tray/ trunking

if made of metal. The earth connection in the transformer enclosure should not be used. No earth connection should be made to the

12V fan unit.







Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 97

EXTRAC T

G ENI E DC E

TEC HNI C A L I NFO R MATI O N









POWER CONSUMPTION



230V 12V

Unit input power (watts) 12 16

Full load current (amps) .14 .085

Starting Current (amps) .14 .085









12V TRANSFORMER DETAILS



Transformer Installation notes for wiring sizes Transformer to fan (12V units only)

It is important to note that the size of wire used between the transformer Cable run (max. 10 metres) Cable size

and the fan unit can have an adverse effect on the units performance if the Up to 2m 0.75mm sq.

following table is not adherred to. Up to 4m 1.00mm sq.

Mains Supply: (230V) 0.5mm sq. Up to 6m 1.50mm sq.

Up to 10m 2.50mm sq.







12V TRANSFORMER DIMENSIONS (MM)



Side view End view

147mm 85mm

64mm

32mm









Plan view







Cover fixings

85mm









View inside with cover removed

12V OUTPUT N









230V SUPPLY

SWL N L

FAN

L

2









12V supply Mains supply

to fan 230V 1ph 50Hz









98 029 2085 8200

EXTR AC T

G ENI E DC E

TEC H NIC A L INFO R MATI O N









CO NSULTA NT S SP E CI FIC ATION



GENIE-DCE KITCHEN AND WET ROOM FAN

The unit shall be manufactured by Nuaire. Fan status indication to be visible on front of unit, with flashing LED to show fan

failure.

Unit shall be SAP Appendix Q recognised.

Plastic casing to be manufactured from flame retardant materials.

Under wind load conditions the unit will be capable of maintaining it’s set The unit shall be designed for quietest operation to ensure occupant satisfaction.

flowrate to within 5%.

The unit shall incorporate electrical connections to allow for the unit’s “boost”

The unit shall be surface mountable incorporating a push fit, washable filter with airflow to be triggered by either pull-cord or switched live.

an area of 23,750mm2 and capable of conversion, if necessary, to semi-recessed

format using flange supplied or window mounting format using optional fixing kit. The unit shall be supplied with a 5 year warranty.





Unit noise level shall not exceed 20dBA @3m for kitchens and 18dBA for wet

rooms (normal running).





The unit shall incorporate an injection moulded forward curved centrifugal impeller.





The impeller shall be directly driven by a low energy, high efficiency 12V DC

motor, fitted with sealed, self lubricating ball bearings.





Motors shall have locked rotor protection to prevent overheating in the event of

fan failure.





The fan/motor assembly and the unit control assembly shall be capable of

replacement as "plug in" modules without disturbing the field wiring.





Each unit is capable of being set to comply with new edition (2010).

Part F – ventilation building regulations for (System 3) continuous mechanical

extract (MEV) and new edition (2010) Part L - conservation of fuel and power.





Units shall be fitted with a run-on timer facility (1-60 minutes), from switched

live signal only.





Unit can comply with BRE digest 398 under continuous mechanical extract

ventilation.





Meets the minimum fan power requirement of 0.5w/l/s in the in ‘Domestic

Building Services Compliance Guide’ (2010 edition).









Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 99

EXTRAC T

G ENI E DC

TEC HNI C A L I NFO R MATI O N









G E NI E - D C UNI V E RSA L SURFACE MOUNTED EXTRACT FANS



LATEST ENERGY SAVING TECHNOLOGY APPLIED TO

PROVEN GENIE DESIGN.









100 029 2085 8200

EXTR AC T

G ENI E DC

TEC H NIC A L INFO R MATI O N









B E NE F I T S



MEETS REGULATIONS EASY COMMISSIONING FLEXIBLE SOLUTION

New Part F & L under (System 1) Intermittent Fan speed is fully adjustable. Mount anywhere. Install in the wall, ceiling or

extract fans. window. Low profile recess option is available.

Scottish building regs for intermittent bathroom ECONOMICAL (Window kit code – WINKIT).

extract fans. Daily running cost is 80% lower than AC fans due

BRE digest 398 under continuous mechanical to low wattage motor technology. EASY TO CLEAN

extract ventilation. Simply remove filter and wash in warm soapy

Meets minimum fan power requirement in POWERFUL YET COMPACT water.

‘Domestic Building Services Compliance Guide’ Improved performance over the AC fan, up to 30l/s

(2010 edition). for the bathroom fan. IDEAL FOR HIGH RISE BUILDINGS

Fan is capable of maintaining the set flow rate to

SILENT RUNNING COMPLETE USER SAFETY within 5% even under wind load conditions.

Utilising market leading motor and impeller Flame retardant construction and Genie 12V model

technology to produce the quietest of fans. is IPX4 rated. WARRANTY

5 year warranty with extended warranty options.

QUICK AND EASY INSTALLATION AND WIDE RANGE OF OPTIONS

MAINTENANCE Range is ideal for all applications including

Clip in push fit components ensure reduced time on bathroom, en-suite, kitchen and utility areas.

site. Replace your Genie internal components with Available in 230V or 12V with a choice of controls.

latest energy saving technology, low wattage

components.









CLIP IN PUSH FIT COMPONENTS MOUNTING OPTIONS





Easily removed fan/motor assembly. Removable electronic control module.









Semi-recessed mounted - wall.

Plug-in wiring connector.









Surface mounted - wall.









Semi-recessed mounted - ceiling.







Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 101

EXTRAC T

G ENI E DC

TEC HNI C A L I NFO R MATI O N









PERFORMANCE GENIE-DC EXTRACT FANS Casing

Genie-DC Extract Fans

120

V









100 ISO 5801

BS848 Part 1 2007







Full speed - Boost

80

Fan Static Pressure (Pa)









60

Note: see window kit for window version.





40 Minimum speed

Background

Code descriptions

Ventilation

GENIE-DC-H12

20

| | | |

1 2 3 4

0 1. Genie range

0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 20.0 22.0 24.0 26.0 28.0 30.0 32.0 2. Low wattage DC motor

3. Control function

Air volume flow rate (l/s) 4. Voltage







GENIE-DC FANS RANGE AND CONTROL FUNCTION



Unit Min speed Full speed/Boost Mounting Operating

Code dBA@3m Type Voltage Control function



GENIE-DC-S 16.0 34.5 surface 230 on/off control via light switch link or remote fan switch (by others) with

adjustable run-on timer (1–60 mins).





GENIE-DC-S12 16.0 34.5 surface 12 12V on/off control via light switch link or remote fan switch (by others) with

adjustable run-on timer (1–60 mins).

Purpose made transformer.



*GENIE-DC-H 16.0 34.5 surface 230 on/off control via light switch link or remote fan switch (by others)

or via integral pull cord with automatic override by integral adjustable

humidistat.



*GENIE-DC-H12 16.0 34.5 surface 12 12V on/off control via light switch link or remote fan switch (by others)

or via integral pull cord with automatic override by integral adjustable

humidistat. Purpose made transformer.



GENIE-DC-X 16.0 34.5 surface 230 continuous ventilation at imperceptible noise level with boost duty

activated via light switch or remote fan switch (by others) or integral

pullcord. With adjustable run-on timer (1–60 mins).



GENIE-DC-X12 16.0 34.5 surface 12 12V continuous ventilation at imperceptible noise level with boost duty

activated via light switch or remote fan switch (by others) or integral

pullcord. With adjustable run-on timer (1–60 mins). Purpose made transformer.



*GENIE-DC-XH 16.0 34.5 surface 230 universal fan, continuous ventilation with boost via integral humidistat,

pull cord or light switch (by others).

With adjustable run-on timer (1–60 mins).



*GENIE-DC-XH12 16.0 34.5 surface 12 universal fan, 12V continuous ventilation with boost via integral humidistat,

pull cord or light switch (by others). With adjustable run-on timer (1–60 mins).

Purpose made transformer.



*Recommended for optimum humidity and odour control. Note: Code for Genie Window kit is WinKit.









102 029 2085 8200

EXTR AC T

G ENI E DC

TEC H NIC A L INFO R MATI O N









WINDOW MOUNTING OPTION Top three shutter blades temporarily

removed during installation. Window 4mm to 32mm thick.

The window mounting kit is designed for mounting the unit into

Cut 125mm hole for fan.

windows 4mm to 32mm thick using a 125mm dia hole.

Electrical cable passed

For further information please refer to Installation document 671504. through the inner gasket

and fed into case.





Unit case.





Outer shutter

frame.



Outer gasket, spigot moulding

locates in window aperture.



Inner gasket, spigot moulding

locates in window aperture.



Approximately 150mm of

cable for final wiring.

DIMENSIONS GENIE-DC FAN UNIT (MM)



73 126



18 71





80





200 98 OD







173



208

18



Recessed mounting Overall width when

flange provided 55 Recessed only





WIRING - 230V AND 12V FANS



230V units via Remote Switch 3 12V units via Remote Switch 3

1

230V 12V 1

GENIE-DC-S N GENIE-DC-S12

GENIE-DC-H GENIE-DC-X12 N N N

GENIE-DC-X L GENIE-DC-H12 L L L

GENIE-DC-XH N E GENIE-DC-XH12 N E

L 2

L SL 2 2

Fuse 2 amp

Fuse 2 amp Fan

Transformer

The switched Live signal to terminal 2 must be at 230V to enable the fan

and at 0V to stop the fan after the adjustable timed overrun period.

Induced voltages in the switched live field wiring can keep the unit running.



230V units via Pullcord 3 12V units via Pullcord 3

1 230V 12V 1

GENIE-DC-H N GENIE-DC-X12 N N N N

N Fuse 2 amp

GENIE-DC-X GENIE-DC-H12

L L L L L L

GENIE-DC-XH GENIE-DC-XH12

Fuse 2 amp E E

As wiring for remote switch

2 excluding switch. 2

Fan

Transformer









Warning: For EMC compliance the 12V cable should not be fitted within 50mm of 230V or other cables or on the same tray/ trunking

if made of metal. The earth connection in the transformer enclosure should not be used. No earth connection should be made to the

12V fan unit.







Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 103

EXTRAC T

G ENI E DC

TEC HNI C A L I NFO R MATI O N









POWER CONSUMPTION



230V 12V

Unit input power (watts) 12 16

Full load current (amps) .14 .085

Starting Current (amps) .14 .085









12V TRANSFORMER DETAILS



Transformer Installation notes for wiring sizes Transformer to fan (12V units only)

It is important to note that the size of wire used between the transformer Cable run (max. 10 metres) Cable size

and the fan unit can have an adverse effect on the units performance if the Up to 2m 0.75mm sq.

following table is not adherred to. Up to 4m 1.00mm sq.

Mains Supply: (230V) 0.5mm sq. Up to 6m 1.50mm sq.

Up to 10m 2.50mm sq.







