FLARE STACK DATA SHEET
COMPANY: DATE:
ADDRESS: CLOSING DATE:
PROJECT:
CONTACT: LOCATION/REF#:
PHONE: FAX: EMAIL:
TYPE OF FLARE
1- FLARE: NEW EXISTING
2- FARE SYSTEM: ELEVATED GROUND PIT
3- FLARE SUPPORT: GUYED SELF SUPPORTED DERRICK
PROCESS DATA
1- FLOW RATE: MAXIMUM: 2- GAS TEMP: / /
scfh m3/hr MINIMUM:
O
C O
F MAXIMUM / NORMAL / MINIMUM
lb/hr kg/hr CONTINUOUS:
SMOKELESS: 3- AVERAGE MOLE WEIGHT:
4- GAS COMPOSITION (mole %):
C1 C2 C3 IC4 NC4 IC5 NC5 C6 C6+
C7 C8 C9 C10 CO2 H2 S O2 H2O N2
H2 NH3 He OTHER
5- ALLOWABLE PRESSURE DROP: TIP: 6- HEATING VALUE:
psig kpa SEAL: btu/scf kj/nm3
2
barg kg/cm STACK: btu/lb kj/kg
7- ALLOWABLE EXIT VELOCITY: mach: ft/sec: m/sec:
SITE CONDITIONS AND UTILITIES
1- AMBIENT TEMP: / 2- FUEL GAS / INSTRUMENT AIR: /
O
C O
F MAXIMUM / MINIMUM psig kpag
3- POWER AVAILABLE: / / 4- ELEVATION ABOVE SEA LEVEL:
YES NO VOLTS / PHASES / HERTZ meters feet
5- MAXIMUM WIND VELOCITY (STRUCTURAL): 6- EARTQUAKE ZONE:
mph m/s - DIRECTION: 7- RELATIVE HUMIDITY (%): /
MAXIMUM / MINIMUM
DESIGN CRITERIA
1- MAXIMUM RADIATION LEVEL: @ STACK BASE: INCLUDE SOLAR:
btu/hr/ft2 kw/m2 @ ft/m RADIUS: YES NO SOLAR VALUE
2- MAXIMUM WIND VELOCITY (RADIATION): 3- SMOKE:
mph m/s NON SMOKELESS SMOKELESS % (degree of smokeless)
4- MAXIMUM NOISE LEVEL (dba) ALLOWED @ DISTANCE FROM STACK BASE: 5- MAXIMUM H2S CONCENTRATION (ppm) @ DISTANCE FROM STACK BASE:
dba @ ft m ppm @ ft m
6- MAXIMUM SO2 CONCENTRATION (ppm) @ DISTANCE FROM STACK BASE:
ppm @ ft m
MACTRONIC QUOTE #: MACTRONIC PROJECT #:
MACTRONIC FLARE DATA SHEET. 1 JUNE, 1999.
FLARE EQUIPEMENT
1- STACK DIAMETER: ft m 2- STACK HEIGHT: ft m 3- STACK MATERIAL:
4- TIP DIAMETER: ft m 5- TIP HEIGHT: ft m 6- TIP MATERIAL:
7- PROCESS GAS/INLET DIAMETER: in mm 8- FLANGE RATING:
9- CORROSION ALLOWANCE (carbon steel): in mm 10- GAS SEAL: YES NO PURGE/FLUIDIC SEAL MOLECULAR
11- WATER SEAL: YES NO VERTICAL HORIZONTAL IN STACK BASE
12- KNOCK OUT DRUM: YES NO VERTICAL HORIZONTAL IN STACK BASE
13- WATER SEAL / KNOCK OUT DRUM: DESIGN CODE: MATERIAL:
14- TYPE OF TIP PREFFERED IF SMOKELESS IS REQUIRED: AIR INJECTED STEAM INJECTED GAS INJECTED NATURAL DRAFT (no utilities)
15- STEAM AVAILABLE (for steam injected flare tips):
PRESSURE: TEMPERATURE: MAXIMUM QUANTITY AVAILABLE:
psig kpa barg kg/cm2 O
C O
F lb/hr kg/hr
16- STEAM CONTROL SYSTEM: YES NO MANUAL AUTOMATIC
FLARE IGNITION EQUIPEMENT
1- TYPE OF FLARE IGNITION: ELECTRONIC (recommended) FLAME FRONT GENERATOR
2- IGNITION SYSTEM OPERATION: MANUAL MANUAL/AUTOMATIC
3- PILOTS: YES NO NUMBER REQUESTED OR BY MACTRONIC
4- PILOT FLAME MONITOR: YES NO THERMOCOUPLE UV MONITOR
5- AREA CLASSIFICATION FOR CONTROL PANEL:
6- DISTANCE FROM CONTROL PANEL TO STACK BASE: ft m
7- IGNITOR RETRACTABILITY: YES NO MACTRONIC RECOMMENDATION
8- POWER AVAILABLE: YES NO / / ( VOLTS / PHASE / HERTZ )
MISC. FLARE IGNITION EQUIPEMENT
ELECTRONIC IGNITION CONTROL PANEL FAILURE ALARM SHOT TUBE REMOTE TELEMETRY SYSTEM
STATIONARY PILOT POWER CABLE FROM STACK/PIT TO CONTROL PANEL RETRACTABLE PILOT CONTROL PANEL STAND
FLAME PROVING THERMOCOUPLE THERMOCOUPLE CABLE FROM STACK/PIT TO CONTROL PANEL RETRACTABLE PILOT/IGNITOR
SENTINEL UV FLAME MONITOR SOLAR POWERED IGNITION
MISC. FLARE EQUIPEMENT
LADDER & PLATFORM AIRCRAFT WARNING LAMPS: WELDED FLARE SECTION VENDOR FIELD ASSISTANCE
PAINTER'S TROLEY STATIONARY RETRACTABLE FLANGED FLARE SECTION FREIGHT: F.O.B.
FLARE BURNER REMOUVAL DAVIT TIP LADDER RUNGS SINGLE POINT LIFT C.I.F.
MANUALS # OF COPIES: