2010 20Accepted 20abstracts 2010MAY10 by RAC8n8Ad

VIEWS: 13 PAGES: 91

									                                                                    2010 Emerson Global Users Exchange
                                                                            Sessions by Track



                                        Session
    Type                        Track                                         Title                                                                     Abstract
                                           ID
Workshop   Asset Optimization               9     Asset Optimization and Instrument Maintenance Strategies
                                                  Development
Workshop   Asset Optimization             18      Asset Management: Leveraging your technology dollars to    Spending capital dollars to save O&M dollars has become an industry obsession and
                                                  save O&M                                                   technology provides the tool to make this happen. Technology is the master enabler to
                                                                                                             reduce labor costs, improve plant availability, increase GMWe output, improve heat rate and
                                                                                                             other efficiencies, reduce pollution and extend plant life. This paper will provide a case study
                                                                                                             that builds an asset management system from the CSI vibration monitor and Rosemount
                                                                                                             transmitter to the latest Ovation powered DCS, with all of the tools that can and should be
                                                                                                             used to get the most out of your technology investment.
Workshop   Asset Optimization             35      A Power Plant's Ten Year AMS Saga: Transition to Online    This session will look at the challenges faced in going to an on-line AMS Device Manager
                                                  AMS Device Manager from a Stand-alone Laptop to            and examine how We Energies was able to make it successful at the Valley Power Plant in
                                                  Multiplexers to the Ovation Interface                      downtown Milwaukee , Wisconsin . Part of the story has been told in the October, 2007
                                                                                                             issue of Power Engineering magazine in an article entitled "Smart Technologies Sustain
                                                                                                             Plant Reliability, Help Control Costs." Now hear the rest of the story.

Workshop   Asset Optimization             66      Getting the most out of your AMS Device Manager system     Presentation on how LyondellBasell, Clinton IA, leverages its AMS Device Manager system
                                                  and smart devices                                          & smart devices to provide the most benefit, & the synergies created by using both
                                                                                                             technologies to their potential. It will cover plant system architecture, snap-on applications,
                                                                                                             devices & diagnostic revisions utilized at the plant. Predictive/preventative benefits,
                                                                                                             troubleshooting/reactive benefits, & documentation/specification benefits along with
                                                                                                             operational benefits seen. It will also cover the importance of a system owner & roles of the
                                                                                                             owner along with the instrument techs & associated work flows.
Workshop   Asset Optimization             103     Urban Power in New York City                               New York City faces an imminent electricity supply shortfall due to steady demand growth,
                                                                                                             the anticipated retirement of existing power generation capacity, and difficulty expanding the
                                                                                                             existing local in-city power plants. This need has enabled the implementation of a small-
                                                                                                             scale (<10MW) cogeneration technology known as combined heat and power (CHP)
                                                                                                             systems. Emerson was chosen by Endurant Energy, a leading CHP energy consultant with
                                                                                                             experience in providing a master energy plan to provide Emerson equipment for the
                                                                                                             marquee property in NYC known as One Penn Plaza.

Workshop   Asset Optimization             119     AMS Restoration: Techniques, Tips & Tricks                 Our presentation will discuss the steps necessary to determine what was attached to AMS;
                                                                                                             some techniques for finding all of the HART devices; lessons learned from restoring the
                                                                                                             structure of the database andthe Calibration Management functionality; and techniques for
                                                                                                             linking site documentation such as P&ID's, loop sheets, spec sheets and equipment
                                                                                                             manuals to each tag to make AMS the single point of focus for instrument information.

Workshop   Asset Optimization             151     Remote Assistance – Expertise There When You Need It
                                                                                                               Ever had one of those days? Turbine start-up not going as planned? Commissioning a new
                                                                                                             machine and you really don't understand what the vibration data is telling you? Technology
                                                                                                             improvements have made remote machinery diagnostics much easier and faster. No more
                                                                                                             wating for your 'expert' to get on a plane and travel to your site, costing you both time and
                                                                                                             money. This paper will examine three cases in which the machinery health professional was
                                                                                                             in his office thousands of miles from the machinery.
Workshop   Asset Optimization             164     Italian power plant, Centro Energia Teverola, increase     Emerson Process Management's AMS Suite: Equipment Performance Monitor is helping
                                                  efficiency by more than 1 percent                          Centro Energia Teverola S.p.a. improve the efficiency of its 150-MW combined cycle
                                                                                                             cogeneration power plant in Teverola, Italy. Using this combination of software and services
                                                                                                             has enabled Centro Energia Teverola to optimize their maintenance strategy for inlet filters
                                                                                                             on the gas turbines, contributing to an overall efficiency improvement of 1%.

Workshop   Asset Optimization             211     AMS Device Manager - The Best of What's to Come - v11      AMS Device Manager v11 provides support for all of the new hardware options introduced
                                                  and Beyond                                                 with DeltaV 11.3 plus support for PROFIBUS DP devices. This session will cover a brief
                                                                                                             review of what this means with v11 and then get into detailon the features planned for the
                                                                                                             next releases of AMS Device Manager in 2011.




                                                                                 Page 1 of 91                                                                                             (Rev. 051010)
                                                                        2010 Emerson Global Users Exchange
                                                                                Sessions by Track



                                            Session
     Type                           Track                                          Title                                                                         Abstract
                                               ID
Workshop       Asset Optimization             221     It takes a Big Tool Box to Keep Critical Plant Assets Available This session is for individuals who want to benefit from incorporating AMS Device Manager
                                                      – Our Main Tools are AMS Device Manger and ValveLink            and AMS ValveLink Snap-on into their plant in a way that will impact their maintenance &
                                                                                                                      reliability efforts. Techniques used to ensure critical asset availability to production when
                                                                                                                      needed, instead of being compromised by day-to-day damage control will be outlined.
                                                                                                                      Methodology will be shared pertaining to the use of these major tools in our ongoing asset
                                                                                                                      optimization program initiatives at Monsanto's Muscatine facility.

Workshop       Asset Optimization             241     The Reliability Process at Sipchem                              Operating Sipchem'sJAC complex requireda changein focus from building a plant,
                                                                                                                      tosafe,production operations. This workshop will discuss how Sipchem built their Reliability
                                                                                                                      program, the process of Asset Ranking, Maintenance Task Development, and the
                                                                                                                      CMMSinterfaceinthe quest for World-Class Reliability.
Short Course   Asset Optimization             352     Enabling and Ensuring Value From Your Predictive                Are your predictive technologies delivering their full value? Learn how PlantWeb Services
                                                      Technology Investment                                           uses a structured approach on your predictive maintenance program to improve your plants
                                                                                                                      bottom line. PlantWeb Services adds value at any stage of a plant's life cycle by optimizing
                                                                                                                      and integrating predictive technologies into a re-engineered maintenance work process to
                                                                                                                      improve manpower efficiency, helping companies to become best cost producers.

Workshop       Asset Optimization             364     Using Human Centered Design to Improve Productivity with        Human Centered Design (HCD) has been used effectively with AMS Suite to implement
                                                      Handheld Configuration Devices                                  "Device Dashboards". These new dashboards provide, in one glance, a clear view of
                                                                                                                      everything users need to evaluate, diagnose, and configure a field device. This paper will
                                                                                                                      explore how the same productivity benefits achieved with PC based Device Dashboards can
                                                                                                                      be realized with a handheld communicator. Numerous examples will be demonstrated using
                                                                                                                      the 475 Field Communicator showing how productivity can be improved in the field using a
                                                                                                                      handheld with a new User Interface based on the human centered design.

Workshop       Asset Optimization             378     Implementing and managing a secure WirelessHART                 Process industries are buzzing with talk of WirelessHART device networks and the promise
                                                      network with AMS Suite                                          of these networkd to provide significant benefits to users. Experience shows your can
                                                                                                                      improve energy efficiency, improve environmental compliance, increase unit capacity, and
                                                                                                                      increase plant reliability. Learn about the tips, tricks, methods, tools and how those in the
                                                                                                                      process industries who have ensured their WirelessHART network's success

Workshop       Asset Optimization             392     Setup of Devices, DeltaV and AMS Device Manager to              Using Emerson Instruments with the DeltaV control system and AMS Device Manager gives
                                                      realize the full benefits of PlantWeb Alerts                    a user the opportunity to fully utilize the benefits of the PlantWeb digital architecture. This
                                                                                                                      workshop will give users a better understanding on how to set up the architecture in their
                                                                                                                      plant.
Workshop       Asset Optimization             394     Architecting Your AMS Device Manager System to Maximize         AMS Device Manager supports many architecture options. This course will review all the
                                                      All the Functionality You Need                                  supported architectures available using AMS Device Manager with DeltaV. In addition, we
                                                                                                                      will cover architectures with other I/O solutions such as Multiplexers and HSE gateways.
                                                                                                                      Finally, we will address the things to be considered when designing your network to achieve
                                                                                                                      optimal performance.
Workshop       Asset Optimization             435     How an existing Meridium customer utilizes AMS Suite data       The unique relationship between Emerson and Meridium created a new version of AMS
                                                      to create a complete picture of asset health.                   Asset Portal that Super Octanos utilizes to link on-line asset information from the AMS Suite
                                                                                                                      into their already existing Meridium application. Now they are able to integrate the online
                                                                                                                      diagnostic information into AMS Asset Portal that was built on Meridium's Asset
                                                                                                                      Performance Management (APM) Framework, Super Octanos can utilize the pre-defined
                                                                                                                      analysis, views and reports based on AMS Suite information to get a clear picture of asset
                                                                                                                      health.
Workshop       Asset Optimization             442     PotashCorp New Brunswick division relies on AMS to save         In 2009 PotashCorp started a $1.67 billion mine expansion in New Brunswick involving: *A
                                                      money and deliver faster start-ups.                             new 2M tonne mine and a 1.2M tonne enhancement to the existing mill *Construction of a
                                                                                                                      new mine and ore concentrator *Expansion of the finishing facilities, centrifuges, drying,
                                                                                                                      screening and dust collection *A new, four circuit Compaction Plant to increase the
                                                                                                                      percentage output of granular product. *A new 30 Km pipeline The existing and new sites
                                                                                                                      will act as a fully integrated processing facility with the existing mill operating at full 0.75
                                                                                                                      million tones capacity during construction of the new facility.




                                                                                     Page 2 of 91                                                                                                  (Rev. 051010)
                                                                                         2010 Emerson Global Users Exchange
                                                                                                 Sessions by Track



                                                             Session
    Type                        Track                                                              Title                                                                  Abstract
                                                                ID
Workshop   Asset Optimization                                  444     How Profibus DP Can Open Up a Whole New World of         Asset management systems have been used to monitor the health and well being of
                                                                       Assets in AMS Device Manager                             instruments and valves. Now with the support of Profibus in AMS Device Manager v11
                                                                                                                                users can now open up to a whole new asset type, drives. This session will highlight how
                                                                                                                                AMS Device Manager can be an integral part of setting up and monitoring overall health and
                                                                                                                                well being of Control Technique drives.
Workshop   Asset Optimization                                  538     MHM integrated with Delta V for operators benefit        Braskem, one of the largest Petrochemical companies in Brazil, come up with a desirable
                                                                                                                                concept: Asset monitoring for both predictive team and operators team. Of course the
                                                                                                                                information for them shall be different, and shall be presented different: The engineers wants
                                                                                                                                to see Asset information on the MHM software and operators wants something easy: see
                                                                                                                                critical asset alarms, related with vibration analysis, in their alarm history from Delta V
                                                                                                                                control system. The predictive team adjusts the alerts for the MHM and the operators get
                                                                                                                                the same benefit in the Delta V system.
Workshop   Asset Optimization                                  541     Title: Hidden Power of Information in the AMS Database   By extracting raw data from the AMS database, engineering and operational management
                                                                                                                                information can be made available for a wide array of applications. Discussion to cover the
                                                                                                                                following: Preparing the database for extraction, Techniques for extracting data including
                                                                                                                                both the AMS query building tools and SQL queries using MS Access, and potential
                                                                                                                                applications of information made available through data reduction.
Workshop   Business Operations, Integration & Intelligence     27      CMMS Integration Using DeltaV and AMS Asset Portal 4.0   Work order entry into a Computerized Maintenance Management System (CMMS) is an
                                                                                                                                essential activity for maintaining peak operation performance and downtime minimization.
                                                                                                                                Too often, the ease of entry and use are sacrificed due to the inherent IT ownership and
                                                                                                                                deployment of the CMMS package. By leveraging the power of DeltaV and Asset Portal,
                                                                                                                                work notification requests are initiated directly from DeltaV Operate on a module basis.
                                                                                                                                Work order status is then viewed in the same context (ISA S88) with the rest of the control
                                                                                                                                system, providing operations with a "one-stop shopping" platform.

Workshop   Business Operations, Integration & Intelligence     85      OPC Connectivity Options: OPC, Xi and UA                 The DeltaV provides different options to integrate process data with the rest of the
                                                                                                                                enterprise. The OPC portfolio offers different choices for system connectivity: OPC classic,
                                                                                                                                OPC Xi and OPC UA. While all the OPC standards provide data integration, it is important
                                                                                                                                to understand the advantages offered by each option, and which architectures make the
                                                                                                                                best use of each interfaces' strengths.
Workshop   Business Operations, Integration & Intelligence     86      How to make OPC Architectures Secure                     The boundless enterprise means that control systems are more exposed then ever before.
                                                                                                                                While global connectivity adds agility and knowledge sharing for companies, it is also a
                                                                                                                                concern for security professionals. Knowing how to apply IT network security practices,
                                                                                                                                proper OPC architecture and security enabled products to create robust connectivity is vital
                                                                                                                                to ensuring the control system's integrity.
Workshop   Business Operations, Integration & Intelligence     99      Flexible Recipes to meet Unique Requirements for         Outline of Topics:
                                                                       Pharmaceutical Packaging                                   Background
                                                                                                                                  Business Case
                                                                                                                                  Problems to Solve
                                                                                                                                  Syncade Solution
                                                                                                                                  Implementation Challenges
                                                                                                                                  Operation Reusability
                                                                                                                                  Architecture
                                                                                                                                  Systems Integration
                                                                                                                                  Results

Workshop   Business Operations, Integration & Intelligence     131     SYNCADE Integration Architecture                         SYNCADE has an architecture that facilitates integration with external plant systems. This
                                                                                                                                presentation will provide examples from past projects of the features that support integrating
                                                                                                                                a SYNCADE recipe with ERP, Plant Maintenance, and LIMS systems. We will also provide a
                                                                                                                                review of the new features being introduced intoSYNCADE that will extend and enhance the
                                                                                                                                current integration capabilities.




                                                                                                     Page 3 of 91                                                                                          (Rev. 051010)
                                                                                             2010 Emerson Global Users Exchange
                                                                                                     Sessions by Track



                                                                 Session
     Type                           Track                                                              Title                                                                      Abstract
                                                                    ID
Workshop       Business Operations, Integration & Intelligence     136     Designing Reusable Objects for Syncade Recipes - A Case    This presentation will provide a case study of designing reusableobjects for SYNCADE MES
                                                                           Study                                                      recipes. Recipes for 2 sites were developed concurrently.

                                                                                                                                         Highlights include:
                                                                                                                                         -Defining Context of Reusability in terms of recipe objects
                                                                                                                                         -Pros & Cons of Different Design Approaches
                                                                                                                                         -Planning a reusable recipe object library
                                                                                                                                         -Benefits of reusable objects
                                                                                                                                         -Obstacles & issues confronted
Workshop       Business Operations, Integration & Intelligence     161     Integrated Factory Acceptance Test Approach                In today's world, operation as well as availability of the process and utility plants rely on the
                                                                                                                                       integration of automation system installed in the plant.

                                                                                                                                         With newer technology and systems put into test, operators look for easy and smooth
                                                                                                                                      operation of the automation system from a single user interface. And for this to happen, a
                                                                                                                                      well planned and executed Factory acceptance test is required.
Short Course   Business Operations, Integration & Intelligence     180     Syncade Electronic Workflow / Procedures                   This short course will address approaches to engineering electronic workflow using
                                                                                                                                      Syncade. It will address the electronic workflow issues, different approaches with benefits
                                                                                                                                      and results, and encourage interaction from the audience. The topics will include common
                                                                                                                                      engineering issues such as integration with the process control system, use and
                                                                                                                                      management of Syncade behaviors, recipe component boundaries, recipe modularity and
                                                                                                                                      standardization, and simple equipment-based recipes. Finally, general tips and lessons
                                                                                                                                      learned based on project experience will be discussed.
Workshop       Business Operations, Integration & Intelligence     186     Electronic Workflow for a Bioreactor                       BMS is currently in the commissioning stage of its new state-of-the-art facility in Devens,
                                                                                                                                      Massachusetts using DeltaV andSyncade. The project is unique because, to date, it is BMS'
                                                                                                                                      most extensive automation of workflow.         The project team learned some valuable
                                                                                                                                      lessons andmade some key technical decisions around prompting, phase boundaries and
                                                                                                                                      recipe design. This presentation will explain many of the lessons learned using the
                                                                                                                                      bioreactor area of the project as an example.
Short Course   Business Operations, Integration & Intelligence     212     Syncade Documentation Management of Change                 I. Value of electronic document control: Discuss the current situation with manual
                                                                                                                                      document control.
                                                                                                                                      II. Business process changes: Adding a document control system allows electronic
                                                                                                                                      enforcement of the business rules established
                                                                                                                                      III. Implementation Experience: Customer 1 chose a gradual approach, while customer 2
                                                                                                                                      used a big bang method. Customer three used the DIY approach
                                                                                                                                      IV. Results: Discuss the reductions in review and approval cycle time and the reduction in
                                                                                                                                      effort to process a document.
Short Course   Business Operations, Integration & Intelligence     214     Title: Beyond IO: ISA95 Level 3 and Manufacturing          Process automation is only the starting point for a well automated facility. The application of
                                                                           Operations Management                                      ISA 95 Level 3 Manufacturing Operations Management applies IT technology to planning,
                                                                                                                                      preparation,procedure execution, materials, documentation, and quality functions. In order
                                                                                                                                      to maximize manufacturing efficiency, it is necessary to go beyond the automation of
                                                                                                                                      instrumented equipment and address production, materials, and quality operations that are
                                                                                                                                      currently coordinated and tracked with paper procedures and documentation and automate
                                                                                                                                      the entire manufacturing process from order to shipment.

Workshop       Business Operations, Integration & Intelligence     246     Maintaining Historical Trending During On-Line Migration   Transfer of process continuous control and batch events historical trending, using OPC
                                                                                                                                      (OLE for Process Control), on-line during DCS migration.

                                                                                                                                        Trends and Events critical to pharmaceutical process records.

                                                                                                                                        Challenge to change OPC Server and OPC Client connections at a signal level, one at a
                                                                                                                                      time, without disruption to overall system with 15,000 signals being trended simultaneously.

Workshop       Business Operations, Integration & Intelligence     309     Technology Transfer Troubles                               Challenges for taking a potential molecular or biological entity from research and
                                                                                                                                      development to the market can seem insurmountable. We will explore some of these
                                                                                                                                      challenges, some solutions that have been implemented in industry, and strategies for
                                                                                                                                      managing the technology transfer challenges.




                                                                                                          Page 4 of 91                                                                                              (Rev. 051010)
                                                                                             2010 Emerson Global Users Exchange
                                                                                                     Sessions by Track



                                                                 Session
     Type                           Track                                                              Title                                                                         Abstract
                                                                    ID
Workshop       Business Operations, Integration & Intelligence     312     SAP to DeltaV integration using the DeltaV SOA Gateway        This paper describes how SAP Web services, the DeltaV SOA Gateway and the Microsoft
                                                                           and SAP Web services                                          .Net Framework are used to enable secure integration between standard SAP BAPIs and
                                                                                                                                         DeltaV Recipe Exchange/Campaign Manager WCF Web services. Recipes are sent from
                                                                                                                                         SAP to DeltaV, DeltaV batches are run and material consumption and operational data is
                                                                                                                                         reported back to SAP. Workflow is secured through a firewall on a configurable TCP port
                                                                                                                                         which protects the DeltaV control network from the global Lubrizol network. This solution
                                                                                                                                         was developed and implemented globally within Lubrizol and is running in three plants.

Workshop       Business Operations, Integration & Intelligence     344     Improving Plant Operating Decisions using HART                The title of this presentation may seem to be broad and unspecific - and that is deliberate.
                                                                                                                                         For when implementing a practice of monitoring device health across a fleet of refineries,
                                                                                                                                         the benefits are many and quite diverse. This presentation provides an overview of the
                                                                                                                                         types of benefits realized and describe several in detail of how this knowledge of the field
                                                                                                                                         devices has assisted operations to improve process availability and reliability.

Workshop       Business Operations, Integration & Intelligence     363     Achieving project business goals with a structured approach   Traditionally, after a project is approved, the implementation team is measuredon project
                                                                           to PlantWeb projects                                          cost andmilestones. Unlessoriginal business objectives are writtenand integrated into the
                                                                                                                                         scope of that project, the project team is often not communicated with and loses sight of
                                                                                                                                         those objectives. Most DCS projects offer a broader opportunity to leverage PlantWeb
                                                                                                                                         benefits to make sure that the business objectives and metrics that drove the approval of
                                                                                                                                         the project are carefully integrated into the project scope. This way, the customer and the
                                                                                                                                         project team gain a better understanding of what needs to be accomplished.

Workshop       Business Operations, Integration & Intelligence     481     Managing Batch Recipe Formulas with Web Services               As manufacturers continue to increase the use of batch
                                                                                                                                         automation with sophisticated recipe structures, formula management can require
                                                                                                                                         significant effort and oversight.
                                                                                                                                          Further complicating the task is the fact that users responsible for
                                                                                                                                         managing formulas may not have direct access to the automation systems. As a result, the
                                                                                                                                         workflow associated with
                                                                                                                                         updating batch recipe formulas can be cumbersome and labor intensive.

                                                                                                                                          This session discusses the use of DeltaV Recipe Exchange to provide remote formula
                                                                                                                                         access to authorized users, thus streamlining workflow in a batch process facility.

Workshop       Business Operations, Integration & Intelligence     483     OPC Xi Simplifies Client Access to DeltaV                     OPC has released a new interface aimed at migrating existing OPC servers from
                                                                                                                                         COM/DCOM to .NET. .NET is Microsoft's new software environment designed specifically
                                                                                                                                         to support secure computing in the Internet world. This new OPC interface has been named
                                                                                                                                         Express Interface (Xi) to reflect its primary objectives of ease of use and implementation,
                                                                                                                                         including simplified configuration through the use of auto-discovery mechanisms. Xi also
                                                                                                                                         makes access through firewalls easy, while providing additional security mechanisms to
                                                                                                                                         better protect against external access threats.
Short Course   Business Operations, Integration & Intelligence     491     Managing Electronic Logs and Equipment Status with            Transitioning from Paper to Electronic for Equipment Logs and SOPS. This course will
                                                                           Syncade ET                                                    provide ideas of where the Syncade ET Module can help to make the transition from a paper
                                                                                                                                         world to electronic on the operational plant.TheETmodule is not for Equipment Tracking but
                                                                                                                                         can help to replace othercurrent paper logbookson the operation floor such as clean rooms
                                                                                                                                         or shift logs.With ET 4.3, SOPS can now be managed with workflows that are generated by
                                                                                                                                         activities logged in ET.
Workshop       Business Operations, Integration & Intelligence     525     EBR in Biotech Formulation, Fill Finish & Packaging           Bristol-Myers Squibb's Manati Puerto Rico has recently implemented electronic batch
                                                                           Applications                                                  records for formulation, Fill Finish, and Packaging applications for biotech products using the
                                                                                                                                         Syncade Smart Operations Management Suite. Syncade is used for solutions for
                                                                                                                                         formulation, vial filling, syringe filling, lyophilization, and packaging. This paper reviews the
                                                                                                                                         scope of the Syncade implementation and the business objectives achieved




                                                                                                         Page 5 of 91                                                                                                 (Rev. 051010)
                                                                                             2010 Emerson Global Users Exchange
                                                                                                     Sessions by Track



                                                                 Session
     Type                           Track                                                              Title                                                                        Abstract
                                                                    ID
Workshop       Business Operations, Integration & Intelligence     540     Simple and Flexible Work Flows to Replace Paper Logs          At facilities operating under a QMS or GMP, there are a range of logs that track the status of
                                                                                                                                         equipment. Although electronic process recipes can handle equipment events during
                                                                                                                                         manufacturing, stand alone equipment recipes are unique in the following ways: (1)
                                                                                                                                         equipment activities are not always associated with a process recipe, (2) equipment
                                                                                                                                         instructions can be very simple with little need for an S88 hierarchy, and (3) since many
                                                                                                                                         equipment recipes are completed with no exceptions, periodic review by exception focuses
                                                                                                                                         on only those recipes where an exception occurred.
Workshop       Business Operations, Integration & Intelligence     543     Managing the Transition from Paper to Syncade Electronic      At a newfacility orwheninstalling a newproduction line, theElectronic Batch Record (eBR)
                                                                           Records in an Operating Facility                              systemcan be commissioned along with the new construction. However, at an operating
                                                                                                                                         plant, rolling out an eBR without interrupting production posses major challenges. Lonza
                                                                                                                                         Biologicsin Portsmouth, NH elected to roll out eBR in two phases. The first phase included
                                                                                                                                         all Syncade functionality and modules including an SAP interface as required to support
                                                                                                                                         dispensing and the second phase involved the implementation of electronic batch records
                                                                                                                                         on a case by case basis for individual products.

Workshop       Business Operations, Integration & Intelligence     563     Commercial and Technical Benefits Through Early MAC         This paper presents commercial and technical FEED/EPC project and client benefits from
                                                                           Supplier Selection for World Class Grassroots Ammonia Plant early MAC/MIV Supplier selection using KBR strategies of ISSP and CII PEpC strategic
                                                                                                                                       supply. Additional Integrated Technology leveraging was used including AMS and Emerson
                                                                                                                                       continuous Field device diagnostics to aid in installation, commissioning and start-up, plus
                                                                                                                                       ongoing superior plant performance. KBR World Leader Ammonia process technologies
                                                                                                                                       drove the project success in tandem with responsive and unique Emerson PlantWeb and
                                                                                                                                       AMS proven capabilities, thru the clarity and power of DeltaV and FF.

Short Course   Control System Modernization                        19      Online Upgrade from v6.3.4 to v10.3.1                         Emerson Calgary, and Emerson SureService, will be performing an online upgrade of
                                                                                                                                         EEAL's Kizomba offshore sites, in July 2010.
                                                                                                                                         Upon completion of this upgrade, I would like to share this project experience at Emerson
                                                                                                                                         Exchange. I will discuss the various technical points as listed above, the complexity of the
                                                                                                                                         project, and Emerson's approach to lowering risks to the live system. This presentation
                                                                                                                                         would serve as a foundation for all customers to contemplate their own upgrade, and the
                                                                                                                                         diverse areas needed for consideration.
Workshop       Control System Modernization                        25      Wireless Ethernet DeltaV Control Network                      Chemical producer in South Louisiana installed a Wireless Ethernet solution offered by
                                                                                                                                         Emerson Systems & Solutions.
Workshop       Control System Modernization                        62      Control sixteen motors with four Variable Speed Drives        DeltaV/DeviceNet provides a reliable method to control any one of several motors from a
                                                                           (VFDs) – How can that be? VFD Implementation on               single VFD. Reducing the number of VFD's greatly reduced the cost of implementation
                                                                           DeviceNet                                                     (especially for large motors).
                                                                                                                                          Other talking points: Wiring/installation cost reduction with DeviceNet Managing VFD
                                                                                                                                         programming configuration for multiple motor applications (i.e. logistics of reprogramming
                                                                                                                                         drives) Evaluate various bus systems for communication and control between the DeltaV
                                                                                                                                         DCS and the VFDs Load loss detection What the manuals didn't tell you

Short Course   Control System Modernization                        77      Control Loop Foundation - Batch and Continuous Processes      A new book on process control fundamentals will be published by ISA in September, 2010.
                                                                                                                                         This book is based on material originally developed for internal Emerson classes. In this
                                                                                                                                         short course the book authors present key areas of the book and demonstrate web base
                                                                                                                                         exercises that accompany the book.
Workshop       Control System Modernization                        79      Using new eye-tracking technology to measure the usability    This workshop will provide an overview of the Human Centered Design process and how
                                                                           of Control Studio as part of Human Centered Design            eye-tracking technology being researched at Texas State University is helping us evaluate
                                                                                                                                         product designs. Performing usability testing early in the design process is a key activity to
                                                                                                                                         ensure our products are easy to use and meet the needs of our customers. Learn how you
                                                                                                                                         or your plant personnel can help shape the future of Emerson's products by participating
                                                                                                                                         directly in the Human Centered Design process.
Workshop       Control System Modernization                        109     POWER AND GROUNDING: Get it right before you                  When modernizing or migrating your plant control system, existing power and grounding
                                                                           modernize and migrate your DCS system                         systems may be inadequate, compromised, noisy, or unsafe with little or no indication of
                                                                                                                                         these issues. Old control systems may appear to operate properly especially if they are
                                                                                                                                         unable to detect power or ground issues. Equipment or personnel safety may be in jeopardy.
                                                                                                                                         This workshop will discuss potential problems and corrective actions.




                                                                                                         Page 6 of 91                                                                                                (Rev. 051010)
                                                                          2010 Emerson Global Users Exchange
                                                                                  Sessions by Track



                                              Session
     Type                          Track                                            Title                                                                      Abstract
                                                 ID
Workshop       Control System Modernization     113     Using FlexConnect to migrate your legacy DCS to DeltaV       FlexConnect is a DCS migration product that allows legacy field wiring and field termination
                                                                                                                     panels to remain in place and connect field wiring with new or existing IO cables to DeltaV
                                                                                                                     IO cards. FlexConnect is sometimes called a wire stretcher.
Workshop       Control System Modernization     195     Charmed – Upgrading UT Pickle Separations to DeltaV v11      This presentation follows the modernization of the UT Pickle Research Site in Austin, TX.
                                                        with integrated CHARMS                                       The project includes an upgrade to CHARMS IO (electronic IO) and S-Series controllers,
                                                                                                                     installation of new junction boxes, upgrade of graphics, conversion to rack mounted PCs
                                                                                                                     and Servers, and modernization of the control room.
Workshop       Control System Modernization     202     Tuning in on Asphalt Viscosity Blending with Micro Motion    This paper provides an overview of a project at BP Whiting refinery to improve and
                                                        and DeltaV                                                   automate the process that produced the Certified Base Asphalt that is used to produce the
                                                                                                                     various asphalt grades required by industry for roads, roofing and other various end user
                                                                                                                     industries.
Workshop       Control System Modernization     230     How to Modernize a Large Bulk Product Terminal – Follow a    Vopak Deer Park is the largest bulk liquid terminal in the Houston ship channel. While some
                                                        Master Plan                                                  areas of the site are automated, a large portion is still operated manually with very little
                                                                                                                     instrumentation infrastructure. The site has now embarked on a multi-year automation
                                                                                                                     investment program to install new tank gauges, overfill protection, and physical
                                                                                                                     infrastructure to support a fully-automated terminal operation. Such an investment must be
                                                                                                                     carefully planned and justified.

Workshop       Control System Modernization     243     DCS Migration Results At Pharmaceutical Plant                Initial results of a multi-phase, on-line batch migration of aging DCS system to DeltaV to be
                                                                                                                     presented.
                                                                                                                         Specifically, focus will be on the WorkPackageswhich handled signal by signal move from
                                                                                                                     one DCS system to another.
                                                                                                                       Presentation will cover the Learning Objectives established with the first process
                                                                                                                     areamigrated.

                                                                                                                       Presentation will cover the technical and business results achieved.

                                                                                                                       Presentation will cover the Lessons Learned from the initial process area.
Workshop       Control System Modernization     244     Migration and Modernization – Lessons Learned, Part I        The need to improve process performance is a challenge many face. Process automation
                                                                                                                     can be a driver to improve performance, but many times is under used. DCS obsolescence
                                                                                                                     has become a reality for others. Automation system modernization is not a common event
                                                                                                                     thus most process companies do not have the expertise to plan, implement and start-up a
                                                                                                                     modernization automation system. This 2 part workshop discusses refined methods and
                                                                                                                     lessens learned from past projects. Best project pracitices, things to watch out for, risk
                                                                                                                     mitigation, and justification methods are topics that will be discussed.

Workshop       Control System Modernization     245     Migration and Modernization – Lessons Learned, Part II       The need to improve process performance is a challenge many face. Process automation
                                                                                                                     can be a driver to improve performance, but many times is under used. DCS obsolescence
                                                                                                                     has become a reality for others. Automation system modernization is not a common event
                                                                                                                     thus most process companies do not have the expertise to plan, implement and start-up a
                                                                                                                     modernization automation system. This 2 part workshop discusses refined methods and
                                                                                                                     lessens learned from past projects. Best project pracitices, things to watch out for, risk
                                                                                                                     mitigation, and justification methods are topics that will be discussed.

Short Course   Control System Modernization     304     Provox and Siemens S5 to Deltav migration during operation This short course describes a how to migrate a plant from Provox and Siemens S5 PLS
                                                                                                                   control to deltaV control partly during operation. The PLC's is kept as remote I/O by using
                                                                                                                   Profibus net. This course shows the method used in a Yara migration project. The method
                                                                                                                   gives the project flexibility to move the logic during operation or during a shot down.
                                                                                                                     This method reduces the necessary plant downtime needed by the migration project.
                                                                                                                     In some areas the production increased when DeltaV "took over" the control.




                                                                                      Page 7 of 91                                                                                             (Rev. 051010)
                                                                                2010 Emerson Global Users Exchange
                                                                                        Sessions by Track



                                                    Session
    Type                       Track                                                      Title                                                                        Abstract
                                                       ID
Workshop   Control System Modernization               406     Total Installed and Commissioned Cost Savings Using           Using Electronic Marshalling in greenfield projects or plant expansions offers many
                                                              Electronic Marshalling in Brownfield Modernization Projects   advantages over traditional wiring, such as easily accommodating late changes in a project
                                                                                                                            and the ability to assign individual I/O channels to any controller.

                                                                                                                            Electronic Marshalling can also offer significant benefits in brownfield projects where an I/O
                                                                                                                            infrastructure already exists. This presentation will show how Electronic Marshalling can be
                                                                                                                            applied to legacy system migrations and save on Total Installed and Commissioned Cost.


Workshop   Control System Modernization               426     The DeltaV Virtual Power Plant                                A power plant in the midwest needed to train new operators and qualify existing operators
                                                                                                                            without effecting the operation of the plant. Working together with the Emerson local
                                                                                                                            business partner we delivered a dynamic simulation of the power plant that allowed them to
                                                                                                                            train and qualify operator safely, off-line.
Workshop   Control System Modernization               500     Advanced Process Control gets a Ticket on the “Express”       The " DeltaV Connect" series has been used successfully as the ideal first-step in a
                                                              Train to Migration and Modernization                          long-term migration plan from legacy DCS platforms to DeltaV & PlantWeb at several
                                                                                                                            customer sites. In this paper, we show howDeltaV Connect for Honeywell was installed
                                                                                                                            because of its robustness to support a DeltaV-based Advanced Process Control (APC)
                                                                                                                            system layered onto a legacy Honeywell DCS.
Workshop   Control System Modernization               508     Three Non-conventional Level Control Applications             a) Advanced Level Control for Processes with Large Transport Delay (Allen-Bradley PLC5).
                                                                                                                            Modified Smith Predictor used to control level in a manufacturing facility.

                                                                                                                            b) Copper Mine Concentrator Plant Water Management System (Modicon Quantum PLC).
                                                                                                                            During the system upgrade a very convoluted and ineffective water management system
                                                                                                                            control code was replaces with a compact algorithm.

                                                                                                                            c) Water Injection System Surge Tank Level Control for an Oil Production Platform
                                                                                                                            (Emerson DeltaV). A challenging surge tank level control problem was solved by
                                                                                                                            conventional control tools without resorting to use of a more complex multivariable controller.

Workshop   DeltaV and Ovation System Applications     14      LEL Monitoring in Pharmaceutical Tray Dryers                  In the production of bulk pharmaceuticals, it is common to use tray dryers to drive off
                                                                                                                            solvents used to dissolve bulk products. NFPA requires flammable solvent tray dryers to
                                                                                                                            come with LEL monitors used to cut off the heat if the dryer chamber exceeds the lower
                                                                                                                            explosive limit. OEM dryers typically are supplied with catalytic bead type LEL
                                                                                                                            detectorswhich onlylast about one week inside the dryer chamber before needing calibration.
                                                                                                                            This paper documents how Delta V and an IR style LEL detector was used to monitor LEL in
                                                                                                                            pharmaceutical tray dryer.
Workshop   DeltaV and Ovation System Applications     28      Guardian for the Average User                                 Guardian Support is a prognostic service designed to optimize the availability, sustainability,
                                                                                                                            and performance of your DeltaV system. But who really has the time to manage all the
                                                                                                                            information that Guardian provides you with? This workshop will focus on how to get the
                                                                                                                            most use from Guardian in the least amount of your valuable time.
Workshop   DeltaV and Ovation System Applications     42      Faux meters – When real instrumentation just isn’t good       One of the key factors to good control system performance is correctly specified field
                                                              enough                                                        instrumentation, But what options are available to the control engineer when instrumentation
                                                                                                                            doesn't perform as needed and immediate replacement is not an option? Come see one
                                                                                                                            innovative solution to this type of dilemma and the underlying principles for developing
                                                                                                                            similar solutions in your plant. Faux meters could very well make you real dollars!

Workshop   DeltaV and Ovation System Applications     43      Batch Executive crash recovery for DeltaV 10.3 and below
                                                                                                                              ISA88 created models to understand the real world of controls, equipment, processes, and
                                                                                                                            information management. Since engineering can be creative as everyone seeks a better
                                                                                                                            way, the trick is to be flexible enough in the models to allow distress situation and upgrades
                                                                                                                            with less effort.As DeltaVprovides flexibility in control system architecture, it also has a
                                                                                                                            potential of single point of failure, for million $$$ product and that is Batch Executive .




                                                                                               Page 8 of 91                                                                                             (Rev. 051010)
                                                                                2010 Emerson Global Users Exchange
                                                                                        Sessions by Track



                                                    Session
    Type                       Track                                                      Title                                                                       Abstract
                                                       ID
Workshop   DeltaV and Ovation System Applications      52     Remote Video with DeltaV                                     Video surveillance is becoming an indispensable part of process plant safety, security and
                                                                                                                           operations. Mission-critical video feeds can now be delivered to the control room, office
                                                                                                                           buildings and other areas in the plant in a highly flexible way. Using an ActiveX control and a
                                                                                                                           software-based camera management system, live video feeds and camera controls can be
                                                                                                                           embedded into a DeltaV Operate interface. The benefits of having a live video feed
                                                                                                                           embedded within an operator display are many and include safety, security and productivity.

Workshop   DeltaV and Ovation System Applications     54      DeltaV Alarm Paging Using OPC and GPRS Modem                 The BMS pilot plants have multiple DeltaV Systems. Process operations needed an
                                                                                                                           application for secure 24/7 remote notification of critical alarms. A DeltaV Alarm Paging
                                                                                                                           System was designed and implemented. The APS monitors critical alarms from DeltaV &
                                                                                                                           notifies authorized users via alarm paging system using a GPRS wireless modem. The APS
                                                                                                                           uses the DeltaV PCS with OPC,UCME(alarm paging OPC client installed on a DeltaV
                                                                                                                           Application Station), and wireless technologies. Alarms are sent to the users cellphones as
                                                                                                                           short messaging text (SMS).
Workshop   DeltaV and Ovation System Applications     101     Standard Field Junction Boxes for CHARM I/O take away        The concept of electronic marshalling with Emerson's new CHARM I/O can not only be
                                                              stress from your project                                     applied to control room installation. On the contrary CHARM I/O is also ideal as a DeltaV
                                                                                                                           remote I/O located in the plant next to sensors and actuators. Pre-engineered junction
                                                                                                                           boxes (JB), ready for installation both in hazardous and ordinary locations are available off
                                                                                                                           the shelf. Various options allow for adapting to individual customer requirements.

Workshop   DeltaV and Ovation System Applications     104     DeltaV Context Commenting – Custom Application for
                                                              Electronic Batch Review and Approval                          An R&D facility at Bristol-Myers Squibb uses DeltaV for batch execution and RtReports for
                                                                                                                           electronic batch review. Comments entered by the operator via the DeltaV are displayed in a
                                                                                                                           general section in RtReports. At review, Quality must visually map each comment to the
                                                                                                                           relevant section of the report based on context manually entered into the comment. Review
                                                                                                                           is time-consuming. To improve efficiency, BMS implemented an innovation for attaching
                                                                                                                           S88 context to the HMI submitted comments. This enables the comments to be sorted into
                                                                                                                           the appropriate report section, simplifying review.

Workshop   DeltaV and Ovation System Applications     110     DeltaV Virtualization – Real Today, A Reality Tomorrow       This presentation examines DeltaV virtualization for engineering design, simulation, testing,
                                                                                                                           training, and future on-line operation. A virtual computing platform enables running multiple
                                                                                                                           DeltaV workstations and control nodes from a common host computer, and significantly
                                                                                                                           simplifies software installation and maintenance. An overview of virtualization will be
                                                                                                                           presented followed by practical DeltaV applications available today, and future applications
                                                                                                                           of tomorrow.
Workshop   DeltaV and Ovation System Applications     117     The Dark Side - The Code Behind a Consolidated Operator      Six different facilities were combined into one DeltaV system. Each facility had things that
                                                              Interface                                                    were important to it on their DeltaV Operate Toolbar. With the consolidation, each
                                                                                                                           workstation would change its layout based on which operator logged in. Taking advantage of
                                                                                                                           a DeltaV upgrade to readdress how things worked behind the scenes, the toolbars were
                                                                                                                           combined into an A/B pair with the controls and functions based on the operator's privilege,
                                                                                                                           rather than login name. A means for swapping between virtual toolbars was also provided
                                                                                                                           for accounts that are authorized for more than one facility.
Workshop   DeltaV and Ovation System Applications     118     Guidelines for Setting Filtering and Module Execution Rate   The DeltaV system allows the user to select the module execution rate. Also, a variety of
                                                                                                                           tools are provided in DeltaV to filter the measurement used in control. To achieve best
                                                                                                                           control performance, the module execution rate and the filtering applied to the control
                                                                                                                           measurement must be set based on the process dynamics. In this workshop some
                                                                                                                           guidelines are given for setting module execution rate and filtering. Examples will be used to
                                                                                                                           show the impact of these setting.
Workshop   DeltaV and Ovation System Applications     123     Energy Efficiency and Production Optimization with           After obtaining substantial installation benefits with a PlantWeb architecture, operational
                                                              PlantWeb Digital Architecture                                savings were obtained. This allowed the architecture's expansion replacing the existing
                                                                                                                           SCADA system.




                                                                                            Page 9 of 91                                                                                               (Rev. 051010)
                                                                                    2010 Emerson Global Users Exchange
                                                                                            Sessions by Track



                                                        Session
     Type                          Track                                                      Title                                                                     Abstract
                                                           ID
Workshop       DeltaV and Ovation System Applications     132     Process Analysis Using 3D plots                            The cause and effect of changes in a temperature, pressure or composition profile across a
                                                                                                                             process unit can be difficult to analyze on-line using traditional 2D plots. A trial application
                                                                                                                             was developed to explore the benefits of using 3D plotting for on-line analysis of profile
                                                                                                                             changes. This application was installed at the UT Pickle Research Center to study changes
                                                                                                                             in the temperature profile of an absorber unit. Results from this installation will be presented
                                                                                                                             and information provided on the 3D plotting application. Also, this application will be
                                                                                                                             demonstrated.
Workshop       DeltaV and Ovation System Applications     156     Information Security and Industrial Controls Operations    As DeltaV admins become more challenged to maintain a secure system they are beginning
                                                                  Dialogue                                                   to encounter more direction and help offered by their IT security staffs. Developing
                                                                                                                             communications between the Operations group maintaining the control system and the IT
                                                                                                                             group who is concerned with system security is becoming an important aspect of managing
                                                                                                                             the control system. This workshop using a dialogue between a DeltaV operations oriented
                                                                                                                             viewpoint and an IT staff member viewpoint will help explain how we can learn to
                                                                                                                             communicate with each other to develop a security solution that will meet the needs of both
                                                                                                                             organizations.
Workshop       DeltaV and Ovation System Applications     168     DeltaV Development Systems in a Virtualized Enviroment     The power of today's servers are well beyond the demand of most DeltaV systems. The
                                                                                                                             currently shipping DeltaV rack mount server has more than enough computing power for a
                                                                                                                             development system, not just a ProPlus. Through the use of virtualization on DeltaV
                                                                                                                             development systems a significant reduction of hardware costs can be realized without
                                                                                                                             sacrificing performance. The additional ability to snap-shot the system before making
                                                                                                                             software patches allows quick recovery if a problem develops.
Workshop       DeltaV and Ovation System Applications     194     Automating Portable Skids in a Hazardous Environment       The pharmaceutical and biotech industries often face the need to automate vessels and
                                                                                                                             skids that are truly portable. While commonly done in general purpose areas, this task
                                                                                                                             becomes difficult if the area is classified as hazardous. Purge units, grounding, power
                                                                                                                             feeds, instrument air, and control signals all require special considerations if the skid is to
                                                                                                                             remain truly portable. By combining the use of intrinsic safety, quick disconnects,
                                                                                                                             specialized receptacles, carefully selected field instrumentation, fiber optics, and field
                                                                                                                             busses, these skids can be fully automated while remaining mobile.
Workshop       DeltaV and Ovation System Applications     319     DeltaV implementation using change control, cost saving    A completely new plant was built, starting with an existing set of plant P&ID drawings. The
                                                                                                                             necessary modifications, due to differences between the plants, were done under Change
                                                                                                                             Control. The DeltaV validated code from the existing plant was transferred to the new
                                                                                                                             DeltaV system. The code, not modified during the project, was accepted as validated.
                                                                                                                             Only code touched by the Change Control Process was tested.
Workshop       DeltaV and Ovation System Applications     359     A Structured Approach to Implementing PlantWeb Alerts in   Operations and Safety Users are most concerned with situations needing rapid response.
                                                                  DeltaV Systems                                             Maintenance and Process Optimization Personnel desire feedback to proactively plan
                                                                                                                             responses. Emerson's structured approach to define your PlantWeb alert strategy considers
                                                                                                                             the consequence of inaction and the response time to avoid a process or safety impact.
                                                                                                                             Emerson's structured approach to IMPLEMENT the PlantWeb Alert Strategy will develop a
                                                                                                                             predictive alert strategy to address full utilization of predictive diagnostic capabilities with
                                                                                                                             your DeltaV system and AMS Device Manager.
Short Course   DeltaV and Ovation System Applications     375     How to: DeltaV version 10 Group Policy Management          DeltaV version 10 is the first release of DeltaV to take advantage of Microsoft Active
                                                                                                                             Directory Group Policy Objects. Learn how these GPOs are applied and what tools to use to
                                                                                                                             list (and perhaps change) these policies.This is the information that IT personnel know about
                                                                                                                             and the process engineersneed a quick lesson in how to see and manipulate the same
                                                                                                                             information. (This presentation is not intended for IT savvy personnel, this is just the basics
                                                                                                                             for those that have never dealt with GPOs before).
Workshop       DeltaV and Ovation System Applications     384     Easy Integration of Machinery Protection (vibration) and   Emerson launches easy integration of machinery protection of critical mechanical equipment
                                                                  DeltaV                                                     into your DeltaV control system. When plant operators have visibility into the performance of
                                                                                                                             turbines, compressors, feed pumps and other mechanical equipment, operators can take
                                                                                                                             action before failures occur, avoiding costly plant shutdowns, equipment damage and
                                                                                                                             personnel injury. The easy integration includes an auto scan, import tools anda library of
                                                                                                                             dynamos that facilitates rapid GUI development. Using direct comparison, see how this easy
                                                                                                                             3-step process reduces integration time from days to minutes.




                                                                                                Page 10 of 91                                                                                             (Rev. 051010)
                                                                                     2010 Emerson Global Users Exchange
                                                                                             Sessions by Track



                                                        Session
     Type                          Track                                                       Title                                                                           Abstract
                                                           ID
Workshop       DeltaV and Ovation System Applications     430     Pressure-Temperature Compensation in DeltaV - The Good,          Most gas flow applications require the raw signal from the flow element to be pressure
                                                                  The Bad, and the Ugly                                            and/or temperature compensated to a well accepted condition such as standard or normal
                                                                                                                                   conditions. Although the need for pressure-temperature compensation is well known, its
                                                                                                                                   various implementations run the gambit from accurate (the good), to inaccurate (the bad), to
                                                                                                                                   very complicated (the ugly). This paper will discuss several tips and give a number of
                                                                                                                                   examples for correctly configuring DeltaV blocks such as the pre-built PT Compensation
                                                                                                                                   composite block, AGA and arithmetic blocks.
Workshop       DeltaV and Ovation System Applications     514     Environmental Stewardship is Key to District Heating in          Seattle Steam is a district heating facility providing steam and heat to approximately 200
                                                                  Seattle                                                          buildings in Seattle's Central Business District. This 115 year old company recently
                                                                                                                                   embarked on a modernization program to significantly reduce the carbon footprint of the
                                                                                                                                   plant and move forward in their goal to be an environmental leader in the Seattle community.
                                                                                                                                    The plant had produced 100% of its steam through burning natural gas. Although this is the
                                                                                                                                   "cleanest" fossil fuel available, the district felt there was an opportunity to move to renewable
                                                                                                                                   fuel that would further reduce the environmental impact of the site.

