E X T RACT 83
FAN TYPE FAN LOCATION MAX PAGE
PERFORMANCE
MEVDC INLINE DUCT 98l/s 84
MEVAC INLINE DUCT 95l/s 88
GENIE DCE WALL/WINDOW/CEILING 31l/s 94
GENIE DC WALL/WINDOW/CEILING 31l/s 100
GENIE WALL/WINDOW/INLINE 25l/s 106
GENIE NKF1 WALL 70l/s 112
SLIMAIRE SINGLE SPEED WALL/CEILING 82l/s 118
SLIMAIRE TWIN SPEED WALL/WINDOW/CEILING 82l/s 122
COOKERHOOD WALL 117l/s 126
ACOUSTIC VENTILATION EXTERNAL WALL 128
nuaire.co.uk 83
EXTRAC T
MEV DC
TEC HNI C A L I NFO R MATI O N
M E VD C M ULT I P O I NT E X TRACT
A QUIET, ENERGY EFFICIENT, LOW DEPTH CENTRAL EXTRACT SYSTEM.
SAP Q RECOGNISED.
84 029 2085 8200
EXTR AC T
MEV DC
TEC H NIC A L INFO R MATI O N
B E NE F I T S
MEETS BUILDING REGULATIONS QUICK INSTALLATION ADDED STRENGTH
SAP Appendix Q recognised. Part F&L - England & Unique locating bracket enables the units to be ABS moulded case & lid provides longer life and a
Wales. Scottish technical handbook (BRE398 fixed in any plane, quickly and efficiently at either more robust unit.
referenced). Technical booklet K1998. 1st fix or 2nd fix stage.
ADDITIONAL OPTIONS
LOW DEPTH, HIGH PERFORMANCE REMOTE FAILURE INDICATOR Run on timer, humidistat, G2 filter together with a
Only 190mm deep & up to 98l/s. Visual and audible failure indicator. range of round and rectangular spigot and damper
Code: ES-AVI / ES-OPUS-RFI. kits.
MOST EFFICIENT
Latest DC motors provide high performance with EASY COMMISSIONING WARRANTY
low SFP within their respective class. Ecosmart ‘dial a duty’ option allows for infinitely 5 year warranty for peace of mind.
variable speed selection allowing for exact design
QUIETEST SOLUTION selection. Basic, cost effective model also available.
Advanced motor and impeller technology with Code - MEVDC2. Contact Nuaire’s technical
acoustic lined lid (fully lined case option available) EASY MAINTENANCE team 02920 858200 for further information.
provide one of the quietest options. Easy to access for optional filters for quick and easy
maintenance.
FLEXIBLE SOLUTION
Unit can be fixed horizontally or vertically.
Dial a duty. (Optional). Simple fixing bracket.
Acoustically lined lid. (optional case lining available). Easy access to filter. (Optional).
Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 85
EXTRAC T
MEV DC
TEC HNI C A L I NFO R MATI O N
PERFORMANCE - MEVDC Casing
MEVDC Multi Point Extract
Tested in duct
600 V
ISO 5801 2007
500
Fan Static Pressure (Pa)
400
Code description (example)
300 MEVDC - ES G2 L H D4
4
| | | | | |
200 1 2 3 4 5 6
2 3
1
100 1. DC motor type
2. Ecosmart ‘Dial a duty’ (optional)
3. G2 filter (optional)
0
0 20 40 60 80 100 120 4. Lined case (optional)
Air volume flow rate (l/s)
5. Humidistat (optional)
6. D4 damper kit (optional)
Note: Above are variable speeds, not set speeds.
MEVDC
E L E CT R I C AL & S OU N D
Curve Power Consumption FLC Open inlet sound power levels dB re 1pW Breakout Noise level
Watts Amps 63 125 250 500 1K 2K 4K 8K dBA@3m
1 11 0.14 39 39 44 36 31 22 21 18 19
2 21 0.19 40 42 46 41 37 28 24 18 27
3 35 0.25 43 43 50 46 41 31 28 27 31
4 52 0.37 45 44 54 52 44 35 31 27 34
Note: above sound level figures are for fully lined unit. Unit has a soft start feature as standard therefore the starting current is the same as the full load current.
Step curves are for information purposes only and are not individual units. The electrical and sound information in the table is nominal.
Note: dBA figures are calculated based on hemi-spherical propagation.
S A P A PPE N DIX Q T E S T R E S U LT S OPTIONAL EXTRAS
Application Specific fan power Energy Saving Trust Optional extras: Code MEVDC
(W/l/s) Best Practice Compliant Ecosmart Dial ‘a’ duty ES G
MEV-DC MEVDC-ES Run on timer R G
Kitchen + 1 wetroom 0.35 0.34 Yes G2 filter G2 G
Kitchen + 2 wetrooms 0.30 0.31 Yes *G4 filter (for MEV-SVS application) G4 G
Kitchen + 3 wetrooms 0.31 0.33 Yes Acoustic lining (full case) L G
Kitchen + 4 wetrooms 0.33 N/A Yes Humidistat H G
Kitchen + 5 wetrooms 0.38 N/A Yes *Please refer to page 2.10
Spigot/damper kits (Choose from S1-D4)
Kit 1 - 4 x 100 circular & 2 x 125 circular spigots S1 G
Kit 2 - 6 x rectangular spigots 110 x 54mm S2 G
Kit 3 - 6 x rectangular dampers 110 x 54mm D3 G
Kit 4 - 4 x 100 & 2 x 125 circular damper D4 G
Note – unless spigot kit is specified, a default kit comprising of 4 x 100 and
2 x 125mm spigots will be included.
86 029 2085 8200
EXTR AC T
MEV DC
TEC H NIC A L INFO R MATI O N
DIMENSIONS (MM) - MEVDC
Mounting bracket
Single screw unit fixing
10
SIDE VIEW END VIEW
125 ø
190
Cable entry 20mm Removable panel
containing filter access
VIEW WITH ACCESS PANEL REMOVED MOUNTING BRACKET TOP VIEW
50
Bracket fixing 4 holes 7.5 dia.
140
350
Filter
170
3
490
WIRING - MEVDC
Unit serving Bathroom only Unit Serving Kitchen and two Bathrooms
Fan Fan
Unit Unit
MAINS MAINS
230V N N 230V N N
50Hz 50Hz
L L L L
Fuse 2A Fuse 2A Room
Optional SL lights SL
lamp 3 Pole 3 Pole
isolator Light
switches isolator
Remote/light switch (Double
Pole)
Unit Serving Kitchen and Bathroom Kitchen switch
Fan
Unit
MAINS
230V N N
50Hz
L L
Fuse 2A Room
light SL
Light 3 Pole
switch isolator
(Double
Pole)
Kitchen switch
Download specification from www.nuaire.co.uk/specifications
F
nuaire.co.uk 87
EXTRAC T
MEVAC
TEC HNI C A L I NFO R MATI O N
M E VAC M ULT I P O I NT E X T RACT
QUIET, MULTI-CONNECTION, LOW DEPTH CENTRAL EXTRACT SYSTEM.
88 029 2085 8200
EXTR AC T
MEVAC
TEC H NIC A L INFO R MATI O N
B E NE F I T S
MEETS BUILDING REGULATIONS QUICK INSTALLATION ADDED STRENGTH
Part F - England & Wales. Scottish technical Unique locating bracket enables the units to be ABS moulded case & lid provides longer life and a
handbook (BRE398 referenced). Technical booklet fixed in any plane, quickly and efficiently at either more robust unit.
K1998. 1st fix or 2nd fix stage.
ADDITIONAL OPTIONS
LOW DEPTH, HIGH PERFORMANCE EASY MAINTENANCE Run on timer, humidistat, G2 filter together with a
Only 190mm deep and up to 95l/s (AC). Easy to access for optional filters for quick and easy range of round and rectangular spigot and damper
maintenance. kits.
QUIETEST SOLUTION
Advanced motor and impeller technology with FLEXIBLE SOLUTION WARRANTY
acoustic lined lid (fully lined case option available) Unit can be fixed horizontally or vertically. 3 year warranty for peace of mind.
provide one of the quietest options.
Easy access to filter. (Optional).
Acoustically lined lid. Simple fixing bracket.
Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 89
EXTRAC T
MEVAC
TEC HNI C A L I NFO R MATI O N
PERFORMANCE - MEVAC Casing
MEVAC Multi Point Extract
400
Tested in duct
V
ISO 5801 2007
350
300
Code description (example)
250
Fan Static Pressure (Pa)
MEVAC - 6S R G2 S2
200 | | | | |
1 2 3 4 5
150
1. AC motor type
2. Adjustable speed (optional)
100
3 4 3. Run on timer (optional)
4. G2 Filter (optional)
2
50 5. S2 Spigot kit (optional)
1
0
0 10 20 30 40 50 60 70 80 90 100
Air volume flow rate (l/s)
Note: Above are variable speeds, not set speeds.
MEVAC
E L E CT R I C AL & S OU N D
Curve Power Consumption FLC Open inlet sound power levels dB re 1pW Breakout Noise level
Watts Amps 63 125 250 500 1K 2K 4K 8K dBA@3m
1 14 0.15 43 37 42 35 32 23 22 26 20
2 26 0.2 46 43 52 45 45 37 27 26 32
3 37 0.22 41 40 57 51 51 43 35 28 37
4 59 0.25 45 45 66 58 59 51 45 37 45
Note: above sound level figures are for lid lined unit only.Unit has a soft start feature as standard therefore the starting current is the same as the full load current.
Please note step curves are for information purposes only and are not individual units. (The units has 4 speeds and uses, 2 from 4 speeds (default speeds are 1 and 3). Optional 6S model).
Note: dBA figures are calculated based on hemi-spherical propagation. The electrical and sound information in the above table is nominal.
PRODU CT FE AT U R E S OPTIONAL EXTRAS
Code MEVAC Optional extras: Code MEVAC
Features: Adjustable speed option 6S G
AC motor G Run on timer R G
2 speed (fixed) G G2 filter G2 G
Mounting brackets G *G4 filter (for MEV-SVS application) G4 G
Acoustic lined lid G Acoustic lining (full case) L G
Note – unless spigot kit is specified, a default kit comprising of 4x100 & 2x125mm *Please refer to page 2.10
spigots will be included.
Spigot/damper kits (Choose from S1-D4)
Kit 1 - 4 x 100 circular & 2 x 125 circular spigots S1 G
Kit 2 - 6 x rectangular spigots 110 x 54mm S2 G
Kit 3 -6 x rectangular dampers 110 x 54mm D3 G
Kit 4 - 4 x 100 & 2 x 125 circular damper D4 G
Note – unless spigot kit is specified, a default kit comprising of 4 x 100 and
2 x 125mm spigots will be included.
90 029 2085 8200
EXTR AC T
MEVAC
TEC H NIC A L INFO R MATI O N
DIMENSIONS (MM) - MEVAC
Mounting bracket
Single screw unit fixing
10
SIDE VIEW END VIEW
125 ø
190
Cable entry 20mm Removable panel
containing filter access
VIEW WITH ACCESS PANEL REMOVED MOUNTING BRACKET TOP VIEW
50
Bracket fixing 4 holes 7.5 dia.
140
350
Filter
170
K
490
WIRING - MEVAC
Unit Serving Kitchen and Bathroom Unit Serving Kitchen and Utility and Bathroom
230V 230V
1ph 1ph
N N N N
50Hz 50Hz
supply L L supply L L
Fuse 2A max. Room Fuse 2A max. Room
light SL light SL
Light switch Light switch
bathroom bathroom
(double pole) (double pole)
Kitchen switch
Kitchen switch Utility switch
Unit Serving Kitchen and two Bathrooms
230V
1ph N
50Hz N
supply L L
Fuse 2A max.
F Room
lights SL
Light switch
bathroom/wc
(double pole)
Kitchen switch
Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 91
EXTRAC T
MEV DC
TEC HNI C A L I NFO R MATI O N
CONSULTA NT S SP E CI F I C ATION
MEVDC UNIT
The unit shall be designed specifically for incorporation within a system designed The unit shall incorporate electrical connections to allow for the unit’s "boost"
to comply with the requirements of Part F Building Regs. Ducting and grilles airflow to be triggered by any one or combination of the following:
forming part of the system are specified elsewhere.
1. A switched live signal, 230V.
The unit shall be manufactured by a BSI Registered Firm with ISO 9000 2. A remote speed control.
certification. The unit’s casing shall be of ABS, Moulded plastic with a part lined
lid of high density class "O" flame retardant acoustic insulation designed to limit When the unit "boost" has been triggered by the switched live signal the unit
noise breakout from the unit to a maximum of 34dBA (DC model) - hemi- shall incorporate an adjustable "run on" facility (optional).
spherical radiation.
The MEVDC unit shall be offered with a 5 year warranty.
The unit shall incorporate a low profile single point mounting bracket for
horizontal or vertical mounting of the unit. When installed the unit shall not MEVDC-ES (optional Ecosmart control).
project any more than 190mm from the surface onto which it installed.
The unit shall be provided with a casing mounted, easily accessible, factory
Air discharge from the unit shall be via a tapered spigot for easy connection to connected, user control panel providing the following airflow control settings:
ducting. The unit shall be capable of multiple air inlets formatting. The unit
casing shall have the facility to allow the connection, via tapered air inlet spigots (a) Setting of the unit’s "background" design airflow rate via a calibrated dial
supplied with the unit of up to 4 No. 100 mm diameter and 2 No. 125mm labelled between 10 and 90 litres/second.
diameter air inlet ducts. (b) Setting of the units "boost" design airflow rate via a calibrated dial labelled
between 10 and 90 litres/second.
The unit shall incorporate a quick release, access panel for easy maintenance if (c) Setting of the "boost" airflow run on time via a calibrated dial labelled
filter is fitted. Replacement filter codes are G2 = 776717 and G4 = 776718. between 0 and 60 minutes.
The unit shall be constructed with one removable panel allowing full The unit shall incorporate a factory fitted, automatic constant volume control
maintenance access. The unit shall incorporate a fully speed adjustable (note: facility to ensure as far as is practical that the pre-set "background" and "boost"
stepped speed control shall not be acceptable) low energy, high efficiency DC design airflows are maintained, within the capabilities of the unit’s performance
fan/motor assembly with sealed for life bearings designed to operate levels.
continuously at a pre-set "background" design airflow rate with the ability to
increase to a pre-set "boost" design airflow rate as and when required. It shall The control panel shall also incorporate a fan status indicator light and the
operate up to an ambient temperature of 40°C and be fitted with a one shot facility to check and provide visual indication that the installed unit is actually
thermal overload protective device. achieving the duties set at the dial.
The impeller should be a centrifugal backward curved type, dynamically
balanced mounted directly onto the motor.
92 029 2085 8200
EXTR AC T
MEVAC
TEC H NIC A L INFO R MATI O N
CO NSULTA NT S SP E CI FIC ATION
MEVAC UNIT
The unit shall be designed specifically for incorporation within a system designed
to comply with the requirements of Part F Building Regs. Ducting and grilles
forming part of the system are specified elsewhere.
The unit shall be manufactured by a BSI Registered Firm with ISO 9000
certification. The unit’s casing shall be of ABS, Moulded plastic with a part lined
lid of high density class "O" flame retardant acoustic insulation designed to limit
noise breakout from the unit to a maximum of 45dBA (AC model) - hemi-
spherical radiation.
The unit shall incorporate a low profile single point mounting bracket for
horizontal or vertical mounting of the unit. When installed the unit shall not
project any more than 190mm from the surface onto which it installed.
Air discharge from the unit shall be via a 125mm diameter tapered spigot for
easy connection to ducting. The unit shall be capable of multiple air inlets
formatting. The unit casing shall have the facility to allow the connection, via
tapered air inlet spigots supplied with the unit, of up to 4 No.100 mm diameter
and 2 No. 125mm diameter air inlet ducts.
The unit shall incorporate a quick release, access panel for easy maintenance if
filter is fitted.
The AC version should be a capacitor run external rotor motor capable of 2 fixed
speeds. 230V 50Hz AC with ball race bearings, greased for life. It shall operate up
to an ambient temperature of 40°C and be fitted with a one shot thermal
overload protective device.
The impeller should be a centrifugal backward curved type, dynamically
balanced mounted directly onto the motor.
The unit shall incorporate electrical connections to allow for the unit’s "boost"
airflow to be triggered by a switched live signal.
