Heat Pump HSPF and SEER Tradeoff and Deemed Savings Calculator

The purpose of this calculator is to permit the user to determine alternative combinations of air source he

pump heating and cooling system efficiencies that produce equivalent annual savings to a system with a

minimum HSFP 8.0 and SEER 13 for site built homes and HSPF 8.0 and SEER 12 for manufactured ("H

Code") homes. The user is required to supply the heating and cooling climate zone where the system will

installed, the building type in which it will be installed and the proposed units ARI certified HSPF and SEE

user must also indicate whether the duct system has been or will be sealed to PTCS or equivalent standa

This calculator may also be used to determine the Conservation and Renewable Resources Rate Credit f

source heat pumps that do not qualify as "deemed" savings, but which are considered to produce savings

beyond current codes and practices. INPUT DESCRIPTION

Enter Building Type Post-1992 Single Family Construction Non-Super Good



Enter Cooling Zone Zone 2 - 300 -



Enter Heating Zone Zone 3 - Grea



Is or will the heat pump's duct system be PTCS (or equivalent) certified?

Proposed Case System Efficiency

Enter Heat Pump HSPF (Minimum = 7.2)

Enter Heat Pump Cooling SEER (Minimum = 10)

Enter Existing Building's Heating System Type Air Source Heat Pump

Reference Case Performance

Post-1992 Single Family Construction

Reference Case Heating and Cooling Loads

Space Heating Load (kWh/yr)

Space Cooling Load (kWh/yr)

Reference Case System Efficiency

Heating (HSPF)

Cooling (SEER)

Reference Case Duct System Efficiency - Heating

Reference Case Duct System Efficiency - Cooling

Reference Case Annual Energy Use

Space Heating Use (kWh/yr)

Space Cooling Use (kWh/yr)

Total Annual Space Conditioning Use (kWh/yr)

Proposed Case Performance

Post-1992 Single Family Construction

Proposed Case Annual Energy Use

Space Heating Use (kWh/yr)

Space Cooling Use (kWh/yr)

Total Annual Space Conditioning Use (kWh/yr)

Tradeoff Accepted to Qualify As "Deemed"?

Conservation and Renewable Resource Rate Credit Calculation

Reference Case Annual Savings

Space Heating Savings (kWh/yr)

Space Cooling Savings (kWh/yr)

Total Space Conditioning Savings

Reference Case Conservation and Renewable Discount Rate Credit

Proposed Case Annual Savings

Space Heating Savings (kWh/yr)

Space Heating Savings Adjusted for Non-Equivalent HSPF Tradeoff (kWh/yr)

Space Cooling Savings (kWh/yr)

Space Cooing Savings Adjusted for Non-Equivalent SEER Tradeoff (kWh/yr)

Total Annual Space Conditioning Savings (kWh/yr)

Proposed Case Conservation and Renewable Discount Rate Credit

Calculator

tions of air source heat

gs to a system with a

or manufactured ("HUD

where the system will be

rtified HSPF and SEER. The

S or equivalent standards.

sources Rate Credit for air

ed to produce savings `

VALUE

ly Construction Non-Super Good Cents

Zone 2 - 300 - 600 CDD

Zone 3 - Greater than 7500 HDD



No





8

12

at Pump









16,594

2,726



8.0

13.0

86%

82%



9,606

922

10,528









9,606

999

10,605

No

n



1,067 8,521 (7,454)

168

1,235

$ 402



1,067

1,067

91

45

1,113

$ 351

U V W X Y Z AA AB AC AD AE AF AG AH AI AJ AK AL

1 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37

2 Base Case HP COP Base Case CAC COP Reference Case w/oPTCS Reference Case w/oPTCS Reference Case w/PTCS Reference Case w/PTCS

3 Heat Pump CAC Heat Pump COP CAC COP Heat Pump COP CAC COP

4 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3

5 2.0 2.0 1.8 3.1 3.1 3.1 2.2 2.2 2.0 3.3 3.3 3.3 2.3 2.3 2.1 3.5 3.5 3.5

6 2.0 2.0 1.8 3.1 3.1 3.1 2.2 2.2 2.0 3.3 3.3 3.3 2.3 2.3 2.1 3.5 3.5 3.5

7 2.0 2.0 1.8 3.1 3.1 3.1 2.2 2.2 2.0 3.3 3.3 3.3 2.3 2.3 2.1 3.5 3.5 3.5

8 2.0 2.0 1.8 3.1 3.1 3.1 2.2 2.2 2.0 3.6 3.6 3.6 2.3 2.3 2.1 3.8 3.8 3.8

9 2.0 2.0 1.8 3.1 3.1 3.1 2.2 2.2 2.0 3.6 3.6 3.6 2.3 2.3 2.1 3.8 3.8 3.8

10 2.0 2.0 1.8 3.1 3.1 3.1 2.2 2.2 2.0 3.6 3.6 3.6 2.3 2.3 2.1 3.8 3.8 3.8


Related docs
Other docs by HC111123003418
IL SENSO DEL NON SENSO
Views: 2  |  Downloads: 0
Quel est le mode d'action des savons ?
Views: 15  |  Downloads: 0
Slide 1
Views: 1  |  Downloads: 0
Higher Unit 2
Views: 2  |  Downloads: 0
No Slide Title
Views: 9  |  Downloads: 0
Ericsson_for_sale
Views: 139  |  Downloads: 0
Current price mac
Views: 16  |  Downloads: 0
MEDICINES AUTHORITY
Views: 3  |  Downloads: 0
Yhdistykset
Views: 0  |  Downloads: 0
By registering with docstoc.com you agree to our
privacy policy

You are almost ready to download!

You are almost ready to download!