Short Course   Emerson Educational Services               26      Coriolis Installation Best Practices & Smart Meter Verification This Micro Motion short course is for anyone that is connected with the efficiency, safety
                                                                                                                                  and maintenance of any plant process and who wants to maximize profitability, uptime and
                                                                                                                                  product quality. You will learn about how to apply it to challenging applications in your plant
                                                                                                                                  such as entrained gas processes, empty full empty batching and also learn about an exciting
                                                                                                                                  new Micro Motion capability in the area of SmartMeter Verification. Each of thesetopics will
                                                                                                                                  be covered in this short course through a combination of presentation materials, live demos
                                                                                                                                  and group discussion
Short Course   Emerson Educational Services               80      Self Organizing Wireless Network Setup - Course 2375EX          This Session is for individuals that want to gain experience setting up the components of the
                                                                                                                                  EPM Self Organizing Network.
Short Course   Emerson Educational Services               154     Practical Loop Tuning using Lambda Tuning Method                Practical Loop Tuning using Lambda Tuning Method' short course is a 3-hour introduction to
                                                                                                                                  modern process control concepts that include understanding process dynamics and the use
                                                                                                                                  of non-oscillatory Lambda loop tuning methods to improve loop performance and minimize
                                                                                                                                  process variability.
Short Course   Emerson Educational Services               339     Control Valve Selection for Real, Non-Standard, or Critical     This course is recommended for individuals who specify control valves for industrial
                                                                  Process Applications                                            processes that exhibit non-standard or non-ideal behavior, or are processes critical to plant
                                                                                                                                  function. The course addresses specific process applications, from a "real behavior"
                                                                                                                                  perspective, that routinely fall outside the scope of the present day industry standards. The
                                                                                                                                  participant will learn how to: identify the correct technical context of the application; identify
                                                                                                                                  the correct data for the application context; perform preliminary valve sizing and selection;
                                                                                                                                  and account for the effects of the process piping configuration on loop control.

Short Course   Emerson Educational Services               387     Installing, Configuring, and Commissioning the DVC6200
                                                                  with ValveLink Mobile on the 375/475 Field Communicator            In this short course, students will:

                                                                                                                                     -    Understand the basics of the DVC 6200 Digital Valve Controller non-contact linkage.

                                                                                                                                    -  Describe the available arrays and mounting hardware.
                                                                                                                                    -  Acquire experience with the various applications including sliding stem, rotary window
                                                                                                                                   mounts, and rotary end mounts.
                                                                                                                                    -  Acquire experience working with ValveLink Mobile software.

Short Course   Emerson Educational Services               391     Using ValveLink Mobile for DVC Setup, Configuration, and         In this short course, students will:
                                                                  Diagnostics
                                                                                                                                    - Explain the basic roles and functions of the ValveLink Mobile application.
                                                                                                                                    - Explain steps for configuring and device pairing a Bluetooth HART modem with a
                                                                                                                                   smart phone or PDA
                                                                                                                                    - Explore the unique ValveLink interface in the Windows Mobile application
                                                                                                                                    - Configure, calibrate, tune, and diagnose a Fisher DVC using ValveLink Mobile




                                                                                                 Page 11 of 91                                                                                                   (Rev. 051010)
                                                                             2010 Emerson Global Users Exchange
                                                                                     Sessions by Track



                                                 Session
     Type                         Track                                                Title                                                                  Abstract
                                                    ID
Short Course   Emerson Educational Services        555     DeltaV S-series Electronic Marshalling                 This short course provides hands-on workshops for individuals responsible for implementing
                                                                                                                  DeltaV S-series Electronic Marshalling. The lecture will cover the hardware architecture and
                                                                                                                  configuration of the I/O subsystem. The hands-on workshops will allow students to install,
                                                                                                                  configure and test their I/O subsystem from the screw terminals to the Operator display
                                                                                                                   Topics
                                                                                                                   - Hardware Architecture - CHARM I/O card - CHARMS - Configuration - Testing

Short Course   Emerson Educational Services        556     Syncade Suite Overview                                 In this short course, students will:
                                                                                                                   - Understand how an MES system can improve productivity - Understand the Syncade
                                                                                                                  database / hardware architecture - Become familiar with the Syncade Suite of applications -
                                                                                                                  Access and use each of the Syncade applications
                                                                                                                   During the hands-on workshops, students will:
                                                                                                                   - Add documents to Document Control and Archiving (DCA) - Promote a document in DCA -
                                                                                                                   Create an order and execute a simple recipe - Add a material and create inventory -
                                                                                                                  Execute an event on a piece of equipment
Short Course   Emerson Educational Services        560     DeltaV Graphics                                        This short course provides hands-on workshops for individuals responsible for building
                                                                                                                  DeltaV graphics. The lecture will explain the use of version 11 dynamos and themes and
                                                                                                                  allow students to build and test displays using these new features. The course will also
                                                                                                                  explain the configuration settings that are available to customize the behavior of the
                                                                                                                  dynamos.
                                                                                                                   Topics
                                                                                                                   - Themes - Theme Dynamos - Configuration Settings
Short Course   Emerson Educational Services        564     Fundamentals of Vibration Analysis                     This short course is for those with no prior experience in vibration analysis. Students learn
                                                                                                                  about causes of vibration and methods of measurement. Emerson's CSI 2130 Machinery
                                                                                                                  Health Analyzer will be used to demonstrate vibration principles. Topics covered include: *
                                                                                                                  Introduction to vibration * Basic fault identification * Information to help jumpstart a vibration
                                                                                                                  program
Workshop       Emerson Product/Services Update      3      DeltaV Batch Product Update                            The current release of DeltaV includes new functionality for batch users in both the regulated
                                                                                                                  and nonregulated environments. Come and join the session to gain a detailed look at what
                                                                                                                  enhancements were made.
Workshop       Emerson Product/Services Update     31      New Product Introduction - Emerson Smart Firewall      Emerson introduces a new easy to implement perimeter firewall to help protect and secure
                                                                                                                  your DeltaV network. This firewall that will begin shipping at the end of 2010 is another
                                                                                                                  addition to our "Secure Out of the Box" initiative. This firewall will provide plug and play
                                                                                                                  functionality coupled with Human Centered Design elements for ease of setup to meet
                                                                                                                  installation specific requirements. It also supports intrusion detection and prevention with
                                                                                                                  automatic threat mitigation updates to help keep your protection up-to-date against the latest
                                                                                                                  threats.
Workshop       Emerson Product/Services Update     39      DeltaV v11 and Smart Wireless                          Emerson is leading the market in natively integrated wireless offerings. This presentation
                                                                                                                  describes four wireless solutions available with DeltaV version 11: (1) Emerson's native
                                                                                                                  support of standards-based wireless field instrumentation capabilities with the new
                                                                                                                  redundant Wireless I/O Card; (2) Extending the Control Network with wireless
                                                                                                                  communication; (3) Integrating wireless communication for both the Mobile Operator; and
                                                                                                                  (4) Remote Wireless Video integration embedded vision streaming in DeltaV Operate.

Workshop       Emerson Product/Services Update     98      DeltaV Operate Product Update                          The current release of DeltaV Operate includes new functionality to enhance operator
                                                                                                                  productivity. Com and join the session to gain a detailed look at what enhancments were
                                                                                                                  made.
Workshop       Emerson Product/Services Update     105     Fisher FIELDVUE Product Update                         We will review significant changes that have occurred with Fisher FIELDVUE
                                                                                                                  Instrumentation in 2010 and how it will affect Emerson customers. Highlights include:
                                                                                                                  release of the new DVC6200 HART and fieldbus linkageless/non-contact digital valve
                                                                                                                  controller, ValveLink Mobile for running diagnostics with a 475 or 375 Field Communicator or
                                                                                                                  PDA/Smartphone, and the 775 THUM for wireless communications with FIELDVUE
                                                                                                                  instruments. We will also review updates of the ValveLink Software product line.




                                                                                         Page 12 of 91                                                                                          (Rev. 051010)
                                                                         2010 Emerson Global Users Exchange
                                                                                 Sessions by Track



                                             Session
    Type                      Track                                                Title                                                                        Abstract
                                                ID
Workshop   Emerson Product/Services Update     148     New Game-changing Tank Gauging System from Emerson      Cut installation and maintenance expenditures with Emerson's new Inventory Grade Tank
                                                                                                               Gauging system that combines the best of existing and new technology. Well-proven FMCW-
                                                                                                               Radar technology for custody transfer grade accuracy. Based on open standards with 2-wire
                                                                                                               Foundation Fieldbus and Wireless communication protects your investment. Single 2-in-1
                                                                                                               unit with SIL3-Certification for both level and hi-alarm changes best-practices for overfill
                                                                                                               prevention dramatically.
Workshop   Emerson Product/Services Update     182     User Driven Enhancement Program Update: Voice and Drive The User Driven Enhancement (UDE) program provides the user community a mechanism
                                                       Your Ideas                                              to directly participate in and drive Emerson's product enhancement plans. Users collectively
                                                                                                               input and prioritize enhancement ideas theywould like to see in Emerson offerings. A UDE
                                                                                                               customer committee is empowered to manage the idea selection process and works with set
                                                                                                               Emerson resourcesand budget to put user ideas to action. -See the user ideas that were
                                                                                                               evaluated and selected for development -Meet UDE Committee members who represent the
                                                                                                               user community -Learn how users can voice and drive their ideas

Workshop   Emerson Product/Services Update     187     A PAT Solution for Pharmaceutical Manufacturing                Emerson and Optimal have jointly developed an integrated PAT solution for the
                                                                                                                      Pharmaceutical Industry. The solution combines the Optimal synTQ product with
                                                                                                                      Emerson's Syncade and DeltaV products. This presentation will review the solution
                                                                                                                      architecture and discuss the possible applications for the solution in Pharmaceutical
                                                                                                                      Manufacturing. A brief demonstration of the solution will be incorporated into the
                                                                                                                      presentation.
Workshop   Emerson Product/Services Update     210     Product Update on the Rosemount E-Series Magnetic              Diagnostic enhancements and additional output options increase the technology leadership
                                                       Flowmeter                                                      of the Rosemount E-Series Magnetic Flowmeter Platform.
Workshop   Emerson Product/Services Update     229     SmartProcess® Update                                           Over the past few years, Emerson has developed a number of industry-specific application
                                                                                                                      packages that are offered under the SmartProcess brand. The applications provide
                                                                                                                      templates, libraries and tools to optimize common process units, such as distillation
                                                                                                                      columns, fired heaters, fractionators, boilers and blenders. This year, new SmartProcess
                                                                                                                      applications were developed for Critical Equipment Monitoring of heat exchangers and
                                                                                                                      pumps. In addition, the Ethylene Furnace Optimizer completed its beta test with excellent
                                                                                                                      results. This session will review status, progress and plans for development and support of
                                                                                                                      SmartProcess applications.
Workshop   Emerson Product/Services Update     276     What Problem are you trying to solve? Uncovering the real      When asking your vendor for a particular feature, often the root problem is not exposed, as
                                                       problem at hand can lead to innovative solutions and new       the question is asked with a particular solution in mind. In many cases there may be better
                                                       product innovations.                                           solutions or new product features that could be developed to solve the problem, but these
                                                                                                                      may never see the light of day if the vendor does not know the root problem you are trying to
                                                                                                                      solve. This workshop will talk about how some of the new innovations in DeltaV were
                                                                                                                      derived and give other examples of approaching problem solving that can be applied to
                                                                                                                      other real world situations.
Workshop   Emerson Product/Services Update     327     Product Update: S-Series hardware                              This is a product update presentation covering DeltaV hardware available in v11, including S-
                                                                                                                      series hardware and Electronic Marshalling. Focus is on the latest hardware available and
                                                                                                                      upcoming CHARMs for v11.
Workshop   Emerson Product/Services Update     332     DeltaV system data integration for secure, industry standard   The DeltaV system continues to evolve and adopt new technologies to meet the growing
                                                       connectivity                                                   need for data integration. As the demand for data integration increases, so too does the
                                                                                                                      demand for securing this data. And the interfaces must be industry standards to allow best
                                                                                                                      of breed application integration. This presentation will provide a detailed look at several new
                                                                                                                      and updated data integration options in the DeltaV system, including OPC Xi, Web services
                                                                                                                      and high-speed Ethernet, which provide fast, efficient and secure means for DeltaV system
                                                                                                                      data integration from the plant floor to the enterprise.

Workshop   Emerson Product/Services Update     343     How Human Centered Design (HCD) principles in version 11       DeltaV innovation has focused on "ease of use" for more than a decade and have
                                                       has helped DeltaV users get more things done                   succeeded in making the lives of process and control professional's easier. However, many
                                                                                                                      innovations have required changes in work practices and have sometimes limited the
                                                                                                                      adoption rates of new technology. With the emphasis on Human Centered Design (HCD) in
                                                                                                                      DeltaV v11, Emerson's innovation is now focused on three main goals: 1) to Eliminating
                                                                                                                      Unnecessary Work, 2) to Reduce Complexity, and 3) to Embed Knowledge. This workshop
                                                                                                                      will talk about how HCD helps customer achieve more by using the new innovations in
                                                                                                                      DeltaV.




                                                                                     Page 13 of 91                                                                                               (Rev. 051010)
                                                                                        2010 Emerson Global Users Exchange
                                                                                                Sessions by Track



                                                           Session
    Type                        Track                                                              Title                                                                         Abstract
                                                              ID
Workshop   Emerson Product/Services Update                   351     Fisher Control-Disk Valve Development and Future                 The Rotary Product Development Group at Fisher Controls released the Control-Disk Valve
                                                                     Extensions                                                       to be used in general service control valve applications. This product line was designed for
                                                                                                                                      quick lead-times, easy maintenance, and high marks for reliability. It also introduces the
                                                                                                                                      patented equal percentage disk, which improves upon the narrow control range exhibited by
                                                                                                                                      high performance butterfly valves.
                                                                                                                                          This presentation will cover the development of the Control-Disk Valve, the engineering
                                                                                                                                      behind the equal percentage disk, future extensions of this technology, and how this product
                                                                                                                                      can help you the customer.
Workshop   Emerson Product/Services Update                   367     High-Tech Teamwork: Turnkey Solutions Offer Increased            Continually improving plant performance through increased revenues and decreased
                                                                     Reliaibility                                                     expenses is the biggest challenge when legacy products are taxed by current demand.
                                                                                                                                      When customers encounter issues that cross multiple crafts, gathering all the necessary
                                                                                                                                      players can be risky and time consuming. Emerson now offers complete project
                                                                                                                                      management to provide turnkey solutions that led to increased reliability of CVX valves.

Workshop   Emerson Product/Services Update                   370     Product Update: DeltaV Digital Bus Technologies                  This presentation will detail recent functionality and Ease of Use improvements to the
                                                                                                                                      implementation of digital bus technologies in the DeltaV system. Each new feature will be
                                                                                                                                      described along with the benefit(s) to the user. The workshop will also allow users to provide
                                                                                                                                      feedback on current digital bus functionality and usability to the DeltaV product marketing
                                                                                                                                      organization.
Workshop   Emerson Product/Services Update                   377     Building a More Fault Tolerant System with Redundant             One of the most common means to achieve a fault tolerant system is through the use of
                                                                     Components                                                       redundant components. Redundancy can be deployed to minimize the effects of many faults
                                                                                                                                      to maintain the availability of the system. However, redundancy is not a one-size fits all
                                                                                                                                      solution as it does have some hidden costs. This workshop will explore the redundant
                                                                                                                                      components of the DeltaV DCS and uncover the faults that each were designed to protect
                                                                                                                                      against. In addition the workshop will discuss the design issues and tradeoffs made by
                                                                                                                                      software developers as they work to create a more fault tolerant product.

Workshop   Instrumentation Applications. Instrumentation     21      Instruments in Supercritical Biodiesel Process                   Handling high FFA waste trap grease and other multiple characteristic feedstocks requires
                                                                                                                                      design and application detail that differs from standard clean fluid applications. Using
                                                                                                                                      supercritical technology to convert and vacuum distillation to refinethe material into ASTM
                                                                                                                                      6751 specification biodiesel presents challenges to instrument applications. We will review
                                                                                                                                      the flow, pressure, level and temperature instrument applications throughout the process
                                                                                                                                      that has been producing fuel since March of 2009.
Workshop   Instrumentation Applications. Instrumentation     22      Foundation Fieldbus, faster, safer, more reliable plants
                                                                                                                                        Big $ returns are available when Foundation Fieldbus is used.
                                                                                                                                        Using control in the field with intelligent measurement and control devices is 3x more
                                                                                                                                      reliable than conventional analogue.
                                                                                                                                        This paper builds on newmodeling work completed by ISC Ltdwhich shows that Control in
                                                                                                                                      the Field can deliver over 30% tightercontrol response and rejection of disturbance.
                                                                                                                                        "major benefits identified are reduced process controller loading, reduced network traffic
                                                                                                                                      enabling more loops per segment, as well as very fast loop response"

Workshop   Instrumentation Applications. Instrumentation     24      Your overfill alarm doesn’t howl very often. Are you sure it’s   Any conventional overfill alarm sensor you may choose for your storage tanks, such as a
                                                                     alert?                                                           point level switch, will have one major weakness: You can never be absolutely sure that it
                                                                                                                                      still works after a long (or short) period of inactivity. Radar based overfill alarm offers a
                                                                                                                                      better solution. It enables continuous feedback to the operator by checking the level multiple
                                                                                                                                      times per second. On top of that it can provide SIL rated alarm outputs and redundancy
                                                                                                                                      options.
Workshop   Instrumentation Applications. Instrumentation     30      Are You A “Process Whisperer?” - Best Practices For              Your process is "whispering" its diagnostic secrets to you, but are you listening? There are
                                                                     Successful Process Diagnostics With Fast Sampling                many documented applications using advanced process diagnostics with smart pressure
                                                                     Pressure Transmitters                                            transmitters. This workshop will review the currently documented diagnostic applications
                                                                                                                                      with a pressure transmitter. Then, it will go on to discuss best practices to identify and
                                                                                                                                      implement a successful diagnostic application in your process.




                                                                                                     Page 14 of 91                                                                                                (Rev. 051010)
                                                                                       2010 Emerson Global Users Exchange
                                                                                               Sessions by Track



                                                           Session
    Type                        Track                                                             Title                                                                      Abstract
                                                              ID
Workshop   Instrumentation Applications. Instrumentation      75     A journey of 1st generation Mechanical Level Indication to   This paper discusses the problems faced due to MLI & DP Type LTs, Annunciation and,
                                                                     cutting edge technology of RADAR type Level System, in       methodology adopted to overcome by using RADAR Type LTs in both the tank-farms, at
                                                                     TankFarm Unit, at Reliance, Patalganga, INDIA.               Reliance, PG, India . It focus on improvement carried out, benefits achieved &
                                                                                                                                  advantages found in PCs Networking.
                                                                                                                                    Accordingly, the article addresses:
                                                                                                                                    1.Up-gradation of MLI with RADAR Type LTs with cutting edge technology and reliability
                                                                                                                                  improvement
                                                                                                                                    2.Automatic accounting of Final product & report generation
                                                                                                                                    3.Level trends & Alarm management
                                                                                                                                    4.Networking
Workshop   Instrumentation Applications. Instrumentation     94      Water Draw Control Scheme                                    The project was put in place to control water draw on crude tanks at the Valero Memphis
                                                                                                                                  Refinery
Workshop   Instrumentation Applications. Instrumentation     96      ACHIEVING REDUNDANT INTRINSICALLY-SAFE                       During the last year or so, a variety of approaches have been released offering users new
                                                                     FIELDBUS SEGMENTS FOR FISCO & ENTITY DEVICES                 fieldbus segments with redundancy and FISCO device connectivity. This paper describes
                                                                                                                                  and compares those new designs with regard to segment capacity, MTBF, overall
                                                                                                                                  availability, installation areas and implementation cost .
Workshop   Instrumentation Applications. Instrumentation     106     Emerson Interfaces to SmartPlant Instrumentation             Emerson has more interfaces to Intergraph's SmartPlant Instrumentation ( SPI ) than any
                                                                                                                                  other process controls supplier. This workshop will address t he mechanics of SmartPlant
                                                                                                                                  Instrumentation ( SPI ) interfaces to Fisher Specification Manager, Rosemount
                                                                                                                                  Instrument Toolkit, and DeltaV DCS Configuration tools, How the interfaces work in Real
                                                                                                                                  World situations and what is the future of Emerson interfaces and integration to engineering
                                                                                                                                  automation tools.
Workshop   Instrumentation Applications. Instrumentation     146     EDDL Enhancements and Device Dashboards are the              Historically, level measurement instruments were hard to commission and maintain because
                                                                     Building Blocks for Easy Commissioning and Valuable Level    the set-up tools were difficult for the operator to interpret. EDDL with enhancements are the
                                                                     Diagnostics                                                  building blocks for constructing a user interface that is consistent for all connected device
                                                                                                                                  types. At the host system, a user-friendly Device Dashboard provides intuitive set-up of
                                                                                                                                  remote devices and access to valuable diagnostics. Plant personnel can better utilize their
                                                                                                                                  instrumentation thereby decreasing maintenance costs, increasing plant availability, and
                                                                                                                                  reducing safety risks.
Workshop   Instrumentation Applications. Instrumentation     152     SIL3-certified 2-in-1 Radar completely redefines best-       With the all-new 2-in-1 Radar Level Gauge both custody-transfer grade level measurement
                                                                     practices for overfill prevention in tank farms              and overfill prevention can be performed in the same unit. And it's certified according to
                                                                                                                                  IEC61508 for SIL3 safety-loops. Having a single unit considerably reduces cost, fewer
                                                                                                                                  device types, single tank-penetration. Continuous measurement for both level and overfill
                                                                                                                                  can be used for delta-evaluation or "24/7 proof-testing" which reduces proof-testing intervals.

Workshop   Instrumentation Applications. Instrumentation     157     Measuring Levels in Highly Dynamic Petroleum Processes       Measuring liquid levels in highly dynamic petroleum processes can be very challenging.
                                                                                                                                  Rapid level changes, changing liquid densities, boiling liquids, and interface fluids can
                                                                                                                                  combine to make it difficult to get an accurate and/or stable measurement. This workshop
                                                                                                                                  will discuss several of these difficult hydrocarbon applications that occur in gas plants and
                                                                                                                                  refineries, and the solutions found using the various measurement abilities of high
                                                                                                                                  performance guided wave radar. We will also explore how to best set up the measurement
                                                                                                                                  in order to improve loop tuning.
Workshop   Instrumentation Applications. Instrumentation     162     Use of Smart Plant Instrumentation (SPI) in Factory          Smart Plant Instrumentation (SPI) is a key tools in the world of Controls and Instrumentation
                                                                     Acceptance Testing                                           field. A powerful tool to access the instrumentation database and used by many users from
                                                                                                                                  Client to engineering firms to automation industry.

                                                                                                                                     Content of the slides show how effective and powerful SPI can be not only for engineering
                                                                                                                                  activities but also for automation part of the engineering. It also describes the additional
                                                                                                                                  fields that can be used in intools to help automation and automation FAT activities.

Workshop   Instrumentation Applications. Instrumentation     172     Is your Steam Application getting hot?                       A challenge in the power and steam generation is to be able to measure level accurately and
                                                                                                                                  reliably in high pressure saturated steam applications such as boiler drums, high pressure
                                                                                                                                  feed water heaters, and steam separators. With the innovative technique Dynamic Vapor
                                                                                                                                  Compensation (DVC) in Guided Wave Radar (GWR) this is overcome. The workshop will
                                                                                                                                  review how saturated vapor affects the measurement and provide 'best practice' guidelines
                                                                                                                                  for solution as well as show real life examples.




                                                                                                    Page 15 of 91                                                                                             (Rev. 051010)
                                                                                        2010 Emerson Global Users Exchange
                                                                                                Sessions by Track



                                                           Session
    Type                        Track                                                              Title                                                                          Abstract
                                                              ID
Workshop   Instrumentation Applications. Instrumentation     179     Radar technology has increased accuracy and reliability             The EKA Chemicals plant utilized radar technology to automate sanitary sewer level. Eka
                                                                     eliminating potential of costly fines from the City Municipality!   was originally using non-contacting radar and traditional DP based level technologies. They
                                                                                                                                         upgraded to the Rosemount 3300 contacting radar which has increased the accuracy and
                                                                                                                                         reliability of the measurement and decreased their maintenance costs, while at the same
                                                                                                                                         time eliminating the potential of costly fines from the city municipality.

Workshop   Instrumentation Applications. Instrumentation     207     How contacting Radar technology has replaced load cell              Red Arrow utilized contacting radar to automate the continuous level in a surge bin. The
                                                                     technology to increase throughput and enable continuous             use of radar has enabled this process to be controlled continuously, which has increased
                                                                     automated control.                                                  process throughput, improved the reliability of the measurement, reduced routine
                                                                                                                                         maintenance time, increased safety, and enabled them to automate the level control.

Workshop   Instrumentation Applications. Instrumentation     218     Does that level really match what is inside my tank? Practical Chambers and stilling wells can facilitate measurements with Guided Wave and Non-
                                                                     Solutions for Optimizing Radar Level Measurements in           Contacting Radar level transmitters. Yet if done incorrectly, they can be a source of errors.
                                                                     Chambers and Stilling Wells                                    Optimal results can be obtained by following a few basic guidelines. Choices of radar type,
                                                                                                                                    antennas or probe, setup tips, and special considerations for interface or steam applications
                                                                                                                                    will be covered.
Workshop   Instrumentation Applications. Instrumentation     224     Driving Automation in Municipal Wastewater Plants              Advances in technology have made motion control equipment robust, economical, and a key
                                                                                                                                    piece of instrumentation to the process industry. This session takes a look at the uses of
                                                                                                                                    drives in the wastewater treatment facilities and their unique value proposition for energy
                                                                                                                                    savings and performance improvements. Many of these improvements and savings can be
                                                                                                                                    employed in other process applications as well such as power and energy, oil and gas, life
                                                                                                                                    sciences and more.
Workshop   Instrumentation Applications. Instrumentation     256     Wine Production Optimization thru Mass Balance at Bodega Bodega Norton, located in Mendoza, was nominated as one of the top 20 wineries in the
                                                                     Norton in Argentina                                            World and it is one of the leading and traditional wineries with the longest trajectory in
                                                                                                                                    Argentina and presence in the main markets worldwide. The well-known quality causes their
                                                                                                                                    wines to be distributed in over 60 countries around the World and enjoyed by millions of
                                                                                                                                    consumers every day. The purpose of this application is to reduce losses between the wine
                                                                                                                                    cellar and the fractionation plant with a mass balance.
Workshop   Instrumentation Applications. Instrumentation     263     Up from the Depths: Rapid Response Means Real Recovery In September of 2009, a 500 year flood brought $250 million damages to a Northern Georgia
                                                                                                                                    Paper Mill. Although not a current Emerson customer at the time, Instrument & Valve
                                                                                                                                    Services was contracted along with local business partner—Control
                                                                                                                                    Southern—to assist in recovery efforts. This presentation will demonstrate a case
                                                                                                                                    study of how swift mobilization of experienced, qualified technicians who built on their
                                                                                                                                    knowledge in flood recovery, brought the plant back online.
Workshop   Instrumentation Applications. Instrumentation     297     How to win a custody battle. Properly instrumenting custody Custody transfer applications have an immediate impact on a plant's bottom line. Proper
                                                                     transfer points for maximum ROI.                               instrument selection, installation, and ongoing maintenance are critical success factors for
                                                                                                                                    successful plant economics.
Workshop   Instrumentation Applications. Instrumentation     310     The Balancing Act of Flow Meter Selection                      With advancements being made in flow measurement technology, the decision of which flow
                                                                                                                                    meter to use has become increasingly more complex. When does Installed Cost take
                                                                                                                                    preference over Reference Accuracy? When do Permanent Pressure Loss and/or Energy
                                                                                                                                    Costs need to be the critical priorities? All of these questions affect the decision of which
                                                                                                                                    flowmeter is right for your application.
Workshop   Instrumentation Applications. Instrumentation     317     Measuring Critical Temperature using Multivariable             Temperature profiles of reactors, tanks and other vessels are common throughout the
                                                                     Transmitters                                                   industry. While these might be viewed as monitoring points they are often of critical
                                                                                                                                    importance. This paper will explore how to use both wired and wireless multivarible
                                                                                                                                    transmitters to provide both a cost effective installation with the required reliability.
Workshop   Instrumentation Applications. Instrumentation     325     Level ABC for EPC                                              In the competitive environment of Engineering, Project execution and Construction (EPC),
                                                                                                                                    the key factors that influences business result are project risks, costs and schedules. During
                                                                                                                                    this session, we will share experiences and best practices to assist EPCs how to cut project
                                                                                                                                    risk, capital spending, startup time, and shorten project schedule. We will discuss
                                                                                                                                    Emerson'sorganizational and product capabilities that has proven to add all of the mentioned
                                                                                                                                    values to EPCs already and provide the Level ABC tailored for EPCs.




                                                                                                     Page 16 of 91                                                                                                (Rev. 051010)
                                                                                       2010 Emerson Global Users Exchange
                                                                                               Sessions by Track



                                                           Session
    Type                        Track                                                             Title                                                                        Abstract
                                                              ID
Workshop   Instrumentation Applications. Instrumentation     328     The Top 10 ERS Applications for 2010                           Emerson has spent the past several years designing a new DP Level technology, the
                                                                                                                                    Rosemount 3051S Electronic Remote Seal System (ERS). ERS works on many of the same
                                                                                                                                    premises as today's DP Level technology with one exception: the mechanical capillary and
                                                                                                                                    impulse piping that can be problematic in tall vessels and distillation columns are completely
                                                                                                                                    replaced with a digital architecture. This paper will provide a brief overview of the ERS
                                                                                                                                    technology and then go into detail on the top 10 applications where engineers have already
                                                                                                                                    deployed ERS and achieved tangible results.
Workshop   Instrumentation Applications. Instrumentation     329     How Process Insight Leads to Actionable Information at         Mitsubishi Chemical, recipient of the 2009 HART Plant of the Year Award, is back again to
                                                                     Mitsubishi Chemical                                            present new application findings with HART diagnostics. Virtually all dynamic processes
                                                                                                                                    have distinctive noise profiles. Applying the advanced diagnostic capabilities found in
                                                                                                                                    Pressure Transmitters allows users to profile their process. Users gain more process insight
                                                                                                                                    and make quality decisions based on actionable information.
Workshop   Instrumentation Applications. Instrumentation     330     Demystifying Guided Wave Radar                                 During this session, we will shed light on common rumors, misconceptions, and "mysteries"
                                                                                                                                    with the Guided Wave Radar technology. Skilled subject matter experts will discuss your
                                                                                                                                    GWR mysteries and share reasons and recommended actions to demystify the technology.
                                                                                                                                    This session will focus on interaction and live demonstrations to build on your GWR
                                                                                                                                    knowledge. Through proper selection of GWR technology, users experience positive
                                                                                                                                    business results such as decreased maintenance and operations costs, reduced safety
                                                                                                                                    risks, and decreased risk of unplanned shutdown.

Workshop   Instrumentation Applications. Instrumentation     336     Improving Heater Firing Control and Efficiency with Better     Reducing excess air flow to boilers and fired heaters without compromising safety and
                                                                     Damper Performance                                             reliability is one way to improve energy efficiency and profitability of refining operations.
                                                                                                                                    However, these efforts are hampered by poorly performing combustion air and flue gas
                                                                                                                                    dampers. Damper design and damper actuator performance specifications were developed
                                                                                                                                    and implemented to realize more stable and efficient boiler and fired heater operations.

Workshop   Instrumentation Applications. Instrumentation     337     LyondellBasell Realizes Better Maintenance Practices with      The Clinton complex for LyondellBasell's Equistar subsidiary is one of the largest chemical
                                                                     Advanced Diagnostics                                           plants Iowa. This plant utilizes advanced diagnostics from pressure transmitters combined
                                                                                                                                    with best-in-class maintenance practices to achieve lower operation costs while improving
                                                                                                                                    production of ethylene. This paper will discuss specific applications where advanced
                                                                                                                                    diagnostics were used to uncover opportunities for proactive maintenance.

Workshop   Instrumentation Applications. Instrumentation     346     Level Solutions for Refining can Increase Safety and Reduce The short course will review key level applications in refineries with special considerations
                                                                     Maintenance - If Chosen and Installed Correctly             for level measurements in critical applications. In refineries there are several applications
                                                                                                                                 where the process conditions are difficult and traditional technologies are high on
                                                                                                                                 maintenance costs and/or do not track the changes fast enough. During this short course we
                                                                                                                                 will look closer on how radar with high sensitivity can resolvevery demanding process
                                                                                                                                 conditions, thus optimizing performance, increasing safety,and reducing the maintenance
                                                                                                                                 costs.
Workshop   Instrumentation Applications. Instrumentation     350     High Density Temperature Transmitters in Gasification Pilot Gas Technology Institute (GTI) recently commissioned the Advanced Gasification Test
                                                                     Plant                                                       Facility (AGTF), an addition to its Flex-Fuel Testing Facility (FFTF) for pilot-scale gasification
                                                                                                                                 and gas processing systems for commercialization of more efficient energy-conversion
                                                                                                                                 processes. Critical process measurement points must be monitored, with data collected and
                                                                                                                                 analyzed to verify the process performance. In the reactors, high density temperature
                                                                                                                                 monitoring solutions, utilizing the Rosemount 848T and DeltaV, were employed to achieve
                                                                                                                                 this goal effectively.
Workshop   Instrumentation Applications. Instrumentation     365     Battle Royale - HART7 VS Foundation fieldbus                HART and Foundation fieldbus have brought significant benefits to the process industry.
                                                                                                                                 HART enabled device intelligence but has always just been considered an extension to the 4-
                                                                                                                                 20mA signal. Foundation fieldbus has always been known for its Control-in-the-field and
                                                                                                                                 expanded diagnostics and diagnostic information capability. Word on the streets is that the
                                                                                                                                 improvements made in HART revision 7 are powerful enough to take on Foundation
                                                                                                                                 fieldbus. The paper explores the similarities and differences of the two so you can make an
                                                                                                                                 educated decision on which protocol is best for your plant or application.

Workshop   Instrumentation Applications. Instrumentation     366     Temperature Monitoring and Control of Reactor Performance




                                                                                                    Page 17 of 91                                                                                               (Rev. 051010)
                                                                                        2010 Emerson Global Users Exchange
                                                                                                Sessions by Track



                                                           Session
    Type                        Track                                                             Title                                                                        Abstract
                                                              ID
Workshop   Instrumentation Applications. Instrumentation     372     Level Solutions for Power can increase plant efficiency - if   In steam generation facilities, there are applications where having a reliable, accurate and
                                                                     chosen and installed correctly                                 safe level measurement is a key to improving efficiencies. Yet there are some special
                                                                                                                                    challenges that must be met to ensure the optimum results for efficiency and reduced
                                                                                                                                    maintenance. This short course will review key level applications with special considerations
                                                                                                                                    for upgrading and optimizing level control in feedwater heaters, boiler drums and related
                                                                                                                                    equipment as well as tactics for equipment protection. Best practices for installation of the
                                                                                                                                    various level technologies will be covered.
Workshop   Instrumentation Applications. Instrumentation     381     Making Fieldbus Safer in Hazardous Locations                   This presentation will consider recent advances in technology and products that have
                                                                                                                                    contributed to the safety of Foundation fieldbus networks in hazardous locations. Among
                                                                                                                                    the technologies adopted world-wide are the 'Fieldbus Intrinsically Safe Concept' (FISCO),
                                                                                                                                    and the 'High Energy Trunk' technique which uses Fieldbus Barriers to convert to
                                                                                                                                    intrinsically safe spurs in the field junction box. The presentation will explain how more
                                                                                                                                    recent product innovations have contributed to improved safety,reliability and ease of use.

Workshop   Instrumentation Applications. Instrumentation     382     ITK6 What does it mean for you!                                The Foundation fieldbus Interoperability Test Kit (ITK) is an interoperability/conformance test
                                                                                                                                    required for Foundation fieldbus certification. The testing jumped a major revision this year
                                                                                                                                    to ITK6. The paper reviews the history of ITK, compares the revisions, and expounds on the
                                                                                                                                    new mandatory and optional components of the test. Come see why requiring ITK6 may not
                                                                                                                                    get the same features in all devices and how to refine your Foundation fieldbus device
                                                                                                                                    specifications.
Workshop   Instrumentation Applications. Instrumentation     383     What’s the Buzz? Wake Frequency Calculations and What          Our understanding of Wake Frequency and thermowell operation in harsh process
                                                                     You Need to Know                                               conditions has
                                                                                                                                    come a long way, and ASME PTC 19.3TW is being released. What does this mean for
                                                                                                                                    you? Learn how to ensure your thermowells are designed to meet and exceed the
                                                                                                                                    requirements and how Emerson can help you become a thermowell expert.

Workshop   Instrumentation Applications. Instrumentation     395     New Sand Management System Integrates Erosion Based            Using an example and field data from Statoil, this paper presents a new sand management
                                                                     and Acoustic Sensors alongside a New Generation Sand           system, where acoustic and erosion-based sand sensors are combined and integrated
                                                                     Management Software – An Operator Example                      together with new sand management software, to enable increased system availability, more
                                                                                                                                    extensive information, and improved alarm settings providing a platform for effective
                                                                                                                                    condition based monitoring.
Workshop   Instrumentation Applications. Instrumentation     399     Give your plant a HART7 attack                                 Advances in HART communication protocol allow users to get more information from their
                                                                                                                                    field devices. This additional information includes device diagnostics and notifications, data
                                                                                                                                    history, and simulation of digital variables. Come see how easy it can be to take advantage
                                                                                                                                    of these improvements, and ensure you get the most value out of your field devices.

Workshop   Instrumentation Applications. Instrumentation     418     Great Protocols Think Alike - Profibus and Foundation          Jacobs Technology designs and builds wind tunnels for testing virtually anything that moves
                                                                     fieldbus Team Up on a Fascinating Application                  under virtually any set of environmental conditions. Their designs depend upon very
                                                                                                                                    accurate flow measurement and precise drive control for their high powered fans. This paper
                                                                                                                                    describes how a recent installation combined the use of Profibus DP for fan drive control
                                                                                                                                    and other functions while using Foundation fieldbus for process instrumentation

Workshop   Instrumentation Applications. Instrumentation     423     Steam Flow Measurement in Cold Climates - New Best
                                                                     Practices                                                       Steam flowmeters are often located outdoors in the upstream and downstream
                                                                                                                                    hydrocarbon and chemical industries. Accurate flow measurements are needed to maintain
                                                                                                                                    process efficiency, detect leaks and account for consumption. Cost-effectively ensuring
                                                                                                                                    high accuracy, repeatability and reliability is a challenge, especially in cold climates.
                                                                                                                                    Traditional practices are reviewed, followed by new best practices. These new practices
                                                                                                                                    have demonstrated improvements in reliability and turndown, at lower initial and life cycle
                                                                                                                                    cost. Presented at Canadian School of Hydrocarbon Measurement in Calgary , 2010.

Workshop   Instrumentation Applications. Instrumentation     428     Keeping a level head for better measurement results            Are you looking for actionable ways to improve your measurement and business results with
                                                                                                                                    DP Level systems? This workshop will cover: parameters that have the biggest impact on
                                                                                                                                    performance; limitations of old DP Level practices; system selection and specification; and
                                                                                                                                    best installation practices including Tuned-Systems Assemblies and Wireless DP Level.




                                                                                                    Page 18 of 91                                                                                               (Rev. 051010)
                                                                                       2010 Emerson Global Users Exchange
                                                                                               Sessions by Track



                                                           Session
    Type                        Track                                                             Title                                                                         Abstract
                                                              ID
Workshop   Instrumentation Applications. Instrumentation     431     Tank Level Surprisingly High?                                   This paper will discuss the advantages of using radar gauges and level switches to protect
                                                                                                                                     tanks from overfilling and causing costly cleanup and environmental damages. It will also
                                                                                                                                     cover using the advanced diagnostics in conjunction with AMS to determine the health of
                                                                                                                                     the transmitter and validity of the process variable.
Workshop   Instrumentation Applications. Instrumentation     436     Top 10 Ways to Speed Project Execution with Better              End users and engineering contractors are constantly challenged with project execution to
                                                                     Instrumentation Practices                                       meet or exceed budget and timelines. But does instrumentation have an impact on project
                                                                                                                                     success? This workshop will show you how to specify and quote optimal solutions for your
                                                                                                                                     measurement applications, leverage a common platform across multiple applications, and
                                                                                                                                     engineer, procure & commission instruments effectively to improve project execution,
                                                                                                                                     resulting in faster start-up and reduced costs.
Workshop   Instrumentation Applications. Instrumentation     438     Can I Detect a Plugged Impulse Line using Advanced              Plugging in pressure measurement impulse lines is an expensive and time-consuming
                                                                     Pressure Diagnostics?                                           problem in process plants. Pressure transmitters with HART or Foundation Fieldbus
                                                                                                                                     Advanced Diagnostics provide the ability to detect this plugging by monitoring for changes in
                                                                                                                                     the process dynamics. Successful implementation of plugged impulse line detection may
                                                                                                                                     depend upon numerous factors, including fluid type, primary element, and impulse line state.
                                                                                                                                      This workshop will present these various considerations and provide guidance on selecting
                                                                                                                                     the best applications for plugged impulse line detection.
Workshop   Instrumentation Applications. Instrumentation     441     Valero St. Charles Tank Gauging Modernization, Best             Existing tank farms are equipped with old mechanical tank gauges or misapplied process
                                                                     Practices                                                       radar level transmitters. New demands for more accurate product inventory assessments
                                                                                                                                     and better overfill safety require modern equipment.
                                                                                                                                       To accommodate an easy migration to new tank gauging systems certain best practices
                                                                                                                                     should be followed to save cost and to make the new system conform to established
                                                                                                                                     engineering and safety standards.
                                                                                                                                       This presentation describes a typical tank gauging system upgrade, the steps needed to
                                                                                                                                     make it work properly and the benefits that it brings with it.
Workshop   Instrumentation Applications. Instrumentation     456     ERS: Bringing DP Level to New “Heights”                         Keeping up to speed on the latest in measurement technologies and best practices does not
                                                                                                                                     have to be as difficult as learning a foreign language. The new Rosemount 3051S
                                                                                                                                     Electronic Remote Seal (ERS) system is a digital upgrade to a proven and well-understood
                                                                                                                                     technology: DP Level. This paper will build your knowledge on ERS technology while
                                                                                                                                     describing the user benefits and considerations for use with other DP Level technologies.

Workshop   Instrumentation Applications. Instrumentation     490     Inspect Your Gadgets: The Fundamental Features Hidden           Your installed temperature transmitter has features and diagnostics integral to its basic
                                                                     Inside Your Temperature Transmitters                            design that can be used to track, mitigate or diagnose process and device abnormalities.
                                                                                                                                     These features are fundamental to helping you understand your process variables. Do you
                                                                                                                                     know what these features are and how to use them? Discover how to utilize your
                                                                                                                                     Rosemount Temperature Transmitters to their fullest abilities, and you can be sure to get the
                                                                                                                                     most out of your Single and High Density Temperature Measurement Points!

Workshop   Instrumentation Applications. Instrumentation     496     I can't believe it's not balanced.... A better way to measure   Are you having difficulties getting your DP Level measurement system to perform the way
                                                                     level.                                                          you expect? This paper will discuss types of measurement error in DP level systems and
                                                                                                                                     provide a clear roadmap for improving overall system performance.
Workshop   Instrumentation Applications. Instrumentation     498     The RIGHT way to do Temperature: Best Practices for
                                                                     Installation, Commissioning, and general Temperature               With over 50 years of experience helping customers install and maintain their temperature
                                                                     measurement                                                     equipment we've documented some real behaviors that can help decrease installation time,
                                                                                                                                     prevent future maintenance and give you more confidence in your Temperature
                                                                                                                                     measurements. This workshop will outline the practical things YOU can do to improve and
                                                                                                                                     simplify your overall temperature operations.
Workshop   Instrumentation Applications. Instrumentation     509     Smart Field - does instrumentation really matter?               The future is here, today. We've crossed the chasms together; pneumatic to analog, analog
                                                                                                                                     to smart, wired to wireless. Today we have instruments with more computing power than the
                                                                                                                                     first controller. The question is, are we using technology in a meaningful way, or more
                                                                                                                                     importantly in a way that has a positive business result? This course will explore the benefits
                                                                                                                                     of a Smart Field and the potential business results.




                                                                                                     Page 19 of 91                                                                                               (Rev. 051010)
                                                                                           2010 Emerson Global Users Exchange
                                                                                                   Sessions by Track



                                                               Session
     Type                           Track                                                             Title                                                                         Abstract
                                                                  ID
Short Course   Instrumentation Applications. Instrumentation     512     Introducing the “other” fieldbus: The basics, benefits, and   For the vast majority of Emerson users, the term "fieldbus" refers solely to Foundation
                                                                         how to of Profibus                                            fieldbus. Well this year, Emerson is launching a complete portfolio of solutions that
                                                                                                                                       communicate on the industry's other fieldbus, Profibus.
                                                                                                                                       This short course introduces users to the Profibus protocol. We will begin with a 30 minute
                                                                                                                                       presentation reviewing the history, trends, and applications where Profibus has brought
                                                                                                                                       value to end users. We will then move from screen to labs and guide users through
                                                                                                                                       implementing their own Profibus system - setting up a network and commissioning devices.


Workshop       Instrumentation Applications. Instrumentation     533     2120 as a direct replacement for a float switch integrating   This customer wanted to use a 2120 as a direct replacement for a float switch and bring the
                                                                         directly into a Honeywell TDC 3000                            input directly into their Honeywell TDC 3000 without reconfiguring any hardware and utilize
                                                                                                                                       the exisiting Digital Input card. The utilization of vibrating fork level switches aligns with the
                                                                                                                                       philisophy of replacing mechanical devices with devices that are capable of increasing safety
                                                                                                                                       and reliability while reducing maintenance costs and increase production through diagnostic
                                                                                                                                       capabilities of the switch, and the testing ability available on the 2120 while still in service.


Workshop       Instrumentation Applications. Instrumentation     537     Geothermal Industry Needs Accurate Level for NCG              In the geothermal industry at production wells, reliable and accurate level measurements are
                                                                         Separators                                                    critical in non-condensable gas (NCG) separators for efficient operations and to prevent
                                                                                                                                       booster pump damage and shutdown of operations. High level would result in carryover
                                                                                                                                       and system damage and inefficiencies. Low level would cause booster pump damage and
                                                                                                                                       downtime. The innovative Rosemount high temperature/high pressure guided wave radar
                                                                                                                                       probe is perfect for our operating conditions.

Workshop       Instrumentation Applications. Instrumentation     127     Reducing Bias and Uncertainty in Process Gas Quality          Ensuring robust measurements of natural gas quality is a combination of good sampling, a
               Analytical                                                Measurements                                                  properly validated gas chromatograph and a traceable calibration gas. Omitting any of
                                                                                                                                       these key elements will result in biased measurements of composition and hence the
                                                                                                                                       calculated physical properties of heating value, density and Wobbe Index. Even small errors
                                                                                                                                       over time will result in large financial discrepancies, particularly at fiscal metering points with
                                                                                                                                       a large throughput.
Workshop       Instrumentation Applications. Instrumentation     289     Simplified Gas Chromatograph Installations & Operations       Gas chromatographsarevaluable analytical tools in many plant and pipeline operations. Their
               Analytical                                                with Foundation fieldbus                                      installations and operations though are often considereddifficult and labor intensive. The
                                                                                                                                       700XA and 1500XA gas chromatographs fromEmerson Process Management'sRosemount
                                                                                                                                       Analytical change this perception, utilizing a Foundation fieldbus interface - the world's first
                                                                                                                                       and only certified Foundation fieldbus interface on a gas chromatograph.

Workshop       Instrumentation Applications. Instrumentation     368     Implementing Hybrid First-Principles/Empirical Models for     A model pharmaceutical system controlled by Delta V and SynTQ was used to show
               Analytical                                                Pharmaceutical Manufacturing through Automated Controls       enhancements to a fluid bed drying process. It used a first-principles model and direct
                                                                                                                                       measurements of CQAs (water content) to reduce time/energy required for the process, and
                                                                                                                                       reduced variability. DeltaV controlled the fluid bed dryer, SynTQ coordinated data collection
                                                                                                                                       and analysis from multiple univariate and spectroscopic systems. Further, SynTQ passed
                                                                                                                                       the conditioned data to the analytical and control models and reported desired set points to
                                                                                                                                       the DeltaV system. This system serves as a model for future manufacturing in the
                                                                                                                                       pharmaceutical industry.
Workshop       Instrumentation Applications. Instrumentation     449     Discrete Control Solutions using Mulit-parameter Analyzers    This paper addresses the chemical concentration control and dosing using the discrete
               Analytical                                                                                                              funtionality inmultiparameteranalyzers. It addressesinterfacewith the control system and
                                                                                                                                       AMS and use of wireless communcation in these applications which include plant utilities
                                                                                                                                       and skids.
Workshop       Instrumentation Applications. Instrumentation     536     Challenges of integrating anayzers systems in Integrated      Whiel automation is rapidly converging where many diverse systems are sharing common
               Analytical                                                Process Control                                               platforms and automation resources; however the analytical systems are lagging behind and
                                                                                                                                       thus face underutilization of their capabiliites of process controls, and being treated like
                                                                                                                                       black boxes. The interface and diverse technolgies add to the complexity of integration.