The MEVAC unit shall be offered with a 3 year warranty.
Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 93
EXTRAC T
G ENI E DC E
TEC HNI C A L I NFO R MATI O N
G E NI E - D CE D E CE NT RA L I SED M ECHANIC AL EXTRACT FANS (dMEV)
MEET YOUR CODE FOR SUSTAINABLE HOMES REQUIREMENT WITH
DECENTRALISED MEV. SAP APPENDIX Q RECOGNISED.
94 029 2085 8200
EXTR AC T
G ENI E DC E
TEC H NIC A L INFO R MATI O N
B E NE F I T S
MEETS REGULATIONS EASY COMMISSIONING IDEAL FOR HIGH RISE BUILDINGS
SAP Appendix Q recognised. Commission in seconds with a dial ‘a’ duty feature. Fan is capable of maintaining the set flow rate to
New Part F-ventilation in buildings (System 3) within 5% even under wind load conditions.
continuous mechanical extract. POWERFUL YET COMPACT
New Part L - conservation of fuel and power. Improved performance over the AC fan, up WARRANTY
BRE digest 398. to 30l/s for the bathroom fan. 5 year warranty with extended warranty options.
Meets minimum fan power in ‘Domestic Building
Services Compliance Guide’ (2010 edition). COMPLETE USER SAFETY
Flame retardant construction and Genie 12V model
ECONOMICAL is IPX4 rated.
Daily running cost is 80% lower than AC fans due
to low wattage motor technology. WIDE RANGE OF OPTIONS
Range is ideal for all applications including
SILENT RUNNING bathroom, en-suite, kitchen and utility areas.
Utilising market leading motor and impellor Available in 230V or 12V with a choice of controls
technology to produce the quietest of fans with a for boost speed.
maximum of 35dBA@3m.
FLEXIBLE SOLUTION
QUICK AND EASY INSTALLATION Mount anywhere. Install in the wall, ceiling or
AND MAINTENANCE window. Low profile recess option is available.
Clip in push fit components ensure reduced time on (Window kit code – WINKIT).
site.
EASY TO CLEAN
Simply remove filter and wash in warm soapy
water.
CLIP IN PUSH FIT COMPONENTS MOUNTING OPTIONS
Easily removed fan/motor assembly. Removable electronic control module.
Semi-recessed mounted - wall.
Plug-in wiring connector.
Surface mounted - wall.
Semi-recessed mounted - ceiling.
Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 95
EXTRAC T
G ENI E DC E
TEC HNI C A L I NFO R MATI O N
PERFORMANCE GENIE-DCE EXTRACT FANS Casing
Genie-DCE Extract Fans
120
V
100 ISO 5801
BS848 Part 1 2007
Full speed - Boost
80
Fan Static Pressure (Pa)
60
Note: see window kit for window version.
Kitchen (13l/s)
40 Code descriptions
GENIE-DCE-H12
20
Bathroom/ | | | |
wet room (8l/s)
1 2 3 4
0 1. Genie range
0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 20.0 22.0 24.0 26.0 28.0 30.0 32.0 2. Low wattage DC motor
3. Control function
Air volume flow rate (l/s) 4. Voltage
GENIE-DCE FANS RANGE AND CONTROL FUNCTION
Sound levels
Unit Trickle-Bathroom Trickle-Kitchen Full speed/Boost Mounting Operating
Code dBA@3m dBA@3m dBA@3m Type Voltage Control function
GENIE-DCE 18 20 34.5 surface 230 continuous ventilation at imperceptible noise level with boost
duty activated via light switch or remote fan switch (by others)
or integral pullcord.
With adjustable run-on timer (1–60 mins).
GENIE-DCE-12 18 20 34.5 surface 12 12V continuous ventilation at imperceptible noise level with
boost duty activated via light switch or remote fan switch
(by others) or integral pullcord. With adjustable run-on timer
(1–60 mins). Purpose made transformer.
*GENIE-DCE-H 18 20 34.5 surface 230 continuous ventilation with boost via integral humidistat,
pull cord or light switch (by others).
With adjustable run-on timer (1–60 mins).
*GENIE-DCE-H12 18 20 34.5 surface 12 12V continuous ventilation with boost via integral humidistat,
pull cord or light switch (by others).
With adjustable run-on timer (1–60 mins).
Purpose made transformer.
*Recommended for optimum humidity and odour control. Note: Code for Genie Window kit is WinKit.
SAP APPENDIX Q TEST RESULTS *SYSTEMS WITH RIGID DUCTING ONLY
Fan Specific Flow Flow rate % Reduction
Unit speed fan power rate - wind of total
configuration Location setting (W/l/s) (l/s) condition (l/s) flow rate (%)
In room Kitchen Kitchen 0.28 14.4 13.8 4
Wet room Bathroom 0.28 9.1 8.7 4
Through wall Kitchen Kitchen 0.23 15.1 14.8 2
Wet room Bathroom 0.23 8.2 8.2 0
96 029 2085 8200
EXTR AC T
G ENI E DC E
TEC H NIC A L INFO R MATI O N
WINDOW MOUNTING OPTION Top three shutter blades temporarily
removed during installation. Window 4mm to 32mm thick.
The window mounting kit is designed for mounting the unit into
Cut 125mm hole for fan.
windows 4mm to 32mm thick using a 125mm dia hole.
Electrical cable passed
For further information please refer to Installation document 671504. through the inner gasket
and fed into case.
Unit case.
Outer shutter
frame.
Outer gasket, spigot moulding
locates in window aperture.
Inner gasket, spigot moulding
locates in window aperture.
Approximately 150mm of
cable for final wiring.
DIMENSIONS GENIE-DCE FAN UNIT (MM)
73 126
18 71
80
200 98 OD
173
208
18
Recessed mounting Overall width when
flange provided 55 Recessed only
WIRING - 230V AND 12V FANS
230V units via Remote Switch 3 12V units via Remote Switch 3
1 1
230V 12V
GENIE-DCE N GENIE-DCE-12 N N N
GENIE-DCE-H GENIE-DCE-H12
L L L L
N E N E
L 2 2
L SL 2
Fuse 2 amp Fuse 2 amp Fan
Transformer
The switched Live signal to terminal 2 must be at 230V to enable the fan
and at 0V to stop the fan after the adjustable timed overrun period.
Induced voltages in the switched live field wiring can keep the unit running.
230V units via Pullcord 3 12V units via Pullcord 3
1 230V 12V 1
GENIE-DCE N GENIE-DCE-12 N N N N
N Fuse 2 amp
GENIE-DCE-H GENIE-DCE-H12
L L L L L L
Fuse 2 amp E E
As wiring for remote switch
2 excluding switch. 2
Fan
Transformer
Warning: For EMC compliance the 12V cable should not be fitted within 50mm of 230V or other cables or on the same tray/ trunking
if made of metal. The earth connection in the transformer enclosure should not be used. No earth connection should be made to the
12V fan unit.
Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 97
EXTRAC T
G ENI E DC E
TEC HNI C A L I NFO R MATI O N
POWER CONSUMPTION
230V 12V
Unit input power (watts) 12 16
Full load current (amps) .14 .085
Starting Current (amps) .14 .085
12V TRANSFORMER DETAILS
Transformer Installation notes for wiring sizes Transformer to fan (12V units only)
It is important to note that the size of wire used between the transformer Cable run (max. 10 metres) Cable size
and the fan unit can have an adverse effect on the units performance if the Up to 2m 0.75mm sq.
following table is not adherred to. Up to 4m 1.00mm sq.
Mains Supply: (230V) 0.5mm sq. Up to 6m 1.50mm sq.
Up to 10m 2.50mm sq.
12V TRANSFORMER DIMENSIONS (MM)
Side view End view
147mm 85mm
64mm
32mm
Plan view
Cover fixings
85mm
View inside with cover removed
12V OUTPUT N
230V SUPPLY
SWL N L
FAN
L
2
12V supply Mains supply
to fan 230V 1ph 50Hz
98 029 2085 8200
EXTR AC T
G ENI E DC E
TEC H NIC A L INFO R MATI O N
CO NSULTA NT S SP E CI FIC ATION
GENIE-DCE KITCHEN AND WET ROOM FAN
The unit shall be manufactured by Nuaire. Fan status indication to be visible on front of unit, with flashing LED to show fan
failure.
