TRIPLITE MODEL --> PV150 PV375 PV600

SYSTEM OVERVIEW

System overview: Compact 12 volt DC to Compact 12 volt DC to Compact 12 volt DC to

120 volt AC power 120 volt AC power 120 volt AC power

inverter. 150 watts inverter. 375 watts inverter. 600 watts

continuous / 300 watts continuous / 600 watts continuous / 1200 watts

peak. Cigarette lighter peak. Cigarette lighter peak. Requires hardwire

input jack, 1 AC outlet. input jack, 2 AC outlets. DC installation, 3 AC

outlets.









Voltage compatibility: Compatible with 12VDC Compatible with 12V DC Compatible with 12V DC

automotive systems automotive systems automotive or battery

power sources

Frequency compatibility: 60 Hz 60 Hz 60 Hz

Price: $44.99 $69.99 $119.99

OUTPUT

Output watt capacity (watts): 150 watts continuous, 375 watts continuous, 600 watts continuous,

supports peak output up supports peak output up supports peak output up

to 300 watts for up to 500 to 600 watts for up to 500 to 1200 watts for up to

milliseconds milliseconds 500 milliseconds



Output nominal voltage: 120V nominal 120V nominal 120V nominal

Output voltage regulation: Maintains PWM sine Maintains PWM sine Maintains PWM sine

wave output voltage of wave output voltage of wave output voltage of

115 VAC (+/- 8 VAC) 115 V AC (+/- 8 V AC) 115 V AC (+/- 8 V AC)

Output frequency regulation: 60 Hz (+/- 3 Hz) 60 Hz (+/- 3 Hz) 60 Hz (+/- 3 Hz)

Outlet quantity / type: Includes 1 NEMA 5-15R Includes 2 NEMA 5-15R Includes 3 NEMA 5-15R

output receptacle output receptacles output receptacles



Overload protection: Via 20A automotive input Via 40A automotive input Via set of 2 40A

fuse fuse automotive input fuses









INPUT

Maximum input amps / watts: Full continuous load - Full continuous load - Full continuous load -

14A at 12VDC, No load - 40A at 12V DC, No load - 64A at 12V DC, No load -

0.4A at 12VDC 0.65A at 12V DC 0.95A at 12V DC,

Shutdown - 150

microamps

Input connection type: 12VDC cigarette lighter 12V DC cigarette lighter Set of 2 DC bolt-down

input plug connection input plug connection wiring terminals





Input cord length: 3 ft. hardwire input cable, 3 ft. hardwire input cable, User supplies cabling.

16 gauge, 2 wire 16 gauge, 2 wire Minimum gauges for full

load operation: 8 (6 ft

max), Two 10 (8 ft max),

6 (10 ft max), 4 (15 ft

max).



Recommended electrical Requires 12V DC input

service: source capable of

delivering 64A for the

required duration (when

used at full capacity). For

automotive applications,

professional hardwire

installation with 80A

battery system fusing is

recommended.







BATTERY

DC system voltage: DC input operating range DC input operating range DC input operating range

10-15VDC. Alarm 10-15V DC. Alarm 10-15V DC. Alarm

sounds as voltage drops sounds as voltage drops sounds as voltage drops

to 10.5V. Auto-shutdown to 10.5V. Auto-shutdown to 10.5V. Auto-shutdown

occurs at 10V. occurs at 10V. occurs at 10V.





LEDS ALARMS &

SWITCHES

Front panel LEDs:









Alarms: Dual function alarm Dual function alarm Dual function alarm

indicates overload indicates overload indicates overload

conditions or low DC conditions or low DC conditions or low DC

input voltage of 10.5V or input voltage of 10.5V or input voltage of 10.5V or

less. less. less.

Switches: Lighted on/off power Lighted on/off power Lighted on/off power

switch switch switch









PHYSICAL

Shipping weight (lbs): 1.3 2.3 3

Shipping weight (kg): 0.59 1.04 1.4

Unit weight (lbs): 1.2 2.2 2.5

Unit weight (kg): 0.54 0.99 1.1

Unit Dimensions (HWD/in): 1.75 x 3.75 x 5.75 2 x 4.25 x 7 2.75 x 5 x 8.25

Unit Dimensions (HWD/cm): 4.45x 9.5 x 14.6 5 x 10.8 x 17.8 7 x 12.7 x 21

Shipping Dimensions 8 x 5 x 1.65 11.5 x 7.3 x 2.2 4 x 6.5 x 10.25

(HWD/in):