                                                                                                        Page 20 of 91                                                                                                 (Rev. 051010)
                                                                                       2010 Emerson Global Users Exchange
                                                                                               Sessions by Track



                                                           Session
    Type                        Track                                                             Title                                                                      Abstract
                                                              ID
Workshop   Instrumentation Applications. Instrumentation      61     Improving Measurement Quality and Efficiency using Coriolis Sonacol is a Chilean oil pipeline operator with a 700 km network for refined products
           Flow                                                      Technology                                                  (LPG, diesel, gasolines, etc.)The company is owned by top the leading companies of the
                                                                                                                                 fuel sector in Chile . Total production amounts to approximately 5.000.000 m3/year.

Workshop   Instrumentation Applications. Instrumentation     89      Coriolis Meters: Changing the Marine Bunker Fuel Industry    Accurate measurement of heavy fuel oil bunkering can save thousands in accurate billing
           Flow                                                                                                                   and reduced operating expense. The bunker fuel industry is challenged converting
                                                                                                                                  volumetric to mass measurement due to many variables, though mass measurement
                                                                                                                                  provides the certainty needed. Coriolis mass measurement provides a more accurate and
                                                                                                                                  cost effective fuel bunker measurement and is changing the way the Bunker industry
                                                                                                                                  handles HFO. Bunker barge operators now deliver accurate quantities of fuel while the
                                                                                                                                  vessel operators are certain they are getting the quantity and quality of fuel they are buying.

Workshop   Instrumentation Applications. Instrumentation     100     Fiscal and Allocation Measurement Philosophy for a Ultra
           Flow                                                      large Refinery in Asia using Over Eighty Liquid Ultrasonic    The use of Liquid Ultrasonic Meters for liquid petroleum applications such as fiscal or
                                                                     Meters – A Case Study                                        allocation measurement is gaining world wide acceptance. Ultrasonic technology is an
                                                                                                                                  established technology but the use of this technology, for custody transfer is relatively new.


                                                                                                                                  Often users try to employ the same measurement practices that apply to turbine
                                                                                                                                technology to the Liquid Ultrasonic. .
                                                                                                                                    .
Workshop   Instrumentation Applications. Instrumentation     112     Pipe Dreams: Save Money and Improve Measurements with Would you like to have the best of both worlds in flow measurement? Here is how to save
           Flow                                                      Compact DP Flow Technology                                 money and improve the performance of your flow measurement points at the same time.
                                                                                                                                Compact DP Flowmeter designs make it possible to reduce equipment and installation
                                                                                                                                costs, eliminate potential leak points, reduce piping requirements and improve flowmeter
                                                                                                                                performance. This course will demonstrate how to take advantage of the latest innovations
                                                                                                                                in Compact DP Flowmeter technology.
Workshop   Instrumentation Applications. Instrumentation     200     40 CFR 98 Tier 4 Greenhouse Gas Reporting with Stack       The EPA's Greenhouse Gas Mandatory Reporting Requirements (GHG-MRR) drive process
           Flow                                                      Emissions Flow Meter                                       industry end-users to greatly expand their measurement and reporting capabilities. Those
                                                                                                                                choosing or required to report using "Tier 4" methodology may need to upgrade or add a
                                                                                                                                stack volumetric flow meter to their Continuous Emissions Monitoring Systems (CEMS).
                                                                                                                                This paper describes how to achieve accurate annual emissions reporting with this method
                                                                                                                                by evaluating the installation, performance, calibration and maintenance considerations for
                                                                                                                                such a flow meter.
Workshop   Instrumentation Applications. Instrumentation     226     1Impact of Impulse Line Induced Lag-time in DP Flow        Modern gas flow measurement continues to be dominated by use of the orifice plate. Effort
           Flow                                                      Measurement                                                to improve measurement performance using this technology has spanned more than 60
                                                                                                                                years. Performance is affected by many factors: distance between the measurement point
                                                                                                                                and upstream and downstream piping components, DP transmitter selection, accurate
                                                                                                                                gauging and centering of the bore hole as well as many others. Little regard is given to
                                                                                                                                impulse line diameter and length and the impact these choices make on the measurement
                                                                                                                                performance.
Workshop   Instrumentation Applications. Instrumentation     324     Arkema Refrigerant Producer Reduces Cost to Comply with    Arkema is using Emerson technology to provide reporting of greenhouse gas production at
           Flow                                                      EPA Greenhouse Gas Reporting Rule Using Micro Motion       its refrigerant production facility in Kentucky. The rule presents challenges of measurement
                                                                     Coriolis Meters with Meter Verification, AMS, and Wireless accuracy, calibration and record-keeping requirements. EPA demands tight accuracy and
                                                                     Technologies                                               Arkema desires to minimize the possibility of over-reporting production and emissions.
                                                                                                                                Initial implementation and recurring cost to comply with the regulation will be reduced
                                                                                                                                significantly.
Workshop   Instrumentation Applications. Instrumentation     333     Danisco’s Implementation of GWR in Liquid Nitrogen Reactor Liquid nitrogen tank level problems forced Danisco's Chuck Harter to assign an operator to
           Flow                                                      Enables Automation and Maximizes Process Efficiency        monitor every 4-hour batch. The goal was to prevent overfills and low levels which can
                                                                                                                                cause facility damage or shutdowns as the agitation, boiling and coating caused the current
                                                                                                                                float problems. Maintenance and safety concerns caused Danisco to turn to GWR for a
                                                                                                                                solution. Use of GWR and stilling well ensured a robust signal from tank conditions and
                                                                                                                                tank trays. GWR now gives Danisco control within 2% of span, eliminates the need for an
                                                                                                                                operator at tank side, and maximizes uptime.




                                                                                                    Page 21 of 91                                                                                              (Rev. 051010)
                                                                                       2010 Emerson Global Users Exchange
                                                                                               Sessions by Track



                                                           Session
    Type                        Track                                                             Title                                                                          Abstract
                                                              ID
Workshop   Instrumentation Applications. Instrumentation     334     Using Instrument Diagnostics to Reduce the Cost of               Today's Magnetic Flow Meters are able to provide users with advanced
           Flow                                                      Regulatory Compliance in the W&WW Industry                       diagnostic information to better manage their processes and reduce the cost of Regulatory
                                                                                                                                      Compliance. One of these diagnostics is SMART Meter Verification capability. The SMART
                                                                                                                                      Meter Verification diagnostic provides a means of verifying magmeter health without
                                                                                                                                      requiring a process shutdown or removal of the flowtube sensor. This continuously running
                                                                                                                                      diagnostic monitors critical parameters of the transmitter and flowtube sensor to provide
                                                                                                                                      users with a means of documenting the health of their magmeter system.

Workshop   Instrumentation Applications. Instrumentation     342     Improvements to Separator Control and Availability at Eli Lilly The Eli Lilly processing plant in Clinton, Indiana needed to optimize a solvent recovery
           Flow                                                      Using Micro Motion Two-Wire Coriolis                            process through greater flow measurement accuracy and reliability. But we did not have the
                                                                                                                                     power wiring available for installation of powered 4-wire flow meters. Our need was satisfied
                                                                                                                                     through the installation of a 2-wire coriolis flow meter from Micro Motion. This installation has
                                                                                                                                     lead to improved flow accuracy, better control, improved quality and reduced production
                                                                                                                                     cost. Additionally, we expect significant ongoing savings from reduced maintenance costs
                                                                                                                                     and process availability.
Workshop   Instrumentation Applications. Instrumentation     369     Cold Climate Flow Measurement: Advantages,                      Cold climate process plants can simplify their flow measurement installations by choosing a
           Flow                                                      Compromises, and Challenges of Vortex Meter                     less traditional, but more cold-weather friendly technology in Vortex Metering. For
                                                                     Implementation                                                  Consumers' Cooperative Refineries Limited (CCRL) in Regina, Saskatchewan, this is the
                                                                                                                                     metering device of choice at its current facilities, and also for a major expansion to be
                                                                                                                                     completed in 2012.
Workshop   Instrumentation Applications. Instrumentation     393     DP Flow for Dummies: Common Mistakes to Avoid                   Engineering DP Flow requires effort and experience. Mechanical and electrical components
           Flow                                                                                                                      must be put together in just the right way in order to meet the application requirements and
                                                                                                                                     avoid errors. This has resulted in common and sometimes comical mistakes. This guide is
                                                                                                                                     for anyone who wants to get more out of flow measurement by learning from the experience
                                                                                                                                     of others.
Workshop   Instrumentation Applications. Instrumentation     397     Don't Let Steam Measurement Get You Hot Under Your              Steam is a common yet challenging fluid for flow measurement. The high temperatures and
           Flow                                                      Collar                                                          potential for two-phase measurement create potential for error and challenge reliability.
                                                                                                                                     Steam measurement is also related to energy consumption. This paper compares and
                                                                                                                                     contrasts metering technologies used for steam and suggests techniques for improving and
                                                                                                                                     reducing the cost of steam measurement.
Workshop   Instrumentation Applications. Instrumentation     398     Advantages of Two Phase Flow Metering using Roxar               Using data from testing at Micro Motion's facility in Boulder, this paper presents how Roxar
           Flow                                                      Watercut Meters Together with Micro Motion Coriolis Flow        Flow Measurement and Micro Motion are developing innovative solutions for a number of
                                                                     Meters and Future Potential                                     two phase flow measurement applications which can be supplied as a standalone two phase
                                                                                                                                     metering package to a fully integrated fiscal metering station or other larger metering scope
                                                                                                                                     using a wide range of Emerson products. Applications that will benefit from an integrated
                                                                                                                                     metering solution include: Production measurement (net oil), Allocation and Fiscal
                                                                                                                                     measurement for custody transfer, loading and export metering.

Workshop   Instrumentation Applications. Instrumentation     401     Innovative Technologies for Meeting GHG Monitoring
           Flow                                                      Requirements                                                      As of Jan. 1, 2010, facilities that produce more than 25K metric tons of CO 2 e /year, must
                                                                                                                                      monitor and report GHG emissions. All petroleum refiners are required to report GHG
                                                                                                                                      emissions regardless of the amount produced. One of the more onerous stipulations of the
                                                                                                                                      rule was the decision to treat refinery fuel gas (RFG) as a Tier 3 fuel which is subject to
                                                                                                                                      more stringent requirements for measurement and calibration than either Tier 1 or 2 fuels.
                                                                                                                                      These requirements include the use of P & T compensation at each flow measumement
                                                                                                                                      point and inspection of the primary flow element at least once everythree years.

Workshop   Instrumentation Applications. Instrumentation     402     Don't Drown in Wet Gas: Wet Gas Flow Measurement with            Several types of differential pressure flowmeters are currently being used in wet gas flow
           Flow                                                      DP Flow                                                          measurement. This paper will present test data from various DP flowmeters and discuss the
                                                                                                                                      current research in wet gas flow measurement. Videos of various wet gas flows will be user
                                                                                                                                      for illustration purposes.




                                                                                                    Page 22 of 91                                                                                                  (Rev. 051010)
                                                                                           2010 Emerson Global Users Exchange
                                                                                                   Sessions by Track



                                                               Session
     Type                           Track                                                            Title                                                                       Abstract
                                                                  ID
Short Course   Instrumentation Applications. Instrumentation     425     Get Your Ducts in a Row For Better Flow Measurement         With a focus on energy management and meeting impending greenhouse gas legislation,
               Flow                                                                                                                  more plants are looking at monitoring air flow in ducts, especially those that have not been
                                                                                                                                     considered reliable flow measurement points. Duct flow measurement poses unique
                                                                                                                                     challenges due to the unique geometry and installation challenges. This paper will address
                                                                                                                                     possible solutions using DP flow technology and field calibration methods that confirm
                                                                                                                                     results.
Workshop       Instrumentation Applications. Instrumentation     460     Remote Steam Monitoring for District Energy Distribution    Enwave Energy Corporation is the largest district energy company in Canada and one of the
               Flow                                                                                                                  largest in North America. We provide low cost, environmentally-friendly heating and cooling
                                                                                                                                     to more than 140 commercial, institutional and multi residential buildings in the cities of
                                                                                                                                     Toronto and Windsor, Ontario.
                                                                                                                                     Rather than heating and cooling buildings with in-house boilers and chillers, district energy
                                                                                                                                     customers get their heating and air conditioning via underground pipe distribution networks
                                                                                                                                     that are connected to one or several large plants.
Workshop       Instrumentation Applications. Instrumentation     487     Use of Ultrasonic Flowmeters in Liquefied Natural Gas (LNG) Traditionally, LNG has been traded on the basis of long term contracts with volume
               Flow                                                      Custody Transfer Applications – New Challenges, New         measurement being done using static tank gauging. This approach has served the industry
                                                                         Solutions                                                   well, however as LNG is traded more on the basis of short term contracts, it is anticipated
                                                                                                                                     that dynamic flow measurement at the point of unloading will become more prevalent, similar
                                                                                                                                     to the custody transfer of oil shipments. Liquid ultrasonic flowmeters will be a technology of
                                                                                                                                     choice in these applications
Workshop       Instrumentation Applications. Instrumentation     520     DTE Energy maximizes Emerson’s ControlWave Micro Flow DTE Energy implements Emerson's ControlWave Micro to provide accurate gas flow
               Flow                                                      Measurement capability to increase Accuracy and reduce      measurement on multiple meter runs by auto selecting the ultrasonic meter with the best
                                                                         Operational Cost                                            flow profile. The CWM also allows DTE to determine when re- calibrations are required by
                                                                                                                                     constantly monitoring the current flow profile versus the meter's initial flow profile. This
                                                                                                                                     reduces the cost of lost gas and unneeded calibrations trips to the field. DTE has also utilize
                                                                                                                                     the full functionality of the CWM at these stations which replaces multiple devices with one
                                                                                                                                     unit leading to a result of a reduction in operational cost.
Workshop       Maintenance & Reliablity                          81      Emerson Fieldbus Device Testing – Interoperability Assured DeltaV goes beyond the Fieldbus Foundation's (FF) Interoperability Tests (ITK) in order to
                                                                                                                                     assure device/master interoperability. The FF testing assures everyone that a fieldbus
                                                                                                                                     device conforms to the FF Function Block (FB) and Transducer Block Specifications, but it
                                                                                                                                     does not test the physical layer of the device or reconcile some differences in the
                                                                                                                                     interpretations of the FF specifications. Emerson's testing includes real world scenarios and
                                                                                                                                     feedback from actual incidents.
Workshop       Maintenance & Reliablity                          128     Online vibration monitoring of boiler feedwater pumps       This presentation covers the installation and results of using an online vibration monitoring
                                                                                                                                     system. The application involves 4 boiler feedwater pumps in a 65 MW peaking plant. Plant
                                                                                                                                     burnsapprox. 15%wood and 85%coal. .
Workshop       Maintenance & Reliablity                          140     Stop Playing Maintenance Guessing Games with Radar          Guided Wave Radar transmitters with Signal Quality Metrics (SQM)diagnostics can monitor
                                                                         Level by using Advanced Signal Quality Diagnostics          for unwanted changing surface conditions or for build-up on probe.SQM give an indication of
                                                                                                                                     how good the surface signal is compared to noise and how much disturbance the device can
                                                                                                                                     handle in the tank.SQM can be assigned to transmitter variables and sent to the control
                                                                                                                                     system to trigger an alarm. These capabilities enable preventative maintenance to clean the
                                                                                                                                     probe and provide better process control by identifying abnormal surface conditions and
                                                                                                                                     preventing overfills.
Workshop       Maintenance & Reliablity                          169     Koch Nitrogen finds standardization across platforms brings Koch Nitrogen's five North American production facilities faced a familiar issue within
                                                                         efficiencies and improved productivity                      industry today regarding obsolescence of existing continuous online vibration monitoring
                                                                                                                                     platforms. Couple this fact with a lean labor force and varying experience from plant to plant,
                                                                                                                                     the five plants operated as stand alone islands in regards to mechanical asset health. We
                                                                                                                                     will examine how Koch Nitrogen methodically went about defining, evaluating, performing
                                                                                                                                     the front end engineering design(FEED), and implementation of a standardized multi plant
                                                                                                                                     online vibration monitoring platform retrofit and upgrade.




                                                                                                       Page 23 of 91                                                                                             (Rev. 051010)
                                                                        2010 Emerson Global Users Exchange
                                                                                Sessions by Track



                                            Session
     Type                           Track                                         Title                                                                          Abstract
                                               ID
Workshop       Maintenance & Reliablity       175     Weathering the Storm Using Grounding Best Practices and        Lightning provides stunning views from afar, but no one wants to be caught between its
                                                      Transient Protection for Radar Level                           energy and the ground, including radar transmitters. Various human-made and natural
                                                                                                                     events produce excess transient energy that can enter level transmitters via multiple paths.
                                                                                                                     This excess energy can damage device electronics resulting in costly field failures and
                                                                                                                     unplanned downtime. It is critical to use devices with built-in transient protection and equally
                                                                                                                     essential to follow proper grounding methods. Also special consideration must be made to
                                                                                                                     create a low resistance ground path and avoid ground loops.

Workshop       Maintenance & Reliablity       253     Alternative Energy: Online Vibration Monitoring of Three       Colbun is a private Chilean company with 1.3MW of installed capacity in Hydro and with coal
                                                      Hydroelectric Power Plants in Chile                            and GNL plants distributed across the country. In this application, it is detailed the
                                                                                                                     engineering process and results obtained when implementing predictive condition
                                                                                                                     monitoring at three hydro plants.
Workshop       Maintenance & Reliablity       254     Ormen Lange knowing that every valve will be OK tomorrow-      At Shell's North Sea Ormen Lange onshore processing plant for the subsea gas field at
                                                      how do they do it                                              Aukra, Norway, online diagnostics from more than 350 continuously monitored valves supply
                                                                                                                     critical information to operations locally at Aukra, and in addition to maintenance and
                                                                                                                     reliability personnel at the remote Shell headquarter in Kristiansund and the Fisher
                                                                                                                     representative Solberg & Andersens valve diagnostic center in Bergen. Gathering
                                                                                                                     knowledge and shearing the info is a key in the success.
Workshop       Maintenance & Reliablity       268     Soup to Nuts: Turnkey Solution Offer Full-Service Innovation   When Tesoro's Kenai refinery planned a large scale turnaround involving both valve and
                                                      for Increased Reliability                                      instrumentation work, they faced the daunting task of assembling technicians with skills to
                                                                                                                     handle this multi-faceted project. This presentation will demonstrate how Emerson built on
                                                                                                                     the knowledge of their proven turnaround process to provide a single source solution;
                                                                                                                     bringing technicians with capabilities in multiple crafts to the job. As a result of turnkey
                                                                                                                     services, Tesoro has received process efficiency benefits of improved valve performance
                                                                                                                     and increased reliability of the safety shut down system.
Workshop       Maintenance & Reliablity       272     No Time? No Problem! Chevron's Largest Turnaround              Chevron's El Segundo, CA, planned meticulously for the largest turnaround in its 125-year
                                                      Delivered Despite Shortened Schedule                           plant history. Upset conditions in an adjacent unit required plant personnel to focus their
                                                                                                                     efforts elsewhere just as the outage began. Despite the compressed schedule and
                                                                                                                     additional work, Emerson technicians were able to revise prioritization and offer multiple
                                                                                                                     paths for outage success, supporting all scope changes in the shop and field. This paper will
                                                                                                                     demonstrate how proper planning and constant communication insured on-time completion
                                                                                                                     with accurate documentation, even when timelines were condensed.

Workshop       Maintenance & Reliablity       277     Luminant's Root Cause Analysis Solves Downtime Dilemma         Luminant's Monticello high volume plant was experiencing sporadic control valve issues
                                                      and Increases Life Cycle Efficiency                            which extended downtime, costing the plant lost revenue. This paper will demonstrate how
                                                                                                                     determining the root cause of unexpected shutdowns provided a path towards repair
                                                                                                                     parameters and diagnostic techniques which can be used to make proactive maintenance
                                                                                                                     decisions. The increased life cycle efficiency and expanded duration of time between valve
                                                                                                                     related outages has allowed for more effective power generation.
Workshop       Maintenance & Reliablity       314     Creative Use of Predictive Maintenance Technologies            In 2005 Koch Fertilizer Canada embarked on a capital project to shift from a Reactive
                                                                                                                     maintenance culture to a more Predictive Maintenance strategy. Emerson's Asset
                                                                                                                     Optimization Division was selected by Koch Fertilizer Canada as the primary provider of
                                                                                                                     predictive maintenance services and products for mechanical and process equipment

                                                                                                                     Two of the technologies utilized in Koch's predictive maintenance strategy are Vibration
                                                                                                                     Analysis and Infrared Thermography. Koch's maintenance team has discovered some
                                                                                                                     relatively new applications for these technologies


Short Course   Maintenance & Reliablity       323     Rosemount Radar Master - The Ultimate Software for Radar       Learn through hands-on exercises how to conduct quality commissioning and advanced
                                                      Level Configuration and Troubleshooting                        troubleshooting of your radar by Rosemount Radar Master. You will discover Radar Master's
                                                                                                                     full potentional and learn critical functionalities to tailor your device setup. Why attend?
                                                                                                                     Because an optimally setup device is the highway to improve reliability, reduce down-time
                                                                                                                     and avoid unnecceassary maintenance! This PC software is shipped with every transmitter
                                                                                                                     and we will show you why it is recognized as users' first choice for managing Rosemount
                                                                                                                     radars.




                                                                                    Page 24 of 91                                                                                                 (Rev. 051010)
                                                                        2010 Emerson Global Users Exchange
                                                                                Sessions by Track



                                            Session
     Type                           Track                                         Title                                                                       Abstract
                                               ID
Workshop       Maintenance & Reliablity       326     COST SAVINGS REALIZED USING LARGER DIAMETER                   EVALUATION OF THE COST SAVINGS ACHIEVED USING TUBING, VALVES AND
                                                      TUBING & MECHANICAL FITTINGS VS. TRADITIONAL                  FITTINGS VS. THE TRADITONAL METHODOLOGY OF SCREWED, WELDED AND
                                                      METHODS                                                       FLANGED PIPING SYSTEMS 2" & UNDER FOR PROCESS, UTILITIY AND R&D
                                                                                                                    APLICATIONS.
Workshop       Maintenance & Reliablity       403     Reduce Cost and Risk Using Best-in-Class Calibration          By partnering with Emerson, Merck has implemented best-in-class calibration practices that
                                                      Practices                                                     have led to substantial cost savings. Other Life Sciences businesses, among them Bristol-
                                                                                                                    Myers Squibb (BMS), are adopting these same practices. This paper describes how Merck
                                                                                                                    established the validity of the instrument technology improvements and developed new best
                                                                                                                    practices for purchasing and maintaining pressure and temperature instruments. It will also
                                                                                                                    describe how BMS developed risk-based recalibration intervals.

Workshop       Maintenance & Reliablity       404     Foundation Fieldbus Error Detection & Diagnostics             Foundation Fieldbus is not a fully redundant system, and it must rely on a combination of
                                                                                                                    fault tolerance, fault isolation, and failure detection to ensure reliable operation. While
                                                                                                                    counting communications errors can be one method to identify fieldbus problems, it can be
                                                                                                                    too late. Measurement of three key fieldbus physical layer parameters can provide early
                                                                                                                    detection of problems in the fieldbus system prior to communications errors and avoid costly
                                                                                                                    unplanned disruptions in the fieldbus communications.

Short Course   Maintenance & Reliablity       420     Advanced Pressure Diagnostics in Any System Environment     Advanced pressure diagnostics provide the ability to detect abnormal process conditions,
                                                                                                                  including plugged impulse lines, entrained gas or liquid, furnace flame instability, and
                                                                                                                  distillation column flooding. Diagnosing these conditions can generate a PlantWeb alert, or
                                                                                                                  the diagnostics data can be trended and analyzed in a distributed control system. This short
                                                                                                                  course provides an overview of advanced diagnostics, and presents live demonstrations of
                                                                                                                  strategies for utilizing diagnostics with various hosts, including DeltaV, AMS Device
                                                                                                                  Manager, Wireless, and legacy control systems.
Workshop       Maintenance & Reliablity       432     How to Set Up Plugged Impulse Line Advanced Pressure        Plugging in pressure measurement impulse lines is a significant, costly, and resource-
                                                      Diagnostics using Foundation Fieldbus                       consuming problem in process plants. Foundation fieldbus pressure transmitters with
                                                                                                                  Advanced Diagnostics Suite provides the capability to detect this plugging in the impulse
                                                                                                                  lines, and notify operations or maintenance of the issue. Historically, there has been
                                                                                                                  confusion and uncertainty regarding proper configuration of plugged impulse line (PIL)
                                                                                                                  diagnostics. This workshop will provide guidance on how to best utilize this advanced
                                                                                                                  pressure diagnostics function.
Workshop       Maintenance & Reliablity       450     Orica experience with the linkage-less, non-contact         Orica Mining Services participated in the field trial program for the linkage-less, non-contact
                                                      positioner in liquid ammonia application.                   explosion proof positioner. Orica Mining Services, Kooragang Island is the second
                                                                                                                  biggest industrial Ammonium Nitrate producing site in the world. This paper will cover the
                                                                                                                  experience with this new technology.
Workshop       Maintenance & Reliablity       463     Performance Diagnostics Solves Process Instability Problem, Nexen, an operator in the Athabasca oil sands region of Alberta , was experiencing a
                                                      Yields Improved Control                                     control issue on asteam generator boiler feedwatercontrol valve. Several attempts to
                                                                                                                  correct the process oscillations through valve characteristic and control methodology
                                                                                                                  changes yielded no results. Through the implementation of Performance Diagnostics tier
                                                                                                                  on the existing DVC6000, valuable insight was provided to the operators which highlighted
                                                                                                                  the need for a change to the physical valve construction to yield a solution to the control
                                                                                                                  issue.
Short Course   Maintenance & Reliablity       505     Using Diagnostics from intelligent Motor Controls and AMS   Combining Diagnostic information from Profibus Devices with traditional Machinery
                                                      Device Manager to supplement and expand traditional         Condition Monitoring techniques to provide an holistic machinery Asset Management
                                                      Machinery Monitoring techniques                             Solution. Improving equipment performance, efficiency and reducing costs. Integration with
                                                                                                                  other Asset Management disciplines including Computerised Maintenance Management
                                                                                                                  Systems such as SAP.
Short Course   Maintenance & Reliablity       519     Get Wired into Wireless Vibration: A Primer on the Tools,   This 90 minute short course will outline the latest technology for wireless vibration
                                                      Techniques and Applications                                 monitoring along with typical applications and benefits. Topics include an introduction to
                                                                                                                  traditional and cutting edge tools for wireless vibration monitoring, measurement types and
                                                                                                                  best practices on how to implement them, basics of spectrum analysis, and typical
                                                                                                                  applications for vibration in process and asset monitoring.




                                                                                    Page 25 of 91                                                                                              (Rev. 051010)
                                                                        2010 Emerson Global Users Exchange
                                                                                Sessions by Track



                                            Session
     Type                           Track                                          Title                                                                    Abstract
                                               ID
Short Course   Maintenance & Reliablity       553     How to Create a Reliability Program                       A lot of companies strive to create a reliability for instrumentation, but how many are actually
                                                                                                                successful?This paper will cover the initial creation of an instrument reliability program and
                                                                                                                some of the successes and setbacks that occurred during implementation.The paper will
                                                                                                                also cover changes that have been implemented as a result of the instrument reliability
                                                                                                                program.
Workshop       Management                     12      Ban the Bullet Point!                                     Have you ever sat through a really boring presentation? Have you ever given one? Odds are
                                                                                                                the answer to both of those questions is YES! Making your presentation interesting,
                                                                                                                effective, and memorable can be challenging. This session will give you concrete tips and
                                                                                                                tricks to make your presentations better.
Short Course   Management                     33      How To Justify New “Smart” Automation Investments         In the current economic climate it is more important than ever to have a solid economic
                                                                                                                justification for a proposed automation investment, including those based on newer "smart"
                                                                                                                technologies. W e must be able to convince plant management of the validity of the
                                                                                                                expected returns to successfully compete for available funds. In this workshop a review of
                                                                                                                the proper way to perform financial analysis for automation investments is presented with
                                                                                                                special emphasis on "smart" devices and the integrated systems to support them.

Workshop       Management                     40      You Too are Selling - How to Sell Your Ideas Internally   We all have great ideas, and we want so see them implemented in our organizations.
                                                                                                                Whether it's to try the latetest wireless technology or completley modernize the DCS system,
                                                                                                                we know it's the right thing to do for our companies. The problem is getting the resources
                                                                                                                and money to make it happen. In this session we will walk through the basics steps of
                                                                                                                identifying hte bussiness case, developing the justification, understaning the approval
                                                                                                                process, and finally the presentation to secure the funding and resources to make your
                                                                                                                ideas a reality.
Workshop       Management                     48      Process Automation System Lifecycle Managment and         Users of process automation systems struggle with the issue of determining when the useful
                                                      Migration                                                 life of their system is over. It is equally challenging to determine when to migrate to new
                                                                                                                technology, and whether to adopt a phased approach or a vertical big bang approach. This
                                                                                                                presentation will show the current state of the industry as it relates to control system
                                                                                                                migration and lifecycle management and how it relates to best practices.


Workshop       Management                     74      The “Smart” Plant of the Future                           We see daily the rapid advances in computing and communication and the ways is which
                                                                                                                these advances have changed the way we live and work. Advances in sensor, automation,
                                                                                                                and information technology, based on these advances, have significantly changed the way
                                                                                                                process plants operate and will cause continuing change in the future, leading to what is
                                                                                                                termed "The Smart Plant". In this presentation, case studies on actual implementations,
                                                                                                                recent advances in relevant technologies and probable trends in the business environment
                                                                                                                are used to forecast likely future changes.
Short Course   Management                     120     Manufacturing Execution through Servant Leadership        To achieve 'excellence' in Manufacturing Execution you not only need to hire, promote,
                                                                                                                develop and retain top talent; but you must develop a culture where you have an organic
                                                                                                                structure of relationships, participation by the entire group, where people are the greatest
                                                                                                                assets and sources of creativity; and people embrace suffering as a tool for improvement.
                                                                                                                Servant Leadershipwill producea culture change for business sustainability.

Workshop       Management                     183     Tech Lead as Mentor - What? I’m too busy for that!        Many times, experienced engineers are tasked with tech lead roles on projects as a result of
                                                                                                                their technical proficiency. In the ideal case, all requirements are available at the start of the
                                                                                                                project and the role of tech lead is reduced to high-level design and supervisory tasks. In the
                                                                                                                real world case, project inputs can be delayed or subject to rapid change. These challenges
                                                                                                                can be used to proactively support the development of your team's skills. This workshop will
                                                                                                                present methods for developing the members of your team, while maintaining focus on
                                                                                                                project and organizational objectives.




                                                                                     Page 26 of 91                                                                                             (Rev. 051010)
                                                                      2010 Emerson Global Users Exchange
                                                                              Sessions by Track



                                          Session
    Type                          Track                                         Title                                                                        Abstract
                                             ID
Workshop   Management                       355     Business Case for the Assessment of DeltaV and Wireless in When we assess oil and gas projects today, where do we start? How do we assess if a
                                                    Oil and Gas Greenfield and Brownfield Projects             project is viable or economical? Do we focus on whether the project will be designed and
                                                                                                               constructed in the same manner and fashion as it has been done before or will we look to
                                                                                                               the future? Technology today and even future technology allows us to think laterally, to
                                                                                                               expand our minds and to dream what could be possible and achievable. With Greenfield
                                                                                                               and Brownfield projects, what decisions do we take to ensure that we operate and man
                                                                                                               these facilities in the most efficient and economic manner possible?
Workshop   Management                       467     Meridium and Emerson partnership helps improve plant       Align asset strategies with management objectives to satisfy key business drivers in your
                                                    availability and performance through enhanced asset        asset improvement initiative. Learn how a model that brings together real-time asset
                                                    management                                                 information with critical management systems while applying well-known maintenance
                                                                                                               practices produces sustainable results in asset performance.
                                                                                                                    This presentation will show how others have been incredibly successful in revitalizing
                                                                                                               their businesses by using a holistic, integrated approach to asset performance management.

Workshop   Management                       494     How an Alliance with Emerson Can Increase Value Delivered LyondellBasell Industries is one of the world's largest polymers, petrochemicals and fuels
                                                                                                              companies. Emerson is one of the world's largest industrial manufacturing solutions
                                                                                                              providers. Aligning two large and complex organizations takes some critical thinking,
                                                                                                              planning, and execution. This Paper will discuss the history of our business relationship and
                                                                                                              how it evolved into an alliance achievingmutual business wins.
Workshop   Management                       529     Human-Centered Design of Operations: From the Inside Out Often the term 'human-centered design' (HCD) is used only when companies discuss
                                                                                                              automation. However, effective HCD for operations is more than designing 'user-friendly'
                                                                                                              automation. HCD applies to the design of the operations organization and work processes,
                                                                                                              console job complexity, field operator utilization, the alarm system and DCS operator
                                                                                                              interface, the console and control room, individual and team training, and the procedure
                                                                                                              system. For all of these, HCD involves identifying the proper requirements, iterative design
                                                                                                              with end users, and effective lifecycle work processes.
Workshop   Process Optimization             57      ultivariable Control in DeltaV using LQG                  In this submission, multivariable control of the merox process at Preemraff Refinery in
                                                                                                              Lysekil Sweden is presented using the LQG algorithm programmed in DeltaV.
                                                                                                               The merox process is for elimination of sulphurous impurities in the Liquid Petroleum Gas
                                                                                                              (LPG) stream from the refinery?s fluid catalytic cracker. The process comprises a counter
                                                                                                              current amine tower and caustic wash vessel, extraction tower, separation and filtration unit.
                                                                                                               The whole unit is liquid filled. Control valves on liquid streams in the process control flow,
                                                                                                              pressure and liquid interface level.
Workshop   Process Optimization             84      Sustaining and Extending Advanced Control Value in an     Goodyear had previously completed an Advanced Process Control (APC) project on a
                                                    Operating Plant                                           distillation column in its C5 refining unit which resulted in significant savings. This project
                                                                                                              was designed and led by Emerson consultants with Goodyear engineers working/training
                                                                                                              under the consultants.
                                                                                                              In continuation of the unit optimization effort, an APC multicolumn project has been
                                                                                                              completed with Goodyear engineers leading and implementing the project. This paper will
                                                                                                              discuss the APC technology implemented in the second project, the resulting benefits, and
                                                                                                              also the ongoing efforts to maintain the APC models

Workshop   Process Optimization             108     PredictPro Reduces Energy Consumption and Emissions at        A control loop audit at MOL's Algyo gas plant highlighted the opportunity for optimisation of
                                                    MOL, Algyo Gas Plant                                          the distillation column controls using advanced control strategies which can cope with feed
                                                                                                                  and product quality spec changes.

                                                                                                                  MOL selected the advanced control tools embedded in their DeltaV DCS, PredictPro. The
                                                                                                                  implemented solution included a combination of advanced regulatory control, model
                                                                                                                  predictive control and inferential analyses of product qualities.

                                                                                                                  The project resulted in a US$ 1.7million saving in fuel usage, with associated reduction in
                                                                                                                  CO2 emissions, and improved on-spec production.




                                                                                  Page 27 of 91                                                                                               (Rev. 051010)
                                                                          2010 Emerson Global Users Exchange
                                                                                  Sessions by Track



                                              Session
     Type                             Track                                         Title                                                                       Abstract
                                                 ID
Workshop       Process Optimization             134     Solving Loop Interactions in a New LNG Train Using          Emerson consultants assisted startup of a large LNG train on PlantWeb. We quickly fixed
                                                        Combined Emerson Tools                                      hundreds of loop problems by using simultaneously Emerson tools embedded in DeltaV or
                                                                                                                    added on to an Application Station. Examples are from various process units: Utilities,
                                                                                                                    Fractionation, Sulfur Recovery, and Cryogenic. We emphasize interactions between the
                                                                                                                    levels, flows, pressures, and temperatures and their decoupling by the Lambda Tuning
                                                                                                                    method. The plant saved several days of startup time and also saw improvements in
                                                                                                                    product quality, efficiency, and stability.
Workshop       Process Optimization             155     Tête-à-tête with the Operators, A DeltaV Messaging System   DeltaV graphics and alarms aren't the only way to communicate with an operator. Come see
                                                        that Works                                                  how a messaging system provides a way to get supervisor permission, prod operators to
                                                                                                                    take action, provide recurring reminders, and give automation progress updates no matter
                                                                                                                    what screen is being viewed. For large-scale applications, this system can dramatically
                                                                                                                    improve communication and conduct of operations. Presentation concentrates on
                                                                                                                    implementation of this system.
Workshop       Process Optimization             167     Batch Process Analytics (PA) – An In Depth Update
                                                                                                                      In-depth look at the needs and limitations of on-line batch Process Analytics (PA). The
                                                                                                                    practical and useful findings from the work of Lubrizol and Emerson for advancing on-line
                                                                                                                    batch PA following completion of a successful field trial. Principles of multivariate analysis
                                                                                                                    will be shown as well as a web interface for on-line PA. Advantages of PA for addressing
                                                                                                                    the limitations of traditional monitoring will be discussed. Additional process insight provided
                                                                                                                    by PA as well as having real time batch product quality capability will be shown.

Workshop       Process Optimization             171     Making Operations Predictable Through Automation; The       Poor plant process control resulting in excessive process variability can cause equipment
                                                        True Cost, Causes and Cures of Process Variability          reliability problems as well as poor product quality and excessive operating costs. These
                                                                                                                    problems can be due to external disturbances, or the performance of measurements,
                                                                                                                    valves, or control algorithms. Identifying the cause and economically justifying the
                                                                                                                    automation investments required to correct these problems and decrease process variability
                                                                                                                    is the subject of this presentation.
Workshop       Process Optimization             173     Quick Hit Financial Benefit of SmartProcess Application     The Oil Refining industry is faced with a challenging economic environment which has led to
                                                                                                                    a high emphasis on cost reduction and cash flow management. Investment in costly
                                                                                                                    strategic initiatives does not fit the economic model to generate a positive cash flow in the
                                                                                                                    near term. Implementation of a SmartProcess Distillation solution provides the opportunity
                                                                                                                    to invest in improving process yield and energy on a smaller scale. With these strategically
                                                                                                                    targeted APC applications, cash payout can be realized in months without a complicated
                                                                                                                    infrastructure, interface or additional console displays.
Short Course   Process Optimization             204     Interactive Exploration of Process Control Improvement      The minimization of peak and integrated errors from disturbances are important for key
                                                                                                                    performance indicators (KPI) such as quality, yield, on-stream time, and environmental
                                                                                                                    costs. This short course will show how controller tuning, cascade control, the PIDPLUS
                                                                                                                    algorithm, wireless refresh time, analyzer sample delay, sensor lag, transmitter damping,
                                                                                                                    and control valve sensitivity affect the errors from disturbances and KPI. The attendees will
                                                                                                                    be able to explore process control opportunities via an operator interface to a web
                                                                                                                    accessible virtual plant designed to quantify improvements for loops and unit operations.

Workshop       Process Optimization             228     APC – Where to Use It                                       Companies in all types of industries have reported remarkable benefits from implementing
                                                                                                                    Advanced Process Control (APC) on a wide variety of processes, from bio reactors to
                                                                                                                    refinery crude columns. With the advent of embedded DeltaV APC tools, the cost for
                                                                                                                    implementing and supporting APC applications has never been less. But many sites still
                                                                                                                    struggle to take advantage of the APC capability built-in to DeltaV. It's often difficult to
                                                                                                                    identify where the technology might be used in a high-impact way. This session will address
                                                                                                                    the question of where to look to find killer APC applications.




                                                                                      Page 28 of 91                                                                                              (Rev. 051010)
                                                                      2010 Emerson Global Users Exchange
                                                                              Sessions by Track



                                          Session
    Type                          Track                                         Title                                                                         Abstract
                                             ID
Workshop   Process Optimization             237     Temperature Expert Control System for a Copper Smelter         The copper smelter in Southern Peru is one of the World's largest. It smelts concentrate
                                                    Furnace at Southern Copper Corporation (SCC)                   produced from Peruvian ores and annual capacity is rated at 330,000 metric tons of cast
                                                                                                                   copper products.
                                                                                                                   The smelter furnace temperature control is critical in the plant process and directly related to
                                                                                                                   the throughput. With the implementation of advanced control of this parameter, it was
                                                                                                                   possible to perform corrections of the ISA furnace's operation in real time and with only one
                                                                                                                   controller.

Workshop   Process Optimization             240     Advanced Process Control Strategy with MPC applied to the      Minera Los Pelambres is one of the top ten copper mines in the World and the fourth in
                                                    Crashing Process in the Copper Extraction                      Chile. Its reserves are around 2.2M of copper tones and its production is 339 T/year.
                                                                                                                   In this application, it is described the migration from a separate existing expert system to
                                                                                                                   one integrated with the plant's control system DeltaV adding APC modules. This involved
                                                                                                                   two stages: the first one with traditional PID modules and the second one with MPC for
                                                                                                                   regulatory control of the SAG mill and the ball mills.

Workshop   Process Optimization             288     Interesting and Useful Features of the DeltaV PID, Ratio and   This presentation will explain features of the DeltaV control function block including variable
                                                    Bias/Gain Control Block                                        tuning, error squared PID algorithm, two degrees of freedom PID form and structure, gain
                                                                                                                   scheduling, dynamic reset limit, output signal characterization and anti-reset windup
                                                                                                                   settings. In addition, the use and settings of the Ratio and Bias/Gain function blocks with
                                                                                                                   the PID algorithm will be explained.
Workshop   Process Optimization             341     Using PredictPro’s Optimizer to Maximize Profit from a Real-   PredictPro has been used extensively in various industries to solve difficult control
                                                    Time Electrical Purchase Agreement                             problems. In this paper, we show how PredictPro's Optimizer was used to solve a difficult
                                                                                                                   optimization problem. Used as the core of an Energy Management System in a multi-
                                                                                                                   boiler Co-Generation Plant, the PredictPro Optimizer uses real-time economic and process
                                                                                                                   information to manage steam generation and turbine loading to maximize the profit available
                                                                                                                   from exporting electrical power. We show how to programmatically manipulate the
                                                                                                                   Optimizer's parameters to respond to real-time changes in economic objectives.

Workshop   Process Optimization             437     Model Predictive Control for Integrating Processes             Model-Predictive Control (MPC) is synonymous with advanced process control (APC).
                                                                                                                   DeltaV Predict and PredictPro have been used successfully for many APC projects. But the
                                                                                                                   applications tend to involve self-regulating processes. Another family of processes are
                                                                                                                   integrating processes, typified by level control. MPC can be applied to integrating processes,
                                                                                                                   but there are special considerations. This presentation looks at the special issues for using
                                                                                                                   MPC to control integrating processes. A real worldapplication involving hoppers and
                                                                                                                   conveyors is used as an example.
Workshop   Process Optimization             457     Model Predictive Control: Not Just for Large Systems           A Model Predictive Controller with one control variable and one manipulated variable was
                                                                                                                   implemented at Ascend Performance Materials using DeltaV's MPCPro block. This controller
                                                                                                                   allowed Ascend to significantly reduce the variability of a critical control parameter of a
                                                                                                                   reactor product stream, making it possible to operate closer to process constraints, and
                                                                                                                   saving almost 7% of the energy required to feed reactants to the unit.
Workshop   Process Optimization             495     Food Plant Waste Stream Turned to Profit                       A major North American potato product producer has found a way to generate profit from its
                                                                                                                   waste stream, and Emerson products and services are helping. The processes used to
                                                                                                                   make french fries and other products from raw potatoes generate a waste stream of peels,
                                                                                                                   cuttings, and waste water containing starch. This waste is now collected in covered
                                                                                                                   anaerobic lagoons at the plants, from which biogas is collected. This biogas is used as a
                                                                                                                   low cost fuel source for the power boilers at these sites and Emerson control products and
                                                                                                                   solutions are optimizing the use of this waste fuel.
Workshop   Process Optimization             506     Increase Plant Profits and Savings through Optimum             Process controls can significantly decrease process variability increasing savings and
                                                    Process Controls                                               profits. Topics include typical process controls oversights, control performance improving
                                                                                                                   tips, control valve impact, instrumentation issues, comprehensive plant tuning. Examples
                                                                                                                   include a chemical plant boiler house; pH control in a pharmaceutical thermal-oxidation; a
                                                                                                                   pulp and paper plant; pipeline control




                                                                                  Page 29 of 91                                                                                                 (Rev. 051010)
                                                                                 2010 Emerson Global Users Exchange
                                                                                         Sessions by Track



                                                      Session
    Type                          Track                                                    Title                                                                         Abstract
                                                         ID
Workshop   Process Optimization                         528     Extending the Power of InSight Beyond DeltaV                 DeltaV InSight has proven to be a valuable tool to monitor control performance within the
                                                                                                                             DeltaV system. This paper discusses how the application of InSight was extended beyond
                                                                                                                             a DeltaV system to include loops in a legacy Honeywell DCS. We will share specific
                                                                                                                             application details on how DeltaV InSight was configured and incorporated into existing
                                                                                                                             maintenance practices, demonstrating how DeltaV InSight can be used with virtually any
                                                                                                                             DCS that supports open communication protocols.
Workshop   Process Optimization                         562     Hydrocracker Temperature Optimization Fieldbus Project       This paper is a review Valero McKee Refinery Hydrocracker Unit (HCU) Temperature
                                                                Implementation                                               Profile upgrade.

                                                                                                                                Poor temperature measurement makes it possible to have the reaction initiate in localized
                                                                                                                             sections of the catalyst bed. Even during normal operation, the process can develop uneven
                                                                                                                             flow through the catalyst bed that can produce undetected hot spots reduce yields and lead
                                                                                                                             to early catalyst replacement or have more severe consequences affecting the HCU. Using
                                                                                                                             RMT's 848T multipoint temperature transmitter, solved additional for point solution with
                                                                                                                             significant cost savings.
Workshop   Project Management and Engineering Tools     29      Optimization of Instrumentation and Process Control System   Instrumentation and control system pre-commissioning is the last piece of puzzle to be fit in
                                                                Pre-commissioning                                            place before declaring that a particular process unit of a new project is ready for system
                                                                                                                             commissioning. Float in project schedule is often consumed by other major disciplines like
                                                                                                                             piping and electrical which lead to extreme force in shortening the time allocated for
                                                                                                                             instrumentation and control system construction and pre-commissioning. Based on that
                                                                                                                             strong pre-commissioning execution plan shall be created at very early stage of the project.

Workshop   Project Management and Engineering Tools     58      Reducing the Engineering Cost                                In principle, engineering has not changed that much over the years. New and more complex
                                                                                                                             technologies have been introduced on the process side and also the control system side.
                                                                                                                               Still, many similar tasks, such as specifications, wiring, and layout, must be performed.
                                                                                                                             From the business viewpoint, the pressure grows to reduce the cost to engineer and build
                                                                                                                             as well as to reduce the time to market in this competitive environment.




Workshop   Project Management and Engineering Tools     88      A Case Study showing The Good, The Bad and The Ugly of       Why should you select an Automation vendor before you start Front End Engineering
                                                                selecting your vendor before FEED                            Design ?

                                                                                                                                The process, benefits and things to watch for in selecting early will be explored using a real
                                                                                                                             life BP case study.
Workshop   Project Management and Engineering Tools     91      CCTV: Not just for cops and robbers                          CCTV is traditionally thought of as a security tool for remotely monitoring of an area to
                                                                                                                             insure that only authorized personnel are in and about that area, but in the process industry
                                                                                                                             CCTV can perform a larger role than that of a watchdog tool. It can provide operations with a
                                                                                                                             remote view of the process area and equipment. It can also provide a safe way of
                                                                                                                             evaluating the unit in an upset situation allowing operations to examine outside conditions
                                                                                                                             before ventuuring into them.
Workshop   Project Management and Engineering Tools     111     Make the Most of Lessons Learned - Tools and Techniques      Capturing lessons learned can be a difficult and neglected aspect of project management.
                                                                                                                             But, if done properly, the benefits for future projects can be significant.

                                                                                                                             Every project provides new opportunities and challenges. How these situations are planned
                                                                                                                             for, recognized and responded to, along with their project impacts (positive and negative)
                                                                                                                             are lessons that can be captured for future projects. This workshop will discuss effective
                                                                                                                             techniques and methods for capturing, documenting, storing and retrieving lessons learned
                                                                                                                             for the benefit of future similar projects.
Workshop   Project Management and Engineering Tools     149     Streamlined DeltaV Change and Testing Method                 Our previous method of making and testing changes to our DeltaV systems, was very labor
                                                                                                                             and material intensive. This method has been replaced with a partial electronic method for
                                                                                                                             changes and standard test scripts for testing.