Unit shall be SAP Appendix Q recognised.
Plastic casing to be manufactured from flame retardant materials.
Under wind load conditions the unit will be capable of maintaining it’s set The unit shall be designed for quietest operation to ensure occupant satisfaction.
flowrate to within 5%.
The unit shall incorporate electrical connections to allow for the unit’s “boost”
The unit shall be surface mountable incorporating a push fit, washable filter with airflow to be triggered by either pull-cord or switched live.
an area of 23,750mm2 and capable of conversion, if necessary, to semi-recessed
format using flange supplied or window mounting format using optional fixing kit. The unit shall be supplied with a 5 year warranty.
Unit noise level shall not exceed 20dBA @3m for kitchens and 18dBA for wet
rooms (normal running).
The unit shall incorporate an injection moulded forward curved centrifugal impeller.
The impeller shall be directly driven by a low energy, high efficiency 12V DC
motor, fitted with sealed, self lubricating ball bearings.
Motors shall have locked rotor protection to prevent overheating in the event of
fan failure.
The fan/motor assembly and the unit control assembly shall be capable of
replacement as "plug in" modules without disturbing the field wiring.
Each unit is capable of being set to comply with new edition (2010).
Part F – ventilation building regulations for (System 3) continuous mechanical
extract (MEV) and new edition (2010) Part L - conservation of fuel and power.
Units shall be fitted with a run-on timer facility (1-60 minutes), from switched
live signal only.
Unit can comply with BRE digest 398 under continuous mechanical extract
ventilation.
Meets the minimum fan power requirement of 0.5w/l/s in the in ‘Domestic
Building Services Compliance Guide’ (2010 edition).
Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 99
EXTRAC T
G ENI E DC
TEC HNI C A L I NFO R MATI O N
G E NI E - D C UNI V E RSA L SURFACE MOUNTED EXTRACT FANS
LATEST ENERGY SAVING TECHNOLOGY APPLIED TO
PROVEN GENIE DESIGN.
100 029 2085 8200
EXTR AC T
G ENI E DC
TEC H NIC A L INFO R MATI O N
B E NE F I T S
MEETS REGULATIONS EASY COMMISSIONING FLEXIBLE SOLUTION
New Part F & L under (System 1) Intermittent Fan speed is fully adjustable. Mount anywhere. Install in the wall, ceiling or
extract fans. window. Low profile recess option is available.
Scottish building regs for intermittent bathroom ECONOMICAL (Window kit code – WINKIT).
extract fans. Daily running cost is 80% lower than AC fans due
BRE digest 398 under continuous mechanical to low wattage motor technology. EASY TO CLEAN
extract ventilation. Simply remove filter and wash in warm soapy
Meets minimum fan power requirement in POWERFUL YET COMPACT water.
‘Domestic Building Services Compliance Guide’ Improved performance over the AC fan, up to 30l/s
(2010 edition). for the bathroom fan. IDEAL FOR HIGH RISE BUILDINGS
Fan is capable of maintaining the set flow rate to
SILENT RUNNING COMPLETE USER SAFETY within 5% even under wind load conditions.
Utilising market leading motor and impeller Flame retardant construction and Genie 12V model
technology to produce the quietest of fans. is IPX4 rated. WARRANTY
5 year warranty with extended warranty options.
QUICK AND EASY INSTALLATION AND WIDE RANGE OF OPTIONS
MAINTENANCE Range is ideal for all applications including
Clip in push fit components ensure reduced time on bathroom, en-suite, kitchen and utility areas.
site. Replace your Genie internal components with Available in 230V or 12V with a choice of controls.
latest energy saving technology, low wattage
components.
CLIP IN PUSH FIT COMPONENTS MOUNTING OPTIONS
Easily removed fan/motor assembly. Removable electronic control module.
Semi-recessed mounted - wall.
Plug-in wiring connector.
Surface mounted - wall.
Semi-recessed mounted - ceiling.
Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 101
EXTRAC T
G ENI E DC
TEC HNI C A L I NFO R MATI O N
PERFORMANCE GENIE-DC EXTRACT FANS Casing
Genie-DC Extract Fans
120
V
100 ISO 5801
BS848 Part 1 2007
Full speed - Boost
80
Fan Static Pressure (Pa)
60
Note: see window kit for window version.
40 Minimum speed
Background
Code descriptions
Ventilation
GENIE-DC-H12
20
| | | |
1 2 3 4
0 1. Genie range
0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 20.0 22.0 24.0 26.0 28.0 30.0 32.0 2. Low wattage DC motor
3. Control function
Air volume flow rate (l/s) 4. Voltage
GENIE-DC FANS RANGE AND CONTROL FUNCTION
Unit Min speed Full speed/Boost Mounting Operating
Code dBA@3m Type Voltage Control function
GENIE-DC-S 16.0 34.5 surface 230 on/off control via light switch link or remote fan switch (by others) with
adjustable run-on timer (1–60 mins).
GENIE-DC-S12 16.0 34.5 surface 12 12V on/off control via light switch link or remote fan switch (by others) with
adjustable run-on timer (1–60 mins).
Purpose made transformer.
*GENIE-DC-H 16.0 34.5 surface 230 on/off control via light switch link or remote fan switch (by others)
or via integral pull cord with automatic override by integral adjustable
humidistat.
*GENIE-DC-H12 16.0 34.5 surface 12 12V on/off control via light switch link or remote fan switch (by others)
or via integral pull cord with automatic override by integral adjustable
humidistat. Purpose made transformer.
GENIE-DC-X 16.0 34.5 surface 230 continuous ventilation at imperceptible noise level with boost duty
activated via light switch or remote fan switch (by others) or integral
pullcord. With adjustable run-on timer (1–60 mins).
GENIE-DC-X12 16.0 34.5 surface 12 12V continuous ventilation at imperceptible noise level with boost duty
activated via light switch or remote fan switch (by others) or integral
pullcord. With adjustable run-on timer (1–60 mins). Purpose made transformer.
*GENIE-DC-XH 16.0 34.5 surface 230 universal fan, continuous ventilation with boost via integral humidistat,
pull cord or light switch (by others).
With adjustable run-on timer (1–60 mins).
*GENIE-DC-XH12 16.0 34.5 surface 12 universal fan, 12V continuous ventilation with boost via integral humidistat,
pull cord or light switch (by others). With adjustable run-on timer (1–60 mins).
Purpose made transformer.
*Recommended for optimum humidity and odour control. Note: Code for Genie Window kit is WinKit.
102 029 2085 8200
EXTR AC T
G ENI E DC
TEC H NIC A L INFO R MATI O N
WINDOW MOUNTING OPTION Top three shutter blades temporarily
removed during installation. Window 4mm to 32mm thick.
The window mounting kit is designed for mounting the unit into
Cut 125mm hole for fan.
windows 4mm to 32mm thick using a 125mm dia hole.
Electrical cable passed
For further information please refer to Installation document 671504. through the inner gasket
and fed into case.
Unit case.
Outer shutter
frame.
Outer gasket, spigot moulding
locates in window aperture.
Inner gasket, spigot moulding
locates in window aperture.
Approximately 150mm of
cable for final wiring.
DIMENSIONS GENIE-DC FAN UNIT (MM)
73 126
18 71
80
200 98 OD
173
208
18
Recessed mounting Overall width when
flange provided 55 Recessed only
WIRING - 230V AND 12V FANS
230V units via Remote Switch 3 12V units via Remote Switch 3
1
230V 12V 1
GENIE-DC-S N GENIE-DC-S12
GENIE-DC-H GENIE-DC-X12 N N N
GENIE-DC-X L GENIE-DC-H12 L L L
GENIE-DC-XH N E GENIE-DC-XH12 N E
L 2
L SL 2 2
Fuse 2 amp
Fuse 2 amp Fan
Transformer
The switched Live signal to terminal 2 must be at 230V to enable the fan
and at 0V to stop the fan after the adjustable timed overrun period.
Induced voltages in the switched live field wiring can keep the unit running.
