TRIPLITE MODEL --> PV150 PV375 PV600
SYSTEM OVERVIEW
System overview: Compact 12 volt DC to Compact 12 volt DC to Compact 12 volt DC to
120 volt AC power 120 volt AC power 120 volt AC power
inverter. 150 watts inverter. 375 watts inverter. 600 watts
continuous / 300 watts continuous / 600 watts continuous / 1200 watts
peak. Cigarette lighter peak. Cigarette lighter peak. Requires hardwire
input jack, 1 AC outlet. input jack, 2 AC outlets. DC installation, 3 AC
outlets.
Voltage compatibility: Compatible with 12VDC Compatible with 12V DC Compatible with 12V DC
automotive systems automotive systems automotive or battery
power sources
Frequency compatibility: 60 Hz 60 Hz 60 Hz
Price: $44.99 $69.99 $119.99
OUTPUT
Output watt capacity (watts): 150 watts continuous, 375 watts continuous, 600 watts continuous,
supports peak output up supports peak output up supports peak output up
to 300 watts for up to 500 to 600 watts for up to 500 to 1200 watts for up to
milliseconds milliseconds 500 milliseconds
Output nominal voltage: 120V nominal 120V nominal 120V nominal
Output voltage regulation: Maintains PWM sine Maintains PWM sine Maintains PWM sine
wave output voltage of wave output voltage of wave output voltage of
115 VAC (+/- 8 VAC) 115 V AC (+/- 8 V AC) 115 V AC (+/- 8 V AC)
Output frequency regulation: 60 Hz (+/- 3 Hz) 60 Hz (+/- 3 Hz) 60 Hz (+/- 3 Hz)
Outlet quantity / type: Includes 1 NEMA 5-15R Includes 2 NEMA 5-15R Includes 3 NEMA 5-15R
output receptacle output receptacles output receptacles
Overload protection: Via 20A automotive input Via 40A automotive input Via set of 2 40A
fuse fuse automotive input fuses
INPUT
Maximum input amps / watts: Full continuous load - Full continuous load - Full continuous load -
14A at 12VDC, No load - 40A at 12V DC, No load - 64A at 12V DC, No load -
0.4A at 12VDC 0.65A at 12V DC 0.95A at 12V DC,
Shutdown - 150
microamps
Input connection type: 12VDC cigarette lighter 12V DC cigarette lighter Set of 2 DC bolt-down
input plug connection input plug connection wiring terminals
Input cord length: 3 ft. hardwire input cable, 3 ft. hardwire input cable, User supplies cabling.
16 gauge, 2 wire 16 gauge, 2 wire Minimum gauges for full
load operation: 8 (6 ft
max), Two 10 (8 ft max),
6 (10 ft max), 4 (15 ft
max).
Recommended electrical Requires 12V DC input
service: source capable of
delivering 64A for the
required duration (when
used at full capacity). For
automotive applications,
professional hardwire
installation with 80A
battery system fusing is
recommended.
BATTERY
DC system voltage: DC input operating range DC input operating range DC input operating range
10-15VDC. Alarm 10-15V DC. Alarm 10-15V DC. Alarm
sounds as voltage drops sounds as voltage drops sounds as voltage drops
to 10.5V. Auto-shutdown to 10.5V. Auto-shutdown to 10.5V. Auto-shutdown
occurs at 10V. occurs at 10V. occurs at 10V.
LEDS ALARMS &
SWITCHES
Front panel LEDs:
Alarms: Dual function alarm Dual function alarm Dual function alarm
indicates overload indicates overload indicates overload
conditions or low DC conditions or low DC conditions or low DC
input voltage of 10.5V or input voltage of 10.5V or input voltage of 10.5V or
less. less. less.