                                                                                             Page 30 of 91                                                                                                 (Rev. 051010)
                                                                                      2010 Emerson Global Users Exchange
                                                                                              Sessions by Track



                                                          Session
     Type                         Track                                                         Title                                                                       Abstract
                                                             ID
Workshop       Project Management and Engineering Tools     158     Best Practices for a Smooth Engineering and Successful        The presenter will share Best Practices experiencesof engineering a fieldbus project, how
                                                                    Startup of Foundation Fieldbus Projects                       best to make use of the Fieldbus technology and its products, importance of training during
                                                                                                                                  project phases, educating thefield installation contractor to do correctly the segment
                                                                                                                                  checkout work. He will explain how engineering work such as AMSset up,preliminary Alerts
                                                                                                                                  set up, Valve link software set up help to achieve smooth plant start up with examples from
                                                                                                                                  successfully commissionedprojects such asATCII and PDH in Thailand, QG2 project and
                                                                                                                                  Fujian Refining and Ethylene in China
Workshop       Project Management and Engineering Tools     185     So why would an EPC want to ever use CHARMS?                  We've heard the marketing spin, but what would DeltaV v11 and Electronic Marshalling
                                                                                                                                  mean to a real project? A team from Emerson and Fluor have examined the impact that
                                                                                                                                  DeltaV v11 would have made to a recent project.The teamwill present their conclusions
                                                                                                                                  which included cost savings, reduction of the impact of late changes, and a robust single-
                                                                                                                                  pass project executionmethodology. If you want to understand what CHARMs might mean
                                                                                                                                  for you and your project then this workshop will give you some real-life insights.

Workshop       Project Management and Engineering Tools     262     Selecting the right Foundation Fieldbus device –              When selecting FF devices which are not manufactured by the HOST vendor, the best
                                                                    Interoperability or Integration?                              choice is to use devices and components which are registered with the Fieldbus Foundation.
                                                                                                                                    This will ensure a basic "interoperability" which ensures that the device communicates with
                                                                                                                                  the HOST system and other devices per the FF Specifications. It does not mean that it will
                                                                                                                                  perform as advertized or expected. Will it work as expected? What features are available,
                                                                                                                                  which are needed? Are the displays and interfaces easy to see and use? What are the
                                                                                                                                  quirks and "gotchas"?
Workshop       Project Management and Engineering Tools     267     Proven Process, Streamlined Startup: Lucite International’s   Lucite International's Singapore facility, a large chemical complex, required thousands of
                                                                    Smart Commissioning Project                                   hours of manual labor for proper quality control inspections and documentation during
                                                                                                                                  construction and commissioning of instrumentation and electrical components. Emerson's
                                                                                                                                  Smart Commissioning Services were employed to help facilitate the process, saving the
                                                                                                                                  plant $335,000 in typical costs.
Short Course   Project Management and Engineering Tools     282     Comparative study between DeltaV traditional architecture     The presentation willsummarizea comparative study on the deployment of 16AI on a Delta V
                                                                    and Electronic Marshalling                                    control system using two architectures: With traditional IO (one AI card) and with new
                                                                                                                                  DeltaV Electronic Marshalling IO (CHARM).

Workshop       Project Management and Engineering Tools     335     Control systems project execution - an unconventional
                                                                    approach                                                       EPC is a mature industry and the project execution work processes we follow are more or
                                                                                                                                  less mature. Following this conventional approach to execute a project allows us to go
                                                                                                                                  through the engineering phase somewhat placidly, but many a times it disallows us from
                                                                                                                                  optimizing for improvement. We all know the issues that are troublesome and we all know
                                                                                                                                  that these issues repeat themselves project after project. This presentation brings out some
                                                                                                                                  ideas that do not conform to the orthodox way of executing the engineering phase of a
                                                                                                                                  project.
Workshop       Project Management and Engineering Tools     348     Evolving Organizational Structures of Large Design Teams      Managing large design teams in today's business environment requires team adaptability to
                                                                                                                                  meet the needs of changing project requirements. Changing conditions pose continuing
                                                                                                                                  challenges to team effectiveness and efficiency. The organizational structure of these
                                                                                                                                  teams must evolve and adapt throughout the life of a project to overcome these challenges.
                                                                                                                                   Presentation includes obstacles to managing a large design team through the phases of a
                                                                                                                                  project and presents an evolutionary timeline of a typical project team. It provides a
                                                                                                                                  template for a large design team over the life of a project.

Workshop       Project Management and Engineering Tools     374     Harnessing Your Experts’ Knowledge for Sustainable            More than ever, companies realize their competitive advantage comes from what they know.
                                                                    Competitive Advantage                                          By flexing their intellectual muscle, businesses become more efficient, avoid repeating
                                                                                                                                  mistakes, and encourage innovation. Expertise exists in your company, so how can your
                                                                                                                                  learners apply what your experts already know? And how can you pass along practical know-
                                                                                                                                  how from your experts before they leave or retire? In this workshop, we will discuss some
                                                                                                                                  barriers to sharing knowledge, and we will discuss practical tools and approaches to
                                                                                                                                  cultivate sharing within your organization.




                                                                                                  Page 31 of 91                                                                                             (Rev. 051010)
                                                                                  2010 Emerson Global Users Exchange
                                                                                          Sessions by Track



                                                      Session
    Type                      Track                                                          Title                                                                       Abstract
                                                         ID
Workshop   Project Management and Engineering Tools     412     AS-I Integrating Low-Cost Discretes Using a Low-Cost           Actuator Sensor Interface, or AS-Interface or AS-I Bus, is an open data exchange industrial
                                                                Method                                                         communication network between discrete input/output devices and automation controllers. It
                                                                                                                               is a highly distributed network for standard discrete I/O; it is a solution supported by 300
                                                                                                                               vendors; and it is the only network with connections to all major PLC suppliers. This paper
                                                                                                                               will describe the use of low cost AS-I products (Masters, Infrastructure, and Slaves) to
                                                                                                                               interface low cost discrete I/O.
Workshop   Project Management and Engineering Tools     421     System Integrators Scope of Work                               Whether you work for EPC Firm or an owner's organization most scope disagreements
                                                                                                                               occur when one party assumes that the other party will perform a specific scope of work.
                                                                                                                               Sometimes we assume a project will be executed similar to another or we don't know what
                                                                                                                               scope is who's scope and assume. This workshop is intended to outline a typical system
                                                                                                                               integrator scope of work.
Workshop   Project Management and Engineering Tools     488     Leveraging existing code - A boon or a burden?                 As the DeltaVindustry matures, there is a growing welath of existing automation code that
                                                                                                                               may beused for new captial projects. Leveraging existing code appropriatelywill reduce
                                                                                                                               captial cost and shrink development time.However, leveraging the code in an inappropriate
                                                                                                                               way can lead to missed deadlines and unexpected expenses. This workshop will review and
                                                                                                                               contrastthe DeltaV code leveragedforthree (3) capital projects in the pharmaceutical industry.

Workshop   Project Management and Engineering Tools     544     How Range Fuels Partnered With Emerson and Benefitted     Building a new biofuels conversion plant can be risky business. Decisions regarding the
                                                                From the Main Automation Contractor Approach to Project   process technology, feedstock availability, plant location, process equipment fabricators, etc.
                                                                Execution                                                 are only part of the equation. What about the automation system? This presentation will
                                                                                                                          cover how Range Fuels partnered with Emerson and benefitted from the Main Automation
                                                                                                                          Contractor approach to executing the project.
Workshop   Project Management and Engineering Tools     551     Conducting a Full Field Simulation Project in the US Mid- Norwest, a consulting firm to the energy, mining, and natural resources sectors, has
                                                                Continent to Improve Field Recovery                       extensive experience in Coalbed Methane (CBM), a form of natural gas extracted from coal
                                                                                                                          beds. This abstract examines how Norwest used the Roxar Tempest MORE reservoir
                                                                                                                          simulator for a full field simulation project in the U.S mid-continent. The resulting simulation
                                                                                                                          model was used to optimize the timing and sequence of infill drilling, as well as the
                                                                                                                          conversion of existing wells to air injection. Current estimates based on the simulation model
                                                                                                                          indicate field recovery will more than double .
Workshop   Project Management and Engineering Tools     558     SBM Offshore Reduces Risk and Costs Through Partnership SBM Offshore is a pioneer in the offshore oil and gas industry. The partnership with
                                                                                                                          Emerson has reduced risk and costs on 2 FPSO projects deployed from SBM's Monaco
                                                                                                                          office. SBM named Emerson the instrumentation, control valves and regulators supplier on
                                                                                                                          the projects. An integrated team of SBM and Emerson people were located in Monaco,
                                                                                                                          including a project manager.
Workshop   Safety Instrumented Systems                  64      “SIS Final Element Diagnostics Including The SOV, Using A Traditionally Safety instrumented Systems are functionally tested during turnarounds on
                                                                Digital Valve Controller”                                 yearly or once in two year basis. Present economies and pressure to maximize production
                                                                                                                          are forcing process industries to extend shutdown period to 3 or in some cases to 5 years.
                                                                                                                          This puts onus on Final control element, including SOV, which remains untested for longer
                                                                                                                          time.
Workshop   Safety Instrumented Systems                  92      What Now? More Standards for Safety and Regulatory        Just when a majority of industrial manufacturers were getting the hang of the global safety
                                                                Compliance                                                requirements, professional societies are developing even more guidance documents for
                                                                                                                          Burner Management System (BMS) applications. Industry experts suggest these
                                                                                                                          "clarifications" are necessary as NFPA 85 dictates BMS design and operation from a
                                                                                                                          prescriptive viewpoint. ANSI/ISA TR 5 provides guidance on expected performance and API
                                                                                                                          556 from an experience point of view. However, many end-users fear it will become a hard
                                                                                                                          line compliance issue with OSHA and Local Jurisdictional Authorities.

Workshop   Safety Instrumented Systems                  93      How to Avoid Shooting Yourself in the Foot with Your SIS?      The use of three transmitters (two SIS and one BPCS)is utilized for the generation of
                                                                You can minimize the risk of creating a safety demand (SIS     deviation alarming. This alarming is set up so that if the BPCS data becomes widely
                                                                or PSV) from BPCS single loop failures with the use of well-   different from the SIS transmitters, the controller(s) will be placed into MANUAL, and
                                                                designed instrumentation, deviation alarming and backup        alarmed. The operator will then have the opportunity to select which SIS transmitter data
                                                                PID loop control.                                              value on which to control until the BPCS transmitter can be repaired.




                                                                                               Page 32 of 91                                                                                              (Rev. 051010)
                                                                     2010 Emerson Global Users Exchange
                                                                             Sessions by Track



                                         Session
    Type                      Track                                             Title                                                                      Abstract
                                            ID
Workshop   Safety Instrumented Systems     107     DeltaV SIS in the Heat Of The Desert                       There are a number of new technologies available to Oil Producers but ensuring we gain
                                                                                                              tangible benefits require correct evaluation and selection. A Major Oil producer in the Middle
                                                                                                              East identified a number of new technologies and choose to evaluate these, to ensure
                                                                                                              operational benefits and capital savings could be achieved. The major oil producer saw
                                                                                                              future benefits in DeltaV SIS, Intelligent valve positioners and wireless technologies. This
                                                                                                              presentation will present the technology evaluation and the benefits that the Major Oil
                                                                                                              Producer believes it can achieve.
Workshop   Safety Instrumented Systems     174     On-line SIS testing Using AMS                              Traditional methods for on-line testing of field transmitters for safety systems make little use
                                                                                                              of the capabilities of modern smart transmitters and also require considerable coordination
                                                                                                              with operations. As more Safety Instrumented Systems are implemented in the refinery the
                                                                                                              increase in demand to perform the labor intensive traditional methods presents challenges
                                                                                                              on managing the qualified resources. Now with AMS, much of the labor has been removed
                                                                                                              from the testing and the automated documentation makes it easy to better understand
                                                                                                              failure modes and frequency to further improve safety.
Workshop   Safety Instrumented Systems     184     Burner Management – A straightforward approach using       If you are considering a new Burner Management System, there are many reasons a DeltaV
                                                   DeltaV SIS for typical systems.                            SIS should be explored. The DeltaV SIS system has many advantages including scalability,
                                                                                                              utilization of smart instruments, integrated Control and BMS Systems, and embedded safety
                                                                                                              functions.
                                                                                                                Like many other vendors, DeltaV SIS can handle simple standard logic diagrams; however,
                                                                                                              advanced function blocks allow your application to utilize an advanced state-based
                                                                                                              engineering approach. This approach helps to simplify the design, configuration and testing -
                                                                                                               resulting in time savings and reduced complexity.
Workshop   Safety Instrumented Systems     193     Embracing new technology. ..Replacing Triconex with DeltaV A major producer of nitrogen products needed to replace an aging TMR Triconex safety trip
                                                   SIS.                                                       system. By evaluating new technologies, the process manufacturer realized the benefits that
                                                                                                              DeltaV SIS can offer; however, since the entire plant complex is dependent on the trip
                                                                                                              system that needed replacement, this project was critical to keep the plant running. This
                                                                                                              high profile upgrade project was successfully completed by using smart device diagnostics,
                                                                                                              leveraging the integrated BPCS and SIS architecture, and relying on Emerson's safety-
                                                                                                              certified engineering services.
Workshop   Safety Instrumented Systems     203     RockTenn’s BMS Project Uses DeltaV SIS                     Replacing an aged BMS system for boilers? Should you implement an SIS? RockTenn
                                                                                                              needed to replace an aged and unreliable BMS system for their boilers. To comply with
                                                                                                              industry standards and take advantage of diagnostic information, RockTenn successfully
                                                                                                              completed this project using the DeltaV SIS process safety system and integrating it with the
                                                                                                              existing DeltaV and AMS systems. Emerson provided local safety expertise and engineering
                                                                                                              services to help ensure that compliance requirements were meet.

Workshop   Safety Instrumented Systems     234     F&G solutions with DeltaV SIS                                 Since the release of DeltaV SIS Emerson has been steadily increasing its abilities to provide
                                                                                                                 a F&G solution as it is required by the industry. Through recent developments Emerson is
                                                                                                                 now even more capable of providing a full DeltaV SIS based F&G solution. This workshop
                                                                                                                 will touch on the improvements made. These improvements vary from new possibilities for
                                                                                                                 applying DeltaV SIS to F&G applications, as well as improved libraries for F&G HMI.

Workshop   Safety Instrumented Systems     257     Build on your Safety Instrument System knowledge to           When designing safety instrument systems, failure modes initiated by the application itself
                                                   achieve best practice for application safety aspects in       need special consideration. For level measurements this is particularly important due to high
                                                   IEC61511 level safety                                         application dependency. This session will address different types of application initiated
                                                                                                                 failure modes, how these can be avoided by careful selection of instrument options utilizing
                                                                                                                 simple best practices, and how automatic diagnostics features can reduce the number of
                                                                                                                 undetected dangerous failures.
Workshop   Safety Instrumented Systems     315     Usign Syncade Workflow and AMS Device Manager for SIF         Work process and documentation requirements for IEC 61511 compliant safety systems
                                                   Proof Testing on a DeltaV SMART SIS System                    require more diligence than what normally occurs during checkout of a BPCS system. In
                                                                                                                 order to establish a set workflow that guides the tester through the steps, Syncade in
                                                                                                                 conjunction with DeltaV SIS, AMS and the QuickCheck Snap-On provides an architecture
                                                                                                                 that guides the tester through a defined workflow, documenting each step.




                                                                                   Page 33 of 91                                                                                            (Rev. 051010)
                                                                         2010 Emerson Global Users Exchange
                                                                                 Sessions by Track



                                             Session
     Type                           Track                                          Title                                                                         Abstract
                                                ID
Workshop       Safety Instrumented Systems     316     Safety Requirements Specifications - Guidelines and           Development of Safety Requirements Specifications (SRS) is an essential and extremely
                                                       Common Mistakes                                               critical step in the safety lifecycle that presents challenges in how to convey sufficient
                                                                                                                     information to the team that is designing, constructing, commissioning, and installing the
                                                                                                                     specified safety systems. The fundamental problem is not following good specification
                                                                                                                     practices and considering how the SRS documentation will be used, once created, resulting
                                                                                                                     in poorly prepared specifications. This presentation presents best practices for preparing a
                                                                                                                     SRS with a specific emphasis on DeltaV SIS based systems.
Workshop       Safety Instrumented Systems     489     Data Integration Between BPCS and SIS Offer Significant       Compliance best practices based on ISA 84/IEC 61511 requires process manufacturers to
                                                       Engineering Savings at Novus                                  evaluate the need for safety systems in all areas of the plant. Novus addressed the
                                                                                                                     challenge of replacing an aged panel-based waste stream interlock system by implementing
                                                                                                                     an SIS. Using an integrated control and safety system (ICSS), Novus was able to comply
                                                                                                                     with regulations, reduce engineering effort, provide fast troubleshooting, and allow easy
                                                                                                                     access to safety information at the operator interface.

Workshop       Safety Instrumented Systems     499     Hydraulic Partical Stroke and Diagnostics - Improve Safety    High Pressure hydraulic partial stroke and diagnostics systems, offer significant
                                                       and Reliability of your High Pressure System using HPSD       opportunities to collect and analyze the data on remote valves and actuators, thereby
                                                                                                                     improving reliability and safety of the system while meeting the requirements of SIS.
                                                                                                                     Intelligent diagnostic devices in the low pressure pneumatic segments such as the DVC
                                                                                                                     meet these market needs. Emerson Process Management, Valve Automation introduces a
                                                                                                                     new product in the high pressure hydraulic segment meeting the industry requirements for a
                                                                                                                     High Pressure Partial Stroke and Diagnostic (HPSD) system.
Workshop       Valve Applications              38      Valve Testing Standards Result in Higher Performance          International Paper's IEPM standards help IP recognize Fisher's superior products and
                                                                                                                     services through stringent testing and proven performance. Their stringent guidelines
                                                                                                                     improve mill performance and reduce downtime.
Workshop       Valve Applications              49      How and what instruments to size for valve performance        When valve performance requirements typically include stroking speeds. But how do you
                                                                                                                     get from those requirements to the proper instruments needed. You know a positioner is
                                                                                                                     involved but is that enough. In many cases that is not enough, volume booster are used in
                                                                                                                     conjunction with a positioner on a throttling control valve to increase stroking speed. These
                                                                                                                     boosters deliver high-volume output for fast stroking when large, rapid input signal changes
                                                                                                                     occur. But there is more, when a filter regulator is used they also must accounted for.

Workshop       Valve Applications              56      Unique application, control valve solutions, and system       Thisworkshop will explain the unique requirementsof theresidual heat removal application in
                                                       testing requirments for the residual hear removal system in   a Westinghouse AP1000 nuclear plant, whichis one of the most critical control valves
                                                       the Westinghouse AP1000 next generation Nuclear plant.        applications in passive safety system. The custom control valve solutionwasdesigned
                                                                                                                     specifically for this application by the Fisher Division of Emerson Process Management.The
                                                                                                                     results ofa full scale system test that was done in the Emerson Innovation Center for Fisher
                                                                                                                     Technology will be presented.
Short Course   Valve Applications              102     Improve Ethylene Conversion and Overall Plant Reliability     Within an ethylene plant, there are many ways to improve ethylene conversion, optimize
                                                                                                                     energy usage, use predictive maintenance, increase reliability, and improve safety. Large
                                                                                                                     ethylene plants can have more than 800 control valves in them. This short course will walk
                                                                                                                     through the critical valve applications within the different process units of the plant. It will
                                                                                                                     highlight the valve application, issues/challenges, and the solution.

Workshop       Valve Applications              116     How Flow Lab Capabilities Bring Better Understanding Of       Flow labs can offer real life testing situations which enhance the understanding and
                                                       Series Component Interaction That Results In Better           modeling for control valve applications. One such example of this capability is backpressure
                                                       Modeling Techniques To Quiet Real Life Applications.          devices and series restriction interactions. Flow lab test results confirmed the sizing model,
                                                                                                                     which helped to resolve an existing, multiple component installation that was operating at
                                                                                                                     unacceptable noise levels at a steam heating pressure reducing station. The sizing
                                                                                                                     calculations allowed for proper final control element selection to reduce the overall noise to
                                                                                                                     acceptable levels.




                                                                                     Page 34 of 91                                                                                                 (Rev. 051010)
                                                                        2010 Emerson Global Users Exchange
                                                                                Sessions by Track



                                            Session
     Type                           Track                                          Title                                                                         Abstract
                                               ID
Workshop       Valve Applications             153     Successful Refinery Noise Reduction - ISOMAX Quench             For many years, there has been a high magnitude tone generated in the ISOMAX area of
                                                      Valves                                                          the Chevron El Segundo Refinery near the non-Fisher quench valves for two of the reactors.
                                                                                                                      It has increased over time, eventually causing local neighbors to give noise complaints. A
                                                                                                                      Fisher Controls test engineer performed a noise and vibration survey in July 2009. It
                                                                                                                      determined that the main noise source were the stems of the quench valves. Caltrol
                                                                                                                      developed a solution to replace the quench valves with Fisher 4x3 Inch Type HPT-657-
                                                                                                                      DVC6000. Since installed, all tones have been eliminated.
Workshop       Valve Applications             170     Fisher Control Disk™ Valve Solves Temperature Control           Shell Todd Oil Services gas plant in New Zealand had experienced a change in
                                                      Issue in Fractionation Column                                   production rate through their fractionation unit that separates methane and Liquefied
                                                                                                                      Petroleum Gas (LPG). The butterfly valve that was in service could not adequately control
                                                                                                                      the temperature at the new set point resulting in poor product quality and decreased
                                                                                                                      revenues. The Fisher Control Disk Valve replaced the existing butterfly valve in 2006
                                                                                                                      improving control and resulting in increased purity of the natural gas output stream. The
                                                                                                                      Control Disk Valve is still installed and performing great.
Workshop       Valve Applications             177     FIELDVUE DVC’s Help Increase Efficiency and Uptime for          Praxair owns and operates hundreds of cryogenic air separation plants globally, many of
                                                      Air Separation Plants                                           which use old operating methods that reduce the potential efficiency and uptime of the plant.
                                                                                                                      Through their R&D department Praxair has come up with various solutions to increase the
                                                                                                                      efficiency and uptime of these plants utilizing new technology, the most promising of which
                                                                                                                      is utilizing FIELDVUE DVC's to slowly open their feed valves into their temperature swing
                                                                                                                      adsorption units.
Workshop       Valve Applications             222     What is better? HART communications? Or a thousand feet         For getting the stem position, the traditional solution was to mount an independent position
                                                      of wire?                                                        transmitter onto your valve assembly and run thousands of feet of signal wire into the field to
                                                                                                                      connect it to your AI channel on your DCS. It is common knowledge that thisis faster than
                                                                                                                      feedback via HART messaging. Or is it? This workshop will explore your options.

Workshop       Valve Applications             239     Control & Maintenance Optimization Process - Petrobras
                                                      Refinery REPLAN – Maintenance Contracts                         Petrobras REPLAN, one of Petrobras Business Units, has a maintenance contract for
                                                                                                                    control valves with Emerson Process Management. This also allowed the improvement of
                                                                                                                    various processes, especially in the last year on the IGV-22650 (FCC air blower capacity
                                                                                                                    control), using 2 DVC's redundant controler this process.
Workshop       Valve Applications             273     Salvaging a Start-Up: Recovery and Repair Save the Day for When the discovery that hydrogen sulfide had eroded the internal surface of a severe
                                                      Chevron                                                       service valve beyond repair, start up after a planned maintenance turnaround was in
                                                                                                                    jeopardy of being delayed at the Chevron, El Segundo, plant. Typical repair and
                                                                                                                    replacement options meant further delay, costing the plant lost revenue. This paper will
                                                                                                                    demonstrate how Emerson was able to salvage another valve and leverage supplier
                                                                                                                    relationships to provide a same-day solution which allowed the plant to start up on time.
Workshop       Valve Applications             279     Online Overhaul: Technicians Take on Technology to            A corporate initiative to improve reliability through predictive maintenance practices has
                                                      Provide Instant Access to BP Automation Upgrades              prompted the BP refinery in Texas City to implement an automation upgrade program.
                                                                                                                    Systematically replacing analog devices with digital valve controllers while the plant is online
                                                                                                                    allows maximum use of diagnostic capabilities with minimal downtime. This paper will
                                                                                                                    demonstrate how Emerson was able to build on the knowledge of hot cutover methods to
                                                                                                                    allow for device installation and instant diagnostic access for critical control valves while
                                                                                                                    online, despite the lack of a bypass system.
Short Course   Valve Applications             386     Control Valve Troubleshooting and Performance Tracking -      Combining traditional physical evidence-based troubleshooting and off-line and on-line Asset
                                                      There's an App for that.                                      Management tools and Performance Diagnostics (now available for use from a cell-phone)
                                                                                                                    we can move from post-mortem failure analysis to preemptive and preventive maintenance,
                                                                                                                    improving process performance and reducing downtime.
Workshop       Valve Applications             389     40 Years Later and Valero Benicia is still utilizing Fisher's There is nothing more concerning to a refinery than trying to replace a valve design that has
                                                      7600 Buttefly Valve                                           lasted more than 40 years in service and now is obsolete. As the need for more efficient
                                                                                                                    and cost effective processes increases, so does the complexity of the applications that
                                                                                                                    process control equipment is exposed to. Customers are continually driving for longer
                                                                                                                    lasting equipment that can withstand the harshest of environments and still maintain
                                                                                                                    performance reliability; Fisher is dedicated to helping customers with this goal.




                                                                                     Page 35 of 91                                                                                                (Rev. 051010)
                                                                           2010 Emerson Global Users Exchange
                                                                                   Sessions by Track



                                               Session
     Type                              Track                                         Title                                                                          Abstract
                                                  ID
Workshop       Valve Applications                462     Suncor’s use of Fisher Furnace Feed design in Coker            Suncor Energy Inc. is using the Fisher Furnace Feed design on the Cokers for the Voyageur
                                                         Charge service in the Oilsands.                                project. Working together Fisher, Spartan, IV&S and Suncor have evolved the design over
                                                                                                                        several generations to provide a robust, reliable and cost effective solution to a challenging
                                                                                                                        application.
Workshop       Valve Applications                469     Control-Disk valves make worlds largest CFB Power Plant        FisherControls provided Qty 36 Control-Disk valves to JEA's 300-MegaWatt Northside
                                                         more efficient!                                                Generating Station Units 1&2. This is the world's largest circulating fluidized bed (CFB)
                                                                                                                        boiler in the world. This power plant produces electricity by burning coal and petroleum
                                                                                                                        coke. The Control Disk valves are installed just upstream of the fluidizing air nozzles in the
                                                                                                                        bottom of the combustor. That air expands the bed, creates turbulence for enhanced mixing
                                                                                                                        and provides most of the oxygen necessary for combustion of the fuel. Improved flow to
                                                                                                                        the nozzles improves combustion and efficiency for the plant.

Workshop       Valve Applications                473     Application Expertise Results in Big Savings                 For years, Koch Nitrogen's facility in Enid , OK has experienced issues with their critical
                                                                                                                      Benfield solution control valves. These issues resulted in high annual maintenance costs,
                                                                                                                      increased downtime, and reduced performance and efficiency. Combined with
                                                                                                                      Fisher'sapplication expertisein highvibration and severeflashing erosion, an engineered
                                                                                                                      valve solution was developed resulting in lower annual maintenance costs, reduced
                                                                                                                      downtime, and better performance.
Workshop       Valve Applications                485     Engineered Dirty Service Valve Solution Benefits Aera Energy Water injection service is one of the most severe valve applications associated with the oil
                                                                                                                      production process. Whether the customer intends to dispose of their unwanted produced
                                                                                                                      water or enhance production via waterflood, this application requires careful valve selection
                                                                                                                      to ensure the installed product can handle the severity of the service. Produced water
                                                                                                                      contains abrasive residual components and is subject to extreme pressure drops associated
                                                                                                                      with the injection process. Emerson provided Aera Energy a successful Fisher valve
                                                                                                                      solution to handle these difficult conditions.
Workshop       Valve Applications                530     Severe Service Valve trim enhancement solves maintenance One of the top oilsands producers in Alberta Canada's Athabasca region expressed a desire
                                                         headache, extends shutdown interval                          to achieve improved shutoff performance from the control valves installed in the steam
                                                                                                                      generator blowdown application. This particular application has traditionally been very
                                                                                                                      difficult due to the various process conditions that the valve must undergo; cold cavitating
                                                                                                                      water, hot flashing water, and eventually 80% quality steam. Aside from the obvious
                                                                                                                      process hurdles, mis-specification of the required shutoff class is common which can lead to
                                                                                                                      further trim integrity concerns after initial startup.
Workshop       Valve Applications                549     Optimizing Plant Performance Using Predictive Diagnostics    Traditional control systems have been used in process control and manual labor has been
                                                         via Digital Valve Controller Mounted on Control Valve        used for maintaining field devices. Traditional control systems do not provide a systematic
                                                                                                                      way to monitor, diagnose and improve performance of field devices. Pneumatic or electro-
                                                                                                                      pneumatic devices do not have intelligence. Advances in control instr systems have brought
                                                                                                                      new dimensions to provide optimum plant performance by using intelligence from field
                                                                                                                      devices. Challenges still remain on use of appropriate field devices. Field devices like
                                                                                                                      sensors/FCE are important for precise control/higher plant efficiency but FCE is most critical.

Workshop       Valve Applications                557     Control Valves and Regulators for the Pharmaceutical           Genzyme chooses Emerson for its new biomanufacturing plant in Lyon, France, for the
                                                         Industry                                                       production of of Thymoglobulin (Anti-thymocyte Globulin [Rabbit]), a product to treat acute
                                                                                                                        rejection in transplant patients.
Short Course   Wireless Applications              8      Remote Automation System Upgrade                               Implemented Fisher FloBoss 107s, ROC 800s and CygNet SCADA in Williams' Piceance
                                                                                                                        Basin Assets. Conducted successful Pilot Project (2008 to 6/2009) and Transitioned to full
                                                                                                                        scale deployment (6/2009).
Workshop       Wireless Applications             36      Improving production with wireless temperature monitoring      We are helping the operation of their iron ore pelletizing furnace in Vitoria, Brazil, one of the
                                                                                                                        largest in the world, thanks to the fact that Smart Wireless makes it possible to monitor
                                                                                                                        process variables on a moving equipment, something that was not possible before with
                                                                                                                        conventional wired approach. This is a small application, but it is extremely strategic to their
                                                                                                                        production because the furnace is the heart of their operation.




                                                                                       Page 36 of 91                                                                                                  (Rev. 051010)
                                                                            2010 Emerson Global Users Exchange
                                                                                    Sessions by Track



                                               Session
     Type                              Track                                          Title                                                                         Abstract
                                                  ID
Workshop       Wireless Applications              59     Lixiviation Performance Monitoring with Smart Wireless          Barrick, the biggest gold producer in the World is the owner of the Zaldivar Plant in Chile, an
                                                         Technology at Barrick Zaldivar                                  open-pit, heap-leach copper mine in the north of the country that produces 150K tonnes of
                                                                                                                         pure cathode copper a year. The copper extraction process at that mine is lixiviation (leach
                                                                                                                         pads). The product irrigated and distributed in the pad (sulphuric acid) is a critical variable
                                                                                                                         that impacts the whole process. In this workshop it will be presented how the Smart Wireless
                                                                                                                         technology allowed improving the plant's throughput giving Barrick the necessary tools to
                                                                                                                         optimize the process.
Workshop       Wireless Applications             65      The Right Bus for the Right Application: To Be or Not to Be     An Acid plant with a capacity of 300 tons/day is under construction in the Third Region of
                                                         WirelessHART in a Sulphuric Acid Production Plant               Chile. The objective of the plant is to provide the necessary amount of Acid for the Leaching
                                                                                                                         Copper Production Process. This project was developed in response to the shortage and
                                                                                                                         high cost of this product, which is necessary for the process. In case of overproduction, Acid
                                                                                                                         could be sold to third parties.
                                                                                                                         As part of the construction, it was necessary to include instrumentation with easy installation
                                                                                                                         and a low total cost of implementation.
Workshop       Wireless Applications             78      Flexible and clean design with wireless installation            Abstract;     A bioethanol pilot plant was designed and built 2009 in order to develop in-
                                                                                                                         house process technology at Chematur. This was realized utilizing state of the art
                                                                                                                         automation equipment, such as Foundation Fieldbus and Wireless HART instruments. This
                                                                                                                         in order to evaluate new technology for possible future large-scale implementations, as well
                                                                                                                         as to show potential customers and clients how a thought-through PlantWeb-concept can
                                                                                                                         give benefits to operation and production.

Workshop       Wireless Applications             87      Installation Cost Savings with Smart Wireless Technology in     This is a Smart Wireless application for oil temperature and flow measurement at Petrolera
                                                         an O&G Field? Prove It!                                         Entre Lomas field in Argentina. Entre Lomas field produces oil & gas and it is part of the
                                                                                                                         Entre Lomas concession, approximately 60 miles north of the city of Neuquen on the
                                                                                                                         eastern slopes of the Andes Mountains
Workshop       Wireless Applications             125     Utilizing AMS softeware to Plan a Wireless Network




                                                                                                                       This presentation will detail the work involved in utilizing AMS Wireless Snap-On to plan a
                                                                                                                      wireless network at the Conoco Phillip Bayway refinery tank farms.
Short Course   Wireless Applications             135     Wireless Temperature Measurements Enable Smart               At the ConocoPhillips refinery in Lake Charles, LA, an Emerson wireless system was
                                                         Exchanger Maintenance                                        installed in order to optimize exchanger maintenance scheduling.
Workshop       Wireless Applications             159     Emerson Smart Wireless Solution ensures on-time installation This presentation covers a wireless installation at the Atlas Natural Gas Plant (Midkiff)
                                                                                                                      outside of Midland, Texas. The project was a fully integrated solution of Delta-V and
                                                                                                                      wireless seamlessly integrated by Vinson Process Controls out of Midland, Texas. The
                                                                                                                      project is an upgrade to an existing "pnuematically controlled" system and then a new
                                                                                                                      expansion plant.
Short Course   Wireless Applications             163     Smart Wireless Vision, Opportunities, and Solutions          Smart Wireless Solutions for field instrumentation and plant-wide operations can unlock
                                                                                                                      unprecedented process efficiency, asset protection, maintenance, and health-safety-
                                                                                                                      environmental capability. This short-course will explore the various applications and wireless
                                                                                                                      strategies including: personnel safety mustering, mobile workers using 3G wireless, and
                                                                                                                      pervasive WirelessHART field networks.
Short Course   Wireless Applications             181     Understanding and Using WirelessHART™ Technology             The presenters will provide a detailed overview of WirelessHART technology including
                                                                                                                      understanding, using and planning for deployment of the WirelessHART technology to
                                                                                                                      improve plant performance.
Workshop       Wireless Applications             189     Deploying Wireless in the Process Industries                 Building on the success of the global "Deploying Wireless in the Chemical Industry" webinar
                                                                                                                      series, this short course will explore the benefits that wireless technologies bring to a variety
                                                                                                                      of users in more detail in a highly interactive session. Learn about the unique capabilities
                                                                                                                      that wireless technology can make to production, maintenance, projects, systems and
                                                                                                                      executive management. Wireless is not just another protocl, but a technology which has the
                                                                                                                      potential to transform the way that you work.




                                                                                        Page 37 of 91                                                                                                (Rev. 051010)
                                                                           2010 Emerson Global Users Exchange
                                                                                   Sessions by Track



                                               Session
     Type                              Track                                         Title                                                                     Abstract
                                                  ID
Workshop       Wireless Applications             196     Wireless Conductivity and pH Measurements for               The application of carbon capture to existing power plants requires a significant capital
                                                         Optimization of Carbon Capture                              investment on the order of $1,000,000 per megawatt capacity. The annual energy cost
                                                                                                                     associated with carbon capture for a typical power plantis on the order of hundreds of
                                                                                                                     millions of dollars per year. This presentation shows how wireless conductivity and pH
                                                                                                                     transmitters interfaced to DeltaV were used in extensive lab testing to develop relationships
                                                                                                                     for CO 2 and solvent concentration for optimization of solvent concentration to reduce
                                                                                                                     initial investment and operating costs.
Short Course   Wireless Applications             197     An in-depth look at WirelessHART                            This talk is based on our 2010 book "WirelessHART: Real-Time Mesh Network for Industrial
                                                                                                                     Automation" (http://www.springer.com/engineering/signals/book/978-1-4419-6046-7). Our
                                                                                                                     book provides comprehensive information for academic researchers and automation
                                                                                                                     practitioners such as vendors and users. It is a single reference point for all aspects of
                                                                                                                     activities involving WirelessHART and industrial wireless in general. The talk follows the
                                                                                                                     book and covers four sections, WirelessHART in a Nutshell, WirelessHART in Depth,
                                                                                                                     WirelessHART in Practice, and WirelessHART in the Bigger Picture.
Workshop       Wireless Applications             201     THUM’S UP! : Wireless Troubleshooting of Intermittent
                                                         Upsets                                                        A major Pulp and Paper manufacturer was experiencing occasional process upsets
                                                                                                                     attributed to "questionable" flow measurements. Before techs could inspect the flow meter,
                                                                                                                     the upset would reset. Lack of SMART I/O prevented onlinediagnostic monitoringuntil a
                                                                                                                     SMART Wireless Network was installed in a nearby process area. A THUM Smart Wireless
                                                                                                                     HART Adapter was added to the transmitter in question and continuous monitoring of the
                                                                                                                     device diagnostics began. Flow uncertainty was eliminated. Installation of the THUM 20'
                                                                                                                     above the transmitterexpanded thewireless network into the new process area.

Workshop       Wireless Applications             205     Solid Drain Waste System                                    Basically the process works in the following way: Alunorte produces a basic material for
                                                                                                                     producing aluminum, called alumina. Every moment big trucks bring to the DRS tons of a
                                                                                                                     residue that is results of processing alumina which is very rich in caustic soda and is very
                                                                                                                     alkaline also. After that they are disposed in that DRS area. So this material CAN NOT
                                                                                                                     LEAK to the environment, if that happens is a tragedy, there are lot of people those depends
                                                                                                                     the rivers and the environment there.
Workshop       Wireless Applications             223     Cost effective means for Wireless Liquid Hydrocarbon Leak   This discussion will cover how wireless technology can cost competitively ensure solutions
                                                         Detection                                                   for underground leak detection, rapid surface spill detection, and a means to monitor water
                                                                                                                     discharge for oily contaminates. The presentation will cover how this joint technology will
                                                                                                                     provide a reliable solution with the application of the WirelessHART technology.

Workshop       Wireless Applications             225     Smart Wireless Measurement Avoids Shutdowns of a 16MW       Newmont's Minera Yanacocha complex in Peru is the largest gold mine in Latin America and
                                                         Rotating SAG Mill at Newmont’s Minera Yanacocha complex     the second largest in the world. In 2009, Newmont decided to start monitoring the
                                                                                                                     temperature of the SAG mill's motor, the main critical equipment for the process. This
                                                                                                                     application includes a Smart Wireless temperature device rotating with the gold mill and it is
                                                                                                                     impossible to implement without this technology. This is an extension of the PlantWeb
                                                                                                                     digital architecture that Newmont implemented for the Gold Mill project in 2008.

Workshop       Wireless Applications             227     Smart Wireless and Ultrasonic Technology Generate $4M       With the implementation of Smart Wireless (including a network's expansion adding 50%
                                                         Incremental Sales and Reduce 62% Maintenance Costs at       more devices in one year) and installing Ultrasonic technology and AMS Device Manager,
                                                         Tecpetrol                                                   Tecpetrol obtained operational benefits, additional maintenance and supervisory cost
                                                                                                                     reductions.
                                                                                                                     Tecpetrol is an Argentinean company that has an annual production capacity of 31.7 million
                                                                                                                     barrels equivalent and, with operations in Argentina, Ecuador, Venezuela, Bolivia, Peru and
                                                                                                                     Mexico, has been growing steadily in Latin America.
Workshop       Wireless Applications             231     Monitoring Essential Assets – Wirelessly                    Most plants have real-time monitoring of the most critical major equipment like compressors
                                                                                                                     and turbines, but in the past, real-time monitoring of second-tier equipment has been cost
                                                                                                                     prohibitive. Not so anymore. Emerson is introducing a new suite of cost-effective, wireless
                                                                                                                     asset monitoring solutions designed to provide operator asset dashboards with early
                                                                                                                     warning of equipment failure.




                                                                                       Page 38 of 91                                                                                            (Rev. 051010)
                                                                           2010 Emerson Global Users Exchange
                                                                                   Sessions by Track



                                               Session
     Type                              Track                                          Title                                                                         Abstract
                                                  ID
Workshop       Wireless Applications             242     Smart Wireless Technology applied to Electrolytic Refining in Codelco is a Chile's state-owned copper mining, the World's top copper producer and with
                                                         the M&M Industry                                              the biggest copper proven reserves in the planet. In this application, it will be presented how
                                                                                                                       Codelco is applying the Smart Wireless technology to reduce maintenance costs and
                                                                                                                       instrument the Ventanas plant in the V Region in Chile.
Workshop       Wireless Applications             249     Smart Wireless Technology allows Process Control              Codelco is a Chile's state-owned copper mining, the World's top copper producer and with
                                                         Improvement and Maintenance Savings at Treatment Plant        the biggest copper proven reserves in the planet. In this application, it will be presented how
                                                         in Copper Production                                          Codelco is applying the Smart Wireless technology to improve control actions and monitor
                                                                                                                       process variables in the treatment and gas purge plant at El Teniente plant, located in the VI
                                                                                                                       Region of Chile.
Workshop       Wireless Applications             252     Wireless Steam Injection and Oil Production Monitoring        The Hopkins lease in McKittrick , California produces about 2700 barrels of crude per
                                                         Project                                                       day, at the cost of approximately 20,000 barrels of steam per day (7,000,000 lb per day or
                                                                                                                       close to $10,000,000 per year). It is estimated that ¾ of the cost of one barrel of oil is
                                                                                                                       heating energy (steam).
Workshop       Wireless Applications             265     Wireless Wonder: DuPont's Infrastructure for                  DuPont, the world's largest producer of titanium dioxide, strengthens its businesses by
                                                         Communication, Safety and Success                             making safety, health and environmental issues an integral part of all business activities.
                                                                                                                       When the Edge Moor facility wanted to swiftly increase density of monitoring points for
                                                                                                                       potentially dangerous, ambient, Chlorine gas, they sought assistance from Emerson for
                                                                                                                       configuration and installation of self-contained monitoring devices. This paper will
                                                                                                                       demonstrate how Emerson's wireless installation helped increase plant safety at reduced
                                                                                                                       cost.
Workshop       Wireless Applications             293     Wireless Vibration Solution to maintain process in a Power    The North Jeju Thermal Power Plant, located in northern Jeju island, the Unit No.1~2
                                                         Plant                                                         internal combustion. This plant is being controlled by Ovation since 2004. Power plant is
                                                                                                                       operated by various rotating equipment. This equipment is very important for normal
                                                                                                                       operation. So, the customers want to health monitoring of machinery devices. Customer
                                                                                                                       and we are expecting good result for predictive maintence and PlantWeb advantage.

Workshop       Wireless Applications             299     Every Drop Counts Getting the Most Out of Your Refinery        This refinery presentation will highlight where wireless has been already applied in some key
                                                         with Wireless                                                  application areas as well as some additional example areas where benefits can be realized.

Workshop       Wireless Applications             301     Data Integration Solutions in the Enhanced Oil Recovery        A recent implementation of measurement and data integration was in the Plains Exploration
                                                         Industry Utilizing Rosemount Wireless Technology and           and Producing Company's Hopkins lease in the South Belridge oil field. PXP's engineering
                                                         ProGauge Data Management Technologies                          staff recently installed Rosemount's wireless pressure transmitters and Wireless Gateways
                                                                                                                        to monitor and manage 120 steam injection wells. ProGauge worked with PXP and Emerson
                                                                                                                        to collect wellhead pressure data, calculate steam rate, and provide the PXP operating and
                                                                                                                        engineering staff with the injector data in a format to easily monitor and manage the
                                                                                                                        injectors.
Workshop       Wireless Applications             308     Mobile Worker Unshackles AMS                                   Having implemented a wireless Ethernet backbone in the facility, technicians and operators
                                                                                                                        are free to roam with a thin-client window to a fully functional DeltaV workstation. With the
                                                                                                                        ability to call up operator displays and AMS from anywhere in the plant, the need for local
                                                                                                                        indicators, hand-held calibrators, and separate AMS systems is greatly diminished.

Workshop       Wireless Applications             345     Advanced Wireless Application for Critical Service Valves      Aera Energy in Huntington Beach , California uses 4 Rosemount 702s to communicate
                                                                                                                        the condition of 4 64" critical gate valves. This information is communicated to a centrally
                                                                                                                        mounted Emerson 1420 Gateway. This Gateway communicates the information to an
                                                                                                                        ioSelect 900mhz radio, which transmits the information 2.5 miles away to the control room
                                                                                                                        delivering confirmation that the valves are or are not closed.

Short Course   Wireless Applications             357     Major Pharmaceutical Company uses Emerson Smart
                                                         Wireless to meet FDA requirements                               A Major Pharmaceutical Company holds their product in mobile, refrigeratedclosed
                                                                                                                        containers, which are located in a parking lot adjacent to the loading area of their facility. In
                                                                                                                        order to meet FDA requirements, the mobile container loads are required to be held at a
                                                                                                                        specific temperature that must be tracked.When it is time for the mobile container to be
                                                                                                                        unloaded, it is moved into the loading/unloading area and temperature should be tracked as
                                                                                                                        well.




                                                                                        Page 39 of 91                                                                                                 (Rev. 051010)
                                                                       2010 Emerson Global Users Exchange
                                                                               Sessions by Track



                                           Session
    Type                           Track                                            Title                                                                   Abstract
                                              ID
Workshop   Wireless Applications             360     Wireless the Power Solution!!!                               A 500 MW combined cycle natural gas co-generation plant consisting of two units has
                                                                                                                  recently made the initial leap into the wireless arena. They did this by purchasing the
                                                                                                                  following:
                                                                                                                    1.) 9 DVCs with the PD tier (4 of them being on non-Fisher valves)
                                                                                                                    2.) 7 AC tier to PD tier step-ups
                                                                                                                    3.) 1 1420 Wireless Gateway
                                                                                                                    4.) 16 775 THUMs
                                                                                                                    5.) 1 475 HART Communicator
                                                                                                                    6.) AMS system w/ Valvelink
                                                                                                                   The system will be live in June and the 2 technicians that were designated by the plant to
                                                                                                                  be site experts are planning to attend Emerson training within this calendar year.
Workshop   Wireless Applications             409     Threat Level Orange: Department of Homeland Security         This paper intends to:
                                                     evaluates Emerson’s Smart Wireless
                                                                                                                   Highlight the Department of Homeland Security (DHS) Control System Security Program's
                                                                                                                  (CSSP) mission, capabilities and specifically their ongoing assessment activities
                                                                                                                   Discuss an actual assessment of Emerson's WirelessHART compliant systems
                                                                                                                   Disclose what was found
                                                                                                                   Detail Emerson's response
                                                                                                                   Discuss possible future activities

Workshop   Wireless Applications             411     Smart Wireless Technology brings in Critical Points with     This presentation will cover the current installation (ULC section) and future installations
                                                     tremendous upside savings                                    (UU4 & AU2) of wireless product to monitor the Z-Purge junction boxes throughout the the
                                                                                                                  BP Texas City Refinerary. BP Texas City has changed its standard practices to require
                                                                                                                  continuous monitoring of Z-purged electrical enclosures. Previously the purges were
                                                                                                                  allowed to be monitored on operator rounds.

Workshop   Wireless Applications             413     Easy Goes It: Southern Power's Wireless Approach to          Southern Power is a leading producer of electricity in the US with a generating capacity of
                                                     Diagnostics with Legacy Controllers                          42,000 megawatts. Most of their plant is connected to AMS Device Manager to monitor
                                                                                                                  device and process health. However 3 combustion turbines, each with 25 devices are
                                                                                                                  controlled by a GE control system which is not connected to AMS. By using the Smart
                                                                                                                  Wireless THUM Adapter Southern Power was able to connect the 75 devices from these 3
                                                                                                                  turbines into their AMS system without any change to their control system.

Workshop   Wireless Applications             414     What Do You Know About Wireless DP Flow? Explore the         Can I use WirelessHART for my DP Flow applications? What are my options for wireless
                                                     Possibilities for Incorporating Wireless into your DP Flow   multivariable measurement? This workshop will demonstrate how to maximize the value of
                                                     Applications                                                 your new and existing DP Flow measurements by utilizing WirelessHART. This workshop will
                                                                                                                  also discuss actual installations that have shown the benefits that can be achieved with
                                                                                                                  wireless DP Flow.
Workshop   Wireless Applications             448     Got Wireless?: Prepare your plant for modernization with     Many process plants only invest in new technology to modernize operations during a
                                                     ROI today                                                    scheduled turnaround for reasons of cost, compexity, and risk. Unfortunatley, market forces
                                                                                                                  do not wait for scheduled maintenance to affect your bottom line. Smart Wireless solutions
                                                                                                                  can be implemented in a hot process with unprecedented ease of use, scalability, and
                                                                                                                  forward operability to ensure ROI achieved today seemlessly integrates into your future
                                                                                                                  modernized control system. Learn how to acheive benefits of wireless today with an eye
                                                                                                                  towards tomorrow.