230V units via Pullcord 3 12V units via Pullcord 3
1 230V 12V 1
GENIE-DC-H N GENIE-DC-X12 N N N N
N Fuse 2 amp
GENIE-DC-X GENIE-DC-H12
L L L L L L
GENIE-DC-XH GENIE-DC-XH12
Fuse 2 amp E E
As wiring for remote switch
2 excluding switch. 2
Fan
Transformer
Warning: For EMC compliance the 12V cable should not be fitted within 50mm of 230V or other cables or on the same tray/ trunking
if made of metal. The earth connection in the transformer enclosure should not be used. No earth connection should be made to the
12V fan unit.
Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 103
EXTRAC T
G ENI E DC
TEC HNI C A L I NFO R MATI O N
POWER CONSUMPTION
230V 12V
Unit input power (watts) 12 16
Full load current (amps) .14 .085
Starting Current (amps) .14 .085
12V TRANSFORMER DETAILS
Transformer Installation notes for wiring sizes Transformer to fan (12V units only)
It is important to note that the size of wire used between the transformer Cable run (max. 10 metres) Cable size
and the fan unit can have an adverse effect on the units performance if the Up to 2m 0.75mm sq.
following table is not adherred to. Up to 4m 1.00mm sq.
Mains Supply: (230V) 0.5mm sq. Up to 6m 1.50mm sq.
Up to 10m 2.50mm sq.
12V TRANSFORMER DIMENSIONS (MM)
Side view End view
147mm 85mm
64mm
32mm
Plan view
Cover fixings
85mm
View inside with cover removed
12V OUTPUT N
230V SUPPLY
SWL N L
FAN
L
2
12V supply Mains supply
to fan 230V 1ph 50Hz
104 029 2085 8200
EXTR AC T
G ENI E DC
TEC H NIC A L INFO R MATI O N
CO NSULTA NT S SP E CI FIC ATION
GENIE-DC BATHROOM FAN
The unit shall be manufactured by Nuaire. Fan status indication to be visible on front of unit, with flashing LED
to show fan failure.
The unit shall incorporate, where necessary, a magnetically latched anti back
draft shutter at the fan rear outlet. (except ‘X’ variants). Humidity detection units will vary speed proportionally with humidity level.
The unit shall be surface mountable incorporating a push fit, washable filter with The unit complies with new edition (2010) Part F-ventilation building
an area of 23,750mm2 and capable of conversion, if necessary, to semi-recessed regulations (for System 1) intermittent extract fans and new edition (2010) Part
format using flange supplied or window mounting format using optional fixing kit. L - conservation of fuel and power.
Unit noise level shall not exceed 35dBA @3m. Meets the minimum fan power requirement of 0.5w/l/s in the ‘Domestic
Building Services Compliance Guide’ (2010 edition).
The unit shall incorporate an injection moulded forward curved centrifugal impeller.
Can comply with Scottish building regs for intermittent bathroom extract.
The impeller shall be directly driven by a low energy, high efficiency
12V DC motor, fitted with sealed, self lubricating ball bearings. Can comply with BRE digest 398 under continuous mechanical extract
ventilation (X-variants).
Motors shall have locked rotor protection to prevent overheating in
the event of fan failure. Plastic casing to be manufactured from flame retardant materials.
The unit shall be designed for quietest operation to ensure occupant satisfaction.
The fan/motor assembly and the unit control assembly shall be capable of
replacement as "plug in" modules without disturbing the field wiring. The unit shall incorporate electrical connections to allow for the unit’s “boost”
airflow to be triggered by either the switched live signal
To prevent over ventilation each unit shall be fitted with fully adjustable speed (‘S’ variants) or pull-cord/switched live (X, H, & XH units)
control. For single speed units one adjustable potentiometer is fitted. For
continuously running fans adjustment can be made to both the continuous and The unit shall be supplied with a 5 year warranty.
boost speeds.
Units shall be fitted with a run-on timer facility (1-60 minutes)
(‘S’ and ‘X’ variants).
Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 105
EXTRAC T
G ENI E
TEC HNI C A L I NFO R MATI O N
G E NI E EX T RACT FA NS
LOW MAINTENANCE, EXTRACT FANS.
106 029 2085 8200
EXTR AC T
G ENI E
TEC H NIC A L INFO R MATI O N
B E NE F I T S
MEETS REGULATIONS COMPLETE USER SAFETY EASY TO CLEAN
Complies with Building Regulations. Flame retardant construction and Genie 12V model Simply remove filter and wash in warm soapy
is IPX4 rated. water.
EXTREMELY QUIET
Utilising market leading AC motors to produce the WIDE RANGE OF OPTIONS WARRANTY
quietest of AC fans. Range is ideal for all applications including 5 year warranty for peace of mind.
bathroom, en-suite kitchen and utility areas.
QUICK & EASY INSTALLATION AND Available in 230v or 12v with choice of controls.
MAINTENANCE
Clip in push fit components ensure reduced time on FLEXIBLE SOLUTION
site. Mount anywhere. Install in the wall, ceiling or
window. Low profile recess option is also available
ECONOMICAL (Window kit code – WINKIT).
Low running costs.
Easily removed plug-in control module. MOUNTING OPTIONS
Semi-recessed mounted - wall.
Surface mounted - wall.
Semi-recessed mounted - ceiling.
Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 107
EXTRAC T
G ENI E
TEC HNI C A L I NFO R MATI O N
PERFORMANCE GENIE EXTRACT FANS Casing
Genie Extract Fans
V
120
ISO 5801
BS848 Part 1 2007
100
Fan Static Pressure (Pa)
Surface and semi-recessed (full speed)
80
Duct mounted (full speed)
60
Note: see window kit for window version.
40
Background ventilation
Code descriptions
mode (X, X12 & MX)
20
GENIE H - 12
0
| | |
0 10 20 30 1 2 3
Air volume flow rate (l/s) 1. Genie range
2. Control function
3. Voltage
GENIE FANS - RANGE AND CONTROL FUNCTION
Mounting Operating
Code dBA@3m type voltage Control function
on/off control via light switch link or remote fan switch (by
GENIE 30 surface 230
others), or integral pullcord (no pullcord on M unit).
GENIE - S 30 surface 230
on/off control via light switch link or remote fan switch (by
GENIE - S12 30 surface 12
others) with adjustable run-on timer (5–30 mins.)
GENIE - MS 30 duct 230
GENIE - H 30 surface 230 on/off control via light switch link or remote fan switch (by
GENIE - H12 30 surface 12 others) or via integral pull cord with automatic override by
integral adjustable humidistat.
*GENIE - X 30 surface 230 continuous background ventilation at imperceptible noise level
*GENIE - X12 30 surface 12 with boost duty activated via light switch or remote fan switch
*GENIE - MX 30 duct 230 (by others) or integral pullcord (no pullcord on MX units).
universal fan, continuous ventilation with boost via integral
*GENIE - XH 30 surface 230
humidistat, pull cord or light switch (by others).
universal fan, 12V continuous ventilation with boost via integral
*GENIE - XH12 30 surface 12
humidistat, pull cord or light switch (by others). Purpose made
transformer.
on/off control via integral occupancy sensor with adjustable
GENIE - PIR 30 surface 230
run on timer (5–30 mins.).
*Recommended for optimum humidity and odour control.
Note: Code for Genie Window kit is WinKit.
108 029 2085 8200
EXTR AC T
G ENI E
TEC H NIC A L INFO R MATI O N
DIMENSIONS (MM) WINDOW MOUNTING
The window mounting kit is designed for mounting
Duct mounted unit
the unit into windows 4mm to 32mm thick using a
73 125
125mm dia hole.
Airflow
For further information please refer to Installation
80 document 671182.
200
175
Surface and semi-recessed units
126
73
18 71
80
200 98 OD
173
208
18
Overall width when
Recessed Recessed only
mounting flange 55
provided
WIRING - GENIE SURFACE MOUNTED FANS
230V units via Remote Switch 3 12V units via Pullcord 3
GENIE 1 GENIE - X12 230V 12V 1
GENIE - S N GENIE - H12 N N N N
GENIE - H GENIE - XH Fuse 2 amp
L L L L L
GENIE - X GENIE - XH12
GENIE - XH N E As wiring for remote switch above, E
L 2 excluding switch. 2
Fuse 2 amp Fan
Transformer
The switched Live signal to terminal 2 must be at 230V to enable the fan
12V units via Remote Switch 3
and at 0V to stop the fan after the adjustable timed overrun period.