12V TRANSFORMER DIMENSIONS (MM)



Side view End view

147mm 85mm

64mm

32mm









Plan view







Cover fixings

85mm









View inside with cover removed

12V OUTPUT N









230V SUPPLY

SWL N L

FAN

L

2









12V supply Mains supply

to fan 230V 1ph 50Hz









104 029 2085 8200

EXTR AC T

G ENI E DC

TEC H NIC A L INFO R MATI O N









CO NSULTA NT S SP E CI FIC ATION



GENIE-DC BATHROOM FAN

The unit shall be manufactured by Nuaire. Fan status indication to be visible on front of unit, with flashing LED

to show fan failure.

The unit shall incorporate, where necessary, a magnetically latched anti back

draft shutter at the fan rear outlet. (except ‘X’ variants). Humidity detection units will vary speed proportionally with humidity level.





The unit shall be surface mountable incorporating a push fit, washable filter with The unit complies with new edition (2010) Part F-ventilation building

an area of 23,750mm2 and capable of conversion, if necessary, to semi-recessed regulations (for System 1) intermittent extract fans and new edition (2010) Part

format using flange supplied or window mounting format using optional fixing kit. L - conservation of fuel and power.





Unit noise level shall not exceed 35dBA @3m. Meets the minimum fan power requirement of 0.5w/l/s in the ‘Domestic

Building Services Compliance Guide’ (2010 edition).

The unit shall incorporate an injection moulded forward curved centrifugal impeller.

Can comply with Scottish building regs for intermittent bathroom extract.

The impeller shall be directly driven by a low energy, high efficiency

12V DC motor, fitted with sealed, self lubricating ball bearings. Can comply with BRE digest 398 under continuous mechanical extract

ventilation (X-variants).

Motors shall have locked rotor protection to prevent overheating in

the event of fan failure. Plastic casing to be manufactured from flame retardant materials.

The unit shall be designed for quietest operation to ensure occupant satisfaction.

The fan/motor assembly and the unit control assembly shall be capable of

replacement as "plug in" modules without disturbing the field wiring. The unit shall incorporate electrical connections to allow for the unit’s “boost”

airflow to be triggered by either the switched live signal

To prevent over ventilation each unit shall be fitted with fully adjustable speed (‘S’ variants) or pull-cord/switched live (X, H, & XH units)

control. For single speed units one adjustable potentiometer is fitted. For

continuously running fans adjustment can be made to both the continuous and The unit shall be supplied with a 5 year warranty.

boost speeds.





Units shall be fitted with a run-on timer facility (1-60 minutes)

(‘S’ and ‘X’ variants).









Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 105

EXTRAC T

G ENI E

TEC HNI C A L I NFO R MATI O N









G E NI E EX T RACT FA NS



LOW MAINTENANCE, EXTRACT FANS.









106 029 2085 8200

EXTR AC T

G ENI E

TEC H NIC A L INFO R MATI O N









B E NE F I T S



MEETS REGULATIONS COMPLETE USER SAFETY EASY TO CLEAN

Complies with Building Regulations. Flame retardant construction and Genie 12V model Simply remove filter and wash in warm soapy

is IPX4 rated. water.

EXTREMELY QUIET

Utilising market leading AC motors to produce the WIDE RANGE OF OPTIONS WARRANTY

quietest of AC fans. Range is ideal for all applications including 5 year warranty for peace of mind.

bathroom, en-suite kitchen and utility areas.

QUICK & EASY INSTALLATION AND Available in 230v or 12v with choice of controls.

MAINTENANCE

Clip in push fit components ensure reduced time on FLEXIBLE SOLUTION

site. Mount anywhere. Install in the wall, ceiling or

window. Low profile recess option is also available

ECONOMICAL (Window kit code – WINKIT).

Low running costs.









Easily removed plug-in control module. MOUNTING OPTIONS









Semi-recessed mounted - wall.









Surface mounted - wall.









Semi-recessed mounted - ceiling.

Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 107

EXTRAC T

G ENI E

TEC HNI C A L I NFO R MATI O N









PERFORMANCE GENIE EXTRACT FANS Casing

Genie Extract Fans

V



120



ISO 5801

BS848 Part 1 2007

100

Fan Static Pressure (Pa)









Surface and semi-recessed (full speed)

80





Duct mounted (full speed)

60



Note: see window kit for window version.

40

Background ventilation

Code descriptions

mode (X, X12 & MX)

20

GENIE H - 12

0

| | |

0 10 20 30 1 2 3

Air volume flow rate (l/s) 1. Genie range

2. Control function

3. Voltage









GENIE FANS - RANGE AND CONTROL FUNCTION

Mounting Operating

Code dBA@3m type voltage Control function



on/off control via light switch link or remote fan switch (by

GENIE 30 surface 230

others), or integral pullcord (no pullcord on M unit).



GENIE - S 30 surface 230

on/off control via light switch link or remote fan switch (by

GENIE - S12 30 surface 12

others) with adjustable run-on timer (5–30 mins.)

GENIE - MS 30 duct 230



GENIE - H 30 surface 230 on/off control via light switch link or remote fan switch (by

GENIE - H12 30 surface 12 others) or via integral pull cord with automatic override by

integral adjustable humidistat.