Workshop   Wireless Applications             451     Wireless Plant of the Future                                 What does a plant of the future look like when there are so many new technologies? Where
                                                                                                                  does one use HART, WirelessHART, Foundation Fieldbus instrument technologies let alone
                                                                                                                  modern control systems and asset management solutions all tied together with a plant wide
                                                                                                                  network of mobile workers and asset tracking? This paper explores a vision of the future and
                                                                                                                  reveals the stepping stones to achieving unprecedented business results by using
                                                                                                                  technology to unleash the greatest asset: people.




                                                                                      Page 40 of 91                                                                                           (Rev. 051010)
                                                                      2010 Emerson Global Users Exchange
                                                                              Sessions by Track



                                           Session
    Type                           Track                                        Title                                                                       Abstract
                                              ID
Workshop   Wireless Applications             452     Hear the Heat: Steam Trap Monitoring                        Steam traps are generally required to have checks done to them on a regular basis.
                                                                                                                 However, resources are sometimes not available and steam traps fail and it could be
                                                                                                                 months before the problem is realized. With the new acoustic transmitter, companies can
                                                                                                                 have insight on the health of their steam traps without having a dedicated person walking
                                                                                                                 around the plant verifying each steam trap. The purpose of this topic is to describe the
                                                                                                                 energy losses that a company has due to faulty steam traps.
Workshop   Wireless Applications             453     WirelessHART Vibration Monitoring                           The P-25 Platform :
                                                                                                                  P-25 is a petroleum platform from Petrobras Brazil and is located at Albacora field, in
                                                                                                                 Macae - Rio de Janeiro - Brazil .
                                                                                                                  This platform was installed in 1996, is a semi-submersible platformand has a installed
                                                                                                                 capacity of 100 k barrels/day and 3000 m3 gas/day.
Workshop   Wireless Applications             454     Wireless monitoring of pH to meet EPA-regulated effluent
                                                     requirements at plant perimeter                              Weyerhaeuser needed to meet EPA compliance regulations for the pH of effluent water
                                                                                                                 exiting the plant. Alternative reporting solutions were defined and cost-quantified including
                                                                                                                 a) 4000 ft. runs of twisted pair wire from three devices to the DCS and b) rerouting analog
                                                                                                                 signals through the OPC server to the host, about 1000 ft.

Workshop   Wireless Applications             461     Does Anyone Hear Me: Your Plant is Crying Out for Help      Every facility has processes going on all the time. It would be impossible for a person to
                                                                                                                 manage everything that the plant does. With high work loads, how can a person get the
                                                                                                                 information they need to make improvements to their processes? It would be helpful to have
                                                                                                                 something looking at every part of the plant but who has time or energy to install and
                                                                                                                 maintain a system like that? A company can gain insight into their plant by installing
                                                                                                                 Wireless Acoustic Transmitters. The transmitters are easy to install and give valuable
                                                                                                                 information that can be used to diagnose problems in the plant.
Workshop   Wireless Applications             464     Using Wireless to Solve the Chalenges of Remotely Located   This presentation covers a wireless installation located in a remote tank farm at Lubrizol in
                                                     Tank Farm                                                   Deer Park , Texas . The project is a fully integrated wireless network into a Delta V version
                                                                                                                 9 control system that allowed for pressure and temperature measurements with easy
                                                                                                                 expansion capabilities.
Workshop   Wireless Applications             465     Wi-Fi Asset Tracking and Management                         This presentation will outline and discuss a number of best practices of Wi-Fi real-time
                                                                                                                 location solutions (RTLS) and how it can: -Save time in locating staff -Reduce costs by
                                                                                                                 tracking and positioning valuable equipment -Allow safety personnel to receive immediate
                                                                                                                 alerts about the location, status and condition of staff and guests -Help to automatically
                                                                                                                 assign maintenance tasks to the nearest qualified employee and provide valuable feedback
                                                                                                                 in terms of forecasting future equipment and staffing needs.

Workshop   Wireless Applications             471     Control Freak? Fully Wireless Control for Tomorrow.         To date, wireless control applications have typically consisted of a wireless measurement,
                                                                                                                 control host, and a wired valve. Thisworkshop will explore new products, technologies,
                                                                                                                 andinnovations in a quest to find fully wireless control. Topics will include current wireless
                                                                                                                 control, self-organizing mesh technology, fast updates, wireless output devices, and power
                                                                                                                 considerations. If applicable, a demonstration of wireless control output will be given.

Workshop   Wireless Applications             475     Emerson helps PEMEX Revitalize Aging Oil Field              This will be a project study demonstrating how Emerson's Smart Wireless technology was
                                                                                                                 applied to an unmanned offshore oil field in Mexico. This oil field, one of the largest in the
                                                                                                                 world, has seen a 50% production decline in the past 7 years. The presentation will
                                                                                                                 emphasize the problem areas the oil field was experiencing, the innovative solutions that
                                                                                                                 have been implimented as well as the additional benefits available with our wireless
                                                                                                                 technology.
Workshop   Wireless Applications             478     Budget and Schedule Savings using Wireless Steam            A major international oil and gas exploration and production company uses Steam Injection
                                                     Injection Flow Monitoring                                   for Enhanced Oil Recovery in Oman. They were using Dynamic Flow Computers to monitor
                                                                                                                 the steam flow into each well, and bringing this data back using an RTU. They investigated
                                                                                                                 the use of Emerson's Smart Wireless to bring the same data back more economically. Pilot
                                                                                                                 installations proved that the technology worked in their application; an initial trial
                                                                                                                 demonstrated installation time savings.




                                                                                  Page 41 of 91                                                                                               (Rev. 051010)
                                                                        2010 Emerson Global Users Exchange
                                                                                Sessions by Track



                                           Session
    Type                           Track                                           Title                                                                      Abstract
                                              ID
Workshop   Wireless Applications             486     WirelessHART Reliability…      …after 100 Million Hours of    By the first quarter of 2010, some analysts have estimated that fields instrumentation
                                                     Operation                                                     enabled by WirelessHART has achieved more than 100 Million hours of reliable and secure
                                                                                                                   operation in the most demanding environments across the world.

                                                                                                                    This short course focused on introducing the technology underpinnings that enables
                                                                                                                   WirelessHART to achieve high levels of operational reliability and security. The course is
                                                                                                                   crafted in a language suitable for technology managers and decision makers in the process
                                                                                                                   control space.
Workshop   Wireless Applications             513     Blast Furnace nozzle monitoring using wireless transmitters   The blast furnace in the plant has 24 nozzles located around it that supply hot air and carbon
                                                                                                                   dust to achieve even heating in the furnace. Flow through the nozzles should be even and
                                                                                                                   constant to have optimal energy consumption and proper operation. Continuous nozzle
                                                                                                                   issues lead ArcelorMittal automation department to find out a way to identify nozzle
                                                                                                                   problems so that they are corrected as soon as possible.
Workshop   Wireless Applications             521     Good Vibes about Wireless at Chevron – Best Practices for     Chevron has conducted extensive research into emerging options for wireless monitoring.
                                                     Wireless Vibration Monitoring                                 This session will highlight their experience with Emerson's wireless monitoring system as it
                                                                                                                   applies to various asset types including pumps and reciprocating compressors. Vibration
                                                                                                                   monitoring is central to these applications, but it is combined with other parameters for
                                                                                                                   maximum effectiveness. [Note: There is an intended co-presenter from Chevron pending
                                                                                                                   mgmt approval, but I could not enter his name yet.]

Workshop   Wireless Applications             523     Geothermal field monitoring using Fieldbus and wireless       Cerro Prieto is the second largest geothermal field in the World. There are 165 steam wells
                                                     instrumentation                                               in operation that supply around 42.15 million tons of steam per year and produced 4,935
                                                                                                                   Gigawatts hour during 2009.
                                                                                                                   To be able to manage the steam wells properly, Comision Federal de Electricidad is
                                                                                                                   automating the field. The first phase of the project is a SCADA system with foundation
                                                                                                                   Fieldbus and wireless transmitters for 19 wells.

Workshop   Wireless Applications             524     DeltaV plus Delta Vibration - Integrating vibration into a    This workshop will outline the best practices for integrating wireless vibration monitoring into
                                                     Process Automation System                                     a DeltaV system for process automation - including lessons learned from a test installation at
                                                                                                                   RockTenn facility. [The end user at this site is submitting another paper to present at
                                                                                                                   Exchange, and has expressed strong interest in partcipating in this workshop as well.
                                                                                                                   However, I don't have written approval to list him as a co-presenter yet, although I am quite
                                                                                                                   sure that this guy will come through.]
Workshop   Wireless Applications             527     PEMEX Intelligent Field using wireless technology             PEMEX's Cantarell field is one of the largest oil fields in the world, on 2003, was contributing
                                                                                                                   60 percent of Mexico's crude oil production. However, the field has been declining to about
                                                                                                                   30%. Operations consist of 200 production wells on more than 50 platforms, which have
                                                                                                                   limited or non-existent power availability and communications infrastructure to transmit data
                                                                                                                   back to the onshore operations facility. PEMEX installed wireless technology to enable better
                                                                                                                   management of the field, increase worker safety and improve environmental protection

Workshop   Wireless Applications             532     Four for One: Increasing Process Efficiency using Wireless    A major Chemical manufacurerfound throughanalysis and lab testing, that improved
                                                     Technology                                                    monitoring of concentration and temperature of a chemical reagent could increase
                                                                                                                   throughput and reduce process costs, but individual monitoring of numerous chambers
                                                                                                                   placed estimated implementation above threshold for project approval. The use of dual input
                                                                                                                   conductivity analyzers for concentration and temperature measurement mated to THUM
                                                                                                                   Smart Wireless Adapter, allowed the desired data to be transmittedeconomically toplant
                                                                                                                   historian for report generation and alerting.
Workshop   Wireless Applications             545     Intrusive and Non-Intrusive Corrosion Monitors Integrated     Opportunity crudes (where corrosives vary) have increased the focus on corrosion
                                                     Into One Online System                                        monitoring. Roxar is the only provider of both intrusive and non-intrusive corrosion
                                                                                                                   monitoring that can be combined into an integrated online corrosion system for improved
                                                                                                                   economic performance and integrity in refineries and upstream operations. With reference
                                                                                                                   to Reliance Industries' Jamnagar Refinery (India), this paper highlights how Roxar's
                                                                                                                   CorrOcean CorrLog, FSMLog, Fieldwatch software and Emerson's Smart Wireless
                                                                                                                   infrastructure, are maximizing the benefits of corrosion monitoring and integrity
                                                                                                                   management.




                                                                                     Page 42 of 91                                                                                              (Rev. 051010)
                                                                           2010 Emerson Global Users Exchange
                                                                                   Sessions by Track



                                               Session
     Type                              Track                                          Title                                                                        Abstract
                                                  ID
Workshop       Wireless Applications             552     Tattletales Will Tell "No Tales, No More": How Wireless   It is best practice to install rupture disks in front of pressure relief valves (PRVs), in services
                                                         HART Improves Safety and Reliability at Oxy Vinyls VCM    where leakage of chemicals through a relief valve are harmful to people or environment. If
                                                         Facility                                                  back pressure builds up in the space between the disc and the pressure relief valve, a
                                                                                                                   rupture disc will not burst at design pressure. This could occur should leakage develoop in
                                                                                                                   the rupture disc due to corrosion creep, fatigue, or physical damage. In many cases, a
                                                                                                                   gauge (tattletale) is used to identify leaks. Operators are required to make rounds to check
                                                                                                                   "tattletales", which is time intensive (costly).
Workshop       Wireless Applications             554     Monitoring Explosion Hazards With Wireless and Foundation An explosion and fire at a sugar factory two years ago brought a renewed interest in
                                                         Fieldbus                                                  monitoring potentially hazardous sources in the manufacturing, handling, and storage of
                                                                                                                   sugar. American Crystal Sugar proactively put together a plan to address these potential
                                                                                                                   hazards in the Class II, Division 1 & 2 Group G areas. To eliminate the chance for explosion
                                                                                                                   this project includes the removal of ignition sources and the monitoring of sources that could
                                                                                                                   become ignition sources using wireless and bus technologies.

Short Course   Wireless Applications             559     Shell France Finds WirelessHART Network Expands Easily         Our chemical facility outside Navarre France started with a small WirelessHART network
                                                         to Meet Environmental Requirements                             that, after one year, proved to be reliable and valuable. We were able to quickly expand to
                                                                                                                        28 devices and 2 Smart Wireless gateway in response to a new French environmental law.
                                                                                                                        The wireless network gave us the flexibility to quickly and cost effectively meet the
                                                                                                                        governmental requirements.




                                                                                        Page 43 of 91                                                                                               (Rev. 051010)
                                                                 2010 Emerson Global Users Exchange
                                                                     Educational Services Courses

Session
                                        Title                                                                          Abstract
   ID
  26      Coriolis Installation Best Practices & Smart Meter Verification This Micro Motion short course is for anyone that is connected with the efficiency, safety and
                                                                          maintenance of any plant process and who wants to maximize profitability, uptime and
                                                                          product quality. You will learn about how to apply it to challenging applications in your plant
                                                                          such as entrained gas processes, empty full empty batching and also learn about an exciting
                                                                          new Micro Motion capability in the area of SmartMeter Verification. Each of thesetopics will
                                                                          be covered in this short course through a combination of presentation materials, live demos
                                                                          and group discussion
  80      Self Organizing Wireless Network Setup - Course 2375EX          This Session is for individuals that want to gain experience setting up the components of the
                                                                          EPM Self Organizing Network.
  154     Practical Loop Tuning using Lambda Tuning Method                Practical Loop Tuning using Lambda Tuning Method' short course is a 3-hour introduction to
                                                                          modern process control concepts that include understanding process dynamics and the use
                                                                          of non-oscillatory Lambda loop tuning methods to improve loop performance and minimize
                                                                          process variability.
  339     Control Valve Selection for Real, Non-Standard, or Critical     This course is recommended for individuals who specify control valves for industrial
          Process Applications                                            processes that exhibit non-standard or non-ideal behavior, or are processes critical to plant
                                                                          function. The course addresses specific process applications, from a "real behavior"
                                                                          perspective, that routinely fall outside the scope of the present day industry standards. The
                                                                          participant will learn how to: identify the correct technical context of the application; identify
                                                                          the correct data for the application context; perform preliminary valve sizing and selection;
                                                                          and account for the effects of the process piping configuration on loop control.

  387     Installing, Configuring, and Commissioning the DVC6200 with
          ValveLink Mobile on the 375/475 Field Communicator                 In this short course, students will:

                                                                             -      Understand the basics of the DVC 6200 Digital Valve Controller non-contact linkage.

                                                                            -  Describe the available arrays and mounting hardware.
                                                                            -  Acquire experience with the various applications including sliding stem, rotary window
                                                                           mounts, and rotary end mounts.
                                                                            -  Acquire experience working with ValveLink Mobile software.

  391     Using ValveLink Mobile for DVC Setup, Configuration, and         In this short course, students will:
          Diagnostics
                                                                            - Explain the basic roles and functions of the ValveLink Mobile application.
                                                                            - Explain steps for configuring and device pairing a Bluetooth HART modem with a smart
                                                                           phone or PDA
                                                                            - Explore the unique ValveLink interface in the Windows Mobile application
                                                                            - Configure, calibrate, tune, and diagnose a Fisher DVC using ValveLink Mobile




                                                                                 Page 44 of 91                                                            (Rev. 051010)
                                                   2010 Emerson Global Users Exchange
                                                       Educational Services Courses

Session
                                      Title                                                           Abstract
   ID
  555     DeltaV S-series Electronic Marshalling           This short course provides hands-on workshops for individuals responsible for implementing
                                                           DeltaV S-series Electronic Marshalling. The lecture will cover the hardware architecture and
                                                           configuration of the I/O subsystem. The hands-on workshops will allow students to install,
                                                           configure and test their I/O subsystem from the screw terminals to the Operator display
                                                            Topics:
                                                            - Hardware Architecture
                                                           - CHARM I/O card
                                                           - CHARMS
                                                           - Configuration
                                                           - Testing

  556     Syncade Suite Overview                           In this short course, students will:
                                                            - Understand how an MES system can improve productivity
                                                           - Understand the Syncade database / hardware architecture
                                                           - Become familiar with the Syncade Suite of applications
                                                           - Access and use each of the Syncade applications

                                                            During the hands-on workshops, students will:
                                                            - Add documents to Document Control and Archiving (DCA)
                                                           - Promote a document in DCA
                                                           - Create an order and execute a simple recipe
                                                           - Add a material and create inventory
                                                           - Execute an event on a piece of equipment
  560     DeltaV Graphics                                  This short course provides hands-on workshops for individuals responsible for building
                                                           DeltaV graphics. The lecture will explain the use of version 11 dynamos and themes and
                                                           allow students to build and test displays using these new features. The course will also
                                                           explain the configuration settings that are available to customize the behavior of the
                                                           dynamos.
                                                            Topics
                                                            - Themes
                                                            - Theme Dynamos
                                                           - Configuration Settings
  564     Fundamentals of Vibration Analysis               This short course is for those with no prior experience in vibration analysis. Students learn
                                                           about causes of vibration and methods of measurement. Emerson's CSI 2130 Machinery
                                                           Health Analyzer will be used to demonstrate vibration principles. Topics covered include:
                                                           * Introduction to vibration
                                                           * Basic fault identification
                                                           * Information to help jumpstart a vibration program




                                                             Page 45 of 91                                                               (Rev. 051010)
                                                                                      2010 Emerson Global Users Exchange
                                                                                                Short Courses


                                                  Session
                     Track                                                             Title                                                                      Abstract
                                                     ID
Asset Optimization                                  352     Enabling and Ensuring Value From Your Predictive           Are your predictive technologies delivering their full value? Learn how PlantWeb Services
                                                            Technology Investment                                      uses a structured approach on your predictive maintenance program to improve your plants
                                                                                                                       bottom line. PlantWeb Services adds value at any stage of a plant's life cycle by optimizing
                                                                                                                       and integrating predictive technologies into a re-engineered maintenance work process to
                                                                                                                       improve manpower efficiency, helping companies to become best cost producers.

Business Operations, Integration & Intelligence     180     Syncade Electronic Workflow / Procedures                   This short course will address approaches to engineering electronic workflow using
                                                                                                                       Syncade. It will address the electronic workflow issues, different approaches with benefits
                                                                                                                       and results, and encourage interaction from the audience. The topics will include common
                                                                                                                       engineering issues such as integration with the process control system, use and
                                                                                                                       management of Syncade behaviors, recipe component boundaries, recipe modularity and
                                                                                                                       standardization, and simple equipment-based recipes. Finally, general tips and lessons
                                                                                                                       learned based on project experience will be discussed.
Business Operations, Integration & Intelligence     212     Syncade Documentation Management of Change                 I. Value of electronic document control: Discuss the current situation with manual
                                                                                                                       document control.
                                                                                                                       II. Business process changes: Adding a document control system allows electronic
                                                                                                                       enforcement of the business rules established
                                                                                                                       III. Implementation Experience: Customer 1 chose a gradual approach, while customer 2
                                                                                                                       used a big bang method. Customer three used the DIY approach
                                                                                                                       IV. Results: Discuss the reductions in review and approval cycle time and the reduction in
                                                                                                                       effort to process a document.
Business Operations, Integration & Intelligence     214     Title: Beyond IO: ISA95 Level 3 and Manufacturing          Process automation is only the starting point for a well automated facility. The application of
                                                            Operations Management                                      ISA 95 Level 3 Manufacturing Operations Management applies IT technology to planning,
                                                                                                                       preparation,procedure execution, materials, documentation, and quality functions. In order
                                                                                                                       to maximize manufacturing efficiency, it is necessary to go beyond the automation of
                                                                                                                       instrumented equipment and address production, materials, and quality operations that are
                                                                                                                       currently coordinated and tracked with paper procedures and documentation and automate
                                                                                                                       the entire manufacturing process from order to shipment.

Business Operations, Integration & Intelligence     491     Managing Electronic Logs and Equipment Status with         Transitioning from Paper to Electronic for Equipment Logs and SOPS. This course will
                                                            Syncade ET                                                 provide ideas of where the Syncade ET Module can help to make the transition from a paper
                                                                                                                       world to electronic on the operational plant.TheETmodule is not for Equipment Tracking but
                                                                                                                       can help to replace othercurrent paper logbookson the operation floor such as clean rooms
                                                                                                                       or shift logs.With ET 4.3, SOPS can now be managed with workflows that are generated by
                                                                                                                       activities logged in ET.
Control System Modernization                        19      Online Upgrade from v6.3.4 to v10.3.1                      Emerson Calgary, and Emerson SureService, will be performing an online upgrade of
                                                                                                                       EEAL's Kizomba offshore sites, in July 2010.
                                                                                                                       Upon completion of this upgrade, I would like to share this project experience at Emerson
                                                                                                                       Exchange. I will discuss the various technical points as listed above, the complexity of the
                                                                                                                       project, and Emerson's approach to lowering risks to the live system. This presentation
                                                                                                                       would serve as a foundation for all customers to contemplate their own upgrade, and the
                                                                                                                       diverse areas needed for consideration.
Control System Modernization                        77      Control Loop Foundation - Batch and Continuous Processes   A new book on process control fundamentals will be published by ISA in September, 2010.
                                                                                                                       This book is based on material originally developed for internal Emerson classes. In this
                                                                                                                       short course the book authors present key areas of the book and demonstrate web base
                                                                                                                       exercises that accompany the book.




                                                                                                    Page 46 of 91                                                                                  (Rev. 051010)
                                                                                      2010 Emerson Global Users Exchange
                                                                                                Short Courses


                                                Session
                     Track                                                             Title                                                                      Abstract
                                                   ID
Control System Modernization                      304     Provox and Siemens S5 to Deltav migration during operation This short course describes a how to migrate a plant from Provox and Siemens S5 PLS
                                                                                                                     control to deltaV control partly during operation. The PLC's is kept as remote I/O by using
                                                                                                                     Profibus net. This course shows the method used in a Yara migration project. The method
                                                                                                                     gives the project flexibility to move the logic during operation or during a shot down.
                                                                                                                       This method reduces the necessary plant downtime needed by the migration project.
                                                                                                                       In some areas the production increased when DeltaV "took over" the control.


DeltaV and Ovation System Applications            375     How to: DeltaV version 10 Group Policy Management             DeltaV version 10 is the first release of DeltaV to take advantage of Microsoft Active
                                                                                                                        Directory Group Policy Objects. Learn how these GPOs are applied and what tools to use to
                                                                                                                        list (and perhaps change) these policies.This is the information that IT personnel know
                                                                                                                        about and the process engineersneed a quick lesson in how to see and manipulate the
                                                                                                                        same information. (This presentation is not intended for IT savvy personnel, this is just the
                                                                                                                        basics for those that have never dealt with GPOs before).
Instrumentation Applications. Instrumentation     512     Introducing the “other” fieldbus: The basics, benefits, and   For the vast majority of Emerson users, the term "fieldbus" refers solely to Foundation
                                                          how to of Profibus                                            fieldbus. Well this year, Emerson is launching a complete portfolio of solutions that
                                                                                                                        communicate on the industry's other fieldbus, Profibus.
                                                                                                                        This short course introduces users to the Profibus protocol. We will begin with a 30 minute
                                                                                                                        presentation reviewing the history, trends, and applications where Profibus has brought
                                                                                                                        value to end users. We will then move from screen to labs and guide users through
                                                                                                                        implementing their own Profibus system - setting up a network and commissioning devices.


Instrumentation Applications. Instrumentation     425     Get Your Ducts in a Row For Better Flow Measurement           With a focus on energy management and meeting impending greenhouse gas legislation,
Flow                                                                                                                    more plants are looking at monitoring air flow in ducts, especially those that have not been
                                                                                                                        considered reliable flow measurement points. Duct flow measurement poses unique
                                                                                                                        challenges due to the unique geometry and installation challenges. This paper will address
                                                                                                                        possible solutions using DP flow technology and field calibration methods that confirm
                                                                                                                        results.
Maintenance & Reliablity                          323     Rosemount Radar Master - The Ultimate Software for Radar      Learn through hands-on exercises how to conduct quality commissioning and advanced
                                                          Level Configuration and Troubleshooting                       troubleshooting of your radar by Rosemount Radar Master. You will discover Radar Master's
                                                                                                                        full potentional and learn critical functionalities to tailor your device setup. Why attend?
                                                                                                                        Because an optimally setup device is the highway to improve reliability, reduce down-time
                                                                                                                        and avoid unnecceassary maintenance! This PC software is shipped with every transmitter
                                                                                                                        and we will show you why it is recognized as users' first choice for managing Rosemount
                                                                                                                        radars.
Maintenance & Reliablity                          420     Advanced Pressure Diagnostics in Any System Environment       Advanced pressure diagnostics provide the ability to detect abnormal process conditions,
                                                                                                                        including plugged impulse lines, entrained gas or liquid, furnace flame instability, and
                                                                                                                        distillation column flooding. Diagnosing these conditions can generate a PlantWeb alert, or
                                                                                                                        the diagnostics data can be trended and analyzed in a distributed control system. This short
                                                                                                                        course provides an overview of advanced diagnostics, and presents live demonstrations of
                                                                                                                        strategies for utilizing diagnostics with various hosts, including DeltaV, AMS Device
                                                                                                                        Manager, Wireless, and legacy control systems.
Maintenance & Reliablity                          505     Using Diagnostics from intelligent Motor Controls and AMS     Combining Diagnostic information from Profibus Devices with traditional Machinery
                                                          Device Manager to supplement and expand traditional           Condition Monitoring techniques to provide an holistic machinery Asset Management
                                                          Machinery Monitoring techniques                               Solution. Improving equipment performance, efficiency and reducing costs. Integration with
                                                                                                                        other Asset Management disciplines including Computerised Maintenance Management
                                                                                                                        Systems such as SAP.




                                                                                                   Page 47 of 91                                                                                   (Rev. 051010)
                                                                                2010 Emerson Global Users Exchange
                                                                                          Short Courses


                                           Session
                        Track                                                    Title                                                                       Abstract
                                              ID
Maintenance & Reliablity                     519     Get Wired into Wireless Vibration: A Primer on the Tools,   This 90 minute short course will outline the latest technology for wireless vibration
                                                     Techniques and Applications                                 monitoring along with typical applications and benefits. Topics include an introduction to
                                                                                                                 traditional and cutting edge tools for wireless vibration monitoring, measurement types and
                                                                                                                 best practices on how to implement them, basics of spectrum analysis, and typical
                                                                                                                 applications for vibration in process and asset monitoring.
Maintenance & Reliablity                     553     How to Create a Reliability Program                         A lot of companies strive to create a reliability for instrumentation, but how many are actually
                                                                                                                 successful?This paper will cover the initial creation of an instrument reliability program and
                                                                                                                 some of the successes and setbacks that occurred during implementation.The paper will
                                                                                                                 also cover changes that have been implemented as a result of the instrument reliability
                                                                                                                 program.
Management                                   33      How To Justify New “Smart” Automation Investments           In the current economic climate it is more important than ever to have a solid economic
                                                                                                                 justification for a proposed automation investment, including those based on newer "smart"
                                                                                                                 technologies. W e must be able to convince plant management of the validity of the
                                                                                                                 expected returns to successfully compete for available funds. In this workshop a review of
                                                                                                                 the proper way to perform financial analysis for automation investments is presented with
                                                                                                                 special emphasis on "smart" devices and the integrated systems to support them.

Management                                   120     Manufacturing Execution through Servant Leadership          To achieve 'excellence' in Manufacturing Execution you not only need to hire, promote,
                                                                                                                 develop and retain top talent; but you must develop a culture where you have an organic
                                                                                                                 structure of relationships, participation by the entire group, where people are the greatest
                                                                                                                 assets and sources of creativity; and people embrace suffering as a tool for improvement.
                                                                                                                 Servant Leadershipwill producea culture change for business sustainability.

Process Optimization                         204     Interactive Exploration of Process Control Improvement      The minimization of peak and integrated errors from disturbances are important for key
                                                                                                                 performance indicators (KPI) such as quality, yield, on-stream time, and environmental
                                                                                                                 costs. This short course will show how controller tuning, cascade control, the PIDPLUS
                                                                                                                 algorithm, wireless refresh time, analyzer sample delay, sensor lag, transmitter damping,
                                                                                                                 and control valve sensitivity affect the errors from disturbances and KPI. The attendees will
                                                                                                                 be able to explore process control opportunities via an operator interface to a web
                                                                                                                 accessible virtual plant designed to quantify improvements for loops and unit operations.

Project Management and Engineering Tools     282     Comparative study between DeltaV traditional architecture   The presentation willsummarizea comparative study on the deployment of 16AI on a Delta V
                                                     and Electronic Marshalling                                  control system using two architectures: With traditional IO (one AI card) and with new
                                                                                                                 DeltaV Electronic Marshalling IO (CHARM).

Valve Applications                           102     Improve Ethylene Conversion and Overall Plant Reliability   Within an ethylene plant, there are many ways to improve ethylene conversion, optimize
                                                                                                                 energy usage, use predictive maintenance, increase reliability, and improve safety. Large
                                                                                                                 ethylene plants can have more than 800 control valves in them. This short course will walk
                                                                                                                 through the critical valve applications within the different process units of the plant. It will
                                                                                                                 highlight the valve application, issues/challenges, and the solution.

Valve Applications                           386     Control Valve Troubleshooting and Performance Tracking -    Combining traditional physical evidence-based troubleshooting and off-line and on-line
                                                     There's an App for that.                                    Asset Management tools and Performance Diagnostics (now available for use from a cell-
                                                                                                                 phone) we can move from post-mortem failure analysis to preemptive and preventive
                                                                                                                 maintenance, improving process performance and reducing downtime.
Wireless Applications                         8      Remote Automation System Upgrade                            Implemented Fisher FloBoss 107s, ROC 800s and CygNet SCADA in Williams' Piceance
                                                                                                                 Basin Assets. Conducted successful Pilot Project (2008 to 6/2009) and Transitioned to full
                                                                                                                 scale deployment (6/2009).
Wireless Applications                        135     Wireless Temperature Measurements Enable Smart              At the ConocoPhillips refinery in Lake Charles, LA, an Emerson wireless system was
                                                     Exchanger Maintenance                                       installed in order to optimize exchanger maintenance scheduling.



                                                                                            Page 48 of 91                                                                                      (Rev. 051010)
                                                                    2010 Emerson Global Users Exchange
                                                                              Short Courses


                                Session
                        Track                                         Title                                                                    Abstract
                                   ID
Wireless Applications             163     Smart Wireless Vision, Opportunities, and Solutions      Smart Wireless Solutions for field instrumentation and plant-wide operations can unlock
                                                                                                   unprecedented process efficiency, asset protection, maintenance, and health-safety-
                                                                                                   environmental capability. This short-course will explore the various applications and wireless
                                                                                                   strategies including: personnel safety mustering, mobile workers using 3G wireless, and
                                                                                                   pervasive WirelessHART field networks.
Wireless Applications             181     Understanding and Using WirelessHART™ Technology         The presenters will provide a detailed overview of WirelessHART technology including
                                                                                                   understanding, using and planning for deployment of the WirelessHART technology to
                                                                                                   improve plant performance.
Wireless Applications             197     An in-depth look at WirelessHART                         This talk is based on our 2010 book "WirelessHART: Real-Time Mesh Network for Industrial
                                                                                                   Automation" (http://www.springer.com/engineering/signals/book/978-1-4419-6046-7). Our
                                                                                                   book provides comprehensive information for academic researchers and automation
                                                                                                   practitioners such as vendors and users. It is a single reference point for all aspects of
                                                                                                   activities involving WirelessHART and industrial wireless in general. The talk follows the
                                                                                                   book and covers four sections, WirelessHART in a Nutshell, WirelessHART in Depth,
                                                                                                   WirelessHART in Practice, and WirelessHART in the Bigger Picture.
Wireless Applications             357     Major Pharmaceutical Company uses Emerson Smart
                                          Wireless to meet FDA requirements                         A Major Pharmaceutical Company holds their product in mobile, refrigeratedclosed
                                                                                                   containers, which are located in a parking lot adjacent to the loading area of their facility. In
                                                                                                   order to meet FDA requirements, the mobile container loads are required to be held at a
                                                                                                   specific temperature that must be tracked.When it is time for the mobile container to be
                                                                                                   unloaded, it is moved into the loading/unloading area and temperature should be tracked as
                                                                                                   well.
Wireless Applications             559     Shell France Finds WirelessHART Network Expands Easily   Our chemical facility outside Navarre France started with a small WirelessHART network
                                          to Meet Environmental Requirements                       that, after one year, proved to be reliable and valuable. We were able to quickly expand to
                                                                                                   28 devices and 2 Smart Wireless gateway in response to a new French environmental law.
                                                                                                   The wireless network gave us the flexibility to quickly and cost effectively meet the
                                                                                                   governmental requirements.




                                                                                Page 49 of 91                                                                                    (Rev. 051010)
                                                                  2010 Emerson Global Users Exchange
                                                                             Workshops


                             Session
                     Track                                         Title                                                                     Abstract
                                ID
Asset Optimization               9     Asset Optimization and Instrument Maintenance Strategies
                                       Development
Asset Optimization             18      Asset Management: Leveraging your technology dollars to    Spending capital dollars to save O&M dollars has become an industry obsession and
                                       save O&M                                                   technology provides the tool to make this happen. Technology is the master enabler to
                                                                                                  reduce labor costs, improve plant availability, increase GMWe output, improve heat rate and
                                                                                                  other efficiencies, reduce pollution and extend plant life. This paper will provide a case study
                                                                                                  that builds an asset management system from the CSI vibration monitor and Rosemount
                                                                                                  transmitter to the latest Ovation powered DCS, with all of the tools that can and should be
                                                                                                  used to get the most out of your technology investment.
Asset Optimization             35      A Power Plant's Ten Year AMS Saga: Transition to Online    This session will look at the challenges faced in going to an on-line AMS Device Manager
                                       AMS Device Manager from a Stand-alone Laptop to            and examine how We Energies was able to make it successful at the Valley Power Plant in
                                       Multiplexers to the Ovation Interface                      downtown Milwaukee , Wisconsin . Part of the story has been told in the October, 2007
                                                                                                  issue of Power Engineering magazine in an article entitled "Smart Technologies Sustain
                                                                                                  Plant Reliability, Help Control Costs." Now hear the rest of the story.

Asset Optimization             66      Getting the most out of your AMS Device Manager system     Presentation on how LyondellBasell, Clinton IA, leverages its AMS Device Manager system
                                       and smart devices                                          & smart devices to provide the most benefit, & the synergies created by using both
                                                                                                  technologies to their potential. It will cover plant system architecture, snap-on applications,
                                                                                                  devices & diagnostic revisions utilized at the plant. Predictive/preventative benefits,
                                                                                                  troubleshooting/reactive benefits, & documentation/specification benefits along with
                                                                                                  operational benefits seen. It will also cover the importance of a system owner & roles of the
                                                                                                  owner along with the instrument techs & associated work flows.
Asset Optimization             103     Urban Power in New York City                               New York City faces an imminent electricity supply shortfall due to steady demand growth,
                                                                                                  the anticipated retirement of existing power generation capacity, and difficulty expanding the
                                                                                                  existing local in-city power plants. This need has enabled the implementation of a small-
                                                                                                  scale (<10MW) cogeneration technology known as combined heat and power (CHP)
                                                                                                  systems. Emerson was chosen by Endurant Energy, a leading CHP energy consultant with
                                                                                                  experience in providing a master energy plan to provide Emerson equipment for the
                                                                                                  marquee property in NYC known as One Penn Plaza.

Asset Optimization             119     AMS Restoration: Techniques, Tips & Tricks                 Our presentation will discuss the steps necessary to determine what was attached to AMS;
                                                                                                  some techniques for finding all of the HART devices; lessons learned from restoring the
                                                                                                  structure of the database andthe Calibration Management functionality; and techniques for
                                                                                                  linking site documentation such as P&ID's, loop sheets, spec sheets and equipment
                                                                                                  manuals to each tag to make AMS the single point of focus for instrument information.

Asset Optimization             151     Remote Assistance – Expertise There When You Need It
                                                                                                    Ever had one of those days? Turbine start-up not going as planned? Commissioning a new
                                                                                                  machine and you really don't understand what the vibration data is telling you? Technology
                                                                                                  improvements have made remote machinery diagnostics much easier and faster. No more
                                                                                                  wating for your 'expert' to get on a plane and travel to your site, costing you both time and
                                                                                                  money. This paper will examine three cases in which the machinery health professional was
                                                                                                  in his office thousands of miles from the machinery.
Asset Optimization             164     Italian power plant, Centro Energia Teverola, increase     Emerson Process Management's AMS Suite: Equipment Performance Monitor is helping
                                       efficiency by more than 1 percent                          Centro Energia Teverola S.p.a. improve the efficiency of its 150-MW combined cycle
                                                                                                  cogeneration power plant in Teverola, Italy. Using this combination of software and services
                                                                                                  has enabled Centro Energia Teverola to optimize their maintenance strategy for inlet filters
                                                                                                  on the gas turbines, contributing to an overall efficiency improvement of 1%.




                                                                              Page 50 of 91                                                                                    (Rev. 051010)
                                                                 2010 Emerson Global Users Exchange
                                                                            Workshops


                             Session
                     Track                                        Title                                                                       Abstract
                                ID
Asset Optimization             211     AMS Device Manager - The Best of What's to Come - v11       AMS Device Manager v11 provides support for all of the new hardware options introduced
                                       and Beyond                                                  with DeltaV 11.3 plus support for PROFIBUS DP devices. This session will cover a brief
                                                                                                   review of what this means with v11 and then get into detailon the features planned for the
                                                                                                   next releases of AMS Device Manager in 2011.
Asset Optimization             221     It takes a Big Tool Box to Keep Critical Plant Assets       This session is for individuals who want to benefit from incorporating AMS Device Manager
                                       Available – Our Main Tools are AMS Device Manger and        and AMS ValveLink Snap-on into their plant in a way that will impact their maintenance &
                                       ValveLink                                                   reliability efforts. Techniques used to ensure critical asset availability to production when
                                                                                                   needed, instead of being compromised by day-to-day damage control will be outlined.
                                                                                                   Methodology will be shared pertaining to the use of these major tools in our ongoing asset
                                                                                                   optimization program initiatives at Monsanto's Muscatine facility.

Asset Optimization             241     The Reliability Process at Sipchem                          Operating Sipchem'sJAC complex requireda changein focus from building a plant,
                                                                                                   tosafe,production operations. This workshop will discuss how Sipchem built their Reliability
                                                                                                   program, the process of Asset Ranking, Maintenance Task Development, and the
                                                                                                   CMMSinterfaceinthe quest for World-Class Reliability.
Asset Optimization             364     Using Human Centered Design to Improve Productivity with    Human Centered Design (HCD) has been used effectively with AMS Suite to implement
                                       Handheld Configuration Devices                              "Device Dashboards". These new dashboards provide, in one glance, a clear view of
                                                                                                   everything users need to evaluate, diagnose, and configure a field device. This paper will
                                                                                                   explore how the same productivity benefits achieved with PC based Device Dashboards can
                                                                                                   be realized with a handheld communicator. Numerous examples will be demonstrated using
                                                                                                   the 475 Field Communicator showing how productivity can be improved in the field using a
                                                                                                   handheld with a new User Interface based on the human centered design.

Asset Optimization             378     Implementing and managing a secure WirelessHART             Process industries are buzzing with talk of WirelessHART device networks and the promise
                                       network with AMS Suite                                      of these networkd to provide significant benefits to users. Experience shows your can
                                                                                                   improve energy efficiency, improve environmental compliance, increase unit capacity, and
                                                                                                   increase plant reliability. Learn about the tips, tricks, methods, tools and how those in the
                                                                                                   process industries who have ensured their WirelessHART network's success

Asset Optimization             392     Setup of Devices, DeltaV and AMS Device Manager to          Using Emerson Instruments with the DeltaV control system and AMS Device Manager gives
                                       realize the full benefits of PlantWeb Alerts                a user the opportunity to fully utilize the benefits of the PlantWeb digital architecture. This
                                                                                                   workshop will give users a better understanding on how to set up the architecture in their
                                                                                                   plant.
Asset Optimization             394     Architecting Your AMS Device Manager System to Maximize     AMS Device Manager supports many architecture options. This course will review all the
                                       All the Functionality You Need                              supported architectures available using AMS Device Manager with DeltaV. In addition, we
                                                                                                   will cover architectures with other I/O solutions such as Multiplexers and HSE gateways.
                                                                                                   Finally, we will address the things to be considered when designing your network to achieve
                                                                                                   optimal performance.
Asset Optimization             435     How an existing Meridium customer utilizes AMS Suite data   The unique relationship between Emerson and Meridium created a new version of AMS
                                       to create a complete picture of asset health.               Asset Portal that Super Octanos utilizes to link on-line asset information from the AMS Suite
                                                                                                   into their already existing Meridium application. Now they are able to integrate the online
                                                                                                   diagnostic information into AMS Asset Portal that was built on Meridium's Asset
                                                                                                   Performance Management (APM) Framework, Super Octanos can utilize the pre-defined
                                                                                                   analysis, views and reports based on AMS Suite information to get a clear picture of asset
                                                                                                   health.




                                                                            Page 51 of 91                                                                                       (Rev. 051010)
                                                                                       2010 Emerson Global Users Exchange
                                                                                                  Workshops


                                                  Session
                     Track                                                              Title                                                                    Abstract
                                                     ID
Asset Optimization                                  442     PotashCorp New Brunswick division relies on AMS to save   In 2009 PotashCorp started a $1.67 billion mine expansion in New Brunswick involving: *A
                                                            money and deliver faster start-ups.                       new 2M tonne mine and a 1.2M tonne enhancement to the existing mill *Construction of a
                                                                                                                      new mine and ore concentrator *Expansion of the finishing facilities, centrifuges, drying,
                                                                                                                      screening and dust collection *A new, four circuit Compaction Plant to increase the
                                                                                                                      percentage output of granular product. *A new 30 Km pipeline The existing and new sites
                                                                                                                      will act as a fully integrated processing facility with the existing mill operating at full 0.75
                                                                                                                      million tones capacity during construction of the new facility.
Asset Optimization                                  444     How Profibus DP Can Open Up a Whole New World of          Asset management systems have been used to monitor the health and well being of
                                                            Assets in AMS Device Manager                              instruments and valves. Now with the support of Profibus in AMS Device Manager v11
                                                                                                                      users can now open up to a whole new asset type, drives. This session will highlight how
                                                                                                                      AMS Device Manager can be an integral part of setting up and monitoring overall health and
                                                                                                                      well being of Control Technique drives.
Asset Optimization                                  538     MHM integrated with Delta V for operators benefit         Braskem, one of the largest Petrochemical companies in Brazil, come up with a desirable
                                                                                                                      concept: Asset monitoring for both predictive team and operators team. Of course the
                                                                                                                      information for them shall be different, and shall be presented different: The engineers
                                                                                                                      wants to see Asset information on the MHM software and operators wants something easy:
                                                                                                                      see critical asset alarms, related with vibration analysis, in their alarm history from Delta V
                                                                                                                      control system. The predictive team adjusts the alerts for the MHM and the operators get the
                                                                                                                      same benefit in the Delta V system.
Asset Optimization                                  541     Title: Hidden Power of Information in the AMS Database    By extracting raw data from the AMS database, engineering and operational management
                                                                                                                      information can be made available for a wide array of applications. Discussion to cover the
                                                                                                                      following: Preparing the database for extraction, Techniques for extracting data including
                                                                                                                      both the AMS query building tools and SQL queries using MS Access, and potential
                                                                                                                      applications of information made available through data reduction.
Business Operations, Integration & Intelligence     27      CMMS Integration Using DeltaV and AMS Asset Portal 4.0    Work order entry into a Computerized Maintenance Management System (CMMS) is an
                                                                                                                      essential activity for maintaining peak operation performance and downtime minimization.
                                                                                                                      Too often, the ease of entry and use are sacrificed due to the inherent IT ownership and
                                                                                                                      deployment of the CMMS package. By leveraging the power of DeltaV and Asset Portal,
                                                                                                                      work notification requests are initiated directly from DeltaV Operate on a module basis.
                                                                                                                      Work order status is then viewed in the same context (ISA S88) with the rest of the control
                                                                                                                      system, providing operations with a "one-stop shopping" platform.

Business Operations, Integration & Intelligence     85      OPC Connectivity Options: OPC, Xi and UA                  The DeltaV provides different options to integrate process data with the rest of the
                                                                                                                      enterprise. The OPC portfolio offers different choices for system connectivity: OPC classic,
                                                                                                                      OPC Xi and OPC UA. While all the OPC standards provide data integration, it is important
                                                                                                                      to understand the advantages offered by each option, and which architectures make the
                                                                                                                      best use of each interfaces' strengths.
Business Operations, Integration & Intelligence     86      How to make OPC Architectures Secure                      The boundless enterprise means that control systems are more exposed then ever before.
                                                                                                                      While global connectivity adds agility and knowledge sharing for companies, it is also a
                                                                                                                      concern for security professionals. Knowing how to apply IT network security practices,
                                                                                                                      proper OPC architecture and security enabled products to create robust connectivity is vital
                                                                                                                      to ensuring the control system's integrity.




                                                                                                   Page 52 of 91                                                                                   (Rev. 051010)
                                                                                       2010 Emerson Global Users Exchange
                                                                                                  Workshops


                                                  Session
                     Track                                                              Title                                                                      Abstract
                                                     ID
Business Operations, Integration & Intelligence      99     Flexible Recipes to meet Unique Requirements for           Outline of Topics:
                                                            Pharmaceutical Packaging                                    Background
                                                                                                                        Business Case
                                                                                                                        Problems to Solve
                                                                                                                        Syncade Solution
                                                                                                                        Implementation Challenges
                                                                                                                        Operation Reusability
                                                                                                                        Architecture
                                                                                                                        Systems Integration
                                                                                                                        Results

Business Operations, Integration & Intelligence     131     SYNCADE Integration Architecture                           SYNCADE has an architecture that facilitates integration with external plant systems. This
                                                                                                                       presentation will provide examples from past projects of the features that support integrating
                                                                                                                       a SYNCADE recipe with ERP, Plant Maintenance, and LIMS systems. We will also provide
                                                                                                                       a review of the new features being introduced intoSYNCADE that will extend and enhance
                                                                                                                       the current integration capabilities.
Business Operations, Integration & Intelligence     136     Designing Reusable Objects for Syncade Recipes - A Case    This presentation will provide a case study of designing reusableobjects for SYNCADE MES
                                                            Study                                                      recipes. Recipes for 2 sites were developed concurrently.

                                                                                                                          Highlights include:
                                                                                                                          -Defining Context of Reusability in terms of recipe objects
                                                                                                                          -Pros & Cons of Different Design Approaches
                                                                                                                          -Planning a reusable recipe object library
                                                                                                                          -Benefits of reusable objects
                                                                                                                          -Obstacles & issues confronted
Business Operations, Integration & Intelligence     161     Integrated Factory Acceptance Test Approach                In today's world, operation as well as availability of the process and utility plants rely on the
                                                                                                                         integration of automation system installed in the plant.

                                                                                                                         With newer technology and systems put into test, operators look for easy and smooth
                                                                                                                       operation of the automation system from a single user interface. And for this to happen, a
                                                                                                                       well planned and executed Factory acceptance test is required.
Business Operations, Integration & Intelligence     186     Electronic Workflow for a Bioreactor                       BMS is currently in the commissioning stage of its new state-of-the-art facility in Devens,
                                                                                                                       Massachusetts using DeltaV andSyncade. The project is unique because, to date, it is BMS'
                                                                                                                       most extensive automation of workflow.        The project team learned some valuable
                                                                                                                       lessons andmade some key technical decisions around prompting, phase boundaries and
                                                                                                                       recipe design. This presentation will explain many of the lessons learned using the
                                                                                                                       bioreactor area of the project as an example.
Business Operations, Integration & Intelligence     246     Maintaining Historical Trending During On-Line Migration   Transfer of process continuous control and batch events historical trending, using OPC
                                                                                                                       (OLE for Process Control), on-line during DCS migration.

                                                                                                                        Trends and Events critical to pharmaceutical process records.

                                                                                                                         Challenge to change OPC Server and OPC Client connections at a signal level, one at a
                                                                                                                       time, without disruption to overall system with 15,000 signals being trended simultaneously.

Business Operations, Integration & Intelligence     309     Technology Transfer Troubles                               Challenges for taking a potential molecular or biological entity from research and
                                                                                                                       development to the market can seem insurmountable. We will explore some of these
                                                                                                                       challenges, some solutions that have been implemented in industry, and strategies for
                                                                                                                       managing the technology transfer challenges.




                                                                                                   Page 53 of 91                                                                                     (Rev. 051010)
                                                                                      2010 Emerson Global Users Exchange
                                                                                                 Workshops


                                                  Session
                     Track                                                              Title                                                                         Abstract
                                                     ID
Business Operations, Integration & Intelligence     312     SAP to DeltaV integration using the DeltaV SOA Gateway        This paper describes how SAP Web services, the DeltaV SOA Gateway and the Microsoft
                                                            and SAP Web services                                          .Net Framework are used to enable secure integration between standard SAP BAPIs and
                                                                                                                          DeltaV Recipe Exchange/Campaign Manager WCF Web services. Recipes are sent from
                                                                                                                          SAP to DeltaV, DeltaV batches are run and material consumption and operational data is
                                                                                                                          reported back to SAP. Workflow is secured through a firewall on a configurable TCP port
                                                                                                                          which protects the DeltaV control network from the global Lubrizol network. This solution
                                                                                                                          was developed and implemented globally within Lubrizol and is running in three plants.