GENIE - S12 1
Induced voltages in the switched live field wiring can keep the unit running. 230V 12V
GENIE - X12
N N N
GENIE - H12
230V units via Pullcord GENIE - XH L L L
3
GENIE GENIE - XH12 N E
1
GENIE - H N L SL SL 2
N
GENIE - X Fuse 2 amp
L Fan
GENIE - XH L
Transformer
Fuse 2 amp E
2 WIRING - DUCT MOUNTED FANS
230V units via PIR 3 All units are supplied with a 1.5 mtre length of cable connected to the fan,
GENIE PIR 1 to ease installation without having to part the case and to facilitate
N N connection to a fixed electrical supply, via appropriate switched/fused spur.
L L
Wire coding: Live = L, Neutral = N, Switched live = 2, Earth =
Fuse 2 amp E
2 230V units via Remote Switch
GENIE - M
Fan
GENIE - MX
Warning: For EMC compliance the 12V cable should not be fitted
within 50mm of 230V or other cables or on the same tray/ E
trunking if made of metal.
N
The earth connection in the transformer enclosure should not be
used. No earth connection should be made to the 12V fan unit. L
2 amp 2
f
Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 109
EXTRAC T
G ENI E
TEC HNI C A L I NFO R MATI O N
CONSULTA NT S SP E CI F I C ATION
GENIE EXTRACT FAN
The unit shall be manufactured by Nuaire.
The unit shall be either:
a) Surface mountable incorporating a push fit, washable filter with an area of
23,750mm2 and capable of conversion, if necessary, to semi-recessed format
using flange supplied or window mounting format using optional fixing kit.
b) Duct mountable using integral 100mm diameter spigots and fixing brackets
supplied.
Unit noise level shall not exceed 30dBA@3m (24dBA@3m for duct mounted
unit).
The unit shall incorporate an injection moulded forward curved centrifugal
impeller. The impeller shall be directly driven by a motor fitted with sealed, self
lubricating bearings and thermal overload protection.
The fan/motor assembly and the unit control assembly shall be capable of
replacement as "plug in" modules without disturbing the field wiring.
The unit shall be designed for quietest operation to ensure occupant satisfaction.
The unit shall be supplied with a 5 year warranty.
110 029 2085 8200
ST YL I SH KI TCHEN EXTRACT SOLUTION
F O R USE WITH CENTRAL EXTRACT SYSTEM
( M E V, MVHR & CONSTANT PRESSURE)
This easy to clean 60cm stainless steel cookerhood unit is fitted with
two, washable metallic grease filters for quick and easy maintenance.
The push button located on the front of the unit illuminates the
cooking area and provides a switched live signal to trigger boost
function (when linked to a Nuaire MEV, MVHR or damper system).
• Extraction tube 125mm diameter ducting
Metallic grease filters. • Incorporates a simple boost facility – the light switch
on unit acts as trigger for boost facility
• 2 metallic grease filters
• 2 lights
• 2 year warranty
The Cookerhood does not contain a fan. Extract is via a
separate fan unit e.g. MEVDC, MVHR or Constant Pressure CVD.
Coding: CKRH
Push button for lights and boost signal.
Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 111
EXTRAC T
G ENI E NKF 1
TEC HNI C A L I NFO R MATI O N
G E NI E NKF 1 E X T RACT FA NS
POWERFUL KITCHEN EXTRACT FAN WITH
LOW NOISE AND EASY MAINTENANCE.
112 029 2085 8200
EXTR AC T
G ENI E NKF1
TEC H NIC A L INFO R MATI O N
B E NE F I T S
MEETS REGULATIONS QUICK & EASY INSTALLATION AND FLEXIBLE SOLUTION
Complies with Building Regulations. MAINTENANCE Suitable for surface or semi-recessed mounting
Clip in push fit components ensure reduced time on available in 23v and 12v with choice of controls.
EXCELLENT PERFORMANCE site.
Suitable for high moisture producing rooms such as EASY TO CLEAN
kitchens and utility rooms. ECONOMICAL Simply remove filter and wash in warm soapy
Low running costs. water.
EXTREMELY QUIET
Utilising market leading motors to produce the COMPLETE USER SAFETY WARRANTY
quietest of AC fans. Robust flame retardant construction. 5 year warranty for peace of mind.
Easily removed and cleaned filters. MOUNTING OPTIONS
Side bracket of Side bracket of
mounting frame mounting frame
Circular ducting Flexible ducting
Flat duct
Timber
battens
Mounting frame Mounting frame
Wall fixings through Wall fixings through
mounting frame mounting frame
Simple clip in fan and motor assembly. Semi-recessed mounted - wall. Surface mounted - wall. Flexible duct installation.
Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 113
EXTRAC T
G ENI E NKF 1
TEC HNI C A L I NFO R MATI O N
PERFORMANCE - GENIE NKF1 EXTRACT FANS Casing
Genie NKF1
V
150
ISO 5801
BS848 Part 1 2007
125
High speed
Fan Static Pressure (Pa)
100
Low speed
75
Code descriptions
50 NKF1 - RS
Background
ventilation mode Boost speed | |
25
(X & XR) (X & XR mode) 1 2
1. Genie kitchen fan range
0 2. Control function
0 10 20 30 40 50 60 70
Air volume flow rate (l/s)
GENIE NKF1 FANS - RANGE AND CONTROL FUNCTION
Code Operating
Voltage dBA@3m Control Function
NKF1 230 43/18
off/low/high speed control via integral pullcord.
NKF1-RS 230 43/18
on/off and low/high speed control via remote switch (supplied).
NKF1-STD 230 43 on/off high speed control via light switch link or remote fan
switch (by others).
NKF1-H 230 43/18 off/low/high speed control via integral pullcord with automatic override to
high speed via integral adjustable humidistat.
*NKF1-X 230 43/15 continuous background ventilation at imperceptible noise level with boost
via integral pullcord.
*NKF1-XR 230 43/15 Fan with cover removed.
continuous background ventilation at imperceptible noise level with boost
via remote switch (by others).
114 029 2085 8200
EXTR AC T
G ENI E NKF1
TEC H NIC A L INFO R MATI O N
DIMENSIONS (MM)
Duct mounted
337 138 55
72
92
98 0.D.
225 O.A. 158 CTRS
Optional recessed mounting
flange 15mm wide. 230 CTRS
(Fixing kit code 770984)
SEMI-RECESSED FRAME KIT MOUNTED IN WALL APERTURE.
An aperture of 335mm x 245mm
is required for fan and mounting kit
Plastic collar
fits round
exterior of unit
for semi-recessed
mounting
Fan Unit
Cut bracket flush with
mounting surface of wall
Fan unit spigot fits into back of mounting
frame and into ducting
Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 115
EXTRAC T
G ENI E NKF 1
TEC HNI C A L I NFO R MATI O N
WIRING - GENIE NKF1 FANS
Unit ventilating one room. Single speed Unit ventilating one room. (continuous trickle ventilation with boost
(room switch option NKF1STD only). via remote double pole switch NKF1-XR).
Double pole switch (by others)
3 3
1 1
N N N N
Room light
L L L
Switch
L 2 2
Fuse 2 amp max.
Unit ventilating one room. Two speed Unit ventilating one room. Two speed
(pull cord option NKF1, NKF1H, NKF1-X). (remote switch option NKF1-RS).
N L
3 3
1 1
ON OFF
L2 L3 N
N N
L1
L L Not
L used
Fuse 2 amp max.
HIGH LOW
L3
L2
2 2
L1
Two gang, two way switch (supplied)
116 029 2085 8200
EXTR AC T
G ENI E NKF1
TEC H NIC A L INFO R MATI O N
CO NSULTA NT S SP E CI FIC ATION
GENIE NKFI KITCHEN FAN
The unit shall be manufactured by Nuaire.
The unit shall be surface mountable incorporating a push fit, washable filter with
the area of 34,750mm2 and capable of conversion, if necessary, to semi-recessed
format using optional flange.
Unit noise levels shall not exceed 43dBA@3m.
The unit shall incorporate an injection moulded, forward curved centrifugal
impeller. The impeller shall be directly driven by a motor fitted with seated, self
lubricating bearings and thermal overload protection.
The fan/motor assembly and the unit control assembly shall be capable of
replacement as "plug in" modules without disturbing the unit field wiring.