Shipping Dimensions 20.3 x 12.7 x 4.2 29.2 x 18.54 x 5.59 10.2 x 16.5 x 26

(HWD/cm):

Material of construction: Aluminum / sheet metal Aluminum / sheet metal Aluminum / sheet metal



Cooling method: Convection Fan Fan

Form factors supported:









ENVIRONMENTAL

Operating Temperature: 32-104 Fahrenheit / 0-40 32-104 Fahrenheit / 0-40 32-104 Fahrenheit / 0-40

Celcius Celcius Celcius

Relative Humidity: 0-95% non-condensing 0-95% non-condensing 0-95% non-condensing



WARRANTY

Product warranty: 1 year (Outside the U.S. 1 year (Outside the U.S. 1 year (Outside the U.S.

and Canada, call for and Canada, call for and Canada, call for

warranty information) warranty information) warranty information)



SPECIAL FEATURES

TVSS grounding:









Appearance: Attractive, rugged, Attractive, rugged, Attractive, rugged,

metallic red color inverter metallic blue color metallic gray color

system inverter system inverter system

Load Sensing:









TRIPLITE MODEL --> PV150 PV375 PV600

POWER INVERTER MAIN

BOAT GEAR



HOME PAGE

PV1000HF PV1800HF PV3000HF

Compact 12 volt DC to Compact 12 volt DC to Compact 12 volt DC to

120 volt AC power 120 volt AC power 120 volt AC power

inverter. 1000 watts inverter. 1800 watts inverter. 3000 watts

continuous / 2000 watts continuous / 3000 watts continuous / 6000 watts

peak. Requires hardwire peak. Requires hardwire peak. Requires hardwire

DC installation, 4 AC DC installation, 3 AC DC installation, 4 AC

outlets outlets outlets. Includes corded

remote power control

module.





Compatible with 12VDC Compatible with 12VDC Compatible with 12VDC

automotive or battery automotive or battery automotive or battery

power sources power sources power sources

60 Hz 60 Hz 60 Hz

$249.99 $399.99 $699.99



1000 watts continuous, 1800 watts continuous, 3000 watts continuous,

supports instantaneous supports peak output up supports peak output up

peak output up to 2000 to 3600 watts for up to to 6000 watts for up to

watts 500 milliseconds 500 milliseconds



120V nominal 120V nominal 120V nominal

Maintains PWM sine Maintains PWM sine Maintains PWM sine

wave output voltage of wave output voltage of wave output voltage of

115 VAC (+/- 8 VAC) 115 VAC (+/- 8 VAC) 115 VAC (+/- 8 VAC)

60 Hz (+/- 3 Hz) 60 Hz (+/- 3 Hz) 60 Hz (+/- 3 Hz)

Includes 4 NEMA 5-15R Includes 3 NEMA 5-15R Includes 4 AC outlets (2

output receptacles output receptacles NEMA 5-15R and 2

NEMA 5-20R)

Automatic overload Automatic overload Automatic overload

protection shuts down protection shuts down protection shuts down

inverter system in the inverter system in the inverter system in the

event of overloads. event of overloads. event of overloads.

Inverter and electrical Inverter and electrical Output is protected by 2

system are further system are further built-in 20A circuit

protected via four internal protected via set of 6 breakers (each

40A automotive fuses 40A automotive input controlling power to 2

fuses. outlets). Inverter and

electrical system are

further protected via set

of 6 40A automotive

input fuses.







Full continuous load - Full continuous load - Full continuous load -

100A at 12V DC, No load 200A at 12VDC, No load - 286A at 12VDC, No load -

- 1.5A at 12V DC, 2.7A at 12VDC, 1.5A at 12VDC,

Shutdown / load sense Shutdown Shutdown / load sense

mode - 100 microamps mode - less than 100

microamps

Set of 2 DC bolt-down Set of 2 DC bolt-down DC INPUT: Set of 4 DC

wiring terminals wiring terminals bolt-down terminals (2

red / 2 black). AC INPUT:

hardwire

User supplies cabling. User supplies cabling. User supplies cabling.

Minimum gauges for full Minimum gauges for full Minimum gauges for full

load operation: 4 (12 ft load operation: 0 (16 ft load operation: 0 (10 ft

max), 2 (20 ft max), 0 (31 max), 00 or 2/0 (20 ft max), 00 or 2/0 (13 ft

ft max). max) max), Twin 00 using 4

conductors (26 ft)



Requires 12V DC input Requires 12VDC input Requires 12VDC input

source capable of source capable of source capable of

delivering 100A for the delivering 200A for the delivering 286A for the

required duration (when required duration (when required duration (when

used at full capacity). For used at full capacity). For used at full capacity). For

automotive applications, automotive applications, automotive applications,

professional hardwire professional hardwire professional hardwire

installation with 175A installation with 250A installation with 500A

battery system fusing is battery system fusing is battery system fusing is

recommended. recommended. recommended.