Business Operations, Integration & Intelligence     344     Improving Plant Operating Decisions using HART                The title of this presentation may seem to be broad and unspecific - and that is deliberate.
                                                                                                                          For when implementing a practice of monitoring device health across a fleet of refineries,
                                                                                                                          the benefits are many and quite diverse. This presentation provides an overview of the
                                                                                                                          types of benefits realized and describe several in detail of how this knowledge of the field
                                                                                                                          devices has assisted operations to improve process availability and reliability.

Business Operations, Integration & Intelligence     363     Achieving project business goals with a structured approach   Traditionally, after a project is approved, the implementation team is measuredon project
                                                            to PlantWeb projects                                          cost andmilestones. Unlessoriginal business objectives are writtenand integrated into the
                                                                                                                          scope of that project, the project team is often not communicated with and loses sight of
                                                                                                                          those objectives. Most DCS projects offer a broader opportunity to leverage PlantWeb
                                                                                                                          benefits to make sure that the business objectives and metrics that drove the approval of
                                                                                                                          the project are carefully integrated into the project scope. This way, the customer and the
                                                                                                                          project team gain a better understanding of what needs to be accomplished.

Business Operations, Integration & Intelligence     481     Managing Batch Recipe Formulas with Web Services               As manufacturers continue to increase the use of batch
                                                                                                                          automation with sophisticated recipe structures, formula management can require
                                                                                                                          significant effort and oversight.
                                                                                                                           Further complicating the task is the fact that users responsible for
                                                                                                                          managing formulas may not have direct access to the automation systems. As a result, the
                                                                                                                          workflow associated with
                                                                                                                          updating batch recipe formulas can be cumbersome and labor intensive.

                                                                                                                           This session discusses the use of DeltaV Recipe Exchange to provide remote formula
                                                                                                                          access to authorized users, thus streamlining workflow in a batch process facility.

Business Operations, Integration & Intelligence     483     OPC Xi Simplifies Client Access to DeltaV                     OPC has released a new interface aimed at migrating existing OPC servers from
                                                                                                                          COM/DCOM to .NET. .NET is Microsoft's new software environment designed specifically
                                                                                                                          to support secure computing in the Internet world. This new OPC interface has been named
                                                                                                                          Express Interface (Xi) to reflect its primary objectives of ease of use and implementation,
                                                                                                                          including simplified configuration through the use of auto-discovery mechanisms. Xi also
                                                                                                                          makes access through firewalls easy, while providing additional security mechanisms to
                                                                                                                          better protect against external access threats.
Business Operations, Integration & Intelligence     525     EBR in Biotech Formulation, Fill Finish & Packaging           Bristol-Myers Squibb's Manati Puerto Rico has recently implemented electronic batch
                                                            Applications                                                  records for formulation, Fill Finish, and Packaging applications for biotech products using
                                                                                                                          the Syncade Smart Operations Management Suite. Syncade is used for solutions for
                                                                                                                          formulation, vial filling, syringe filling, lyophilization, and packaging. This paper reviews the
                                                                                                                          scope of the Syncade implementation and the business objectives achieved




                                                                                                  Page 54 of 91                                                                                          (Rev. 051010)
                                                                                      2010 Emerson Global Users Exchange
                                                                                                 Workshops


                                                  Session
                     Track                                                              Title                                                                      Abstract
                                                     ID
Business Operations, Integration & Intelligence     540     Simple and Flexible Work Flows to Replace Paper Logs         At facilities operating under a QMS or GMP, there are a range of logs that track the status of
                                                                                                                         equipment. Although electronic process recipes can handle equipment events during
                                                                                                                         manufacturing, stand alone equipment recipes are unique in the following ways: (1)
                                                                                                                         equipment activities are not always associated with a process recipe, (2) equipment
                                                                                                                         instructions can be very simple with little need for an S88 hierarchy, and (3) since many
                                                                                                                         equipment recipes are completed with no exceptions, periodic review by exception focuses
                                                                                                                         on only those recipes where an exception occurred.
Business Operations, Integration & Intelligence     543     Managing the Transition from Paper to Syncade Electronic     At a newfacility orwheninstalling a newproduction line, theElectronic Batch Record (eBR)
                                                            Records in an Operating Facility                             systemcan be commissioned along with the new construction. However, at an operating
                                                                                                                         plant, rolling out an eBR without interrupting production posses major challenges. Lonza
                                                                                                                         Biologicsin Portsmouth, NH elected to roll out eBR in two phases. The first phase included
                                                                                                                         all Syncade functionality and modules including an SAP interface as required to support
                                                                                                                         dispensing and the second phase involved the implementation of electronic batch records
                                                                                                                         on a case by case basis for individual products.

Business Operations, Integration & Intelligence     563     Commercial and Technical Benefits Through Early MAC          This paper presents commercial and technical FEED/EPC project and client benefits from
                                                            Supplier Selection for World Class Grassroots Ammonia        early MAC/MIV Supplier selection using KBR strategies of ISSP and CII PEpC strategic
                                                            Plant                                                        supply. Additional Integrated Technology leveraging was used including AMS and Emerson
                                                                                                                         continuous Field device diagnostics to aid in installation, commissioning and start-up, plus
                                                                                                                         ongoing superior plant performance. KBR World Leader Ammonia process technologies
                                                                                                                         drove the project success in tandem with responsive and unique Emerson PlantWeb and
                                                                                                                         AMS proven capabilities, thru the clarity and power of DeltaV and FF.

Control System Modernization                        25      Wireless Ethernet DeltaV Control Network                     Chemical producer in South Louisiana installed a Wireless Ethernet solution offered by
                                                                                                                         Emerson Systems & Solutions.
Control System Modernization                        62      Control sixteen motors with four Variable Speed Drives       DeltaV/DeviceNet provides a reliable method to control any one of several motors from a
                                                            (VFDs) – How can that be? VFD Implementation on              single VFD. Reducing the number of VFD's greatly reduced the cost of implementation
                                                            DeviceNet                                                    (especially for large motors).
                                                                                                                          Other talking points: Wiring/installation cost reduction with DeviceNet Managing VFD
                                                                                                                         programming configuration for multiple motor applications (i.e. logistics of reprogramming
                                                                                                                         drives) Evaluate various bus systems for communication and control between the DeltaV
                                                                                                                         DCS and the VFDs Load loss detection What the manuals didn't tell you

Control System Modernization                        79      Using new eye-tracking technology to measure the usability   This workshop will provide an overview of the Human Centered Design process and how
                                                            of Control Studio as part of Human Centered Design           eye-tracking technology being researched at Texas State University is helping us evaluate
                                                                                                                         product designs. Performing usability testing early in the design process is a key activity to
                                                                                                                         ensure our products are easy to use and meet the needs of our customers. Learn how you
                                                                                                                         or your plant personnel can help shape the future of Emerson's products by participating
                                                                                                                         directly in the Human Centered Design process.
Control System Modernization                        109     POWER AND GROUNDING: Get it right before you                 When modernizing or migrating your plant control system, existing power and grounding
                                                            modernize and migrate your DCS system                        systems may be inadequate, compromised, noisy, or unsafe with little or no indication of
                                                                                                                         these issues. Old control systems may appear to operate properly especially if they are
                                                                                                                         unable to detect power or ground issues. Equipment or personnel safety may be in jeopardy.
                                                                                                                         This workshop will discuss potential problems and corrective actions.

Control System Modernization                        113     Using FlexConnect to migrate your legacy DCS to DeltaV       FlexConnect is a DCS migration product that allows legacy field wiring and field termination
                                                                                                                         panels to remain in place and connect field wiring with new or existing IO cables to DeltaV
                                                                                                                         IO cards. FlexConnect is sometimes called a wire stretcher.




                                                                                                   Page 55 of 91                                                                                     (Rev. 051010)
                                                                    2010 Emerson Global Users Exchange
                                                                               Workshops


                               Session
                    Track                                            Title                                                                        Abstract
                                  ID
Control System Modernization     195     Charmed – Upgrading UT Pickle Separations to DeltaV v11       This presentation follows the modernization of the UT Pickle Research Site in Austin, TX.
                                         with integrated CHARMS                                        The project includes an upgrade to CHARMS IO (electronic IO) and S-Series controllers,
                                                                                                       installation of new junction boxes, upgrade of graphics, conversion to rack mounted PCs
                                                                                                       and Servers, and modernization of the control room.
Control System Modernization     202     Tuning in on Asphalt Viscosity Blending with Micro Motion     This paper provides an overview of a project at BP Whiting refinery to improve and
                                         and DeltaV                                                    automate the process that produced the Certified Base Asphalt that is used to produce the
                                                                                                       various asphalt grades required by industry for roads, roofing and other various end user
                                                                                                       industries.
Control System Modernization     230     How to Modernize a Large Bulk Product Terminal – Follow a     Vopak Deer Park is the largest bulk liquid terminal in the Houston ship channel. While
                                         Master Plan                                                   some areas of the site are automated, a large portion is still operated manually with very
                                                                                                       little instrumentation infrastructure. The site has now embarked on a multi-year automation
                                                                                                       investment program to install new tank gauges, overfill protection, and physical
                                                                                                       infrastructure to support a fully-automated terminal operation. Such an investment must be
                                                                                                       carefully planned and justified.

Control System Modernization     243     DCS Migration Results At Pharmaceutical Plant                 Initial results of a multi-phase, on-line batch migration of aging DCS system to DeltaV to be
                                                                                                       presented.
                                                                                                           Specifically, focus will be on the WorkPackageswhich handled signal by signal move
                                                                                                       from one DCS system to another.
                                                                                                         Presentation will cover the Learning Objectives established with the first process
                                                                                                       areamigrated.

                                                                                                        Presentation will cover the technical and business results achieved.

                                                                                                         Presentation will cover the Lessons Learned from the initial process area.
Control System Modernization     244     Migration and Modernization – Lessons Learned, Part I         The need to improve process performance is a challenge many face. Process automation
                                                                                                       can be a driver to improve performance, but many times is under used. DCS obsolescence
                                                                                                       has become a reality for others. Automation system modernization is not a common event
                                                                                                       thus most process companies do not have the expertise to plan, implement and start-up a
                                                                                                       modernization automation system. This 2 part workshop discusses refined methods and
                                                                                                       lessens learned from past projects. Best project pracitices, things to watch out for, risk
                                                                                                       mitigation, and justification methods are topics that will be discussed.

Control System Modernization     245     Migration and Modernization – Lessons Learned, Part II        The need to improve process performance is a challenge many face. Process automation
                                                                                                       can be a driver to improve performance, but many times is under used. DCS obsolescence
                                                                                                       has become a reality for others. Automation system modernization is not a common event
                                                                                                       thus most process companies do not have the expertise to plan, implement and start-up a
                                                                                                       modernization automation system. This 2 part workshop discusses refined methods and
                                                                                                       lessens learned from past projects. Best project pracitices, things to watch out for, risk
                                                                                                       mitigation, and justification methods are topics that will be discussed.

Control System Modernization     406     Total Installed and Commissioned Cost Savings Using           Using Electronic Marshalling in greenfield projects or plant expansions offers many
                                         Electronic Marshalling in Brownfield Modernization Projects   advantages over traditional wiring, such as easily accommodating late changes in a project
                                                                                                       and the ability to assign individual I/O channels to any controller.

                                                                                                       Electronic Marshalling can also offer significant benefits in brownfield projects where an I/O
                                                                                                       infrastructure already exists. This presentation will show how Electronic Marshalling can be
                                                                                                       applied to legacy system migrations and save on Total Installed and Commissioned Cost.




                                                                                Page 56 of 91                                                                                      (Rev. 051010)
                                                                              2010 Emerson Global Users Exchange
                                                                                         Workshops


                                         Session
                    Track                                                      Title                                                                     Abstract
                                            ID
Control System Modernization               426     The DeltaV Virtual Power Plant                             A power plant in the midwest needed to train new operators and qualify existing operators
                                                                                                              without effecting the operation of the plant. Working together with the Emerson local
                                                                                                              business partner we delivered a dynamic simulation of the power plant that allowed them to
                                                                                                              train and qualify operator safely, off-line.
Control System Modernization               500     Advanced Process Control gets a Ticket on the “Express”    The " DeltaV Connect" series has been used successfully as the ideal first-step in a
                                                   Train to Migration and Modernization                       long-term migration plan from legacy DCS platforms to DeltaV & PlantWeb at several
                                                                                                              customer sites. In this paper, we show howDeltaV Connect for Honeywell was installed
                                                                                                              because of its robustness to support a DeltaV-based Advanced Process Control (APC)
                                                                                                              system layered onto a legacy Honeywell DCS.
Control System Modernization               508     Three Non-conventional Level Control Applications          a) Advanced Level Control for Processes with Large Transport Delay (Allen-Bradley PLC5).
                                                                                                              Modified Smith Predictor used to control level in a manufacturing facility.

                                                                                                              b) Copper Mine Concentrator Plant Water Management System (Modicon Quantum PLC).
                                                                                                              During the system upgrade a very convoluted and ineffective water management system
                                                                                                              control code was replaces with a compact algorithm.

                                                                                                              c) Water Injection System Surge Tank Level Control for an Oil Production Platform
                                                                                                              (Emerson DeltaV). A challenging surge tank level control problem was solved by
                                                                                                              conventional control tools without resorting to use of a more complex multivariable controller.

DeltaV and Ovation System Applications     14      LEL Monitoring in Pharmaceutical Tray Dryers               In the production of bulk pharmaceuticals, it is common to use tray dryers to drive off
                                                                                                              solvents used to dissolve bulk products. NFPA requires flammable solvent tray dryers to
                                                                                                              come with LEL monitors used to cut off the heat if the dryer chamber exceeds the lower
                                                                                                              explosive limit. OEM dryers typically are supplied with catalytic bead type LEL
                                                                                                              detectorswhich onlylast about one week inside the dryer chamber before needing
                                                                                                              calibration. This paper documents how Delta V and an IR style LEL detector was used to
                                                                                                              monitor LEL in pharmaceutical tray dryer.
DeltaV and Ovation System Applications     28      Guardian for the Average User                              Guardian Support is a prognostic service designed to optimize the availability, sustainability,
                                                                                                              and performance of your DeltaV system. But who really has the time to manage all the
                                                                                                              information that Guardian provides you with? This workshop will focus on how to get the
                                                                                                              most use from Guardian in the least amount of your valuable time.
DeltaV and Ovation System Applications     42      Faux meters – When real instrumentation just isn’t good    One of the key factors to good control system performance is correctly specified field
                                                   enough                                                     instrumentation, But what options are available to the control engineer when instrumentation
                                                                                                              doesn't perform as needed and immediate replacement is not an option? Come see one
                                                                                                              innovative solution to this type of dilemma and the underlying principles for developing
                                                                                                              similar solutions in your plant. Faux meters could very well make you real dollars!

DeltaV and Ovation System Applications     43      Batch Executive crash recovery for DeltaV 10.3 and below
                                                                                                                ISA88 created models to understand the real world of controls, equipment, processes, and
                                                                                                              information management. Since engineering can be creative as everyone seeks a better
                                                                                                              way, the trick is to be flexible enough in the models to allow distress situation and upgrades
                                                                                                              with less effort.As DeltaVprovides flexibility in control system architecture, it also has a
                                                                                                              potential of single point of failure, for million $$$ product and that is Batch Executive .

DeltaV and Ovation System Applications     52      Remote Video with DeltaV                                   Video surveillance is becoming an indispensable part of process plant safety, security and
                                                                                                              operations. Mission-critical video feeds can now be delivered to the control room, office
                                                                                                              buildings and other areas in the plant in a highly flexible way. Using an ActiveX control and a
                                                                                                              software-based camera management system, live video feeds and camera controls can be
                                                                                                              embedded into a DeltaV Operate interface. The benefits of having a live video feed
                                                                                                              embedded within an operator display are many and include safety, security and productivity.




                                                                                          Page 57 of 91                                                                                    (Rev. 051010)
                                                                             2010 Emerson Global Users Exchange
                                                                                        Workshops


                                         Session
                    Track                                                      Title                                                                       Abstract
                                            ID
DeltaV and Ovation System Applications      54     DeltaV Alarm Paging Using OPC and GPRS Modem                 The BMS pilot plants have multiple DeltaV Systems. Process operations needed an
                                                                                                                application for secure 24/7 remote notification of critical alarms. A DeltaV Alarm Paging
                                                                                                                System was designed and implemented. The APS monitors critical alarms from DeltaV &
                                                                                                                notifies authorized users via alarm paging system using a GPRS wireless modem. The APS
                                                                                                                uses the DeltaV PCS with OPC,UCME(alarm paging OPC client installed on a DeltaV
                                                                                                                Application Station), and wireless technologies. Alarms are sent to the users cellphones as
                                                                                                                short messaging text (SMS).
DeltaV and Ovation System Applications     101     Standard Field Junction Boxes for CHARM I/O take away        The concept of electronic marshalling with Emerson's new CHARM I/O can not only be
                                                   stress from your project                                     applied to control room installation. On the contrary CHARM I/O is also ideal as a DeltaV
                                                                                                                remote I/O located in the plant next to sensors and actuators. Pre-engineered junction boxes
                                                                                                                (JB), ready for installation both in hazardous and ordinary locations are available off the
                                                                                                                shelf. Various options allow for adapting to individual customer requirements.

DeltaV and Ovation System Applications     104     DeltaV Context Commenting – Custom Application for
                                                   Electronic Batch Review and Approval                          An R&D facility at Bristol-Myers Squibb uses DeltaV for batch execution and RtReports for
                                                                                                                electronic batch review. Comments entered by the operator via the DeltaV are displayed in a
                                                                                                                general section in RtReports. At review, Quality must visually map each comment to the
                                                                                                                relevant section of the report based on context manually entered into the comment. Review
                                                                                                                is time-consuming. To improve efficiency, BMS implemented an innovation for attaching
                                                                                                                S88 context to the HMI submitted comments. This enables the comments to be sorted into
                                                                                                                the appropriate report section, simplifying review.

DeltaV and Ovation System Applications     110     DeltaV Virtualization – Real Today, A Reality Tomorrow       This presentation examines DeltaV virtualization for engineering design, simulation, testing,
                                                                                                                training, and future on-line operation. A virtual computing platform enables running multiple
                                                                                                                DeltaV workstations and control nodes from a common host computer, and significantly
                                                                                                                simplifies software installation and maintenance. An overview of virtualization will be
                                                                                                                presented followed by practical DeltaV applications available today, and future applications
                                                                                                                of tomorrow.
DeltaV and Ovation System Applications     117     The Dark Side - The Code Behind a Consolidated Operator      Six different facilities were combined into one DeltaV system. Each facility had things that
                                                   Interface                                                    were important to it on their DeltaV Operate Toolbar. With the consolidation, each
                                                                                                                workstation would change its layout based on which operator logged in. Taking advantage
                                                                                                                of a DeltaV upgrade to readdress how things worked behind the scenes, the toolbars were
                                                                                                                combined into an A/B pair with the controls and functions based on the operator's privilege,
                                                                                                                rather than login name. A means for swapping between virtual toolbars was also provided
                                                                                                                for accounts that are authorized for more than one facility.
DeltaV and Ovation System Applications     118     Guidelines for Setting Filtering and Module Execution Rate   The DeltaV system allows the user to select the module execution rate. Also, a variety of
                                                                                                                tools are provided in DeltaV to filter the measurement used in control. To achieve best
                                                                                                                control performance, the module execution rate and the filtering applied to the control
                                                                                                                measurement must be set based on the process dynamics. In this workshop some
                                                                                                                guidelines are given for setting module execution rate and filtering. Examples will be used to
                                                                                                                show the impact of these setting.
DeltaV and Ovation System Applications     123     Energy Efficiency and Production Optimization with           After obtaining substantial installation benefits with a PlantWeb architecture, operational
                                                   PlantWeb Digital Architecture                                savings were obtained. This allowed the architecture's expansion replacing the existing
                                                                                                                SCADA system.
DeltaV and Ovation System Applications     132     Process Analysis Using 3D plots                              The cause and effect of changes in a temperature, pressure or composition profile across a
                                                                                                                process unit can be difficult to analyze on-line using traditional 2D plots. A trial application
                                                                                                                was developed to explore the benefits of using 3D plotting for on-line analysis of profile
                                                                                                                changes. This application was installed at the UT Pickle Research Center to study changes
                                                                                                                in the temperature profile of an absorber unit. Results from this installation will be presented
                                                                                                                and information provided on the 3D plotting application. Also, this application will be
                                                                                                                demonstrated.




                                                                                          Page 58 of 91                                                                                      (Rev. 051010)
                                                                              2010 Emerson Global Users Exchange
                                                                                         Workshops


                                         Session
                    Track                                                      Title                                                                     Abstract
                                            ID
DeltaV and Ovation System Applications     156     Information Security and Industrial Controls Operations    As DeltaV admins become more challenged to maintain a secure system they are beginning
                                                   Dialogue                                                   to encounter more direction and help offered by their IT security staffs. Developing
                                                                                                              communications between the Operations group maintaining the control system and the IT
                                                                                                              group who is concerned with system security is becoming an important aspect of managing
                                                                                                              the control system. This workshop using a dialogue between a DeltaV operations oriented
                                                                                                              viewpoint and an IT staff member viewpoint will help explain how we can learn to
                                                                                                              communicate with each other to develop a security solution that will meet the needs of both
                                                                                                              organizations.
DeltaV and Ovation System Applications     168     DeltaV Development Systems in a Virtualized Enviroment     The power of today's servers are well beyond the demand of most DeltaV systems. The
                                                                                                              currently shipping DeltaV rack mount server has more than enough computing power for a
                                                                                                              development system, not just a ProPlus. Through the use of virtualization on DeltaV
                                                                                                              development systems a significant reduction of hardware costs can be realized without
                                                                                                              sacrificing performance. The additional ability to snap-shot the system before making
                                                                                                              software patches allows quick recovery if a problem develops.
DeltaV and Ovation System Applications     194     Automating Portable Skids in a Hazardous Environment       The pharmaceutical and biotech industries often face the need to automate vessels and
                                                                                                              skids that are truly portable. While commonly done in general purpose areas, this task
                                                                                                              becomes difficult if the area is classified as hazardous. Purge units, grounding, power
                                                                                                              feeds, instrument air, and control signals all require special considerations if the skid is to
                                                                                                              remain truly portable. By combining the use of intrinsic safety, quick disconnects,
                                                                                                              specialized receptacles, carefully selected field instrumentation, fiber optics, and field
                                                                                                              busses, these skids can be fully automated while remaining mobile.
DeltaV and Ovation System Applications     319     DeltaV implementation using change control, cost saving    A completely new plant was built, starting with an existing set of plant P&ID drawings. The
                                                                                                              necessary modifications, due to differences between the plants, were done under Change
                                                                                                              Control. The DeltaV validated code from the existing plant was transferred to the new
                                                                                                              DeltaV system. The code, not modified during the project, was accepted as validated.
                                                                                                              Only code touched by the Change Control Process was tested.
DeltaV and Ovation System Applications     359     A Structured Approach to Implementing PlantWeb Alerts in   Operations and Safety Users are most concerned with situations needing rapid response.
                                                   DeltaV Systems                                             Maintenance and Process Optimization Personnel desire feedback to proactively plan
                                                                                                              responses. Emerson's structured approach to define your PlantWeb alert strategy considers
                                                                                                              the consequence of inaction and the response time to avoid a process or safety impact.
                                                                                                              Emerson's structured approach to IMPLEMENT the PlantWeb Alert Strategy will develop a
                                                                                                              predictive alert strategy to address full utilization of predictive diagnostic capabilities with
                                                                                                              your DeltaV system and AMS Device Manager.
DeltaV and Ovation System Applications     384     Easy Integration of Machinery Protection (vibration) and   Emerson launches easy integration of machinery protection of critical mechanical equipment
                                                   DeltaV                                                     into your DeltaV control system. When plant operators have visibility into the performance of
                                                                                                              turbines, compressors, feed pumps and other mechanical equipment, operators can take
                                                                                                              action before failures occur, avoiding costly plant shutdowns, equipment damage and
                                                                                                              personnel injury. The easy integration includes an auto scan, import tools anda library of
                                                                                                              dynamos that facilitates rapid GUI development. Using direct comparison, see how this easy
                                                                                                              3-step process reduces integration time from days to minutes.

DeltaV and Ovation System Applications     430     Pressure-Temperature Compensation in DeltaV - The Good,    Most gas flow applications require the raw signal from the flow element to be pressure
                                                   The Bad, and the Ugly                                      and/or temperature compensated to a well accepted condition such as standard or normal
                                                                                                              conditions. Although the need for pressure-temperature compensation is well known, its
                                                                                                              various implementations run the gambit from accurate (the good), to inaccurate (the bad), to
                                                                                                              very complicated (the ugly). This paper will discuss several tips and give a number of
                                                                                                              examples for correctly configuring DeltaV blocks such as the pre-built PT Compensation
                                                                                                              composite block, AGA and arithmetic blocks.




                                                                                          Page 59 of 91                                                                                    (Rev. 051010)
                                                                              2010 Emerson Global Users Exchange
                                                                                         Workshops


                                         Session
                    Track                                                      Title                                                                       Abstract
                                            ID
DeltaV and Ovation System Applications     514     Environmental Stewardship is Key to District Heating in    Seattle Steam is a district heating facility providing steam and heat to approximately 200
                                                   Seattle                                                    buildings in Seattle's Central Business District. This 115 year old company recently
                                                                                                              embarked on a modernization program to significantly reduce the carbon footprint of the
                                                                                                              plant and move forward in their goal to be an environmental leader in the Seattle
                                                                                                              community. The plant had produced 100% of its steam through burning natural gas.
                                                                                                              Although this is the "cleanest" fossil fuel available, the district felt there was an opportunity
                                                                                                              to move to renewable fuel that would further reduce the environmental impact of the site.

Emerson Product/Services Update             3      DeltaV Batch Product Update                                The current release of DeltaV includes new functionality for batch users in both the
                                                                                                              regulated and nonregulated environments. Come and join the session to gain a detailed
                                                                                                              look at what enhancements were made.
Emerson Product/Services Update            31      New Product Introduction - Emerson Smart Firewall          Emerson introduces a new easy to implement perimeter firewall to help protect and secure
                                                                                                              your DeltaV network. This firewall that will begin shipping at the end of 2010 is another
                                                                                                              addition to our "Secure Out of the Box" initiative. This firewall will provide plug and play
                                                                                                              functionality coupled with Human Centered Design elements for ease of setup to meet
                                                                                                              installation specific requirements. It also supports intrusion detection and prevention with
                                                                                                              automatic threat mitigation updates to help keep your protection up-to-date against the latest
                                                                                                              threats.
Emerson Product/Services Update            39      DeltaV v11 and Smart Wireless                              Emerson is leading the market in natively integrated wireless offerings. This presentation
                                                                                                              describes four wireless solutions available with DeltaV version 11: (1) Emerson's native
                                                                                                              support of standards-based wireless field instrumentation capabilities with the new
                                                                                                              redundant Wireless I/O Card; (2) Extending the Control Network with wireless
                                                                                                              communication; (3) Integrating wireless communication for both the Mobile Operator; and (4)
                                                                                                              Remote Wireless Video integration embedded vision streaming in DeltaV Operate.

Emerson Product/Services Update            98      DeltaV Operate Product Update                              The current release of DeltaV Operate includes new functionality to enhance operator
                                                                                                              productivity. Com and join the session to gain a detailed look at what enhancments were
                                                                                                              made.
Emerson Product/Services Update            105     Fisher FIELDVUE Product Update                             We will review significant changes that have occurred with Fisher FIELDVUE
                                                                                                              Instrumentation in 2010 and how it will affect Emerson customers. Highlights include:
                                                                                                              release of the new DVC6200 HART and fieldbus linkageless/non-contact digital valve
                                                                                                              controller, ValveLink Mobile for running diagnostics with a 475 or 375 Field Communicator
                                                                                                              or PDA/Smartphone, and the 775 THUM for wireless communications with FIELDVUE
                                                                                                              instruments. We will also review updates of the ValveLink Software product line.

Emerson Product/Services Update            148     New Game-changing Tank Gauging System from Emerson      Cut installation and maintenance expenditures with Emerson's new Inventory Grade Tank
                                                                                                           Gauging system that combines the best of existing and new technology. Well-proven FMCW-
                                                                                                           Radar technology for custody transfer grade accuracy. Based on open standards with 2-wire
                                                                                                           Foundation Fieldbus and Wireless communication protects your investment. Single 2-in-1
                                                                                                           unit with SIL3-Certification for both level and hi-alarm changes best-practices for overfill
                                                                                                           prevention dramatically.
Emerson Product/Services Update            182     User Driven Enhancement Program Update: Voice and Drive The User Driven Enhancement (UDE) program provides the user community a mechanism
                                                   Your Ideas                                              to directly participate in and drive Emerson's product enhancement plans. Users collectively
                                                                                                           input and prioritize enhancement ideas theywould like to see in Emerson offerings. A UDE
                                                                                                           customer committee is empowered to manage the idea selection process and works with set
                                                                                                           Emerson resourcesand budget to put user ideas to action. -See the user ideas that were
                                                                                                           evaluated and selected for development -Meet UDE Committee members who represent the
                                                                                                           user community -Learn how users can voice and drive their ideas




                                                                                          Page 60 of 91                                                                                       (Rev. 051010)
                                                                       2010 Emerson Global Users Exchange
                                                                                  Workshops


                                  Session
                   Track                                                Title                                                                        Abstract
                                     ID
Emerson Product/Services Update     187     A PAT Solution for Pharmaceutical Manufacturing                Emerson and Optimal have jointly developed an integrated PAT solution for the
                                                                                                           Pharmaceutical Industry. The solution combines the Optimal synTQ product with
                                                                                                           Emerson's Syncade and DeltaV products. This presentation will review the solution
                                                                                                           architecture and discuss the possible applications for the solution in Pharmaceutical
                                                                                                           Manufacturing. A brief demonstration of the solution will be incorporated into the
                                                                                                           presentation.
Emerson Product/Services Update     210     Product Update on the Rosemount E-Series Magnetic              Diagnostic enhancements and additional output options increase the technology leadership
                                            Flowmeter                                                      of the Rosemount E-Series Magnetic Flowmeter Platform.
Emerson Product/Services Update     229     SmartProcess® Update                                           Over the past few years, Emerson has developed a number of industry-specific application
                                                                                                           packages that are offered under the SmartProcess brand. The applications provide
                                                                                                           templates, libraries and tools to optimize common process units, such as distillation
                                                                                                           columns, fired heaters, fractionators, boilers and blenders. This year, new SmartProcess
                                                                                                           applications were developed for Critical Equipment Monitoring of heat exchangers and
                                                                                                           pumps. In addition, the Ethylene Furnace Optimizer completed its beta test with excellent
                                                                                                           results. This session will review status, progress and plans for development and support of
                                                                                                           SmartProcess applications.
Emerson Product/Services Update     276     What Problem are you trying to solve? Uncovering the real      When asking your vendor for a particular feature, often the root problem is not exposed, as
                                            problem at hand can lead to innovative solutions and new       the question is asked with a particular solution in mind. In many cases there may be better
                                            product innovations.                                           solutions or new product features that could be developed to solve the problem, but these
                                                                                                           may never see the light of day if the vendor does not know the root problem you are trying to
                                                                                                           solve. This workshop will talk about how some of the new innovations in DeltaV were
                                                                                                           derived and give other examples of approaching problem solving that can be applied to
                                                                                                           other real world situations.
Emerson Product/Services Update     327     Product Update: S-Series hardware                              This is a product update presentation covering DeltaV hardware available in v11, including
                                                                                                           S-series hardware and Electronic Marshalling. Focus is on the latest hardware available and
                                                                                                           upcoming CHARMs for v11.
Emerson Product/Services Update     332     DeltaV system data integration for secure, industry standard   The DeltaV system continues to evolve and adopt new technologies to meet the growing
                                            connectivity                                                   need for data integration. As the demand for data integration increases, so too does the
                                                                                                           demand for securing this data. And the interfaces must be industry standards to allow best
                                                                                                           of breed application integration. This presentation will provide a detailed look at several
                                                                                                           new and updated data integration options in the DeltaV system, including OPC Xi, Web
                                                                                                           services and high-speed Ethernet, which provide fast, efficient and secure means for DeltaV
                                                                                                           system data integration from the plant floor to the enterprise.

Emerson Product/Services Update     343     How Human Centered Design (HCD) principles in version 11       DeltaV innovation has focused on "ease of use" for more than a decade and have
                                            has helped DeltaV users get more things done                   succeeded in making the lives of process and control professional's easier. However, many
                                                                                                           innovations have required changes in work practices and have sometimes limited the
                                                                                                           adoption rates of new technology. With the emphasis on Human Centered Design (HCD) in
                                                                                                           DeltaV v11, Emerson's innovation is now focused on three main goals: 1) to Eliminating
                                                                                                           Unnecessary Work, 2) to Reduce Complexity, and 3) to Embed Knowledge. This workshop
                                                                                                           will talk about how HCD helps customer achieve more by using the new innovations in
                                                                                                           DeltaV.
Emerson Product/Services Update     351     Fisher Control-Disk Valve Development and Future               The Rotary Product Development Group at Fisher Controls released the Control-Disk Valve
                                            Extensions                                                     to be used in general service control valve applications. This product line was designed for
                                                                                                           quick lead-times, easy maintenance, and high marks for reliability. It also introduces the
                                                                                                           patented equal percentage disk, which improves upon the narrow control range exhibited by
                                                                                                           high performance butterfly valves.
                                                                                                                This presentation will cover the development of the Control-Disk Valve, the engineering
                                                                                                           behind the equal percentage disk, future extensions of this technology, and how this product
                                                                                                           can help you the customer.




                                                                                   Page 61 of 91                                                                                      (Rev. 051010)
                                                                                      2010 Emerson Global Users Exchange
                                                                                                 Workshops


                                                Session
                     Track                                                              Title                                                                        Abstract
                                                   ID
Emerson Product/Services Update                   367     High-Tech Teamwork: Turnkey Solutions Offer Increased            Continually improving plant performance through increased revenues and decreased
                                                          Reliaibility                                                     expenses is the biggest challenge when legacy products are taxed by current demand.
                                                                                                                           When customers encounter issues that cross multiple crafts, gathering all the necessary
                                                                                                                           players can be risky and time consuming. Emerson now offers complete project
                                                                                                                           management to provide turnkey solutions that led to increased reliability of CVX valves.

Emerson Product/Services Update                   370     Product Update: DeltaV Digital Bus Technologies                  This presentation will detail recent functionality and Ease of Use improvements to the
                                                                                                                           implementation of digital bus technologies in the DeltaV system. Each new feature will be
                                                                                                                           described along with the benefit(s) to the user. The workshop will also allow users to provide
                                                                                                                           feedback on current digital bus functionality and usability to the DeltaV product marketing
                                                                                                                           organization.
Emerson Product/Services Update                   377     Building a More Fault Tolerant System with Redundant             One of the most common means to achieve a fault tolerant system is through the use of
                                                          Components                                                       redundant components. Redundancy can be deployed to minimize the effects of many faults
                                                                                                                           to maintain the availability of the system. However, redundancy is not a one-size fits all
                                                                                                                           solution as it does have some hidden costs. This workshop will explore the redundant
                                                                                                                           components of the DeltaV DCS and uncover the faults that each were designed to protect
                                                                                                                           against. In addition the workshop will discuss the design issues and tradeoffs made by
                                                                                                                           software developers as they work to create a more fault tolerant product.

Instrumentation Applications. Instrumentation     21      Instruments in Supercritical Biodiesel Process                   Handling high FFA waste trap grease and other multiple characteristic feedstocks requires
                                                                                                                           design and application detail that differs from standard clean fluid applications. Using
                                                                                                                           supercritical technology to convert and vacuum distillation to refinethe material into ASTM
                                                                                                                           6751 specification biodiesel presents challenges to instrument applications. We will review
                                                                                                                           the flow, pressure, level and temperature instrument applications throughout the process
                                                                                                                           that has been producing fuel since March of 2009.
Instrumentation Applications. Instrumentation     22      Foundation Fieldbus, faster, safer, more reliable plants
                                                                                                                             Big $ returns are available when Foundation Fieldbus is used.
                                                                                                                             Using control in the field with intelligent measurement and control devices is 3x more
                                                                                                                           reliable than conventional analogue.
                                                                                                                             This paper builds on newmodeling work completed by ISC Ltdwhich shows that Control in
                                                                                                                           the Field can deliver over 30% tightercontrol response and rejection of disturbance.
                                                                                                                             "major benefits identified are reduced process controller loading, reduced network traffic
                                                                                                                           enabling more loops per segment, as well as very fast loop response"

Instrumentation Applications. Instrumentation     24      Your overfill alarm doesn’t howl very often. Are you sure it’s   Any conventional overfill alarm sensor you may choose for your storage tanks, such as a
                                                          alert?                                                           point level switch, will have one major weakness: You can never be absolutely sure that it
                                                                                                                           still works after a long (or short) period of inactivity. Radar based overfill alarm offers a
                                                                                                                           better solution. It enables continuous feedback to the operator by checking the level multiple
                                                                                                                           times per second. On top of that it can provide SIL rated alarm outputs and redundancy
                                                                                                                           options.
Instrumentation Applications. Instrumentation     30      Are You A “Process Whisperer?” - Best Practices For              Your process is "whispering" its diagnostic secrets to you, but are you listening? There are
                                                          Successful Process Diagnostics With Fast Sampling                many documented applications using advanced process diagnostics with smart pressure
                                                          Pressure Transmitters                                            transmitters. This workshop will review the currently documented diagnostic applications
                                                                                                                           with a pressure transmitter. Then, it will go on to discuss best practices to identify and
                                                                                                                           implement a successful diagnostic application in your process.




                                                                                                   Page 62 of 91                                                                                       (Rev. 051010)
                                                                                     2010 Emerson Global Users Exchange
                                                                                                Workshops


                                                Session
                     Track                                                             Title                                                                      Abstract
                                                   ID
Instrumentation Applications. Instrumentation      75     A journey of 1st generation Mechanical Level Indication to   This paper discusses the problems faced due to MLI & DP Type LTs, Annunciation and,
                                                          cutting edge technology of RADAR type Level System, in       methodology adopted to overcome by using RADAR Type LTs in both the tank-farms, at
                                                          TankFarm Unit, at Reliance, Patalganga, INDIA.               Reliance, PG, India . It focus on improvement carried out, benefits achieved &
                                                                                                                       advantages found in PCs Networking.
                                                                                                                         Accordingly, the article addresses:
                                                                                                                         1.Up-gradation of MLI with RADAR Type LTs with cutting edge technology and reliability
                                                                                                                       improvement
                                                                                                                         2.Automatic accounting of Final product & report generation
                                                                                                                         3.Level trends & Alarm management
                                                                                                                         4.Networking
Instrumentation Applications. Instrumentation     94      Water Draw Control Scheme                                    The project was put in place to control water draw on crude tanks at the Valero Memphis
                                                                                                                       Refinery
Instrumentation Applications. Instrumentation     96      ACHIEVING REDUNDANT INTRINSICALLY-SAFE                       During the last year or so, a variety of approaches have been released offering users new
                                                          FIELDBUS SEGMENTS FOR FISCO & ENTITY DEVICES                 fieldbus segments with redundancy and FISCO device connectivity. This paper describes
                                                                                                                       and compares those new designs with regard to segment capacity, MTBF, overall
                                                                                                                       availability, installation areas and implementation cost .
Instrumentation Applications. Instrumentation     106     Emerson Interfaces to SmartPlant Instrumentation             Emerson has more interfaces to Intergraph's SmartPlant Instrumentation ( SPI ) than any
                                                                                                                       other process controls supplier. This workshop will address t he mechanics of SmartPlant
                                                                                                                       Instrumentation ( SPI ) interfaces to Fisher Specification Manager, Rosemount
                                                                                                                       Instrument Toolkit, and DeltaV DCS Configuration tools, How the interfaces work in Real
                                                                                                                       World situations and what is the future of Emerson interfaces and integration to engineering
                                                                                                                       automation tools.
Instrumentation Applications. Instrumentation     146     EDDL Enhancements and Device Dashboards are the              Historically, level measurement instruments were hard to commission and maintain because
                                                          Building Blocks for Easy Commissioning and Valuable Level    the set-up tools were difficult for the operator to interpret. EDDL with enhancements are the
                                                          Diagnostics                                                  building blocks for constructing a user interface that is consistent for all connected device
                                                                                                                       types. At the host system, a user-friendly Device Dashboard provides intuitive set-up of
                                                                                                                       remote devices and access to valuable diagnostics. Plant personnel can better utilize their
                                                                                                                       instrumentation thereby decreasing maintenance costs, increasing plant availability, and
                                                                                                                       reducing safety risks.
Instrumentation Applications. Instrumentation     152     SIL3-certified 2-in-1 Radar completely redefines best-       With the all-new 2-in-1 Radar Level Gauge both custody-transfer grade level measurement
                                                          practices for overfill prevention in tank farms              and overfill prevention can be performed in the same unit. And it's certified according to
                                                                                                                       IEC61508 for SIL3 safety-loops. Having a single unit considerably reduces cost, fewer
                                                                                                                       device types, single tank-penetration. Continuous measurement for both level and overfill
                                                                                                                       can be used for delta-evaluation or "24/7 proof-testing" which reduces proof-testing intervals.

Instrumentation Applications. Instrumentation     157     Measuring Levels in Highly Dynamic Petroleum Processes       Measuring liquid levels in highly dynamic petroleum processes can be very challenging.
                                                                                                                       Rapid level changes, changing liquid densities, boiling liquids, and interface fluids can
                                                                                                                       combine to make it difficult to get an accurate and/or stable measurement. This workshop
                                                                                                                       will discuss several of these difficult hydrocarbon applications that occur in gas plants and
                                                                                                                       refineries, and the solutions found using the various measurement abilities of high
                                                                                                                       performance guided wave radar. We will also explore how to best set up the measurement
                                                                                                                       in order to improve loop tuning.
Instrumentation Applications. Instrumentation     162     Use of Smart Plant Instrumentation (SPI) in Factory          Smart Plant Instrumentation (SPI) is a key tools in the world of Controls and Instrumentation
                                                          Acceptance Testing                                           field. A powerful tool to access the instrumentation database and used by many users from
                                                                                                                       Client to engineering firms to automation industry.

                                                                                                                          Content of the slides show how effective and powerful SPI can be not only for engineering
                                                                                                                       activities but also for automation part of the engineering. It also describes the additional
                                                                                                                       fields that can be used in intools to help automation and automation FAT activities.




                                                                                                  Page 63 of 91                                                                                    (Rev. 051010)
                                                                                     2010 Emerson Global Users Exchange
                                                                                                Workshops


                                                Session
                     Track                                                             Title                                                                        Abstract
                                                   ID
Instrumentation Applications. Instrumentation     172     Is your Steam Application getting hot?                            A challenge in the power and steam generation is to be able to measure level accurately
                                                                                                                            and reliably in high pressure saturated steam applications such as boiler drums, high
                                                                                                                            pressure feed water heaters, and steam separators. With the innovative technique Dynamic
                                                                                                                            Vapor Compensation (DVC) in Guided Wave Radar (GWR) this is overcome. The workshop
                                                                                                                            will review how saturated vapor affects the measurement and provide 'best practice'
                                                                                                                            guidelines for solution as well as show real life examples.
Instrumentation Applications. Instrumentation     179     Radar technology has increased accuracy and reliability           The EKA Chemicals plant utilized radar technology to automate sanitary sewer level. Eka
                                                          eliminating potential of costly fines from the City Municipality! was originally using non-contacting radar and traditional DP based level technologies. They
                                                                                                                            upgraded to the Rosemount 3300 contacting radar which has increased the accuracy and
                                                                                                                            reliability of the measurement and decreased their maintenance costs, while at the same
                                                                                                                            time eliminating the potential of costly fines from the city municipality.

Instrumentation Applications. Instrumentation     207     How contacting Radar technology has replaced load cell         Red Arrow utilized contacting radar to automate the continuous level in a surge bin. The
                                                          technology to increase throughput and enable continuous        use of radar has enabled this process to be controlled continuously, which has increased
                                                          automated control.                                             process throughput, improved the reliability of the measurement, reduced routine
                                                                                                                         maintenance time, increased safety, and enabled them to automate the level control.

Instrumentation Applications. Instrumentation     218     Does that level really match what is inside my tank? Practical Chambers and stilling wells can facilitate measurements with Guided Wave and Non-
                                                          Solutions for Optimizing Radar Level Measurements in           Contacting Radar level transmitters. Yet if done incorrectly, they can be a source of errors.
                                                          Chambers and Stilling Wells                                    Optimal results can be obtained by following a few basic guidelines. Choices of radar type,
                                                                                                                         antennas or probe, setup tips, and special considerations for interface or steam applications
                                                                                                                         will be covered.
Instrumentation Applications. Instrumentation     224     Driving Automation in Municipal Wastewater Plants              Advances in technology have made motion control equipment robust, economical, and a key
                                                                                                                         piece of instrumentation to the process industry. This session takes a look at the uses of
                                                                                                                         drives in the wastewater treatment facilities and their unique value proposition for energy
                                                                                                                         savings and performance improvements. Many of these improvements and savings can be
                                                                                                                         employed in other process applications as well such as power and energy, oil and gas, life
                                                                                                                         sciences and more.
Instrumentation Applications. Instrumentation     256     Wine Production Optimization thru Mass Balance at Bodega Bodega Norton, located in Mendoza, was nominated as one of the top 20 wineries in the
                                                          Norton in Argentina                                            World and it is one of the leading and traditional wineries with the longest trajectory in
                                                                                                                         Argentina and presence in the main markets worldwide. The well-known quality causes their
                                                                                                                         wines to be distributed in over 60 countries around the World and enjoyed by millions of
                                                                                                                         consumers every day. The purpose of this application is to reduce losses between the wine
                                                                                                                         cellar and the fractionation plant with a mass balance.
Instrumentation Applications. Instrumentation     263     Up from the Depths: Rapid Response Means Real Recovery In September of 2009, a 500 year flood brought $250 million damages to a Northern
                                                                                                                         Georgia Paper Mill. Although not a current Emerson customer at the time, Instrument &
                                                                                                                         Valve Services was contracted along with local business partner—Control
                                                                                                                         Southern—to assist in recovery efforts. This presentation will demonstrate a case
                                                                                                                         study of how swift mobilization of experienced, qualified technicians who built on their
                                                                                                                         knowledge in flood recovery, brought the plant back online.
Instrumentation Applications. Instrumentation     297     How to win a custody battle. Properly instrumenting custody Custody transfer applications have an immediate impact on a plant's bottom line. Proper
                                                          transfer points for maximum ROI.                               instrument selection, installation, and ongoing maintenance are critical success factors for
                                                                                                                         successful plant economics.
Instrumentation Applications. Instrumentation     310     The Balancing Act of Flow Meter Selection                      With advancements being made in flow measurement technology, the decision of which flow
                                                                                                                         meter to use has become increasingly more complex. When does Installed Cost take
                                                                                                                         preference over Reference Accuracy? When do Permanent Pressure Loss and/or Energy
                                                                                                                         Costs need to be the critical priorities? All of these questions affect the decision of which
                                                                                                                         flowmeter is right for your application.




                                                                                                   Page 64 of 91                                                                                     (Rev. 051010)
                                                                                     2010 Emerson Global Users Exchange
                                                                                                Workshops


                                                Session
                     Track                                                             Title                                                                      Abstract
                                                   ID
Instrumentation Applications. Instrumentation     317     Measuring Critical Temperature using Multivariable            Temperature profiles of reactors, tanks and other vessels are common throughout the
                                                          Transmitters                                                  industry. While these might be viewed as monitoring points they are often of critical
                                                                                                                        importance. This paper will explore how to use both wired and wireless multivarible
                                                                                                                        transmitters to provide both a cost effective installation with the required reliability.
Instrumentation Applications. Instrumentation     325     Level ABC for EPC                                             In the competitive environment of Engineering, Project execution and Construction (EPC),
                                                                                                                        the key factors that influences business result are project risks, costs and schedules. During
                                                                                                                        this session, we will share experiences and best practices to assist EPCs how to cut project
                                                                                                                        risk, capital spending, startup time, and shorten project schedule. We will discuss
                                                                                                                        Emerson'sorganizational and product capabilities that has proven to add all of the
                                                                                                                        mentioned values to EPCs already and provide the Level ABC tailored for EPCs.

Instrumentation Applications. Instrumentation     328     The Top 10 ERS Applications for 2010                          Emerson has spent the past several years designing a new DP Level technology, the
                                                                                                                        Rosemount 3051S Electronic Remote Seal System (ERS). ERS works on many of the same
                                                                                                                        premises as today's DP Level technology with one exception: the mechanical capillary and
                                                                                                                        impulse piping that can be problematic in tall vessels and distillation columns are completely
                                                                                                                        replaced with a digital architecture. This paper will provide a brief overview of the ERS
                                                                                                                        technology and then go into detail on the top 10 applications where engineers have already
                                                                                                                        deployed ERS and achieved tangible results.
Instrumentation Applications. Instrumentation     329     How Process Insight Leads to Actionable Information at        Mitsubishi Chemical, recipient of the 2009 HART Plant of the Year Award, is back again to
                                                          Mitsubishi Chemical                                           present new application findings with HART diagnostics. Virtually all dynamic processes
                                                                                                                        have distinctive noise profiles. Applying the advanced diagnostic capabilities found in
                                                                                                                        Pressure Transmitters allows users to profile their process. Users gain more process insight
                                                                                                                        and make quality decisions based on actionable information.
Instrumentation Applications. Instrumentation     330     Demystifying Guided Wave Radar                                During this session, we will shed light on common rumors, misconceptions, and "mysteries"
                                                                                                                        with the Guided Wave Radar technology. Skilled subject matter experts will discuss your
                                                                                                                        GWR mysteries and share reasons and recommended actions to demystify the technology.
                                                                                                                        This session will focus on interaction and live demonstrations to build on your GWR
                                                                                                                        knowledge. Through proper selection of GWR technology, users experience positive
                                                                                                                        business results such as decreased maintenance and operations costs, reduced safety
                                                                                                                        risks, and decreased risk of unplanned shutdown.