Switches: Lighted on/off power Lighted on/off power Lighted on/off power
switch switch switch
PHYSICAL
Shipping weight (lbs): 1.3 2.3 3
Shipping weight (kg): 0.59 1.04 1.4
Unit weight (lbs): 1.2 2.2 2.5
Unit weight (kg): 0.54 0.99 1.1
Unit Dimensions (HWD/in): 1.75 x 3.75 x 5.75 2 x 4.25 x 7 2.75 x 5 x 8.25
Unit Dimensions (HWD/cm): 4.45x 9.5 x 14.6 5 x 10.8 x 17.8 7 x 12.7 x 21
Shipping Dimensions 8 x 5 x 1.65 11.5 x 7.3 x 2.2 4 x 6.5 x 10.25
(HWD/in):
Shipping Dimensions 20.3 x 12.7 x 4.2 29.2 x 18.54 x 5.59 10.2 x 16.5 x 26
(HWD/cm):
Material of construction: Aluminum / sheet metal Aluminum / sheet metal Aluminum / sheet metal
Cooling method: Convection Fan Fan
Form factors supported:
ENVIRONMENTAL
Operating Temperature: 32-104 Fahrenheit / 0-40 32-104 Fahrenheit / 0-40 32-104 Fahrenheit / 0-40
Celcius Celcius Celcius
Relative Humidity: 0-95% non-condensing 0-95% non-condensing 0-95% non-condensing
WARRANTY
Product warranty: 1 year (Outside the U.S. 1 year (Outside the U.S. 1 year (Outside the U.S.
and Canada, call for and Canada, call for and Canada, call for
warranty information) warranty information) warranty information)
SPECIAL FEATURES
TVSS grounding:
Appearance: Attractive, rugged, Attractive, rugged, Attractive, rugged,
metallic red color inverter metallic blue color metallic gray color
system inverter system inverter system
Load Sensing:
TRIPLITE MODEL --> PV150 PV375 PV600
POWER INVERTER MAIN
BOAT GEAR
HOME PAGE
PV1000HF PV1800HF PV3000HF
Compact 12 volt DC to Compact 12 volt DC to Compact 12 volt DC to
120 volt AC power 120 volt AC power 120 volt AC power
inverter. 1000 watts inverter. 1800 watts inverter. 3000 watts
continuous / 2000 watts continuous / 3000 watts continuous / 6000 watts
peak. Requires hardwire peak. Requires hardwire peak. Requires hardwire
DC installation, 4 AC DC installation, 3 AC DC installation, 4 AC
outlets outlets outlets. Includes corded
remote power control
module.
Compatible with 12VDC Compatible with 12VDC Compatible with 12VDC
automotive or battery automotive or battery automotive or battery
power sources power sources power sources
60 Hz 60 Hz 60 Hz
$249.99 $399.99 $699.99
1000 watts continuous, 1800 watts continuous, 3000 watts continuous,
supports instantaneous supports peak output up supports peak output up
peak output up to 2000 to 3600 watts for up to to 6000 watts for up to
watts 500 milliseconds 500 milliseconds
120V nominal 120V nominal 120V nominal
Maintains PWM sine Maintains PWM sine Maintains PWM sine
wave output voltage of wave output voltage of wave output voltage of
115 VAC (+/- 8 VAC) 115 VAC (+/- 8 VAC) 115 VAC (+/- 8 VAC)
60 Hz (+/- 3 Hz) 60 Hz (+/- 3 Hz) 60 Hz (+/- 3 Hz)
Includes 4 NEMA 5-15R Includes 3 NEMA 5-15R Includes 4 AC outlets (2
output receptacles output receptacles NEMA 5-15R and 2
NEMA 5-20R)
Automatic overload Automatic overload Automatic overload
protection shuts down protection shuts down protection shuts down
inverter system in the inverter system in the inverter system in the
event of overloads. event of overloads. event of overloads.
Inverter and electrical Inverter and electrical Output is protected by 2
system are further system are further built-in 20A circuit
protected via four internal protected via set of 6 breakers (each
40A automotive fuses 40A automotive input controlling power to 2
fuses. outlets). Inverter and
electrical system are
further protected via set
of 6 40A automotive
input fuses.
Full continuous load - Full continuous load - Full continuous load -
100A at 12V DC, No load 200A at 12VDC, No load - 286A at 12VDC, No load -
- 1.5A at 12V DC, 2.7A at 12VDC, 1.5A at 12VDC,
Shutdown / load sense Shutdown Shutdown / load sense
mode - 100 microamps mode - less than 100
microamps
Set of 2 DC bolt-down Set of 2 DC bolt-down DC INPUT: Set of 4 DC
wiring terminals wiring terminals bolt-down terminals (2
red / 2 black). AC INPUT:
hardwire
User supplies cabling. User supplies cabling. User supplies cabling.