*GENIE - X 30 surface 230 continuous background ventilation at imperceptible noise level

*GENIE - X12 30 surface 12 with boost duty activated via light switch or remote fan switch

*GENIE - MX 30 duct 230 (by others) or integral pullcord (no pullcord on MX units).



universal fan, continuous ventilation with boost via integral

*GENIE - XH 30 surface 230

humidistat, pull cord or light switch (by others).

universal fan, 12V continuous ventilation with boost via integral

*GENIE - XH12 30 surface 12

humidistat, pull cord or light switch (by others). Purpose made

transformer.



on/off control via integral occupancy sensor with adjustable

GENIE - PIR 30 surface 230

run on timer (5–30 mins.).





*Recommended for optimum humidity and odour control.

Note: Code for Genie Window kit is WinKit.









108 029 2085 8200

EXTR AC T

G ENI E

TEC H NIC A L INFO R MATI O N









DIMENSIONS (MM) WINDOW MOUNTING

The window mounting kit is designed for mounting

Duct mounted unit

the unit into windows 4mm to 32mm thick using a

73 125

125mm dia hole.

Airflow

For further information please refer to Installation

80 document 671182.



200









175

Surface and semi-recessed units

126

73

18 71



80



200 98 OD





173



208

18

Overall width when

Recessed Recessed only

mounting flange 55

provided







WIRING - GENIE SURFACE MOUNTED FANS



230V units via Remote Switch 3 12V units via Pullcord 3

GENIE 1 GENIE - X12 230V 12V 1

GENIE - S N GENIE - H12 N N N N

GENIE - H GENIE - XH Fuse 2 amp

L L L L L

GENIE - X GENIE - XH12

GENIE - XH N E As wiring for remote switch above, E

L 2 excluding switch. 2

Fuse 2 amp Fan

Transformer

The switched Live signal to terminal 2 must be at 230V to enable the fan

12V units via Remote Switch 3

and at 0V to stop the fan after the adjustable timed overrun period.

GENIE - S12 1

Induced voltages in the switched live field wiring can keep the unit running. 230V 12V

GENIE - X12

N N N

GENIE - H12

230V units via Pullcord GENIE - XH L L L

3

GENIE GENIE - XH12 N E

1

GENIE - H N L SL SL 2

N

GENIE - X Fuse 2 amp

L Fan

GENIE - XH L

Transformer

Fuse 2 amp E

2 WIRING - DUCT MOUNTED FANS

230V units via PIR 3 All units are supplied with a 1.5 mtre length of cable connected to the fan,

GENIE PIR 1 to ease installation without having to part the case and to facilitate

N N connection to a fixed electrical supply, via appropriate switched/fused spur.

L L

Wire coding: Live = L, Neutral = N, Switched live = 2, Earth =

Fuse 2 amp E

2 230V units via Remote Switch

GENIE - M

Fan

GENIE - MX



Warning: For EMC compliance the 12V cable should not be fitted

within 50mm of 230V or other cables or on the same tray/ E

trunking if made of metal.

N

The earth connection in the transformer enclosure should not be

used. No earth connection should be made to the 12V fan unit. L

2 amp 2

f





Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 109

EXTRAC T

G ENI E

TEC HNI C A L I NFO R MATI O N









CONSULTA NT S SP E CI F I C ATION



GENIE EXTRACT FAN

The unit shall be manufactured by Nuaire.





The unit shall be either:

a) Surface mountable incorporating a push fit, washable filter with an area of

23,750mm2 and capable of conversion, if necessary, to semi-recessed format

using flange supplied or window mounting format using optional fixing kit.

b) Duct mountable using integral 100mm diameter spigots and fixing brackets

supplied.





Unit noise level shall not exceed 30dBA@3m (24dBA@3m for duct mounted

unit).





The unit shall incorporate an injection moulded forward curved centrifugal

impeller. The impeller shall be directly driven by a motor fitted with sealed, self

lubricating bearings and thermal overload protection.





The fan/motor assembly and the unit control assembly shall be capable of

replacement as "plug in" modules without disturbing the field wiring.





The unit shall be designed for quietest operation to ensure occupant satisfaction.





The unit shall be supplied with a 5 year warranty.









110 029 2085 8200

ST YL I SH KI TCHEN EXTRACT SOLUTION

F O R USE WITH CENTRAL EXTRACT SYSTEM

( M E V, MVHR & CONSTANT PRESSURE)









This easy to clean 60cm stainless steel cookerhood unit is fitted with

two, washable metallic grease filters for quick and easy maintenance.

The push button located on the front of the unit illuminates the

cooking area and provides a switched live signal to trigger boost

function (when linked to a Nuaire MEV, MVHR or damper system).





• Extraction tube 125mm diameter ducting

Metallic grease filters. • Incorporates a simple boost facility – the light switch

on unit acts as trigger for boost facility



• 2 metallic grease filters



• 2 lights



• 2 year warranty



The Cookerhood does not contain a fan. Extract is via a

separate fan unit e.g. MEVDC, MVHR or Constant Pressure CVD.

Coding: CKRH





Push button for lights and boost signal.









Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 111

EXTRAC T

G ENI E NKF 1

TEC HNI C A L I NFO R MATI O N









G E NI E NKF 1 E X T RACT FA NS



POWERFUL KITCHEN EXTRACT FAN WITH

LOW NOISE AND EASY MAINTENANCE.









112 029 2085 8200

EXTR AC T

G ENI E NKF1

TEC H NIC A L INFO R MATI O N









B E NE F I T S



MEETS REGULATIONS QUICK & EASY INSTALLATION AND FLEXIBLE SOLUTION

Complies with Building Regulations. MAINTENANCE Suitable for surface or semi-recessed mounting

Clip in push fit components ensure reduced time on available in 23v and 12v with choice of controls.

EXCELLENT PERFORMANCE site.