The unit shall be designed for quiet operation to ensure complete occupant
satisfaction. The unit code, mounting type, operating voltage and control
function shall be as shown in the performance table.
The unit shall be supplied with a 5 year warranty.
Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 117
EXTRAC T
SL I MA I R E SINGL E SPEED
TEC HNI C A L I NFO R MATI O N
SL IM A I RE 230 V & 1 2 V SI NGL E SPEED FANS
EXCEPTIONALLY QUIET, HIGH PERFORMANCE EXTRACT FANS FOR
WALL AND CEILING APPLICATIONS.
118 029 2085 8200
EXTR AC T
SL I MA I R E SING L E SP EED
TEC H NIC A L INFO R MATI O N
B E NE F I T S
MEETS REGULATIONS EASY INSTALLATION FIXED BACK DRAUGHT SHUTTERS
Part F Building regulations compliant. Can be surfaced mounted or recessed. Prevents draughts when fan not in operating mode.
ULTRA MODERN DESIGN FLEXIBLE SOLUTIONS 1 YEAR WARRANTY
Provides an unobtrusive installation and occupant Wide range of options to cover toilet, bathroom, For peace of mind.
acceptability. utility and kitchen applications.
IPX4 SPLASHPROOF MAINTENANCE
Can safely be installed in Zones 1 and 2. Clip of cover of access to clean.
QUIET RUNNING FAN INDICATOR LIGHT
For occupant acceptability. Showing the fans operation.
SLIMAIRE 100 & 150 SINGLE SPEED MOUNTING OPTIONS
FANS
The Nuaire slimline range of axial fans
incorporates 12 models complete with
fixed back draft shutters. The fans have been
specifically designed to ventilate small rooms
such as toilets, bathrooms, shower rooms,
utility rooms and kitchens and are ideal for
wall, ceiling or panel installation. The units
extract directly to outside or through a short
length of ducting.
Wall mounting with outside grille. Ceiling mounting with outside roof cap.
Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 119
EXTRAC T
SL I MA I R E SINGL E SPEED
TEC HNI C A L I NFO R MATI O N
PERFORMANCE SLIMLINE 100 & 150 SINGLE SPEED FANS
70
60
50
Slimaire 150
Fan Static Pressure (Pa)
40
30
Slimaire 100
20
10
0
0 10 20 30 40 50 60 70 80 90
Air volume flow rate (l/s)
SLIMLINE 100 & 150 - RANGE & CONTROL FUNCTION
Operating
Code dBA@3m voltage Control function
SLIMAIRE 100/150 40/49 230 Standard version operated by remote switch.
SLIMAIRE 100PC/150PC 40/49 230 Standard version operated by pull cord.
SLIMAIRE 100T/150T 40/49 230 With integral overrun timer - the fan should be operated by a
remote switch which can also serve to switch the room light on
and off. After the light is switched off, the fan will continue to
operate for a minimum of 3 minutes (adjustable to a maximum
of 25 minutes) by turning the trimmer in a clockwise direction.
SLIMAIRE 100HT/150HT 40/49 230 With integral humidistat and overrun timer - the adjustable,
electronic humidistat is pre-set so that the fan will operate
automatically when the moisture content in the room reaches
a pre-set level of relative humidity. The fan will continue to run
until the relative humidity falls below the pre-set level.
This level can be adjusted by turning the trimmer on the fan.
This fan can be operated by a remote switch or light switch
allowing operation of the fan independently of the humidistat.
The overrun timer, which will always make the fan continue to
operate for the pre-set length of time even after it has been
manually switched off, can be adjusted as described above.
SLIMAIRE 100PIR/150PIR 40/49 230 With integral sensor and overrun timer - the fan will start to
operate automatically when it detects the presence of a person.
After the room is vacated, the fan will continue to operate
for a minimum of 3 minutes (adjustable to a maximum of
25 minutes) by turning the trimmer in an anti-clockwise
direction.
SLIMAIRE 100-12 40 12 This version must be installed using the remote transformer
supplied (see current IEE Regulations for guidance).
SLIMAIRE 100T-12 40 12 With integral overrun timer adjusted as above.
This version must be installed using the remote transformer
supplied (see current IEE Regulations for guidance).
120 029 2085 8200
EXTR AC T
SL I MA I R E SING L E SP EED
TEC H NIC A L INFO R MATI O N
DIMENSIONS (MM) - SLIMLINE 100 & 150 SINGLE SPEED FANS
B
D
DIMENSIONS (mm) & WEIGHTS
Weight
Unit A B C D E dia. (Kg)
A E
SLIMAIRE 100 160 160 81 17 97 0.42
SLIMAIRE 150 200 200 119 22 149 1.04
C
WIRING - SLIMLINE 100 & 150 SINGLE SPEED FANS
SLIMAIRE 100/150 with remote switch. SLIMAIRE 100PC/150PC with pullcord. SLIMAIRE 100T/150T
via light switch (or remote switch).
L L 230V L L 230V N N 230V
~
50Hz ~ ~
50Hz
50Hz T L
N N N N
L
Double Pole Isolator Double Pole Isolator
Triple Pole Isolator
SLIMAIRE 100/150HT PIR with Humidistat SLIMAIRE 100-12, 12V SLIMAIRE 100T-12, 12V via light switch
and Integral sensor. Must be installed with remote transformer. (or remote switch).
Must be installed with remote transformer.
Transformer Transformer
L L 230V
~
50Hz
N N
L N L N L N L N
Double Pole Isolator
12V 230V 12V 230V
230V
L N ~
50Hz
L
N L N
T
Fan unit Double Pole Isolator Fan unit Triple Pole Isolator
Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 121
EXTRAC T
SL I MA I R E TW IN SPEED
TEC HNI C A L I NFO R MATI O N
SL IM A I RE 230 V & 1 2 V T WIN SP EED FANS
EXCEPTIONALLY QUIET, HIGH PERFORMANCE EXTRACT FANS FOR
WALL/WINDOW AND CEILING APPLICATIONS.
122 029 2085 8200
EXTR AC T
SL I MA I R E TWIN SP EED
TEC H NIC A L INFO R MATI O N
B E NE F I T S
MEETS REGULATIONS ENERGY EFFICIENT MODERN DESIGN CONTINUOUS RUNNING
Part F Building regulations compliant. Low running costs. For guaranteed ventilation.
IPX4 SPLASHPROOF BOOST FACILITY MAINTENANCE
Can safely be installed in Zones 1 and 2. For additional airflow via pull cord. Clip of cover of access to clean.
QUIET RUNNING FLEXIBLE SOLUTIONS 1 YEAR WARRANTY
For occupant acceptability. Can be surfaced mounted, wall panel window or For peace of mind.
recessed. (Window kits available - WINKIT100X -
WINKIT150X).
MOUNTING OPTIONS
The Nuaire Slimaire range of SELV and 2 speed axial fans incorporates 3 models. They are ideal
for ventilating small rooms such as toilets, bathrooms, cloakrooms and kitchens etc and can be
installed on wall, ceiling, panel or window.
Window mounting with outside grille. Wall mounting with outside grille. Ceiling mounting with outside roof cap.
Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 123
EXTRAC T
SL I MA I R E TW IN SPEED
TEC HNI C A L I NFO R MATI O N
WIRING - SSLIMLINE 100X & 150X TWIN SPEED FANS PERFORMANCE SLIMAIRE 100X & 150X AXIAL FANS
L L 230V L L 230V
SLIMAIRE 100XPC/150XPC with integral cord. ~
50Hz 70
~
50Hz
N N N N
L L 230V N 230V
~
50Hz
N
60 ~
50Hz
Double Pole Isolator N T Double Pole Isolator
N L
Slimaire 150X
L 50
T
Fan Static Pressure (Pa)
N Double Pole Isolator N 230V L Triple Pole Isolator L 230V
~
50Hz
40 ~
50Hz
SLIMAIRE 100XPC/150XPC
T L
N N
L 230V N 230V 30
~
50Hz
N L
~
50Hz
N T L Slimaire 100X
Triple Pole Isolator 20
Double Pole Isolator
L
10
e Isolator Triple Pole Isolator
SLIMAIRE 100XPC-12, 12V with integral cord. 0
0 10 20 30 40 50 60 70 80 90 100
Transformer Transformer
L 230V L L 230V
~
50Hz
~
50Hz
Air volume flow rate (l/s)
N N N
SLIMAIRE 100X & 150X- RANGE & CONTROL FUNCTION
ator L Double Pole Isolator
N L N L N L N
Operating
Code dBA@3m voltage Control function
12V 230V 12V 230V
SLIMAIRE 100XPC 39 230 Continuous low duty with boost
N 230V L L 230V facility operated by pull cord
~ ~ 230V 230V or remote switch.