Instrumentation Applications. Instrumentation     336     Improving Heater Firing Control and Efficiency with Better    Reducing excess air flow to boilers and fired heaters without compromising safety and
                                                          Damper Performance                                            reliability is one way to improve energy efficiency and profitability of refining operations.
                                                                                                                        However, these efforts are hampered by poorly performing combustion air and flue gas
                                                                                                                        dampers. Damper design and damper actuator performance specifications were developed
                                                                                                                        and implemented to realize more stable and efficient boiler and fired heater operations.

Instrumentation Applications. Instrumentation     337     LyondellBasell Realizes Better Maintenance Practices with     The Clinton complex for LyondellBasell's Equistar subsidiary is one of the largest chemical
                                                          Advanced Diagnostics                                          plants Iowa. This plant utilizes advanced diagnostics from pressure transmitters combined
                                                                                                                        with best-in-class maintenance practices to achieve lower operation costs while improving
                                                                                                                        production of ethylene. This paper will discuss specific applications where advanced
                                                                                                                        diagnostics were used to uncover opportunities for proactive maintenance.

Instrumentation Applications. Instrumentation     346     Level Solutions for Refining can Increase Safety and Reduce The short course will review key level applications in refineries with special considerations
                                                          Maintenance - If Chosen and Installed Correctly             for level measurements in critical applications. In refineries there are several applications
                                                                                                                      where the process conditions are difficult and traditional technologies are high on
                                                                                                                      maintenance costs and/or do not track the changes fast enough. During this short course we
                                                                                                                      will look closer on how radar with high sensitivity can resolvevery demanding process
                                                                                                                      conditions, thus optimizing performance, increasing safety,and reducing the maintenance
                                                                                                                      costs.




                                                                                                  Page 65 of 91                                                                                     (Rev. 051010)
                                                                                      2010 Emerson Global Users Exchange
                                                                                                 Workshops


                                                Session
                     Track                                                             Title                                                                         Abstract
                                                   ID
Instrumentation Applications. Instrumentation     350     High Density Temperature Transmitters in Gasification Pilot    Gas Technology Institute (GTI) recently commissioned the Advanced Gasification Test
                                                          Plant                                                          Facility (AGTF), an addition to its Flex-Fuel Testing Facility (FFTF) for pilot-scale gasification
                                                                                                                         and gas processing systems for commercialization of more efficient energy-conversion
                                                                                                                         processes. Critical process measurement points must be monitored, with data collected
                                                                                                                         and analyzed to verify the process performance. In the reactors, high density temperature
                                                                                                                         monitoring solutions, utilizing the Rosemount 848T and DeltaV, were employed to achieve
                                                                                                                         this goal effectively.
Instrumentation Applications. Instrumentation     365     Battle Royale - HART7 VS Foundation fieldbus                   HART and Foundation fieldbus have brought significant benefits to the process industry.
                                                                                                                         HART enabled device intelligence but has always just been considered an extension to the
                                                                                                                         4-20mA signal. Foundation fieldbus has always been known for its Control-in-the-field and
                                                                                                                         expanded diagnostics and diagnostic information capability. Word on the streets is that the
                                                                                                                         improvements made in HART revision 7 are powerful enough to take on Foundation
                                                                                                                         fieldbus. The paper explores the similarities and differences of the two so you can make an
                                                                                                                         educated decision on which protocol is best for your plant or application.

Instrumentation Applications. Instrumentation     366     Temperature Monitoring and Control of Reactor Performance

Instrumentation Applications. Instrumentation     372     Level Solutions for Power can increase plant efficiency - if   In steam generation facilities, there are applications where having a reliable, accurate and
                                                          chosen and installed correctly                                 safe level measurement is a key to improving efficiencies. Yet there are some special
                                                                                                                         challenges that must be met to ensure the optimum results for efficiency and reduced
                                                                                                                         maintenance. This short course will review key level applications with special considerations
                                                                                                                         for upgrading and optimizing level control in feedwater heaters, boiler drums and related
                                                                                                                         equipment as well as tactics for equipment protection. Best practices for installation of the
                                                                                                                         various level technologies will be covered.
Instrumentation Applications. Instrumentation     381     Making Fieldbus Safer in Hazardous Locations                   This presentation will consider recent advances in technology and products that have
                                                                                                                         contributed to the safety of Foundation fieldbus networks in hazardous locations. Among
                                                                                                                         the technologies adopted world-wide are the 'Fieldbus Intrinsically Safe Concept' (FISCO),
                                                                                                                         and the 'High Energy Trunk' technique which uses Fieldbus Barriers to convert to
                                                                                                                         intrinsically safe spurs in the field junction box. The presentation will explain how more
                                                                                                                         recent product innovations have contributed to improved safety,reliability and ease of use.

Instrumentation Applications. Instrumentation     382     ITK6 What does it mean for you!                                The Foundation fieldbus Interoperability Test Kit (ITK) is an interoperability/conformance test
                                                                                                                         required for Foundation fieldbus certification. The testing jumped a major revision this year
                                                                                                                         to ITK6. The paper reviews the history of ITK, compares the revisions, and expounds on the
                                                                                                                         new mandatory and optional components of the test. Come see why requiring ITK6 may not
                                                                                                                         get the same features in all devices and how to refine your Foundation fieldbus device
                                                                                                                         specifications.
Instrumentation Applications. Instrumentation     383     What’s the Buzz? Wake Frequency Calculations and What          Our understanding of Wake Frequency and thermowell operation in harsh process
                                                          You Need to Know                                               conditions has
                                                                                                                         come a long way, and ASME PTC 19.3TW is being released. What does this mean for
                                                                                                                         you? Learn how to ensure your thermowells are designed to meet and exceed the
                                                                                                                         requirements and how Emerson can help you become a thermowell expert.

Instrumentation Applications. Instrumentation     395     New Sand Management System Integrates Erosion Based            Using an example and field data from Statoil, this paper presents a new sand management
                                                          and Acoustic Sensors alongside a New Generation Sand           system, where acoustic and erosion-based sand sensors are combined and integrated
                                                          Management Software – An Operator Example                      together with new sand management software, to enable increased system availability, more
                                                                                                                         extensive information, and improved alarm settings providing a platform for effective
                                                                                                                         condition based monitoring.




                                                                                                   Page 66 of 91                                                                                        (Rev. 051010)
                                                                                    2010 Emerson Global Users Exchange
                                                                                               Workshops


                                                Session
                     Track                                                            Title                                                                   Abstract
                                                   ID
Instrumentation Applications. Instrumentation     399     Give your plant a HART7 attack                           Advances in HART communication protocol allow users to get more information from their
                                                                                                                   field devices. This additional information includes device diagnostics and notifications, data
                                                                                                                   history, and simulation of digital variables. Come see how easy it can be to take advantage
                                                                                                                   of these improvements, and ensure you get the most value out of your field devices.

Instrumentation Applications. Instrumentation     418     Great Protocols Think Alike - Profibus and Foundation    Jacobs Technology designs and builds wind tunnels for testing virtually anything that moves
                                                          fieldbus Team Up on a Fascinating Application            under virtually any set of environmental conditions. Their designs depend upon very
                                                                                                                   accurate flow measurement and precise drive control for their high powered fans. This paper
                                                                                                                   describes how a recent installation combined the use of Profibus DP for fan drive control
                                                                                                                   and other functions while using Foundation fieldbus for process instrumentation

Instrumentation Applications. Instrumentation     423     Steam Flow Measurement in Cold Climates - New Best
                                                          Practices                                                 Steam flowmeters are often located outdoors in the upstream and downstream
                                                                                                                   hydrocarbon and chemical industries. Accurate flow measurements are needed to maintain
                                                                                                                   process efficiency, detect leaks and account for consumption. Cost-effectively ensuring
                                                                                                                   high accuracy, repeatability and reliability is a challenge, especially in cold climates.
                                                                                                                   Traditional practices are reviewed, followed by new best practices. These new practices
                                                                                                                   have demonstrated improvements in reliability and turndown, at lower initial and life cycle
                                                                                                                   cost. Presented at Canadian School of Hydrocarbon Measurement in Calgary , 2010.

Instrumentation Applications. Instrumentation     428     Keeping a level head for better measurement results      Are you looking for actionable ways to improve your measurement and business results with
                                                                                                                   DP Level systems? This workshop will cover: parameters that have the biggest impact on
                                                                                                                   performance; limitations of old DP Level practices; system selection and specification; and
                                                                                                                   best installation practices including Tuned-Systems Assemblies and Wireless DP Level.

Instrumentation Applications. Instrumentation     431     Tank Level Surprisingly High?                            This paper will discuss the advantages of using radar gauges and level switches to protect
                                                                                                                   tanks from overfilling and causing costly cleanup and environmental damages. It will also
                                                                                                                   cover using the advanced diagnostics in conjunction with AMS to determine the health of
                                                                                                                   the transmitter and validity of the process variable.
Instrumentation Applications. Instrumentation     436     Top 10 Ways to Speed Project Execution with Better       End users and engineering contractors are constantly challenged with project execution to
                                                          Instrumentation Practices                                meet or exceed budget and timelines. But does instrumentation have an impact on project
                                                                                                                   success? This workshop will show you how to specify and quote optimal solutions for your
                                                                                                                   measurement applications, leverage a common platform across multiple applications, and
                                                                                                                   engineer, procure & commission instruments effectively to improve project execution,
                                                                                                                   resulting in faster start-up and reduced costs.
Instrumentation Applications. Instrumentation     438     Can I Detect a Plugged Impulse Line using Advanced       Plugging in pressure measurement impulse lines is an expensive and time-consuming
                                                          Pressure Diagnostics?                                    problem in process plants. Pressure transmitters with HART or Foundation Fieldbus
                                                                                                                   Advanced Diagnostics provide the ability to detect this plugging by monitoring for changes in
                                                                                                                   the process dynamics. Successful implementation of plugged impulse line detection may
                                                                                                                   depend upon numerous factors, including fluid type, primary element, and impulse line state.
                                                                                                                    This workshop will present these various considerations and provide guidance on selecting
                                                                                                                   the best applications for plugged impulse line detection.
Instrumentation Applications. Instrumentation     441     Valero St. Charles Tank Gauging Modernization, Best      Existing tank farms are equipped with old mechanical tank gauges or misapplied process
                                                          Practices                                                radar level transmitters. New demands for more accurate product inventory assessments
                                                                                                                   and better overfill safety require modern equipment.
                                                                                                                     To accommodate an easy migration to new tank gauging systems certain best practices
                                                                                                                   should be followed to save cost and to make the new system conform to established
                                                                                                                   engineering and safety standards.
                                                                                                                     This presentation describes a typical tank gauging system upgrade, the steps needed to
                                                                                                                   make it work properly and the benefits that it brings with it.




                                                                                                Page 67 of 91                                                                                   (Rev. 051010)
                                                                                      2010 Emerson Global Users Exchange
                                                                                                 Workshops


                                                Session
                     Track                                                             Title                                                                           Abstract
                                                   ID
Instrumentation Applications. Instrumentation     456     ERS: Bringing DP Level to New “Heights”                         Keeping up to speed on the latest in measurement technologies and best practices does not
                                                                                                                          have to be as difficult as learning a foreign language. The new Rosemount 3051S
                                                                                                                          Electronic Remote Seal (ERS) system is a digital upgrade to a proven and well-understood
                                                                                                                          technology: DP Level. This paper will build your knowledge on ERS technology while
                                                                                                                          describing the user benefits and considerations for use with other DP Level technologies.

Instrumentation Applications. Instrumentation     490     Inspect Your Gadgets: The Fundamental Features Hidden           Your installed temperature transmitter has features and diagnostics integral to its basic
                                                          Inside Your Temperature Transmitters                            design that can be used to track, mitigate or diagnose process and device abnormalities.
                                                                                                                          These features are fundamental to helping you understand your process variables. Do you
                                                                                                                          know what these features are and how to use them? Discover how to utilize your
                                                                                                                          Rosemount Temperature Transmitters to their fullest abilities, and you can be sure to get the
                                                                                                                          most out of your Single and High Density Temperature Measurement Points!

Instrumentation Applications. Instrumentation     496     I can't believe it's not balanced.... A better way to measure   Are you having difficulties getting your DP Level measurement system to perform the way
                                                          level.                                                          you expect? This paper will discuss types of measurement error in DP level systems and
                                                                                                                          provide a clear roadmap for improving overall system performance.
Instrumentation Applications. Instrumentation     498     The RIGHT way to do Temperature: Best Practices for
                                                          Installation, Commissioning, and general Temperature               With over 50 years of experience helping customers install and maintain their temperature
                                                          measurement                                                     equipment we've documented some real behaviors that can help decrease installation time,
                                                                                                                          prevent future maintenance and give you more confidence in your Temperature
                                                                                                                          measurements. This workshop will outline the practical things YOU can do to improve and
                                                                                                                          simplify your overall temperature operations.
Instrumentation Applications. Instrumentation     509     Smart Field - does instrumentation really matter?               The future is here, today. We've crossed the chasms together; pneumatic to analog, analog
                                                                                                                          to smart, wired to wireless. Today we have instruments with more computing power than the
                                                                                                                          first controller. The question is, are we using technology in a meaningful way, or more
                                                                                                                          importantly in a way that has a positive business result? This course will explore the benefits
                                                                                                                          of a Smart Field and the potential business results.
Instrumentation Applications. Instrumentation     533     2120 as a direct replacement for a float switch integrating     This customer wanted to use a 2120 as a direct replacement for a float switch and bring the
                                                          directly into a Honeywell TDC 3000                              input directly into their Honeywell TDC 3000 without reconfiguring any hardware and utilize
                                                                                                                          the exisiting Digital Input card. The utilization of vibrating fork level switches aligns with the
                                                                                                                          philisophy of replacing mechanical devices with devices that are capable of increasing
                                                                                                                          safety and reliability while reducing maintenance costs and increase production through
                                                                                                                          diagnostic capabilities of the switch, and the testing ability available on the 2120 while still in
                                                                                                                          service.

Instrumentation Applications. Instrumentation     537     Geothermal Industry Needs Accurate Level for NCG                In the geothermal industry at production wells, reliable and accurate level measurements
                                                          Separators                                                      are critical in non-condensable gas (NCG) separators for efficient operations and to prevent
                                                                                                                          booster pump damage and shutdown of operations. High level would result in carryover
                                                                                                                          and system damage and inefficiencies. Low level would cause booster pump damage and
                                                                                                                          downtime. The innovative Rosemount high temperature/high pressure guided wave radar
                                                                                                                          probe is perfect for our operating conditions.

Instrumentation Applications. Instrumentation     127     Reducing Bias and Uncertainty in Process Gas Quality            Ensuring robust measurements of natural gas quality is a combination of good sampling, a
Analytical                                                Measurements                                                    properly validated gas chromatograph and a traceable calibration gas. Omitting any of
                                                                                                                          these key elements will result in biased measurements of composition and hence the
                                                                                                                          calculated physical properties of heating value, density and Wobbe Index. Even small
                                                                                                                          errors over time will result in large financial discrepancies, particularly at fiscal metering
                                                                                                                          points with a large throughput.




                                                                                                   Page 68 of 91                                                                                          (Rev. 051010)
                                                                                     2010 Emerson Global Users Exchange
                                                                                                Workshops


                                                Session
                     Track                                                            Title                                                                       Abstract
                                                   ID
Instrumentation Applications. Instrumentation     289     Simplified Gas Chromatograph Installations & Operations      Gas chromatographsarevaluable analytical tools in many plant and pipeline operations.
Analytical                                                with Foundation fieldbus                                     Their installations and operations though are often considereddifficult and labor intensive.
                                                                                                                       The 700XA and 1500XA gas chromatographs fromEmerson Process
                                                                                                                       Management'sRosemount Analytical change this perception, utilizing a Foundation fieldbus
                                                                                                                       interface - the world's first and only certified Foundation fieldbus interface on a gas
                                                                                                                       chromatograph.
Instrumentation Applications. Instrumentation     368     Implementing Hybrid First-Principles/Empirical Models for    A model pharmaceutical system controlled by Delta V and SynTQ was used to show
Analytical                                                Pharmaceutical Manufacturing through Automated Controls      enhancements to a fluid bed drying process. It used a first-principles model and direct
                                                                                                                       measurements of CQAs (water content) to reduce time/energy required for the process, and
                                                                                                                       reduced variability. DeltaV controlled the fluid bed dryer, SynTQ coordinated data collection
                                                                                                                       and analysis from multiple univariate and spectroscopic systems. Further, SynTQ passed
                                                                                                                       the conditioned data to the analytical and control models and reported desired set points to
                                                                                                                       the DeltaV system. This system serves as a model for future manufacturing in the
                                                                                                                       pharmaceutical industry.
Instrumentation Applications. Instrumentation     449     Discrete Control Solutions using Mulit-parameter Analyzers   This paper addresses the chemical concentration control and dosing using the discrete
Analytical                                                                                                             funtionality inmultiparameteranalyzers. It addressesinterfacewith the control system and
                                                                                                                       AMS and use of wireless communcation in these applications which include plant utilities
                                                                                                                       and skids.
Instrumentation Applications. Instrumentation     536     Challenges of integrating anayzers systems in Integrated     Whiel automation is rapidly converging where many diverse systems are sharing common
Analytical                                                Process Control                                              platforms and automation resources; however the analytical systems are lagging behind and
                                                                                                                       thus face underutilization of their capabiliites of process controls, and being treated like
                                                                                                                       black boxes. The interface and diverse technolgies add to the complexity of integration.

Instrumentation Applications. Instrumentation     61      Improving Measurement Quality and Efficiency using Coriolis Sonacol is a Chilean oil pipeline operator with a 700 km network for refined products
Flow                                                      Technology                                                  (LPG, diesel, gasolines, etc.)The company is owned by top the leading companies of the
                                                                                                                      fuel sector in Chile . Total production amounts to approximately 5.000.000 m3/year.

Instrumentation Applications. Instrumentation     89      Coriolis Meters: Changing the Marine Bunker Fuel Industry    Accurate measurement of heavy fuel oil bunkering can save thousands in accurate billing
Flow                                                                                                                   and reduced operating expense. The bunker fuel industry is challenged converting
                                                                                                                       volumetric to mass measurement due to many variables, though mass measurement
                                                                                                                       provides the certainty needed. Coriolis mass measurement provides a more accurate and
                                                                                                                       cost effective fuel bunker measurement and is changing the way the Bunker industry
                                                                                                                       handles HFO. Bunker barge operators now deliver accurate quantities of fuel while the
                                                                                                                       vessel operators are certain they are getting the quantity and quality of fuel they are buying.

Instrumentation Applications. Instrumentation     100     Fiscal and Allocation Measurement Philosophy for a Ultra
Flow                                                      large Refinery in Asia using Over Eighty Liquid Ultrasonic    The use of Liquid Ultrasonic Meters for liquid petroleum applications such as fiscal or
                                                          Meters – A Case Study                                        allocation measurement is gaining world wide acceptance. Ultrasonic technology is an
                                                                                                                       established technology but the use of this technology, for custody transfer is relatively new.


                                                                                                                         Often users try to employ the same measurement practices that apply to turbine technology
                                                                                                                       to the Liquid Ultrasonic. .
                                                                                                                           .
Instrumentation Applications. Instrumentation     112     Pipe Dreams: Save Money and Improve Measurements with        Would you like to have the best of both worlds in flow measurement? Here is how to save
Flow                                                      Compact DP Flow Technology                                   money and improve the performance of your flow measurement points at the same time.
                                                                                                                       Compact DP Flowmeter designs make it possible to reduce equipment and installation
                                                                                                                       costs, eliminate potential leak points, reduce piping requirements and improve flowmeter
                                                                                                                       performance. This course will demonstrate how to take advantage of the latest innovations
                                                                                                                       in Compact DP Flowmeter technology.




                                                                                                  Page 69 of 91                                                                                     (Rev. 051010)
                                                                                     2010 Emerson Global Users Exchange
                                                                                                Workshops


                                                Session
                     Track                                                             Title                                                                        Abstract
                                                   ID
Instrumentation Applications. Instrumentation     200     40 CFR 98 Tier 4 Greenhouse Gas Reporting with Stack           The EPA's Greenhouse Gas Mandatory Reporting Requirements (GHG-MRR) drive process
Flow                                                      Emissions Flow Meter                                           industry end-users to greatly expand their measurement and reporting capabilities. Those
                                                                                                                         choosing or required to report using "Tier 4" methodology may need to upgrade or add a
                                                                                                                         stack volumetric flow meter to their Continuous Emissions Monitoring Systems (CEMS).
                                                                                                                         This paper describes how to achieve accurate annual emissions reporting with this method
                                                                                                                         by evaluating the installation, performance, calibration and maintenance considerations for
                                                                                                                         such a flow meter.
Instrumentation Applications. Instrumentation     226     1Impact of Impulse Line Induced Lag-time in DP Flow            Modern gas flow measurement continues to be dominated by use of the orifice plate. Effort
Flow                                                      Measurement                                                    to improve measurement performance using this technology has spanned more than 60
                                                                                                                         years. Performance is affected by many factors: distance between the measurement point
                                                                                                                         and upstream and downstream piping components, DP transmitter selection, accurate
                                                                                                                         gauging and centering of the bore hole as well as many others. Little regard is given to
                                                                                                                         impulse line diameter and length and the impact these choices make on the measurement
                                                                                                                         performance.
Instrumentation Applications. Instrumentation     324     Arkema Refrigerant Producer Reduces Cost to Comply with        Arkema is using Emerson technology to provide reporting of greenhouse gas production at
Flow                                                      EPA Greenhouse Gas Reporting Rule Using Micro Motion           its refrigerant production facility in Kentucky. The rule presents challenges of measurement
                                                          Coriolis Meters with Meter Verification, AMS, and Wireless     accuracy, calibration and record-keeping requirements. EPA demands tight accuracy and
                                                          Technologies                                                   Arkema desires to minimize the possibility of over-reporting production and emissions.
                                                                                                                         Initial implementation and recurring cost to comply with the regulation will be reduced
                                                                                                                         significantly.
Instrumentation Applications. Instrumentation     333     Danisco’s Implementation of GWR in Liquid Nitrogen             Liquid nitrogen tank level problems forced Danisco's Chuck Harter to assign an operator to
Flow                                                      Reactor Enables Automation and Maximizes Process               monitor every 4-hour batch. The goal was to prevent overfills and low levels which can
                                                          Efficiency                                                     cause facility damage or shutdowns as the agitation, boiling and coating caused the current
                                                                                                                         float problems. Maintenance and safety concerns caused Danisco to turn to GWR for a
                                                                                                                         solution. Use of GWR and stilling well ensured a robust signal from tank conditions and
                                                                                                                         tank trays. GWR now gives Danisco control within 2% of span, eliminates the need for an
                                                                                                                         operator at tank side, and maximizes uptime.
Instrumentation Applications. Instrumentation     334     Using Instrument Diagnostics to Reduce the Cost of             Today's Magnetic Flow Meters are able to provide users with advanced
Flow                                                      Regulatory Compliance in the W&WW Industry                     diagnostic information to better manage their processes and reduce the cost of Regulatory
                                                                                                                         Compliance. One of these diagnostics is SMART Meter Verification capability. The SMART
                                                                                                                         Meter Verification diagnostic provides a means of verifying magmeter health without
                                                                                                                         requiring a process shutdown or removal of the flowtube sensor. This continuously running
                                                                                                                         diagnostic monitors critical parameters of the transmitter and flowtube sensor to provide
                                                                                                                         users with a means of documenting the health of their magmeter system.

Instrumentation Applications. Instrumentation     342     Improvements to Separator Control and Availability at Eli Lilly The Eli Lilly processing plant in Clinton, Indiana needed to optimize a solvent recovery
Flow                                                      Using Micro Motion Two-Wire Coriolis                            process through greater flow measurement accuracy and reliability. But we did not have the
                                                                                                                          power wiring available for installation of powered 4-wire flow meters. Our need was satisfied
                                                                                                                          through the installation of a 2-wire coriolis flow meter from Micro Motion. This installation
                                                                                                                          has lead to improved flow accuracy, better control, improved quality and reduced production
                                                                                                                          cost. Additionally, we expect significant ongoing savings from reduced maintenance costs
                                                                                                                          and process availability.
Instrumentation Applications. Instrumentation     369     Cold Climate Flow Measurement: Advantages,                      Cold climate process plants can simplify their flow measurement installations by choosing a
Flow                                                      Compromises, and Challenges of Vortex Meter                     less traditional, but more cold-weather friendly technology in Vortex Metering. For
                                                          Implementation                                                  Consumers' Cooperative Refineries Limited (CCRL) in Regina, Saskatchewan, this is the
                                                                                                                          metering device of choice at its current facilities, and also for a major expansion to be
                                                                                                                          completed in 2012.




                                                                                                  Page 70 of 91                                                                                      (Rev. 051010)
                                                                                     2010 Emerson Global Users Exchange
                                                                                                Workshops


                                                Session
                     Track                                                            Title                                                                       Abstract
                                                   ID
Instrumentation Applications. Instrumentation     393     DP Flow for Dummies: Common Mistakes to Avoid                 Engineering DP Flow requires effort and experience. Mechanical and electrical components
Flow                                                                                                                    must be put together in just the right way in order to meet the application requirements and
                                                                                                                        avoid errors. This has resulted in common and sometimes comical mistakes. This guide is
                                                                                                                        for anyone who wants to get more out of flow measurement by learning from the experience
                                                                                                                        of others.
Instrumentation Applications. Instrumentation     397     Don't Let Steam Measurement Get You Hot Under Your            Steam is a common yet challenging fluid for flow measurement. The high temperatures and
Flow                                                      Collar                                                        potential for two-phase measurement create potential for error and challenge reliability.
                                                                                                                        Steam measurement is also related to energy consumption. This paper compares and
                                                                                                                        contrasts metering technologies used for steam and suggests techniques for improving and
                                                                                                                        reducing the cost of steam measurement.
Instrumentation Applications. Instrumentation     398     Advantages of Two Phase Flow Metering using Roxar             Using data from testing at Micro Motion's facility in Boulder, this paper presents how Roxar
Flow                                                      Watercut Meters Together with Micro Motion Coriolis Flow      Flow Measurement and Micro Motion are developing innovative solutions for a number of
                                                          Meters and Future Potential                                   two phase flow measurement applications which can be supplied as a standalone two phase
                                                                                                                        metering package to a fully integrated fiscal metering station or other larger metering scope
                                                                                                                        using a wide range of Emerson products. Applications that will benefit from an integrated
                                                                                                                        metering solution include: Production measurement (net oil), Allocation and Fiscal
                                                                                                                        measurement for custody transfer, loading and export metering.

Instrumentation Applications. Instrumentation     401     Innovative Technologies for Meeting GHG Monitoring
Flow                                                      Requirements                                                   As of Jan. 1, 2010, facilities that produce more than 25K metric tons of CO 2 e /year, must
                                                                                                                        monitor and report GHG emissions. All petroleum refiners are required to report GHG
                                                                                                                        emissions regardless of the amount produced. One of the more onerous stipulations of the
                                                                                                                        rule was the decision to treat refinery fuel gas (RFG) as a Tier 3 fuel which is subject to
                                                                                                                        more stringent requirements for measurement and calibration than either Tier 1 or 2 fuels.
                                                                                                                        These requirements include the use of P & T compensation at each flow measumement
                                                                                                                        point and inspection of the primary flow element at least once everythree years.

Instrumentation Applications. Instrumentation     402     Don't Drown in Wet Gas: Wet Gas Flow Measurement with       Several types of differential pressure flowmeters are currently being used in wet gas flow
Flow                                                      DP Flow                                                     measurement. This paper will present test data from various DP flowmeters and discuss the
                                                                                                                      current research in wet gas flow measurement. Videos of various wet gas flows will be user
                                                                                                                      for illustration purposes.
Instrumentation Applications. Instrumentation     460     Remote Steam Monitoring for District Energy Distribution    Enwave Energy Corporation is the largest district energy company in Canada and one of the
Flow                                                                                                                  largest in North America. We provide low cost, environmentally-friendly heating and cooling
                                                                                                                      to more than 140 commercial, institutional and multi residential buildings in the cities of
                                                                                                                      Toronto and Windsor, Ontario.
                                                                                                                      Rather than heating and cooling buildings with in-house boilers and chillers, district energy
                                                                                                                      customers get their heating and air conditioning via underground pipe distribution networks
                                                                                                                      that are connected to one or several large plants.
Instrumentation Applications. Instrumentation     487     Use of Ultrasonic Flowmeters in Liquefied Natural Gas (LNG) Traditionally, LNG has been traded on the basis of long term contracts with volume
Flow                                                      Custody Transfer Applications – New Challenges, New         measurement being done using static tank gauging. This approach has served the industry
                                                          Solutions                                                   well, however as LNG is traded more on the basis of short term contracts, it is anticipated
                                                                                                                      that dynamic flow measurement at the point of unloading will become more prevalent,
                                                                                                                      similar to the custody transfer of oil shipments. Liquid ultrasonic flowmeters will be a
                                                                                                                      technology of choice in these applications
Instrumentation Applications. Instrumentation     520     DTE Energy maximizes Emerson’s ControlWave Micro Flow DTE Energy implements Emerson's ControlWave Micro to provide accurate gas flow
Flow                                                      Measurement capability to increase Accuracy and reduce      measurement on multiple meter runs by auto selecting the ultrasonic meter with the best
                                                          Operational Cost                                            flow profile. The CWM also allows DTE to determine when re- calibrations are required by
                                                                                                                      constantly monitoring the current flow profile versus the meter's initial flow profile. This
                                                                                                                      reduces the cost of lost gas and unneeded calibrations trips to the field. DTE has also utilize
                                                                                                                      the full functionality of the CWM at these stations which replaces multiple devices with one
                                                                                                                      unit leading to a result of a reduction in operational cost.




                                                                                                 Page 71 of 91                                                                                     (Rev. 051010)
                                                                 2010 Emerson Global Users Exchange
                                                                            Workshops


                            Session
                    Track                                         Title                                                                         Abstract
                               ID
Maintenance & Reliablity       81     Emerson Fieldbus Device Testing – Interoperability Assured     DeltaV goes beyond the Fieldbus Foundation's (FF) Interoperability Tests (ITK) in order to
                                                                                                     assure device/master interoperability. The FF testing assures everyone that a fieldbus
                                                                                                     device conforms to the FF Function Block (FB) and Transducer Block Specifications, but it
                                                                                                     does not test the physical layer of the device or reconcile some differences in the
                                                                                                     interpretations of the FF specifications. Emerson's testing includes real world scenarios and
                                                                                                     feedback from actual incidents.
Maintenance & Reliablity      128     Online vibration monitoring of boiler feedwater pumps          This presentation covers the installation and results of using an online vibration monitoring
                                                                                                     system. The application involves 4 boiler feedwater pumps in a 65 MW peaking plant. Plant
                                                                                                     burnsapprox. 15%wood and 85%coal. .
Maintenance & Reliablity      140     Stop Playing Maintenance Guessing Games with Radar             Guided Wave Radar transmitters with Signal Quality Metrics (SQM)diagnostics can monitor
                                      Level by using Advanced Signal Quality Diagnostics             for unwanted changing surface conditions or for build-up on probe.SQM give an indication of
                                                                                                     how good the surface signal is compared to noise and how much disturbance the device
                                                                                                     can handle in the tank.SQM can be assigned to transmitter variables and sent to the control
                                                                                                     system to trigger an alarm. These capabilities enable preventative maintenance to clean the
                                                                                                     probe and provide better process control by identifying abnormal surface conditions and
                                                                                                     preventing overfills.
Maintenance & Reliablity      169     Koch Nitrogen finds standardization across platforms brings    Koch Nitrogen's five North American production facilities faced a familiar issue within
                                      efficiencies and improved productivity                         industry today regarding obsolescence of existing continuous online vibration monitoring
                                                                                                     platforms. Couple this fact with a lean labor force and varying experience from plant to plant,
                                                                                                     the five plants operated as stand alone islands in regards to mechanical asset health. We
                                                                                                     will examine how Koch Nitrogen methodically went about defining, evaluating, performing
                                                                                                     the front end engineering design(FEED), and implementation of a standardized multi plant
                                                                                                     online vibration monitoring platform retrofit and upgrade.

Maintenance & Reliablity      175     Weathering the Storm Using Grounding Best Practices and        Lightning provides stunning views from afar, but no one wants to be caught between its
                                      Transient Protection for Radar Level                           energy and the ground, including radar transmitters. Various human-made and natural
                                                                                                     events produce excess transient energy that can enter level transmitters via multiple paths.
                                                                                                     This excess energy can damage device electronics resulting in costly field failures and
                                                                                                     unplanned downtime. It is critical to use devices with built-in transient protection and equally
                                                                                                     essential to follow proper grounding methods. Also special consideration must be made to
                                                                                                     create a low resistance ground path and avoid ground loops.

Maintenance & Reliablity      253     Alternative Energy: Online Vibration Monitoring of Three       Colbun is a private Chilean company with 1.3MW of installed capacity in Hydro and with
                                      Hydroelectric Power Plants in Chile                            coal and GNL plants distributed across the country. In this application, it is detailed the
                                                                                                     engineering process and results obtained when implementing predictive condition
                                                                                                     monitoring at three hydro plants.
Maintenance & Reliablity      254     Ormen Lange knowing that every valve will be OK tomorrow-      At Shell's North Sea Ormen Lange onshore processing plant for the subsea gas field at
                                      how do they do it                                              Aukra, Norway, online diagnostics from more than 350 continuously monitored valves supply
                                                                                                     critical information to operations locally at Aukra, and in addition to maintenance and
                                                                                                     reliability personnel at the remote Shell headquarter in Kristiansund and the Fisher
                                                                                                     representative Solberg & Andersens valve diagnostic center in Bergen. Gathering
                                                                                                     knowledge and shearing the info is a key in the success.
Maintenance & Reliablity      268     Soup to Nuts: Turnkey Solution Offer Full-Service Innovation   When Tesoro's Kenai refinery planned a large scale turnaround involving both valve and
                                      for Increased Reliability                                      instrumentation work, they faced the daunting task of assembling technicians with skills to
                                                                                                     handle this multi-faceted project. This presentation will demonstrate how Emerson built on
                                                                                                     the knowledge of their proven turnaround process to provide a single source solution;
                                                                                                     bringing technicians with capabilities in multiple crafts to the job. As a result of turnkey
                                                                                                     services, Tesoro has received process efficiency benefits of improved valve performance
                                                                                                     and increased reliability of the safety shut down system.




                                                                             Page 72 of 91                                                                                         (Rev. 051010)
                                                                2010 Emerson Global Users Exchange
                                                                           Workshops


                            Session
                    Track                                        Title                                                                   Abstract
                               ID
Maintenance & Reliablity      272     No Time? No Problem! Chevron's Largest Turnaround        Chevron's El Segundo, CA, planned meticulously for the largest turnaround in its 125-year
                                      Delivered Despite Shortened Schedule                     plant history. Upset conditions in an adjacent unit required plant personnel to focus their
                                                                                               efforts elsewhere just as the outage began. Despite the compressed schedule and
                                                                                               additional work, Emerson technicians were able to revise prioritization and offer multiple
                                                                                               paths for outage success, supporting all scope changes in the shop and field. This paper
                                                                                               will demonstrate how proper planning and constant communication insured on-time
                                                                                               completion with accurate documentation, even when timelines were condensed.

Maintenance & Reliablity      277     Luminant's Root Cause Analysis Solves Downtime Dilemma   Luminant's Monticello high volume plant was experiencing sporadic control valve issues
                                      and Increases Life Cycle Efficiency                      which extended downtime, costing the plant lost revenue. This paper will demonstrate how
                                                                                               determining the root cause of unexpected shutdowns provided a path towards repair
                                                                                               parameters and diagnostic techniques which can be used to make proactive maintenance
                                                                                               decisions. The increased life cycle efficiency and expanded duration of time between valve
                                                                                               related outages has allowed for more effective power generation.
Maintenance & Reliablity      314     Creative Use of Predictive Maintenance Technologies      In 2005 Koch Fertilizer Canada embarked on a capital project to shift from a Reactive
                                                                                               maintenance culture to a more Predictive Maintenance strategy. Emerson's Asset
                                                                                               Optimization Division was selected by Koch Fertilizer Canada as the primary provider of
                                                                                               predictive maintenance services and products for mechanical and process equipment

                                                                                               Two of the technologies utilized in Koch's predictive maintenance strategy are Vibration
                                                                                               Analysis and Infrared Thermography. Koch's maintenance team has discovered some
                                                                                               relatively new applications for these technologies


Maintenance & Reliablity      326     COST SAVINGS REALIZED USING LARGER DIAMETER              EVALUATION OF THE COST SAVINGS ACHIEVED USING TUBING, VALVES AND
                                      TUBING & MECHANICAL FITTINGS VS. TRADITIONAL             FITTINGS VS. THE TRADITONAL METHODOLOGY OF SCREWED, WELDED AND
                                      METHODS                                                  FLANGED PIPING SYSTEMS 2" & UNDER FOR PROCESS, UTILITIY AND R&D
                                                                                               APLICATIONS.
Maintenance & Reliablity      403     Reduce Cost and Risk Using Best-in-Class Calibration     By partnering with Emerson, Merck has implemented best-in-class calibration practices that
                                      Practices                                                have led to substantial cost savings. Other Life Sciences businesses, among them Bristol-
                                                                                               Myers Squibb (BMS), are adopting these same practices. This paper describes how Merck
                                                                                               established the validity of the instrument technology improvements and developed new best
                                                                                               practices for purchasing and maintaining pressure and temperature instruments. It will also
                                                                                               describe how BMS developed risk-based recalibration intervals.

Maintenance & Reliablity      404     Foundation Fieldbus Error Detection & Diagnostics        Foundation Fieldbus is not a fully redundant system, and it must rely on a combination of
                                                                                               fault tolerance, fault isolation, and failure detection to ensure reliable operation. While
                                                                                               counting communications errors can be one method to identify fieldbus problems, it can be
                                                                                               too late. Measurement of three key fieldbus physical layer parameters can provide early
                                                                                               detection of problems in the fieldbus system prior to communications errors and avoid costly
                                                                                               unplanned disruptions in the fieldbus communications.

Maintenance & Reliablity      432     How to Set Up Plugged Impulse Line Advanced Pressure     Plugging in pressure measurement impulse lines is a significant, costly, and resource-
                                      Diagnostics using Foundation Fieldbus                    consuming problem in process plants. Foundation fieldbus pressure transmitters with
                                                                                               Advanced Diagnostics Suite provides the capability to detect this plugging in the impulse
                                                                                               lines, and notify operations or maintenance of the issue. Historically, there has been
                                                                                               confusion and uncertainty regarding proper configuration of plugged impulse line (PIL)
                                                                                               diagnostics. This workshop will provide guidance on how to best utilize this advanced
                                                                                               pressure diagnostics function.




                                                                            Page 73 of 91                                                                                 (Rev. 051010)
                                                                 2010 Emerson Global Users Exchange
                                                                            Workshops


                            Session
                    Track                                          Title                                                                        Abstract
                               ID
Maintenance & Reliablity      450     Orica experience with the linkage-less, non-contact         Orica Mining Services participated in the field trial program for the linkage-less, non-contact
                                      positioner in liquid ammonia application.                   explosion proof positioner. Orica Mining Services, Kooragang Island is the second
                                                                                                  biggest industrial Ammonium Nitrate producing site in the world. This paper will cover the
                                                                                                  experience with this new technology.
Maintenance & Reliablity      463     Performance Diagnostics Solves Process Instability Problem, Nexen, an operator in the Athabasca oil sands region of Alberta , was experiencing a
                                      Yields Improved Control                                     control issue on asteam generator boiler feedwatercontrol valve. Several attempts to
                                                                                                  correct the process oscillations through valve characteristic and control methodology
                                                                                                  changes yielded no results. Through the implementation of Performance Diagnostics tier
                                                                                                  on the existing DVC6000, valuable insight was provided to the operators which highlighted
                                                                                                  the need for a change to the physical valve construction to yield a solution to the control
                                                                                                  issue.
Management                    12      Ban the Bullet Point!                                       Have you ever sat through a really boring presentation? Have you ever given one? Odds are
                                                                                                  the answer to both of those questions is YES! Making your presentation interesting,
                                                                                                  effective, and memorable can be challenging. This session will give you concrete tips and
                                                                                                  tricks to make your presentations better.
Management                    40      You Too are Selling - How to Sell Your Ideas Internally     We all have great ideas, and we want so see them implemented in our organizations.
                                                                                                  Whether it's to try the latetest wireless technology or completley modernize the DCS system,
                                                                                                  we know it's the right thing to do for our companies. The problem is getting the resources
                                                                                                  and money to make it happen. In this session we will walk through the basics steps of
                                                                                                  identifying hte bussiness case, developing the justification, understaning the approval
                                                                                                  process, and finally the presentation to secure the funding and resources to make your
                                                                                                  ideas a reality.
Management                    48      Process Automation System Lifecycle Managment and           Users of process automation systems struggle with the issue of determining when the useful
                                      Migration                                                   life of their system is over. It is equally challenging to determine when to migrate to new
                                                                                                  technology, and whether to adopt a phased approach or a vertical big bang approach. This
                                                                                                  presentation will show the current state of the industry as it relates to control system
                                                                                                  migration and lifecycle management and how it relates to best practices.


Management                    74      The “Smart” Plant of the Future                            We see daily the rapid advances in computing and communication and the ways is which
                                                                                                 these advances have changed the way we live and work. Advances in sensor, automation,
                                                                                                 and information technology, based on these advances, have significantly changed the way
                                                                                                 process plants operate and will cause continuing change in the future, leading to what is
                                                                                                 termed "The Smart Plant". In this presentation, case studies on actual implementations,
                                                                                                 recent advances in relevant technologies and probable trends in the business environment
                                                                                                 are used to forecast likely future changes.
Management                    183     Tech Lead as Mentor - What? I’m too busy for that!         Many times, experienced engineers are tasked with tech lead roles on projects as a result of
                                                                                                 their technical proficiency. In the ideal case, all requirements are available at the start of the
                                                                                                 project and the role of tech lead is reduced to high-level design and supervisory tasks. In the
                                                                                                 real world case, project inputs can be delayed or subject to rapid change. These challenges
                                                                                                 can be used to proactively support the development of your team's skills. This workshop will
                                                                                                 present methods for developing the members of your team, while maintaining focus on
                                                                                                 project and organizational objectives.
Management                    355     Business Case for the Assessment of DeltaV and Wireless in When we assess oil and gas projects today, where do we start? How do we assess if a
                                      Oil and Gas Greenfield and Brownfield Projects             project is viable or economical? Do we focus on whether the project will be designed and
                                                                                                 constructed in the same manner and fashion as it has been done before or will we look to
                                                                                                 the future? Technology today and even future technology allows us to think laterally, to
                                                                                                 expand our minds and to dream what could be possible and achievable. With Greenfield
                                                                                                 and Brownfield projects, what decisions do we take to ensure that we operate and man
                                                                                                 these facilities in the most efficient and economic manner possible?




                                                                              Page 74 of 91                                                                                      (Rev. 051010)
                                                                    2010 Emerson Global Users Exchange
                                                                               Workshops


                               Session
                       Track                                         Title                                                                        Abstract
                                  ID
Management                       467     Meridium and Emerson partnership helps improve plant          Align asset strategies with management objectives to satisfy key business drivers in your
                                         availability and performance through enhanced asset           asset improvement initiative. Learn how a model that brings together real-time asset
                                         management                                                    information with critical management systems while applying well-known maintenance
                                                                                                       practices produces sustainable results in asset performance.
                                                                                                            This presentation will show how others have been incredibly successful in revitalizing
                                                                                                       their businesses by using a holistic, integrated approach to asset performance management.

Management                       494     How an Alliance with Emerson Can Increase Value Delivered LyondellBasell Industries is one of the world's largest polymers, petrochemicals and fuels
                                                                                                   companies. Emerson is one of the world's largest industrial manufacturing solutions
                                                                                                   providers. Aligning two large and complex organizations takes some critical thinking,
                                                                                                   planning, and execution. This Paper will discuss the history of our business relationship and
                                                                                                   how it evolved into an alliance achievingmutual business wins.
Management                       529     Human-Centered Design of Operations: From the Inside Out Often the term 'human-centered design' (HCD) is used only when companies discuss
                                                                                                   automation. However, effective HCD for operations is more than designing 'user-friendly'
                                                                                                   automation. HCD applies to the design of the operations organization and work processes,
                                                                                                   console job complexity, field operator utilization, the alarm system and DCS operator
                                                                                                   interface, the console and control room, individual and team training, and the procedure
                                                                                                   system. For all of these, HCD involves identifying the proper requirements, iterative design
                                                                                                   with end users, and effective lifecycle work processes.
Process Optimization             57      ultivariable Control in DeltaV using LQG                  In this submission, multivariable control of the merox process at Preemraff Refinery in
                                                                                                   Lysekil Sweden is presented using the LQG algorithm programmed in DeltaV.
                                                                                                    The merox process is for elimination of sulphurous impurities in the Liquid Petroleum Gas
                                                                                                   (LPG) stream from the refinery?s fluid catalytic cracker. The process comprises a counter
                                                                                                   current amine tower and caustic wash vessel, extraction tower, separation and filtration unit.
                                                                                                    The whole unit is liquid filled. Control valves on liquid streams in the process control flow,
                                                                                                   pressure and liquid interface level.
Process Optimization             84      Sustaining and Extending Advanced Control Value in an     Goodyear had previously completed an Advanced Process Control (APC) project on a
                                         Operating Plant                                           distillation column in its C5 refining unit which resulted in significant savings. This project
                                                                                                   was designed and led by Emerson consultants with Goodyear engineers working/training
                                                                                                   under the consultants.
                                                                                                   In continuation of the unit optimization effort, an APC multicolumn project has been
                                                                                                   completed with Goodyear engineers leading and implementing the project. This paper will
                                                                                                   discuss the APC technology implemented in the second project, the resulting benefits, and
                                                                                                   also the ongoing efforts to maintain the APC models

Process Optimization             108     PredictPro Reduces Energy Consumption and Emissions at        A control loop audit at MOL's Algyo gas plant highlighted the opportunity for optimisation of
                                         MOL, Algyo Gas Plant                                          the distillation column controls using advanced control strategies which can cope with feed
                                                                                                       and product quality spec changes.

                                                                                                       MOL selected the advanced control tools embedded in their DeltaV DCS, PredictPro. The
                                                                                                       implemented solution included a combination of advanced regulatory control, model
                                                                                                       predictive control and inferential analyses of product qualities.

                                                                                                       The project resulted in a US$ 1.7million saving in fuel usage, with associated reduction in
                                                                                                       CO2 emissions, and improved on-spec production.




                                                                                Page 75 of 91                                                                                      (Rev. 051010)
                                                                   2010 Emerson Global Users Exchange
                                                                              Workshops


                               Session
                       Track                                         Title                                                                      Abstract
                                  ID
Process Optimization             134     Solving Loop Interactions in a New LNG Train Using          Emerson consultants assisted startup of a large LNG train on PlantWeb. We quickly fixed
                                         Combined Emerson Tools                                      hundreds of loop problems by using simultaneously Emerson tools embedded in DeltaV or
                                                                                                     added on to an Application Station. Examples are from various process units: Utilities,
                                                                                                     Fractionation, Sulfur Recovery, and Cryogenic. We emphasize interactions between the
                                                                                                     levels, flows, pressures, and temperatures and their decoupling by the Lambda Tuning
                                                                                                     method. The plant saved several days of startup time and also saw improvements in
                                                                                                     product quality, efficiency, and stability.
Process Optimization             155     Tête-à-tête with the Operators, A DeltaV Messaging System   DeltaV graphics and alarms aren't the only way to communicate with an operator. Come see
                                         that Works                                                  how a messaging system provides a way to get supervisor permission, prod operators to
                                                                                                     take action, provide recurring reminders, and give automation progress updates no matter
                                                                                                     what screen is being viewed. For large-scale applications, this system can dramatically
                                                                                                     improve communication and conduct of operations. Presentation concentrates on
                                                                                                     implementation of this system.
Process Optimization             167     Batch Process Analytics (PA) – An In Depth Update
                                                                                                       In-depth look at the needs and limitations of on-line batch Process Analytics (PA). The
                                                                                                     practical and useful findings from the work of Lubrizol and Emerson for advancing on-line
                                                                                                     batch PA following completion of a successful field trial. Principles of multivariate analysis
                                                                                                     will be shown as well as a web interface for on-line PA. Advantages of PA for addressing
                                                                                                     the limitations of traditional monitoring will be discussed. Additional process insight provided
                                                                                                     by PA as well as having real time batch product quality capability will be shown.