Suitable for high moisture producing rooms such as EASY TO CLEAN

kitchens and utility rooms. ECONOMICAL Simply remove filter and wash in warm soapy

Low running costs. water.

EXTREMELY QUIET

Utilising market leading motors to produce the COMPLETE USER SAFETY WARRANTY

quietest of AC fans. Robust flame retardant construction. 5 year warranty for peace of mind.









Easily removed and cleaned filters. MOUNTING OPTIONS





Side bracket of Side bracket of

mounting frame mounting frame



Circular ducting Flexible ducting









Flat duct

Timber

battens

Mounting frame Mounting frame



Wall fixings through Wall fixings through

mounting frame mounting frame









Simple clip in fan and motor assembly. Semi-recessed mounted - wall. Surface mounted - wall. Flexible duct installation.







Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 113

EXTRAC T

G ENI E NKF 1

TEC HNI C A L I NFO R MATI O N









PERFORMANCE - GENIE NKF1 EXTRACT FANS Casing





Genie NKF1

V

150



ISO 5801

BS848 Part 1 2007

125

High speed

Fan Static Pressure (Pa)









100





Low speed

75

Code descriptions



50 NKF1 - RS

Background

ventilation mode Boost speed | |

25

(X & XR) (X & XR mode) 1 2

1. Genie kitchen fan range

0 2. Control function

0 10 20 30 40 50 60 70



Air volume flow rate (l/s)









GENIE NKF1 FANS - RANGE AND CONTROL FUNCTION

Code Operating

Voltage dBA@3m Control Function

NKF1 230 43/18

off/low/high speed control via integral pullcord.





NKF1-RS 230 43/18

on/off and low/high speed control via remote switch (supplied).



NKF1-STD 230 43 on/off high speed control via light switch link or remote fan

switch (by others).



NKF1-H 230 43/18 off/low/high speed control via integral pullcord with automatic override to

high speed via integral adjustable humidistat.



*NKF1-X 230 43/15 continuous background ventilation at imperceptible noise level with boost

via integral pullcord.



*NKF1-XR 230 43/15 Fan with cover removed.

continuous background ventilation at imperceptible noise level with boost

via remote switch (by others).









114 029 2085 8200

EXTR AC T

G ENI E NKF1

TEC H NIC A L INFO R MATI O N









DIMENSIONS (MM)



Duct mounted



337 138 55



72





92

98 0.D.

225 O.A. 158 CTRS









Optional recessed mounting

flange 15mm wide. 230 CTRS

(Fixing kit code 770984)









SEMI-RECESSED FRAME KIT MOUNTED IN WALL APERTURE.





An aperture of 335mm x 245mm

is required for fan and mounting kit









Plastic collar

fits round

exterior of unit

for semi-recessed

mounting









Fan Unit

Cut bracket flush with

mounting surface of wall





Fan unit spigot fits into back of mounting

frame and into ducting









Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 115

EXTRAC T

G ENI E NKF 1

TEC HNI C A L I NFO R MATI O N









WIRING - GENIE NKF1 FANS



Unit ventilating one room. Single speed Unit ventilating one room. (continuous trickle ventilation with boost

(room switch option NKF1STD only). via remote double pole switch NKF1-XR).

Double pole switch (by others)



3 3



1 1



N N N N

Room light

L L L





Switch

L 2 2

Fuse 2 amp max.







Unit ventilating one room. Two speed Unit ventilating one room. Two speed

(pull cord option NKF1, NKF1H, NKF1-X). (remote switch option NKF1-RS).

N L



3 3



1 1

ON OFF

L2 L3 N

N N

L1

L L Not

L used

Fuse 2 amp max.

HIGH LOW

L3

L2

2 2

L1



Two gang, two way switch (supplied)









116 029 2085 8200

EXTR AC T

G ENI E NKF1

TEC H NIC A L INFO R MATI O N









CO NSULTA NT S SP E CI FIC ATION



GENIE NKFI KITCHEN FAN

The unit shall be manufactured by Nuaire.





The unit shall be surface mountable incorporating a push fit, washable filter with

the area of 34,750mm2 and capable of conversion, if necessary, to semi-recessed

format using optional flange.





Unit noise levels shall not exceed 43dBA@3m.





The unit shall incorporate an injection moulded, forward curved centrifugal

impeller. The impeller shall be directly driven by a motor fitted with seated, self

lubricating bearings and thermal overload protection.





The fan/motor assembly and the unit control assembly shall be capable of

replacement as "plug in" modules without disturbing the unit field wiring.





The unit shall be designed for quiet operation to ensure complete occupant

satisfaction. The unit code, mounting type, operating voltage and control

function shall be as shown in the performance table.





The unit shall be supplied with a 5 year warranty.









Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 117

EXTRAC T

SL I MA I R E SINGL E SPEED

TEC HNI C A L I NFO R MATI O N









SL IM A I RE 230 V & 1 2 V SI NGL E SPEED FANS



EXCEPTIONALLY QUIET, HIGH PERFORMANCE EXTRACT FANS FOR

WALL AND CEILING APPLICATIONS.









118 029 2085 8200

EXTR AC T

SL I MA I R E SING L E SP EED

TEC H NIC A L INFO R MATI O N









B E NE F I T S



MEETS REGULATIONS EASY INSTALLATION FIXED BACK DRAUGHT SHUTTERS

Part F Building regulations compliant. Can be surfaced mounted or recessed. Prevents draughts when fan not in operating mode.