L
50Hz L
N
50Hz N ~
50Hz
L ~
50Hz
N SLIMAIRE 100XPC-12 39 12 Continuous low duty with boost
N L N N facility operated by pull cord
T L or remote switch, 12V SELV.
This version must be installed
or Double Pole Isolator using the remote transformer
Fan unit Double Pole Isolator Fan unit Triple Pole Isolator supplied (see current
IEE Regulations for guidance).
SLIMAIRE 100XPC-12, 12V with remote switch. SLIMAIRE 150XPC 49 230 Continuous low duty with boost
(Pull-cord switch must be OFF before removing cord). facility operated by pull cord
or remote switch.
er Transformer
SLIMAIRE 150XPC-12 49 12 Continuous low duty with boost
facility operated by pull cord
or remote switch, 12V SELV.
This version must be installed
using the remote transformer
L N L N supplied (see current
IEE Regulations for guidance).
12V 230V
DIMENSIONS (MM) SLIMAIRE 100X & 150X
230V 230V
N ~
50Hz
L ~
50Hz
B
D
L N N
T L
Isolator Fan unit Triple Pole Isolator
A E
C
DIMENSIONS (mm) & WEIGHTS
Weight
Unit A B C D E dia. (Kg)
SLIMAIRE 100 155 155 92 35 97 0.5
SLIMAIRE 150 209 209 137 52 149 1.2
124 029 2085 8200
EXTR AC T
SL I MA I R E
TEC H NIC A L INFO R MATI O N
CO NSULTA NT S SP E CI FIC ATION
SLIMAIRE 100 & 150 SINGLE SPEED FANS SLIMAIRE 100X & 150X TWIN SPEED FANS
Supplied by Nuaire Ltd the fan is to be suitable for installation either into a Supplied by Nuaire, this fan can either be for installation in a wall, panel, ceiling
ceiling, wall or panel (with the appropriate accessories) There should be a neon or window (with optional kit). The fan should have three speeds, allowing a
on the front of the fan to indicate when it is operating. The fan casing should be choice of one of the two lower speeds for quiet, continuous operation at
made of shockproof, high quality technopolymer, contain double insulated installation. The user should be able to boost the fan to its maximum speed as
motors of shaded poly type mounted on self-lubricating, sealed ball bearings for necessary. The fan should be made of shockproof high quality polymer and have
long life, and be protected with a thermal cut-out.. The fan should be double a maintenance free, self lubricating sleeve bearing motor for long life and
insulated and be suitable for installation into Zones I and II. The fan is to be CE incorporates thermal cut-out.. The fan should be double insulated, splashproof
marked and comply with current EC Low Voltage Directive EMC89/336 and with and CE marked. The fan should comply with Kitchen and Bathroom
BSEN60529. The fan should finally comply with Building Regulations requirements of System 3, Part F1 of the Building Regulations. It should be
requirements for installation into a utility room. capable of operation up to 9 l/sec, at 4 Pa, 2.6 watts at low speed 1, and at 12
l/sec, 14 Pa and 4.8 watts at low speed 2. Finally the fan should comply with EN
60335-2-80, EC Low Voltage Directive LVD 2006/95/CE and EC Directive
EMC2004/108 and be CE marked.
Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 125
EXTRAC T
C O O K ERH O O D
TEC HNI C A L I NFO R MATI O N
COO KE RHO O D E X T RACT FA NS
HIGH PERFORMANCE, STAINLESS STEEL COOKERHOOD.
126 029 2085 8200
EXTR AC T
C O O KER H O O D
TEC H NIC A L INFO R MATI O N
B E NE F I T S
HIGH PERFORMANCE Pressure Drop 07 - COOKERHOOD SS with lights on
424m3/hr extraction capacity through tangential 110
V
motor. 100
90 ISO 5801
EASE OF USE BS848 Part 1 2007
80
Simple push button control to generate speed and Static Pressure (Pa) Speed 3
lighting. 70
60
EASY CLEAN
50
Stainless steel 600mm cookerhood and integral
grease filters. 40
Speed 2
30
OPTIONAL EXTRA’S
20
2 x S1 carbon filters for air recirculation. Speed 1
10
2 YEAR WARRANTY 0
0 20 40 60 80 100 120
Air volume flow rate (l/s)
SPECIFICATIONS
Casing shall be manufactured from easy to clean the manufacturers instruction and maintenance
stainless steel. manual (available from www.nuairegroup.com).
The unit is fitted with two, washable metallic grease Note: the cooker hood will need to be sited
filters for quick and easy maintenance. a minimum of 650mm above the hob.
The hood must be fitted in accordance with
DIMENSIONS (MM)
221mm
170mm
Min 700/Max 1080
500mm
300mm
600mm
40mm
Code description COOKERHOODC-SS Metallic grease filters.
Download specification from www.nuaire.co.uk/specifications nuaire.co.uk 127
EXTRAC T
AC O USTIC VENTIL ATO R
TEC HNI C A L I NFO R MATI O N
Acoustically treated ventilator
minimises noise polution
when background ventilation
is required.
The provision of fresh air for rapid ventilation to all apartments is to be The unit dimensions shall be 450mm wide x 200mm high x 200mm
available without any inconvenience that may be caused by noise deep (min), the depth of the unit shall be telescopic to suit different wall
pollution from the road immediately adjacent to the development. thicknesses; this facility shall not affect the acoustic properties or the air
To this end any apartments situated on the main road are to be provided flow characteristics of the acoustic ventilator.
with an acoustically treated ventilator. These are to be situated in the
The acoustic media used within the unit shall be flame retardant
external wall of any room overlooking the road.
material, Class 0 rated.
N.B. ALL rooms in corner/end apartments where one or more rooms
Unit shall be all as per model reference ACC-400 as manufactured by
overlook the road are to have the acoustic ventilators provided,
Nuaire Ltd.
regardless of that particular room’s proximity to the road.
The unit shall have a 5 year warranty.
Features:
• Manual operation for total flexibility Acoustic Performance –
• Airflow 38l/s @ 50Pa when fully open (Summary – for full data see SRL test report C/04/5L/3108/1
method BS EN ISO 717-1:1997).
• Prevents ingress of wind, rain etc with externally fitted baffle
Vent in closed position:- Rw (C;Ctr) 54
• Aluzinc finish can be painted to allow blending into any
environment Vent in open position:- Rw (C;Ctr) 46
• Telescopic design allows for differing wall thicknesses For comparison, 220mm cavity wall without penetration:-
Rw (C;Ctr) 58
• Class 0 rated flame retardant acoustic material
• SRL test report available
700
• 3 year warranty 650
600
The acoustic ventilator shall be a manually operated device used at the
550
discretion of the apartment’s occupier and when in use shall allow fresh 500
Static Pressure (Pa)
air to pass into the room in question. The fresh air flow will be a 450
combination of natural infiltration and fan assisted via the apartment’s 400
ventilation system. The unit’s air flow characteristic shall be 38l/s @50Pa 350
when the adjustable regulating plate is fully open. When the acoustic 300
ventilator is in use any externally generated noise from the adjacent road 250
shall be kept to acceptable levels and shall be equivalent to that of the 200
particular unit specified elsewhere in this document. 150
100
The acoustic ventilator shall have a baffle plate mounted externally and 50
an adjustable regulating plate on the internal face both suitable for paint 0
finishing. The external baffle shall act as a weather shield stopping the 0 10 20 30 40 50 60 70
ingress of wind, rain, etc. and shall be manufactured from aluminium Air brick set-up resistance
alloy. The adjustable regulating plate shall be of a blank appearance so as
to appear neutral to the wall in which it is situated. The adjustable
regulating plate will be hinged for operation; the hinge mechanism will
be graduated to facilitate the adjustment.
The unit casing shall be manufactured from Aluzinc corrosion protected
steel and shall be of a minimum 1.5mm thickness.
128 029 2085 8200