Weep Box Installation instruction

for

1/2" and 3/4" steambeads.









The STEAMIST Weep Box comes to you ready for installation, a clear lucite shield designed to defuse steam as

it discharges into your,bathing area, eliminating the possiblity of hot spots. Translucent to match any surround-

ing; durable and easy to install in new and existing bathing areas.



I. Installation

A. New - For installation of the Weep Box in a new bath area.

1) The threaded steam pipe must be exposed 3/4" in most installations, see figure 1, this will

allow for the added thickness of the Weep Box.

IMPORTANT: When installing the Weep Box with a 1/2" Brass Steamhead and Escutcheon Plate the

threaded steam pipe must be exposed 1-3/16" from the wall. See figure 1.









2) Be sure the steam pipe is installed at the proper length from the wall.





3) Place Weep Box first onto steam pipe then the Escutcheon Plate. See figure 2. Screw the

steamhead onto the steam pipe until it begins to touch the Escutcheon, allowing it to spin

freely. The steamhead must have the steam outlet opening facing down. Care should be taken

to protect the steamhead from being scratched or marred during installation.





4) A slot is provided in the underside of the Weep Box to allow a screwdriver access for tighten

ing the securing screw in the underside of the escutcheon, this will dead end at the collar of

the steamhead. Be sure the securing screw is facing down in order notto be visible.





Pub. No. 518

B. EXISTING - When installing the Weep Box in an existing bath area.



1) Remove steamhead and escutcheon by first loosening the escutcheon securing screw, then

remove the steamhead and escutheon plate.

NOTE: Care must be taken when removing and installing the steamhead from being scratched or

marred.

2) Refer to figure 1 and determine from the illustration if steam pipe extends far enough from

the wall. If not pipe length must be changed appropriately.



3) After proper length is achieved follow steps 3 and 4 from Section A.









II. Removal



1) To remove the Weep Box, locate and loosen the securing screw in the underside of the

escutcheon.



2) Check for enough play between the Weep Box and steamhead to allow removal.



3) Lift Weep Box to where it will clear the escutcheon and pull forward. The large cutout on the

back of the Weep Box will pass over the escutcheon.



4) To replace, reverse previous procedure.

III. Cleaning.

A mild soap may be used or any dish detergent that does not have abrasives. Weekly cleaning will

keep the STEAMIST Weep Box looking like new for many years.



Other docs by qinmei liao
Arrival RSE Financial Year
Views: 0  |  Downloads: 0
Take chill pill Workshop GO KART RACING
Views: 0  |  Downloads: 0
Abe cough with sputum
Views: 2  |  Downloads: 0
SDPI Healthy Heart Project
Views: 2  |  Downloads: 0
Alternative Trade Adjustment Assistance ATAA
Views: 0  |  Downloads: 0
Improving the Bjorken estimate PHENIX
Views: 0  |  Downloads: 0
Teacher Erase Color Rhyme
Views: 1  |  Downloads: 0
Estimates of District Domestic Product
Views: 4  |  Downloads: 0
By registering with docstoc.com you agree to our
privacy policy

You are almost ready to download!

You are almost ready to download!