DC input operating range DC input operating range DC input operating range

10-15VDC. Alarm 10-15VDC. Alarm 10-15VDC. Alarm

sounds as voltage drops sounds as voltage drops sounds as voltage drops

to 10.5V. Auto-shutdown to 10.5V. Auto-shutdown to 10.5V. Auto-shutdown

occurs at 10V. occurs at 10V. occurs at 10V.









Set of 6 LEDs offer Dual function alarm Set of 6 LEDs offer

continuous status indicates overload continuous status

information on battery conditions or low DC information on load

and connected load input voltage of 10.5V or percentage (5 levels

conditions less. reported) and battery

charge level (7 levels

reported). See manual

for sequences.

Dual function alarm Dual function alarm

indicates overload indicates overload

conditions or low DC conditions or low DC

input voltage of 10.5V or input voltage of 10.5V or

less. less.

3 position rocker switch 3 position rocker switch

enables on/off power enables on/off power

control, plus "remote" control, plus "remote"

setting which enables setting which enables

inverter to be remotely inverter to be remotely

powered on or off when powered on or off when

used in conjunction with used in conjunction with

APSRM4 Remote included APSRM2

Control Module (sold module.

separately)







5.6 9.2 13.7

2.5 4.17 6.2

5 7.4 12.2

2.1 3.36 5.5

3.75 x 6 x 12.5 4 x 10 x 10.5 4.1 x 11.1 x 14

9.5 x 15.2 x 31.8 10.2 x 25.4 x 26.7 10.4 x 28.2 x 35.6

4 x 6.5 x 13 4.5 x 12 x 12 4.3 x 12.5 x 14.8



10.2 x 16.5 x 33 11.4 x 30.5 x 30.5 10.9 x 31.8 x 37.6



Aluminum / sheet metal Aluminum / sheet metal Aluminum / sheet metal



Fan Fan Fan

Mounting slots enable Mounting slots enable Mounting slots enable

permanent placement of permanent placement of permanent placement of

inverter on any horizontal inverter on any horizontal inverter on any horizontal

surface (see manual for surface (see manual for surface (see manual for

additional mounting additional mounting additional mounting

information) information) information)





32-104 Fahrenheit / 0-40 32-104 Fahrenheit / 0-40 32-104 Fahrenheit / 0-40

Celcius Celcius Celcius

0-95% non-condensing 0-95% non-condensing 0-95% non-condensing







1 year (Outside the U.S. 1 year (Outside the U.S. 1 year (Outside the U.S.

and Canada, call for and Canada, call for and Canada, call for

warranty information) warranty information) warranty information)







Grounding lug grounds Grounding lug grounds Grounding lug grounds

the inverter to vehicle or the inverter to vehicle or the inverter to vehicle or

earth ground - user earth ground - user earth ground - user

supplies cabling supplies cabling supplies cabling



Attractive, rugged, Attractive, rugged, Attractive, rugged,

metallic gray color metallic gray color metallic gray color

inverter system inverter system inverter system

Optional load sense Optional load sense

function conserves function enables

battery power by setting automatic inverter shutoff

the load-level at which and startup as connected

the inverter automatically equipment is powered off

shuts off. and on. Front panel load

sense potentiometer can

be set to shutoff or turn

on inverter power in

response to loads of any

level, up to 150 watts.









PV1000HF PV1800HF PV3000HF


Related docs
Other docs by HC111123023026
Week of August _____ 2009
Views: 0  |  Downloads: 0
KCSD Pacing Guide for 1st Grade Mathematics
Views: 7  |  Downloads: 0
12th GRADE ENGLISH LITERATURE/COMPOSITION
Views: 0  |  Downloads: 0
Reading/Language Arts
Views: 0  |  Downloads: 0
ALTAIR � 4X Multigas Detector
Views: 2  |  Downloads: 0
Course Catalog 2010 2011
Views: 0  |  Downloads: 0
Sheet1
Views: 2  |  Downloads: 0
Sheet1
Views: 35  |  Downloads: 0
Slide 1
Views: 0  |  Downloads: 0
OFFICE OF THE DY
Views: 1  |  Downloads: 0
By registering with docstoc.com you agree to our
privacy policy

You are almost ready to download!

You are almost ready to download!