ULTRA MODERN DESIGN FLEXIBLE SOLUTIONS 1 YEAR WARRANTY

Provides an unobtrusive installation and occupant Wide range of options to cover toilet, bathroom, For peace of mind.

acceptability. utility and kitchen applications.





IPX4 SPLASHPROOF MAINTENANCE

Can safely be installed in Zones 1 and 2. Clip of cover of access to clean.





QUIET RUNNING FAN INDICATOR LIGHT

For occupant acceptability. Showing the fans operation.









SLIMAIRE 100 & 150 SINGLE SPEED MOUNTING OPTIONS

FANS









The Nuaire slimline range of axial fans

incorporates 12 models complete with

fixed back draft shutters. The fans have been

specifically designed to ventilate small rooms

such as toilets, bathrooms, shower rooms,

utility rooms and kitchens and are ideal for

wall, ceiling or panel installation. The units

extract directly to outside or through a short

length of ducting.

Wall mounting with outside grille. Ceiling mounting with outside roof cap.







Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 119

EXTRAC T

SL I MA I R E SINGL E SPEED

TEC HNI C A L I NFO R MATI O N









PERFORMANCE SLIMLINE 100 & 150 SINGLE SPEED FANS



70







60







50

Slimaire 150

Fan Static Pressure (Pa)









40







30





Slimaire 100

20







10







0

0 10 20 30 40 50 60 70 80 90



Air volume flow rate (l/s)









SLIMLINE 100 & 150 - RANGE & CONTROL FUNCTION

Operating

Code dBA@3m voltage Control function

SLIMAIRE 100/150 40/49 230 Standard version operated by remote switch.

SLIMAIRE 100PC/150PC 40/49 230 Standard version operated by pull cord.

SLIMAIRE 100T/150T 40/49 230 With integral overrun timer - the fan should be operated by a

remote switch which can also serve to switch the room light on

and off. After the light is switched off, the fan will continue to

operate for a minimum of 3 minutes (adjustable to a maximum

of 25 minutes) by turning the trimmer in a clockwise direction.

SLIMAIRE 100HT/150HT 40/49 230 With integral humidistat and overrun timer - the adjustable,

electronic humidistat is pre-set so that the fan will operate

automatically when the moisture content in the room reaches

a pre-set level of relative humidity. The fan will continue to run

until the relative humidity falls below the pre-set level.

This level can be adjusted by turning the trimmer on the fan.

This fan can be operated by a remote switch or light switch

allowing operation of the fan independently of the humidistat.

The overrun timer, which will always make the fan continue to

operate for the pre-set length of time even after it has been

manually switched off, can be adjusted as described above.

SLIMAIRE 100PIR/150PIR 40/49 230 With integral sensor and overrun timer - the fan will start to

operate automatically when it detects the presence of a person.

After the room is vacated, the fan will continue to operate

for a minimum of 3 minutes (adjustable to a maximum of

25 minutes) by turning the trimmer in an anti-clockwise

direction.

SLIMAIRE 100-12 40 12 This version must be installed using the remote transformer

supplied (see current IEE Regulations for guidance).

SLIMAIRE 100T-12 40 12 With integral overrun timer adjusted as above.

This version must be installed using the remote transformer

supplied (see current IEE Regulations for guidance).









120 029 2085 8200

EXTR AC T

SL I MA I R E SING L E SP EED

TEC H NIC A L INFO R MATI O N









DIMENSIONS (MM) - SLIMLINE 100 & 150 SINGLE SPEED FANS





B

D





DIMENSIONS (mm) & WEIGHTS



Weight

Unit A B C D E dia. (Kg)

A E

SLIMAIRE 100 160 160 81 17 97 0.42

SLIMAIRE 150 200 200 119 22 149 1.04









C









WIRING - SLIMLINE 100 & 150 SINGLE SPEED FANS

SLIMAIRE 100/150 with remote switch. SLIMAIRE 100PC/150PC with pullcord. SLIMAIRE 100T/150T

via light switch (or remote switch).



L L 230V L L 230V N N 230V

~

50Hz ~ ~

50Hz

50Hz T L

N N N N

L

Double Pole Isolator Double Pole Isolator

Triple Pole Isolator









SLIMAIRE 100/150HT PIR with Humidistat SLIMAIRE 100-12, 12V SLIMAIRE 100T-12, 12V via light switch

and Integral sensor. Must be installed with remote transformer. (or remote switch).

Must be installed with remote transformer.

Transformer Transformer

L L 230V

~

50Hz

N N



L N L N L N L N



Double Pole Isolator

12V 230V 12V 230V

230V

L N ~

50Hz

L

N L N



T





Fan unit Double Pole Isolator Fan unit Triple Pole Isolator









Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 121

EXTRAC T

SL I MA I R E TW IN SPEED

TEC HNI C A L I NFO R MATI O N









SL IM A I RE 230 V & 1 2 V T WIN SP EED FANS



EXCEPTIONALLY QUIET, HIGH PERFORMANCE EXTRACT FANS FOR

WALL/WINDOW AND CEILING APPLICATIONS.









122 029 2085 8200

EXTR AC T

SL I MA I R E TWIN SP EED

TEC H NIC A L INFO R MATI O N









B E NE F I T S



MEETS REGULATIONS ENERGY EFFICIENT MODERN DESIGN CONTINUOUS RUNNING

Part F Building regulations compliant. Low running costs. For guaranteed ventilation.





IPX4 SPLASHPROOF BOOST FACILITY MAINTENANCE

Can safely be installed in Zones 1 and 2. For additional airflow via pull cord. Clip of cover of access to clean.





QUIET RUNNING FLEXIBLE SOLUTIONS 1 YEAR WARRANTY

For occupant acceptability. Can be surfaced mounted, wall panel window or For peace of mind.

recessed. (Window kits available - WINKIT100X -

WINKIT150X).









MOUNTING OPTIONS

The Nuaire Slimaire range of SELV and 2 speed axial fans incorporates 3 models. They are ideal

for ventilating small rooms such as toilets, bathrooms, cloakrooms and kitchens etc and can be

installed on wall, ceiling, panel or window.









Window mounting with outside grille. Wall mounting with outside grille. Ceiling mounting with outside roof cap.







Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 123

EXTRAC T

SL I MA I R E TW IN SPEED

TEC HNI C A L I NFO R MATI O N









WIRING - SSLIMLINE 100X & 150X TWIN SPEED FANS PERFORMANCE SLIMAIRE 100X & 150X AXIAL FANS

L L 230V L L 230V

SLIMAIRE 100XPC/150XPC with integral cord. ~

50Hz 70

~

50Hz

N N N N

L L 230V N 230V

~

50Hz

N

60 ~

50Hz

Double Pole Isolator N T Double Pole Isolator

N L

Slimaire 150X

L 50

T









Fan Static Pressure (Pa)

N Double Pole Isolator N 230V L Triple Pole Isolator L 230V

~

50Hz

40 ~

50Hz

SLIMAIRE 100XPC/150XPC

T L

N N

L 230V N 230V 30

~

50Hz

N L

~

50Hz

N T L Slimaire 100X

Triple Pole Isolator 20

Double Pole Isolator

L

10

e Isolator Triple Pole Isolator



SLIMAIRE 100XPC-12, 12V with integral cord. 0

0 10 20 30 40 50 60 70 80 90 100

Transformer Transformer

L 230V L L 230V

~

50Hz

~

50Hz

Air volume flow rate (l/s)

N N N



SLIMAIRE 100X & 150X- RANGE & CONTROL FUNCTION

ator L Double Pole Isolator

N L N L N L N

Operating

Code dBA@3m voltage Control function

12V 230V 12V 230V

SLIMAIRE 100XPC 39 230 Continuous low duty with boost

N 230V L L 230V facility operated by pull cord

~ ~ 230V 230V or remote switch.

L

50Hz L

N

50Hz N ~

50Hz

L ~

50Hz

N SLIMAIRE 100XPC-12 39 12 Continuous low duty with boost

N L N N facility operated by pull cord

T L or remote switch, 12V SELV.

This version must be installed

or Double Pole Isolator using the remote transformer

Fan unit Double Pole Isolator Fan unit Triple Pole Isolator supplied (see current

IEE Regulations for guidance).

SLIMAIRE 100XPC-12, 12V with remote switch. SLIMAIRE 150XPC 49 230 Continuous low duty with boost

(Pull-cord switch must be OFF before removing cord). facility operated by pull cord

or remote switch.

er Transformer

SLIMAIRE 150XPC-12 49 12 Continuous low duty with boost

facility operated by pull cord

or remote switch, 12V SELV.

This version must be installed

using the remote transformer

L N L N supplied (see current

IEE Regulations for guidance).



12V 230V

DIMENSIONS (MM) SLIMAIRE 100X & 150X

230V 230V

N ~

50Hz

L ~

50Hz

B

D

L N N

T L





Isolator Fan unit Triple Pole Isolator

A E









C



DIMENSIONS (mm) & WEIGHTS



Weight

Unit A B C D E dia. (Kg)

SLIMAIRE 100 155 155 92 35 97 0.5

SLIMAIRE 150 209 209 137 52 149 1.2









124 029 2085 8200

EXTR AC T

SL I MA I R E

TEC H NIC A L INFO R MATI O N









CO NSULTA NT S SP E CI FIC ATION



SLIMAIRE 100 & 150 SINGLE SPEED FANS SLIMAIRE 100X & 150X TWIN SPEED FANS

Supplied by Nuaire Ltd the fan is to be suitable for installation either into a Supplied by Nuaire, this fan can either be for installation in a wall, panel, ceiling

ceiling, wall or panel (with the appropriate accessories) There should be a neon or window (with optional kit). The fan should have three speeds, allowing a

on the front of the fan to indicate when it is operating. The fan casing should be choice of one of the two lower speeds for quiet, continuous operation at

made of shockproof, high quality technopolymer, contain double insulated installation. The user should be able to boost the fan to its maximum speed as

motors of shaded poly type mounted on self-lubricating, sealed ball bearings for necessary. The fan should be made of shockproof high quality polymer and have

long life, and be protected with a thermal cut-out.. The fan should be double a maintenance free, self lubricating sleeve bearing motor for long life and

insulated and be suitable for installation into Zones I and II. The fan is to be CE incorporates thermal cut-out.. The fan should be double insulated, splashproof

marked and comply with current EC Low Voltage Directive EMC89/336 and with and CE marked. The fan should comply with Kitchen and Bathroom

BSEN60529. The fan should finally comply with Building Regulations requirements of System 3, Part F1 of the Building Regulations. It should be

requirements for installation into a utility room. capable of operation up to 9 l/sec, at 4 Pa, 2.6 watts at low speed 1, and at 12

l/sec, 14 Pa and 4.8 watts at low speed 2. Finally the fan should comply with EN

60335-2-80, EC Low Voltage Directive LVD 2006/95/CE and EC Directive

EMC2004/108 and be CE marked.









Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 125

EXTRAC T

C O O K ERH O O D

TEC HNI C A L I NFO R MATI O N









COO KE RHO O D E X T RACT FA NS



HIGH PERFORMANCE, STAINLESS STEEL COOKERHOOD.









126 029 2085 8200

EXTR AC T

C O O KER H O O D

TEC H NIC A L INFO R MATI O N









B E NE F I T S



HIGH PERFORMANCE Pressure Drop 07 - COOKERHOOD SS with lights on

424m3/hr extraction capacity through tangential 110

V

motor. 100



90 ISO 5801

EASE OF USE BS848 Part 1 2007

80

Simple push button control to generate speed and Static Pressure (Pa) Speed 3

lighting. 70



60

EASY CLEAN

50

Stainless steel 600mm cookerhood and integral

grease filters. 40

Speed 2

30

OPTIONAL EXTRA’S

20

2 x S1 carbon filters for air recirculation. Speed 1

10



2 YEAR WARRANTY 0

0 20 40 60 80 100 120

Air volume flow rate (l/s)









SPECIFICATIONS

Casing shall be manufactured from easy to clean the manufacturers instruction and maintenance

stainless steel. manual (available from www.nuairegroup.com).

The unit is fitted with two, washable metallic grease Note: the cooker hood will need to be sited

filters for quick and easy maintenance. a minimum of 650mm above the hob.

The hood must be fitted in accordance with









DIMENSIONS (MM)

221mm

170mm

Min 700/Max 1080









500mm

300mm









600mm



40mm



Code description COOKERHOODC-SS Metallic grease filters.





Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 127

EXTRAC T

AC O USTIC VENTIL ATO R

TEC HNI C A L I NFO R MATI O N









Acoustically treated ventilator

minimises noise polution

when background ventilation

is required.



The provision of fresh air for rapid ventilation to all apartments is to be The unit dimensions shall be 450mm wide x 200mm high x 200mm

available without any inconvenience that may be caused by noise deep (min), the depth of the unit shall be telescopic to suit different wall

pollution from the road immediately adjacent to the development. thicknesses; this facility shall not affect the acoustic properties or the air

To this end any apartments situated on the main road are to be provided flow characteristics of the acoustic ventilator.

with an acoustically treated ventilator. These are to be situated in the

The acoustic media used within the unit shall be flame retardant

external wall of any room overlooking the road.

material, Class 0 rated.

N.B. ALL rooms in corner/end apartments where one or more rooms

Unit shall be all as per model reference ACC-400 as manufactured by

overlook the road are to have the acoustic ventilators provided,

Nuaire Ltd.

regardless of that particular room’s proximity to the road.

The unit shall have a 5 year warranty.

Features:

• Manual operation for total flexibility Acoustic Performance –

• Airflow 38l/s @ 50Pa when fully open (Summary – for full data see SRL test report C/04/5L/3108/1

method BS EN ISO 717-1:1997).

• Prevents ingress of wind, rain etc with externally fitted baffle

Vent in closed position:- Rw (C;Ctr) 54

• Aluzinc finish can be painted to allow blending into any

environment Vent in open position:- Rw (C;Ctr) 46



• Telescopic design allows for differing wall thicknesses For comparison, 220mm cavity wall without penetration:-

Rw (C;Ctr) 58

• Class 0 rated flame retardant acoustic material

• SRL test report available

700

• 3 year warranty 650

600

The acoustic ventilator shall be a manually operated device used at the

550

discretion of the apartment’s occupier and when in use shall allow fresh 500

Static Pressure (Pa)









air to pass into the room in question. The fresh air flow will be a 450

combination of natural infiltration and fan assisted via the apartment’s 400

ventilation system. The unit’s air flow characteristic shall be 38l/s @50Pa 350

when the adjustable regulating plate is fully open. When the acoustic 300

ventilator is in use any externally generated noise from the adjacent road 250

shall be kept to acceptable levels and shall be equivalent to that of the 200

particular unit specified elsewhere in this document. 150

100

The acoustic ventilator shall have a baffle plate mounted externally and 50

an adjustable regulating plate on the internal face both suitable for paint 0

finishing. The external baffle shall act as a weather shield stopping the 0 10 20 30 40 50 60 70

ingress of wind, rain, etc. and shall be manufactured from aluminium Air brick set-up resistance

alloy. The adjustable regulating plate shall be of a blank appearance so as

to appear neutral to the wall in which it is situated. The adjustable

regulating plate will be hinged for operation; the hinge mechanism will

be graduated to facilitate the adjustment.

The unit casing shall be manufactured from Aluzinc corrosion protected

steel and shall be of a minimum 1.5mm thickness.







128 029 2085 8200



Related docs
Other docs by dffhrtcv3
Chromosomal Miss-Segregation and DNA Damage
Views: 19  |  Downloads: 0
Christmas
Views: 19  |  Downloads: 0
Christmas Party Counting
Views: 18  |  Downloads: 0
Christmas dishes
Views: 17  |  Downloads: 0
CHRISTIAS FOR BIBLICAL ISRAEL or CFBI
Views: 19  |  Downloads: 0
Christian Ethics Living a Responsible Life
Views: 19  |  Downloads: 0
Christian Duty - Seymour Church of Christ
Views: 19  |  Downloads: 0
Chp 9 Power Point 08-09
Views: 18  |  Downloads: 0
Choose Your Own Adventure 2
Views: 19  |  Downloads: 0
By registering with docstoc.com you agree to our
privacy policy

You are almost ready to download!

You are almost ready to download!