Minimum gauges for full Minimum gauges for full Minimum gauges for full
load operation: 4 (12 ft load operation: 0 (16 ft load operation: 0 (10 ft
max), 2 (20 ft max), 0 (31 max), 00 or 2/0 (20 ft max), 00 or 2/0 (13 ft
ft max). max) max), Twin 00 using 4
conductors (26 ft)
Requires 12V DC input Requires 12VDC input Requires 12VDC input
source capable of source capable of source capable of
delivering 100A for the delivering 200A for the delivering 286A for the
required duration (when required duration (when required duration (when
used at full capacity). For used at full capacity). For used at full capacity). For
automotive applications, automotive applications, automotive applications,
professional hardwire professional hardwire professional hardwire
installation with 175A installation with 250A installation with 500A
battery system fusing is battery system fusing is battery system fusing is
recommended. recommended. recommended.
DC input operating range DC input operating range DC input operating range
10-15VDC. Alarm 10-15VDC. Alarm 10-15VDC. Alarm
sounds as voltage drops sounds as voltage drops sounds as voltage drops
to 10.5V. Auto-shutdown to 10.5V. Auto-shutdown to 10.5V. Auto-shutdown
occurs at 10V. occurs at 10V. occurs at 10V.
Set of 6 LEDs offer Dual function alarm Set of 6 LEDs offer
continuous status indicates overload continuous status
information on battery conditions or low DC information on load
and connected load input voltage of 10.5V or percentage (5 levels
conditions less. reported) and battery
charge level (7 levels
reported). See manual
for sequences.
Dual function alarm Dual function alarm
indicates overload indicates overload
conditions or low DC conditions or low DC
input voltage of 10.5V or input voltage of 10.5V or
less. less.
3 position rocker switch 3 position rocker switch
enables on/off power enables on/off power
control, plus "remote" control, plus "remote"
setting which enables setting which enables
inverter to be remotely inverter to be remotely
powered on or off when powered on or off when
used in conjunction with used in conjunction with
APSRM4 Remote included APSRM2
Control Module (sold module.
separately)
5.6 9.2 13.7
2.5 4.17 6.2
5 7.4 12.2
2.1 3.36 5.5
3.75 x 6 x 12.5 4 x 10 x 10.5 4.1 x 11.1 x 14
9.5 x 15.2 x 31.8 10.2 x 25.4 x 26.7 10.4 x 28.2 x 35.6
4 x 6.5 x 13 4.5 x 12 x 12 4.3 x 12.5 x 14.8
10.2 x 16.5 x 33 11.4 x 30.5 x 30.5 10.9 x 31.8 x 37.6
Aluminum / sheet metal Aluminum / sheet metal Aluminum / sheet metal
Fan Fan Fan
Mounting slots enable Mounting slots enable Mounting slots enable
permanent placement of permanent placement of permanent placement of
inverter on any horizontal inverter on any horizontal inverter on any horizontal
surface (see manual for surface (see manual for surface (see manual for
additional mounting additional mounting additional mounting
information) information) information)
32-104 Fahrenheit / 0-40 32-104 Fahrenheit / 0-40 32-104 Fahrenheit / 0-40
Celcius Celcius Celcius
0-95% non-condensing 0-95% non-condensing 0-95% non-condensing
1 year (Outside the U.S. 1 year (Outside the U.S. 1 year (Outside the U.S.
and Canada, call for and Canada, call for and Canada, call for
warranty information) warranty information) warranty information)
Grounding lug grounds Grounding lug grounds Grounding lug grounds
the inverter to vehicle or the inverter to vehicle or the inverter to vehicle or
earth ground - user earth ground - user earth ground - user
supplies cabling supplies cabling supplies cabling
Attractive, rugged, Attractive, rugged, Attractive, rugged,
metallic gray color metallic gray color metallic gray color
inverter system inverter system inverter system
Optional load sense Optional load sense
function conserves function enables
battery power by setting automatic inverter shutoff
the load-level at which and startup as connected
the inverter automatically equipment is powered off
shuts off. and on. Front panel load
sense potentiometer can
be set to shutoff or turn
on inverter power in
response to loads of any
level, up to 150 watts.
PV1000HF PV1800HF PV3000HF