Process Optimization             171     Making Operations Predictable Through Automation; The       Poor plant process control resulting in excessive process variability can cause equipment
                                         True Cost, Causes and Cures of Process Variability          reliability problems as well as poor product quality and excessive operating costs. These
                                                                                                     problems can be due to external disturbances, or the performance of measurements,
                                                                                                     valves, or control algorithms. Identifying the cause and economically justifying the
                                                                                                     automation investments required to correct these problems and decrease process variability
                                                                                                     is the subject of this presentation.
Process Optimization             173     Quick Hit Financial Benefit of SmartProcess Application     The Oil Refining industry is faced with a challenging economic environment which has led to
                                                                                                     a high emphasis on cost reduction and cash flow management. Investment in costly
                                                                                                     strategic initiatives does not fit the economic model to generate a positive cash flow in the
                                                                                                     near term. Implementation of a SmartProcess Distillation solution provides the opportunity
                                                                                                     to invest in improving process yield and energy on a smaller scale. With these strategically
                                                                                                     targeted APC applications, cash payout can be realized in months without a complicated
                                                                                                     infrastructure, interface or additional console displays.
Process Optimization             228     APC – Where to Use It                                       Companies in all types of industries have reported remarkable benefits from implementing
                                                                                                     Advanced Process Control (APC) on a wide variety of processes, from bio reactors to
                                                                                                     refinery crude columns. With the advent of embedded DeltaV APC tools, the cost for
                                                                                                     implementing and supporting APC applications has never been less. But many sites still
                                                                                                     struggle to take advantage of the APC capability built-in to DeltaV. It's often difficult to
                                                                                                     identify where the technology might be used in a high-impact way. This session will address
                                                                                                     the question of where to look to find killer APC applications.
Process Optimization             237     Temperature Expert Control System for a Copper Smelter      The copper smelter in Southern Peru is one of the World's largest. It smelts concentrate
                                         Furnace at Southern Copper Corporation (SCC)                produced from Peruvian ores and annual capacity is rated at 330,000 metric tons of cast
                                                                                                     copper products.
                                                                                                     The smelter furnace temperature control is critical in the plant process and directly related to
                                                                                                     the throughput. With the implementation of advanced control of this parameter, it was
                                                                                                     possible to perform corrections of the ISA furnace's operation in real time and with only one
                                                                                                     controller.




                                                                                Page 76 of 91                                                                                     (Rev. 051010)
                                                                    2010 Emerson Global Users Exchange
                                                                               Workshops


                               Session
                       Track                                         Title                                                                          Abstract
                                  ID
Process Optimization             240     Advanced Process Control Strategy with MPC applied to the      Minera Los Pelambres is one of the top ten copper mines in the World and the fourth in
                                         Crashing Process in the Copper Extraction                      Chile. Its reserves are around 2.2M of copper tones and its production is 339 T/year.
                                                                                                        In this application, it is described the migration from a separate existing expert system to
                                                                                                        one integrated with the plant's control system DeltaV adding APC modules. This involved
                                                                                                        two stages: the first one with traditional PID modules and the second one with MPC for
                                                                                                        regulatory control of the SAG mill and the ball mills.

Process Optimization             288     Interesting and Useful Features of the DeltaV PID, Ratio and   This presentation will explain features of the DeltaV control function block including variable
                                         Bias/Gain Control Block                                        tuning, error squared PID algorithm, two degrees of freedom PID form and structure, gain
                                                                                                        scheduling, dynamic reset limit, output signal characterization and anti-reset windup
                                                                                                        settings. In addition, the use and settings of the Ratio and Bias/Gain function blocks with
                                                                                                        the PID algorithm will be explained.
Process Optimization             341     Using PredictPro’s Optimizer to Maximize Profit from a Real-   PredictPro has been used extensively in various industries to solve difficult control
                                         Time Electrical Purchase Agreement                             problems. In this paper, we show how PredictPro's Optimizer was used to solve a difficult
                                                                                                        optimization problem. Used as the core of an Energy Management System in a multi-
                                                                                                        boiler Co-Generation Plant, the PredictPro Optimizer uses real-time economic and process
                                                                                                        information to manage steam generation and turbine loading to maximize the profit available
                                                                                                        from exporting electrical power. We show how to programmatically manipulate the
                                                                                                        Optimizer's parameters to respond to real-time changes in economic objectives.

Process Optimization             437     Model Predictive Control for Integrating Processes             Model-Predictive Control (MPC) is synonymous with advanced process control (APC).
                                                                                                        DeltaV Predict and PredictPro have been used successfully for many APC projects. But the
                                                                                                        applications tend to involve self-regulating processes. Another family of processes are
                                                                                                        integrating processes, typified by level control. MPC can be applied to integrating
                                                                                                        processes, but there are special considerations. This presentation looks at the special
                                                                                                        issues for using MPC to control integrating processes. A real worldapplication involving
                                                                                                        hoppers and conveyors is used as an example.
Process Optimization             457     Model Predictive Control: Not Just for Large Systems           A Model Predictive Controller with one control variable and one manipulated variable was
                                                                                                        implemented at Ascend Performance Materials using DeltaV's MPCPro block. This
                                                                                                        controller allowed Ascend to significantly reduce the variability of a critical control parameter
                                                                                                        of a reactor product stream, making it possible to operate closer to process constraints, and
                                                                                                        saving almost 7% of the energy required to feed reactants to the unit.
Process Optimization             495     Food Plant Waste Stream Turned to Profit                       A major North American potato product producer has found a way to generate profit from its
                                                                                                        waste stream, and Emerson products and services are helping. The processes used to
                                                                                                        make french fries and other products from raw potatoes generate a waste stream of peels,
                                                                                                        cuttings, and waste water containing starch. This waste is now collected in covered
                                                                                                        anaerobic lagoons at the plants, from which biogas is collected. This biogas is used as a
                                                                                                        low cost fuel source for the power boilers at these sites and Emerson control products and
                                                                                                        solutions are optimizing the use of this waste fuel.
Process Optimization             506     Increase Plant Profits and Savings through Optimum             Process controls can significantly decrease process variability increasing savings and
                                         Process Controls                                               profits. Topics include typical process controls oversights, control performance improving
                                                                                                        tips, control valve impact, instrumentation issues, comprehensive plant tuning. Examples
                                                                                                        include a chemical plant boiler house; pH control in a pharmaceutical thermal-oxidation; a
                                                                                                        pulp and paper plant; pipeline control
Process Optimization             528     Extending the Power of InSight Beyond DeltaV                   DeltaV InSight has proven to be a valuable tool to monitor control performance within the
                                                                                                        DeltaV system. This paper discusses how the application of InSight was extended beyond
                                                                                                        a DeltaV system to include loops in a legacy Honeywell DCS. We will share specific
                                                                                                        application details on how DeltaV InSight was configured and incorporated into existing
                                                                                                        maintenance practices, demonstrating how DeltaV InSight can be used with virtually any
                                                                                                        DCS that supports open communication protocols.




                                                                                Page 77 of 91                                                                                         (Rev. 051010)
                                                                               2010 Emerson Global Users Exchange
                                                                                          Workshops


                                           Session
                       Track                                                    Title                                                                        Abstract
                                              ID
Process Optimization                         562     Hydrocracker Temperature Optimization Fieldbus Project       This paper is a review Valero McKee Refinery Hydrocracker Unit (HCU) Temperature
                                                     Implementation                                               Profile upgrade.

                                                                                                                     Poor temperature measurement makes it possible to have the reaction initiate in localized
                                                                                                                  sections of the catalyst bed. Even during normal operation, the process can develop uneven
                                                                                                                  flow through the catalyst bed that can produce undetected hot spots reduce yields and lead
                                                                                                                  to early catalyst replacement or have more severe consequences affecting the HCU. Using
                                                                                                                  RMT's 848T multipoint temperature transmitter, solved additional for point solution with
                                                                                                                  significant cost savings.
Project Management and Engineering Tools     29      Optimization of Instrumentation and Process Control System   Instrumentation and control system pre-commissioning is the last piece of puzzle to be fit in
                                                     Pre-commissioning                                            place before declaring that a particular process unit of a new project is ready for system
                                                                                                                  commissioning. Float in project schedule is often consumed by other major disciplines like
                                                                                                                  piping and electrical which lead to extreme force in shortening the time allocated for
                                                                                                                  instrumentation and control system construction and pre-commissioning. Based on that
                                                                                                                  strong pre-commissioning execution plan shall be created at very early stage of the project.

Project Management and Engineering Tools     58      Reducing the Engineering Cost                                In principle, engineering has not changed that much over the years. New and more complex
                                                                                                                  technologies have been introduced on the process side and also the control system side.
                                                                                                                    Still, many similar tasks, such as specifications, wiring, and layout, must be performed.
                                                                                                                  From the business viewpoint, the pressure grows to reduce the cost to engineer and build
                                                                                                                  as well as to reduce the time to market in this competitive environment.




Project Management and Engineering Tools     88      A Case Study showing The Good, The Bad and The Ugly of       Why should you select an Automation vendor before you start Front End Engineering
                                                     selecting your vendor before FEED                            Design ?

                                                                                                                    The process, benefits and things to watch for in selecting early will be explored using a real
                                                                                                                  life BP case study.
Project Management and Engineering Tools     91      CCTV: Not just for cops and robbers                          CCTV is traditionally thought of as a security tool for remotely monitoring of an area to
                                                                                                                  insure that only authorized personnel are in and about that area, but in the process industry
                                                                                                                  CCTV can perform a larger role than that of a watchdog tool. It can provide operations with a
                                                                                                                  remote view of the process area and equipment. It can also provide a safe way of
                                                                                                                  evaluating the unit in an upset situation allowing operations to examine outside conditions
                                                                                                                  before ventuuring into them.
Project Management and Engineering Tools     111     Make the Most of Lessons Learned - Tools and Techniques      Capturing lessons learned can be a difficult and neglected aspect of project management.
                                                                                                                  But, if done properly, the benefits for future projects can be significant.

                                                                                                                  Every project provides new opportunities and challenges. How these situations are planned
                                                                                                                  for, recognized and responded to, along with their project impacts (positive and negative)
                                                                                                                  are lessons that can be captured for future projects. This workshop will discuss effective
                                                                                                                  techniques and methods for capturing, documenting, storing and retrieving lessons learned
                                                                                                                  for the benefit of future similar projects.
Project Management and Engineering Tools     149     Streamlined DeltaV Change and Testing Method                 Our previous method of making and testing changes to our DeltaV systems, was very labor
                                                                                                                  and material intensive. This method has been replaced with a partial electronic method for
                                                                                                                  changes and standard test scripts for testing.




                                                                                           Page 78 of 91                                                                                       (Rev. 051010)
                                                                                2010 Emerson Global Users Exchange
                                                                                           Workshops


                                           Session
                   Track                                                         Title                                                                       Abstract
                                              ID
Project Management and Engineering Tools     158     Best Practices for a Smooth Engineering and Successful        The presenter will share Best Practices experiencesof engineering a fieldbus project, how
                                                     Startup of Foundation Fieldbus Projects                       best to make use of the Fieldbus technology and its products, importance of training during
                                                                                                                   project phases, educating thefield installation contractor to do correctly the segment
                                                                                                                   checkout work. He will explain how engineering work such as AMSset up,preliminary Alerts
                                                                                                                   set up, Valve link software set up help to achieve smooth plant start up with examples from
                                                                                                                   successfully commissionedprojects such asATCII and PDH in Thailand, QG2 project and
                                                                                                                   Fujian Refining and Ethylene in China
Project Management and Engineering Tools     185     So why would an EPC want to ever use CHARMS?                  We've heard the marketing spin, but what would DeltaV v11 and Electronic Marshalling
                                                                                                                   mean to a real project? A team from Emerson and Fluor have examined the impact that
                                                                                                                   DeltaV v11 would have made to a recent project.The teamwill present their conclusions
                                                                                                                   which included cost savings, reduction of the impact of late changes, and a robust single-
                                                                                                                   pass project executionmethodology. If you want to understand what CHARMs might mean
                                                                                                                   for you and your project then this workshop will give you some real-life insights.

Project Management and Engineering Tools     262     Selecting the right Foundation Fieldbus device –              When selecting FF devices which are not manufactured by the HOST vendor, the best
                                                     Interoperability or Integration?                              choice is to use devices and components which are registered with the Fieldbus
                                                                                                                   Foundation. This will ensure a basic "interoperability" which ensures that the device
                                                                                                                   communicates with the HOST system and other devices per the FF Specifications. It does
                                                                                                                   not mean that it will perform as advertized or expected. Will it work as expected? What
                                                                                                                   features are available, which are needed? Are the displays and interfaces easy to see and
                                                                                                                   use? What are the quirks and "gotchas"?
Project Management and Engineering Tools     267     Proven Process, Streamlined Startup: Lucite International’s   Lucite International's Singapore facility, a large chemical complex, required thousands of
                                                     Smart Commissioning Project                                   hours of manual labor for proper quality control inspections and documentation during
                                                                                                                   construction and commissioning of instrumentation and electrical components. Emerson's
                                                                                                                   Smart Commissioning Services were employed to help facilitate the process, saving the
                                                                                                                   plant $335,000 in typical costs.
Project Management and Engineering Tools     335     Control systems project execution - an unconventional
                                                     approach                                                       EPC is a mature industry and the project execution work processes we follow are more or
                                                                                                                   less mature. Following this conventional approach to execute a project allows us to go
                                                                                                                   through the engineering phase somewhat placidly, but many a times it disallows us from
                                                                                                                   optimizing for improvement. We all know the issues that are troublesome and we all know
                                                                                                                   that these issues repeat themselves project after project. This presentation brings out some
                                                                                                                   ideas that do not conform to the orthodox way of executing the engineering phase of a
                                                                                                                   project.
Project Management and Engineering Tools     348     Evolving Organizational Structures of Large Design Teams      Managing large design teams in today's business environment requires team adaptability to
                                                                                                                   meet the needs of changing project requirements. Changing conditions pose continuing
                                                                                                                   challenges to team effectiveness and efficiency. The organizational structure of these
                                                                                                                   teams must evolve and adapt throughout the life of a project to overcome these challenges.
                                                                                                                    Presentation includes obstacles to managing a large design team through the phases of a
                                                                                                                   project and presents an evolutionary timeline of a typical project team. It provides a
                                                                                                                   template for a large design team over the life of a project.

Project Management and Engineering Tools     374     Harnessing Your Experts’ Knowledge for Sustainable            More than ever, companies realize their competitive advantage comes from what they know.
                                                     Competitive Advantage                                          By flexing their intellectual muscle, businesses become more efficient, avoid repeating
                                                                                                                   mistakes, and encourage innovation. Expertise exists in your company, so how can your
                                                                                                                   learners apply what your experts already know? And how can you pass along practical know-
                                                                                                                   how from your experts before they leave or retire? In this workshop, we will discuss some
                                                                                                                   barriers to sharing knowledge, and we will discuss practical tools and approaches to
                                                                                                                   cultivate sharing within your organization.




                                                                                            Page 79 of 91                                                                                     (Rev. 051010)
                                                                                2010 Emerson Global Users Exchange
                                                                                           Workshops


                                           Session
                    Track                                                        Title                                                                       Abstract
                                              ID
Project Management and Engineering Tools     412     AS-I Integrating Low-Cost Discretes Using a Low-Cost          Actuator Sensor Interface, or AS-Interface or AS-I Bus, is an open data exchange industrial
                                                     Method                                                        communication network between discrete input/output devices and automation controllers. It
                                                                                                                   is a highly distributed network for standard discrete I/O; it is a solution supported by 300
                                                                                                                   vendors; and it is the only network with connections to all major PLC suppliers. This paper
                                                                                                                   will describe the use of low cost AS-I products (Masters, Infrastructure, and Slaves) to
                                                                                                                   interface low cost discrete I/O.
Project Management and Engineering Tools     421     System Integrators Scope of Work                              Whether you work for EPC Firm or an owner's organization most scope disagreements
                                                                                                                   occur when one party assumes that the other party will perform a specific scope of work.
                                                                                                                   Sometimes we assume a project will be executed similar to another or we don't know what
                                                                                                                   scope is who's scope and assume. This workshop is intended to outline a typical system
                                                                                                                   integrator scope of work.
Project Management and Engineering Tools     488     Leveraging existing code - A boon or a burden?                As the DeltaVindustry matures, there is a growing welath of existing automation code that
                                                                                                                   may beused for new captial projects. Leveraging existing code appropriatelywill reduce
                                                                                                                   captial cost and shrink development time.However, leveraging the code in an inappropriate
                                                                                                                   way can lead to missed deadlines and unexpected expenses. This workshop will review and
                                                                                                                   contrastthe DeltaV code leveragedforthree (3) capital projects in the pharmaceutical industry.

Project Management and Engineering Tools     544     How Range Fuels Partnered With Emerson and Benefitted     Building a new biofuels conversion plant can be risky business. Decisions regarding the
                                                     From the Main Automation Contractor Approach to Project   process technology, feedstock availability, plant location, process equipment fabricators,
                                                     Execution                                                 etc. are only part of the equation. What about the automation system? This presentation will
                                                                                                               cover how Range Fuels partnered with Emerson and benefitted from the Main Automation
                                                                                                               Contractor approach to executing the project.
Project Management and Engineering Tools     551     Conducting a Full Field Simulation Project in the US Mid- Norwest, a consulting firm to the energy, mining, and natural resources sectors, has
                                                     Continent to Improve Field Recovery                       extensive experience in Coalbed Methane (CBM), a form of natural gas extracted from coal
                                                                                                               beds. This abstract examines how Norwest used the Roxar Tempest MORE reservoir
                                                                                                               simulator for a full field simulation project in the U.S mid-continent. The resulting simulation
                                                                                                               model was used to optimize the timing and sequence of infill drilling, as well as the
                                                                                                               conversion of existing wells to air injection. Current estimates based on the simulation
                                                                                                               model indicate field recovery will more than double .
Project Management and Engineering Tools     558     SBM Offshore Reduces Risk and Costs Through Partnership SBM Offshore is a pioneer in the offshore oil and gas industry. The partnership with
                                                                                                               Emerson has reduced risk and costs on 2 FPSO projects deployed from SBM's Monaco
                                                                                                               office. SBM named Emerson the instrumentation, control valves and regulators supplier on
                                                                                                               the projects. An integrated team of SBM and Emerson people were located in Monaco,
                                                                                                               including a project manager.
Safety Instrumented Systems                  64      “SIS Final Element Diagnostics Including The SOV, Using A Traditionally Safety instrumented Systems are functionally tested during turnarounds on
                                                     Digital Valve Controller”                                 yearly or once in two year basis. Present economies and pressure to maximize production
                                                                                                               are forcing process industries to extend shutdown period to 3 or in some cases to 5 years.
                                                                                                               This puts onus on Final control element, including SOV, which remains untested for longer
                                                                                                               time.
Safety Instrumented Systems                  92      What Now? More Standards for Safety and Regulatory        Just when a majority of industrial manufacturers were getting the hang of the global safety
                                                     Compliance                                                requirements, professional societies are developing even more guidance documents for
                                                                                                               Burner Management System (BMS) applications. Industry experts suggest these
                                                                                                               "clarifications" are necessary as NFPA 85 dictates BMS design and operation from a
                                                                                                               prescriptive viewpoint. ANSI/ISA TR 5 provides guidance on expected performance and API
                                                                                                               556 from an experience point of view. However, many end-users fear it will become a hard
                                                                                                               line compliance issue with OSHA and Local Jurisdictional Authorities.




                                                                                            Page 80 of 91                                                                                     (Rev. 051010)
                                                                   2010 Emerson Global Users Exchange
                                                                              Workshops


                              Session
                    Track                                           Title                                                                        Abstract
                                 ID
Safety Instrumented Systems      93     How to Avoid Shooting Yourself in the Foot with Your SIS?  The use of three transmitters (two SIS and one BPCS)is utilized for the generation of
                                        You can minimize the risk of creating a safety demand (SIS deviation alarming. This alarming is set up so that if the BPCS data becomes widely
                                                                                                   different from the SIS transmitters, the controller(s) will be placed into MANUAL, and
                                        or PSV) from BPCS single loop failures with the use of well-
                                        designed instrumentation, deviation alarming and backup    alarmed. The operator will then have the opportunity to select which SIS transmitter data
                                        PID loop control.                                          value on which to control until the BPCS transmitter can be repaired.
Safety Instrumented Systems     107     DeltaV SIS in the Heat Of The Desert                       There are a number of new technologies available to Oil Producers but ensuring we gain
                                                                                                   tangible benefits require correct evaluation and selection. A Major Oil producer in the Middle
                                                                                                   East identified a number of new technologies and choose to evaluate these, to ensure
                                                                                                   operational benefits and capital savings could be achieved. The major oil producer saw
                                                                                                   future benefits in DeltaV SIS, Intelligent valve positioners and wireless technologies. This
                                                                                                   presentation will present the technology evaluation and the benefits that the Major Oil
                                                                                                   Producer believes it can achieve.
Safety Instrumented Systems     174     On-line SIS testing Using AMS                              Traditional methods for on-line testing of field transmitters for safety systems make little use
                                                                                                   of the capabilities of modern smart transmitters and also require considerable coordination
                                                                                                   with operations. As more Safety Instrumented Systems are implemented in the refinery the
                                                                                                   increase in demand to perform the labor intensive traditional methods presents challenges
                                                                                                   on managing the qualified resources. Now with AMS, much of the labor has been removed
                                                                                                   from the testing and the automated documentation makes it easy to better understand
                                                                                                   failure modes and frequency to further improve safety.
Safety Instrumented Systems     184     Burner Management – A straightforward approach using       If you are considering a new Burner Management System, there are many reasons a DeltaV
                                        DeltaV SIS for typical systems.                            SIS should be explored. The DeltaV SIS system has many advantages including scalability,
                                                                                                   utilization of smart instruments, integrated Control and BMS Systems, and embedded safety
                                                                                                   functions.
                                                                                                     Like many other vendors, DeltaV SIS can handle simple standard logic diagrams; however,
                                                                                                   advanced function blocks allow your application to utilize an advanced state-based
                                                                                                   engineering approach. This approach helps to simplify the design, configuration and testing -
                                                                                                    resulting in time savings and reduced complexity.
Safety Instrumented Systems     193     Embracing new technology. ..Replacing Triconex with DeltaV A major producer of nitrogen products needed to replace an aging TMR Triconex safety trip
                                        SIS.                                                       system. By evaluating new technologies, the process manufacturer realized the benefits that
                                                                                                   DeltaV SIS can offer; however, since the entire plant complex is dependent on the trip
                                                                                                   system that needed replacement, this project was critical to keep the plant running. This
                                                                                                   high profile upgrade project was successfully completed by using smart device diagnostics,
                                                                                                   leveraging the integrated BPCS and SIS architecture, and relying on Emerson's safety-
                                                                                                   certified engineering services.
Safety Instrumented Systems     203     RockTenn’s BMS Project Uses DeltaV SIS                     Replacing an aged BMS system for boilers? Should you implement an SIS? RockTenn
                                                                                                   needed to replace an aged and unreliable BMS system for their boilers. To comply with
                                                                                                   industry standards and take advantage of diagnostic information, RockTenn successfully
                                                                                                   completed this project using the DeltaV SIS process safety system and integrating it with the
                                                                                                   existing DeltaV and AMS systems. Emerson provided local safety expertise and engineering
                                                                                                   services to help ensure that compliance requirements were meet.

Safety Instrumented Systems     234     F&G solutions with DeltaV SIS                                  Since the release of DeltaV SIS Emerson has been steadily increasing its abilities to provide
                                                                                                       a F&G solution as it is required by the industry. Through recent developments Emerson is
                                                                                                       now even more capable of providing a full DeltaV SIS based F&G solution. This workshop
                                                                                                       will touch on the improvements made. These improvements vary from new possibilities for
                                                                                                       applying DeltaV SIS to F&G applications, as well as improved libraries for F&G HMI.




                                                                               Page 81 of 91                                                                                      (Rev. 051010)
                                                                    2010 Emerson Global Users Exchange
                                                                               Workshops


                              Session
                     Track                                           Title                                                                      Abstract
                                 ID
Safety Instrumented Systems     257     Build on your Safety Instrument System knowledge to           When designing safety instrument systems, failure modes initiated by the application itself
                                        achieve best practice for application safety aspects in       need special consideration. For level measurements this is particularly important due to high
                                        IEC61511 level safety                                         application dependency. This session will address different types of application initiated
                                                                                                      failure modes, how these can be avoided by careful selection of instrument options utilizing
                                                                                                      simple best practices, and how automatic diagnostics features can reduce the number of
                                                                                                      undetected dangerous failures.
Safety Instrumented Systems     315     Usign Syncade Workflow and AMS Device Manager for SIF         Work process and documentation requirements for IEC 61511 compliant safety systems
                                        Proof Testing on a DeltaV SMART SIS System                    require more diligence than what normally occurs during checkout of a BPCS system. In
                                                                                                      order to establish a set workflow that guides the tester through the steps, Syncade in
                                                                                                      conjunction with DeltaV SIS, AMS and the QuickCheck Snap-On provides an architecture
                                                                                                      that guides the tester through a defined workflow, documenting each step.

Safety Instrumented Systems     316     Safety Requirements Specifications - Guidelines and           Development of Safety Requirements Specifications (SRS) is an essential and extremely
                                        Common Mistakes                                               critical step in the safety lifecycle that presents challenges in how to convey sufficient
                                                                                                      information to the team that is designing, constructing, commissioning, and installing the
                                                                                                      specified safety systems. The fundamental problem is not following good specification
                                                                                                      practices and considering how the SRS documentation will be used, once created, resulting
                                                                                                      in poorly prepared specifications. This presentation presents best practices for preparing a
                                                                                                      SRS with a specific emphasis on DeltaV SIS based systems.
Safety Instrumented Systems     489     Data Integration Between BPCS and SIS Offer Significant       Compliance best practices based on ISA 84/IEC 61511 requires process manufacturers to
                                        Engineering Savings at Novus                                  evaluate the need for safety systems in all areas of the plant. Novus addressed the
                                                                                                      challenge of replacing an aged panel-based waste stream interlock system by implementing
                                                                                                      an SIS. Using an integrated control and safety system (ICSS), Novus was able to comply
                                                                                                      with regulations, reduce engineering effort, provide fast troubleshooting, and allow easy
                                                                                                      access to safety information at the operator interface.

Safety Instrumented Systems     499     Hydraulic Partical Stroke and Diagnostics - Improve Safety    High Pressure hydraulic partial stroke and diagnostics systems, offer significant
                                        and Reliability of your High Pressure System using HPSD       opportunities to collect and analyze the data on remote valves and actuators, thereby
                                                                                                      improving reliability and safety of the system while meeting the requirements of SIS.
                                                                                                      Intelligent diagnostic devices in the low pressure pneumatic segments such as the DVC
                                                                                                      meet these market needs. Emerson Process Management, Valve Automation introduces a
                                                                                                      new product in the high pressure hydraulic segment meeting the industry requirements for a
                                                                                                      High Pressure Partial Stroke and Diagnostic (HPSD) system.
Valve Applications              38      Valve Testing Standards Result in Higher Performance          International Paper's IEPM standards help IP recognize Fisher's superior products and
                                                                                                      services through stringent testing and proven performance. Their stringent guidelines
                                                                                                      improve mill performance and reduce downtime.
Valve Applications              49      How and what instruments to size for valve performance        When valve performance requirements typically include stroking speeds. But how do you
                                                                                                      get from those requirements to the proper instruments needed. You know a positioner is
                                                                                                      involved but is that enough. In many cases that is not enough, volume booster are used in
                                                                                                      conjunction with a positioner on a throttling control valve to increase stroking speed. These
                                                                                                      boosters deliver high-volume output for fast stroking when large, rapid input signal changes
                                                                                                      occur. But there is more, when a filter regulator is used they also must accounted for.

Valve Applications              56      Unique application, control valve solutions, and system       Thisworkshop will explain the unique requirementsof theresidual heat removal application in
                                        testing requirments for the residual hear removal system in   a Westinghouse AP1000 nuclear plant, whichis one of the most critical control valves
                                        the Westinghouse AP1000 next generation Nuclear plant.        applications in passive safety system. The custom control valve solutionwasdesigned
                                                                                                      specifically for this application by the Fisher Division of Emerson Process Management.The
                                                                                                      results ofa full scale system test that was done in the Emerson Innovation Center for Fisher
                                                                                                      Technology will be presented.




                                                                                Page 82 of 91                                                                                    (Rev. 051010)
                                                                 2010 Emerson Global Users Exchange
                                                                            Workshops


                             Session
                     Track                                        Title                                                                        Abstract
                                ID
Valve Applications             116     How Flow Lab Capabilities Bring Better Understanding Of      Flow labs can offer real life testing situations which enhance the understanding and
                                       Series Component Interaction That Results In Better          modeling for control valve applications. One such example of this capability is backpressure
                                       Modeling Techniques To Quiet Real Life Applications.         devices and series restriction interactions. Flow lab test results confirmed the sizing model,
                                                                                                    which helped to resolve an existing, multiple component installation that was operating at
                                                                                                    unacceptable noise levels at a steam heating pressure reducing station. The sizing
                                                                                                    calculations allowed for proper final control element selection to reduce the overall noise to
                                                                                                    acceptable levels.
Valve Applications             153     Successful Refinery Noise Reduction - ISOMAX Quench          For many years, there has been a high magnitude tone generated in the ISOMAX area of
                                       Valves                                                       the Chevron El Segundo Refinery near the non-Fisher quench valves for two of the reactors.
                                                                                                    It has increased over time, eventually causing local neighbors to give noise complaints. A
                                                                                                    Fisher Controls test engineer performed a noise and vibration survey in July 2009. It
                                                                                                    determined that the main noise source were the stems of the quench valves. Caltrol
                                                                                                    developed a solution to replace the quench valves with Fisher 4x3 Inch Type HPT-657-
                                                                                                    DVC6000. Since installed, all tones have been eliminated.
Valve Applications             170     Fisher Control Disk™ Valve Solves Temperature Control        Shell Todd Oil Services gas plant in New Zealand had experienced a change in
                                       Issue in Fractionation Column                                production rate through their fractionation unit that separates methane and Liquefied
                                                                                                    Petroleum Gas (LPG). The butterfly valve that was in service could not adequately control
                                                                                                    the temperature at the new set point resulting in poor product quality and decreased
                                                                                                    revenues. The Fisher Control Disk Valve replaced the existing butterfly valve in 2006
                                                                                                    improving control and resulting in increased purity of the natural gas output stream. The
                                                                                                    Control Disk Valve is still installed and performing great.
Valve Applications             177     FIELDVUE DVC’s Help Increase Efficiency and Uptime for       Praxair owns and operates hundreds of cryogenic air separation plants globally, many of
                                       Air Separation Plants                                        which use old operating methods that reduce the potential efficiency and uptime of the plant.
                                                                                                    Through their R&D department Praxair has come up with various solutions to increase the
                                                                                                    efficiency and uptime of these plants utilizing new technology, the most promising of which
                                                                                                    is utilizing FIELDVUE DVC's to slowly open their feed valves into their temperature swing
                                                                                                    adsorption units.
Valve Applications             222     What is better? HART communications? Or a thousand feet      For getting the stem position, the traditional solution was to mount an independent position
                                       of wire?                                                     transmitter onto your valve assembly and run thousands of feet of signal wire into the field to
                                                                                                    connect it to your AI channel on your DCS. It is common knowledge that thisis faster than
                                                                                                    feedback via HART messaging. Or is it? This workshop will explore your options.

Valve Applications             239     Control & Maintenance Optimization Process - Petrobras
                                       Refinery REPLAN – Maintenance Contracts                        Petrobras REPLAN, one of Petrobras Business Units, has a maintenance contract for
                                                                                                    control valves with Emerson Process Management. This also allowed the improvement of
                                                                                                    various processes, especially in the last year on the IGV-22650 (FCC air blower capacity
                                                                                                    control), using 2 DVC's redundant controler this process.
Valve Applications             273     Salvaging a Start-Up: Recovery and Repair Save the Day for   When the discovery that hydrogen sulfide had eroded the internal surface of a severe
                                       Chevron                                                      service valve beyond repair, start up after a planned maintenance turnaround was in
                                                                                                    jeopardy of being delayed at the Chevron, El Segundo, plant. Typical repair and
                                                                                                    replacement options meant further delay, costing the plant lost revenue. This paper will
                                                                                                    demonstrate how Emerson was able to salvage another valve and leverage supplier
                                                                                                    relationships to provide a same-day solution which allowed the plant to start up on time.
Valve Applications             279     Online Overhaul: Technicians Take on Technology to           A corporate initiative to improve reliability through predictive maintenance practices has
                                       Provide Instant Access to BP Automation Upgrades             prompted the BP refinery in Texas City to implement an automation upgrade program.
                                                                                                    Systematically replacing analog devices with digital valve controllers while the plant is online
                                                                                                    allows maximum use of diagnostic capabilities with minimal downtime. This paper will
                                                                                                    demonstrate how Emerson was able to build on the knowledge of hot cutover methods to
                                                                                                    allow for device installation and instant diagnostic access for critical control valves while
                                                                                                    online, despite the lack of a bypass system.




                                                                             Page 83 of 91                                                                                       (Rev. 051010)
                                                                    2010 Emerson Global Users Exchange
                                                                               Workshops


                             Session
                     Track                                           Title                                                                       Abstract
                                ID
Valve Applications             389     40 Years Later and Valero Benicia is still utilizing Fisher's   There is nothing more concerning to a refinery than trying to replace a valve design that has
                                       7600 Buttefly Valve                                             lasted more than 40 years in service and now is obsolete. As the need for more efficient
                                                                                                       and cost effective processes increases, so does the complexity of the applications that
                                                                                                       process control equipment is exposed to. Customers are continually driving for longer
                                                                                                       lasting equipment that can withstand the harshest of environments and still maintain
                                                                                                       performance reliability; Fisher is dedicated to helping customers with this goal.

Valve Applications             462     Suncor’s use of Fisher Furnace Feed design in Coker             Suncor Energy Inc. is using the Fisher Furnace Feed design on the Cokers for the Voyageur
                                       Charge service in the Oilsands.                                 project. Working together Fisher, Spartan, IV&S and Suncor have evolved the design over
                                                                                                       several generations to provide a robust, reliable and cost effective solution to a challenging
                                                                                                       application.
Valve Applications             469     Control-Disk valves make worlds largest CFB Power Plant         FisherControls provided Qty 36 Control-Disk valves to JEA's 300-MegaWatt Northside
                                       more efficient!                                                 Generating Station Units 1&2. This is the world's largest circulating fluidized bed (CFB)
                                                                                                       boiler in the world. This power plant produces electricity by burning coal and petroleum
                                                                                                       coke. The Control Disk valves are installed just upstream of the fluidizing air nozzles in the
                                                                                                       bottom of the combustor. That air expands the bed, creates turbulence for enhanced mixing
                                                                                                       and provides most of the oxygen necessary for combustion of the fuel. Improved flow to the
                                                                                                       nozzles improves combustion and efficiency for the plant.

Valve Applications             473     Application Expertise Results in Big Savings              For years, Koch Nitrogen's facility in Enid , OK has experienced issues with their critical
                                                                                                 Benfield solution control valves. These issues resulted in high annual maintenance costs,
                                                                                                 increased downtime, and reduced performance and efficiency. Combined with
                                                                                                 Fisher'sapplication expertisein highvibration and severeflashing erosion, an engineered
                                                                                                 valve solution was developed resulting in lower annual maintenance costs, reduced
                                                                                                 downtime, and better performance.
Valve Applications             485     Engineered Dirty Service Valve Solution Benefits Aera     Water injection service is one of the most severe valve applications associated with the oil
                                       Energy                                                    production process. Whether the customer intends to dispose of their unwanted produced
                                                                                                 water or enhance production via waterflood, this application requires careful valve selection
                                                                                                 to ensure the installed product can handle the severity of the service. Produced water
                                                                                                 contains abrasive residual components and is subject to extreme pressure drops associated
                                                                                                 with the injection process. Emerson provided Aera Energy a successful Fisher valve
                                                                                                 solution to handle these difficult conditions.
Valve Applications             530     Severe Service Valve trim enhancement solves maintenance One of the top oilsands producers in Alberta Canada's Athabasca region expressed a desire
                                       headache, extends shutdown interval                       to achieve improved shutoff performance from the control valves installed in the steam
                                                                                                 generator blowdown application. This particular application has traditionally been very
                                                                                                 difficult due to the various process conditions that the valve must undergo; cold cavitating
                                                                                                 water, hot flashing water, and eventually 80% quality steam. Aside from the obvious
                                                                                                 process hurdles, mis-specification of the required shutoff class is common which can lead to
                                                                                                 further trim integrity concerns after initial startup.
Valve Applications             549     Optimizing Plant Performance Using Predictive Diagnostics Traditional control systems have been used in process control and manual labor has been
                                       via Digital Valve Controller Mounted on Control Valve     used for maintaining field devices. Traditional control systems do not provide a systematic
                                                                                                 way to monitor, diagnose and improve performance of field devices. Pneumatic or electro-
                                                                                                 pneumatic devices do not have intelligence. Advances in control instr systems have brought
                                                                                                 new dimensions to provide optimum plant performance by using intelligence from field
                                                                                                 devices. Challenges still remain on use of appropriate field devices. Field devices like
                                                                                                 sensors/FCE are important for precise control/higher plant efficiency but FCE is most critical.

Valve Applications             557     Control Valves and Regulators for the Pharmaceutical            Genzyme chooses Emerson for its new biomanufacturing plant in Lyon, France, for the
                                       Industry                                                        production of of Thymoglobulin (Anti-thymocyte Globulin [Rabbit]), a product to treat acute
                                                                                                       rejection in transplant patients.




                                                                                 Page 84 of 91                                                                                     (Rev. 051010)
                                                                      2010 Emerson Global Users Exchange
                                                                                 Workshops


                                Session
                        Track                                          Title                                                                        Abstract
                                   ID
Wireless Applications              36     Improving production with wireless temperature monitoring     We are helping the operation of their iron ore pelletizing furnace in Vitoria, Brazil, one of the
                                                                                                        largest in the world, thanks to the fact that Smart Wireless makes it possible to monitor
                                                                                                        process variables on a moving equipment, something that was not possible before with
                                                                                                        conventional wired approach. This is a small application, but it is extremely strategic to their
                                                                                                        production because the furnace is the heart of their operation.

Wireless Applications             59      Lixiviation Performance Monitoring with Smart Wireless        Barrick, the biggest gold producer in the World is the owner of the Zaldivar Plant in Chile, an
                                          Technology at Barrick Zaldivar                                open-pit, heap-leach copper mine in the north of the country that produces 150K tonnes of
                                                                                                        pure cathode copper a year. The copper extraction process at that mine is lixiviation (leach
                                                                                                        pads). The product irrigated and distributed in the pad (sulphuric acid) is a critical variable
                                                                                                        that impacts the whole process. In this workshop it will be presented how the Smart
                                                                                                        Wireless technology allowed improving the plant's throughput giving Barrick the necessary
                                                                                                        tools to optimize the process.
Wireless Applications             65      The Right Bus for the Right Application: To Be or Not to Be   An Acid plant with a capacity of 300 tons/day is under construction in the Third Region of
                                          WirelessHART in a Sulphuric Acid Production Plant             Chile. The objective of the plant is to provide the necessary amount of Acid for the Leaching
                                                                                                        Copper Production Process. This project was developed in response to the shortage and
                                                                                                        high cost of this product, which is necessary for the process. In case of overproduction, Acid
                                                                                                        could be sold to third parties.
                                                                                                        As part of the construction, it was necessary to include instrumentation with easy installation
                                                                                                        and a low total cost of implementation.
Wireless Applications             78      Flexible and clean design with wireless installation          Abstract;     A bioethanol pilot plant was designed and built 2009 in order to develop in-
                                                                                                        house process technology at Chematur. This was realized utilizing state of the art
                                                                                                        automation equipment, such as Foundation Fieldbus and Wireless HART instruments. This
                                                                                                        in order to evaluate new technology for possible future large-scale implementations, as well
                                                                                                        as to show potential customers and clients how a thought-through PlantWeb-concept can
                                                                                                        give benefits to operation and production.

Wireless Applications             87      Installation Cost Savings with Smart Wireless Technology in   This is a Smart Wireless application for oil temperature and flow measurement at Petrolera
                                          an O&G Field? Prove It!                                       Entre Lomas field in Argentina. Entre Lomas field produces oil & gas and it is part of the
                                                                                                        Entre Lomas concession, approximately 60 miles north of the city of Neuquen on the
                                                                                                        eastern slopes of the Andes Mountains
Wireless Applications             125     Utilizing AMS softeware to Plan a Wireless Network




                                                                                                         This presentation will detail the work involved in utilizing AMS Wireless Snap-On to plan a
                                                                                                        wireless network at the Conoco Phillip Bayway refinery tank farms.
Wireless Applications             159     Emerson Smart Wireless Solution ensures on-time               This presentation covers a wireless installation at the Atlas Natural Gas Plant (Midkiff)
                                          installation                                                  outside of Midland, Texas. The project was a fully integrated solution of Delta-V and
                                                                                                        wireless seamlessly integrated by Vinson Process Controls out of Midland, Texas. The
                                                                                                        project is an upgrade to an existing "pnuematically controlled" system and then a new
                                                                                                        expansion plant.
Wireless Applications             189     Deploying Wireless in the Process Industries                  Building on the success of the global "Deploying Wireless in the Chemical Industry" webinar
                                                                                                        series, this short course will explore the benefits that wireless technologies bring to a variety
                                                                                                        of users in more detail in a highly interactive session. Learn about the unique capabilities
                                                                                                        that wireless technology can make to production, maintenance, projects, systems and
                                                                                                        executive management. Wireless is not just another protocl, but a technology which has the
                                                                                                        potential to transform the way that you work.




                                                                                   Page 85 of 91                                                                                       (Rev. 051010)
                                                                     2010 Emerson Global Users Exchange
                                                                                Workshops


                                Session
                        Track                                          Title                                                                        Abstract
                                   ID
Wireless Applications             196     Wireless Conductivity and pH Measurements for                  The application of carbon capture to existing power plants requires a significant capital
                                          Optimization of Carbon Capture                                 investment on the order of $1,000,000 per megawatt capacity. The annual energy cost
                                                                                                         associated with carbon capture for a typical power plantis on the order of hundreds of
                                                                                                         millions of dollars per year. This presentation shows how wireless conductivity and pH
                                                                                                         transmitters interfaced to DeltaV were used in extensive lab testing to develop relationships
                                                                                                         for CO 2 and solvent concentration for optimization of solvent concentration to reduce
                                                                                                         initial investment and operating costs.
Wireless Applications             201     THUM’S UP! : Wireless Troubleshooting of Intermittent
                                          Upsets                                                           A major Pulp and Paper manufacturer was experiencing occasional process upsets
                                                                                                         attributed to "questionable" flow measurements. Before techs could inspect the flow meter,
                                                                                                         the upset would reset. Lack of SMART I/O prevented onlinediagnostic monitoringuntil a
                                                                                                         SMART Wireless Network was installed in a nearby process area. A THUM Smart Wireless
                                                                                                         HART Adapter was added to the transmitter in question and continuous monitoring of the
                                                                                                         device diagnostics began. Flow uncertainty was eliminated. Installation of the THUM 20'
                                                                                                         above the transmitterexpanded thewireless network into the new process area.

Wireless Applications             205     Solid Drain Waste System                                       Basically the process works in the following way: Alunorte produces a basic material for
                                                                                                         producing aluminum, called alumina. Every moment big trucks bring to the DRS tons of a
                                                                                                         residue that is results of processing alumina which is very rich in caustic soda and is very
                                                                                                         alkaline also. After that they are disposed in that DRS area. So this material CAN NOT
                                                                                                         LEAK to the environment, if that happens is a tragedy, there are lot of people those depends
                                                                                                         the rivers and the environment there.
Wireless Applications             223     Cost effective means for Wireless Liquid Hydrocarbon Leak      This discussion will cover how wireless technology can cost competitively ensure solutions
                                          Detection                                                      for underground leak detection, rapid surface spill detection, and a means to monitor water
                                                                                                         discharge for oily contaminates. The presentation will cover how this joint technology will
                                                                                                         provide a reliable solution with the application of the WirelessHART technology.

Wireless Applications             225     Smart Wireless Measurement Avoids Shutdowns of a 16MW          Newmont's Minera Yanacocha complex in Peru is the largest gold mine in Latin America
                                          Rotating SAG Mill at Newmont’s Minera Yanacocha complex        and the second largest in the world. In 2009, Newmont decided to start monitoring the
                                                                                                         temperature of the SAG mill's motor, the main critical equipment for the process. This
                                                                                                         application includes a Smart Wireless temperature device rotating with the gold mill and it is
                                                                                                         impossible to implement without this technology. This is an extension of the PlantWeb
                                                                                                         digital architecture that Newmont implemented for the Gold Mill project in 2008.

Wireless Applications             227     Smart Wireless and Ultrasonic Technology Generate $4M         With the implementation of Smart Wireless (including a network's expansion adding 50%
                                          Incremental Sales and Reduce 62% Maintenance Costs at         more devices in one year) and installing Ultrasonic technology and AMS Device Manager,
                                          Tecpetrol                                                     Tecpetrol obtained operational benefits, additional maintenance and supervisory cost
                                                                                                        reductions.
                                                                                                        Tecpetrol is an Argentinean company that has an annual production capacity of 31.7 million
                                                                                                        barrels equivalent and, with operations in Argentina, Ecuador, Venezuela, Bolivia, Peru and
                                                                                                        Mexico, has been growing steadily in Latin America.
Wireless Applications             231     Monitoring Essential Assets – Wirelessly                      Most plants have real-time monitoring of the most critical major equipment like compressors
                                                                                                        and turbines, but in the past, real-time monitoring of second-tier equipment has been cost
                                                                                                        prohibitive. Not so anymore. Emerson is introducing a new suite of cost-effective, wireless
                                                                                                        asset monitoring solutions designed to provide operator asset dashboards with early
                                                                                                        warning of equipment failure.
Wireless Applications             242     Smart Wireless Technology applied to Electrolytic Refining in Codelco is a Chile's state-owned copper mining, the World's top copper producer and with
                                          the M&M Industry                                              the biggest copper proven reserves in the planet. In this application, it will be presented how
                                                                                                        Codelco is applying the Smart Wireless technology to reduce maintenance costs and
                                                                                                        instrument the Ventanas plant in the V Region in Chile.




                                                                                  Page 86 of 91                                                                                      (Rev. 051010)
                                                                    2010 Emerson Global Users Exchange
                                                                               Workshops


                                Session
                        Track                                         Title                                                                       Abstract
                                   ID
Wireless Applications             249     Smart Wireless Technology allows Process Control             Codelco is a Chile's state-owned copper mining, the World's top copper producer and with
                                          Improvement and Maintenance Savings at Treatment Plant       the biggest copper proven reserves in the planet. In this application, it will be presented how
                                          in Copper Production                                         Codelco is applying the Smart Wireless technology to improve control actions and monitor
                                                                                                       process variables in the treatment and gas purge plant at El Teniente plant, located in the VI
                                                                                                       Region of Chile.
Wireless Applications             252     Wireless Steam Injection and Oil Production Monitoring       The Hopkins lease in McKittrick , California produces about 2700 barrels of crude per
                                          Project                                                      day, at the cost of approximately 20,000 barrels of steam per day (7,000,000 lb per day or
                                                                                                       close to $10,000,000 per year). It is estimated that ¾ of the cost of one barrel of oil is
                                                                                                       heating energy (steam).
Wireless Applications             265     Wireless Wonder: DuPont's Infrastructure for                 DuPont, the world's largest producer of titanium dioxide, strengthens its businesses by
                                          Communication, Safety and Success                            making safety, health and environmental issues an integral part of all business activities.
                                                                                                       When the Edge Moor facility wanted to swiftly increase density of monitoring points for
                                                                                                       potentially dangerous, ambient, Chlorine gas, they sought assistance from Emerson for
                                                                                                       configuration and installation of self-contained monitoring devices. This paper will
                                                                                                       demonstrate how Emerson's wireless installation helped increase plant safety at reduced
                                                                                                       cost.
Wireless Applications             293     Wireless Vibration Solution to maintain process in a Power   The North Jeju Thermal Power Plant, located in northern Jeju island, the Unit No.1~2
                                          Plant                                                        internal combustion. This plant is being controlled by Ovation since 2004. Power plant is
                                                                                                       operated by various rotating equipment. This equipment is very important for normal
                                                                                                       operation. So, the customers want to health monitoring of machinery devices. Customer
                                                                                                       and we are expecting good result for predictive maintence and PlantWeb advantage.

Wireless Applications             299     Every Drop Counts Getting the Most Out of Your Refinery      This refinery presentation will highlight where wireless has been already applied in some key
                                          with Wireless                                                application areas as well as some additional example areas where benefits can be realized.

Wireless Applications             301     Data Integration Solutions in the Enhanced Oil Recovery      A recent implementation of measurement and data integration was in the Plains Exploration
                                          Industry Utilizing Rosemount Wireless Technology and         and Producing Company's Hopkins lease in the South Belridge oil field. PXP's engineering
                                          ProGauge Data Management Technologies                        staff recently installed Rosemount's wireless pressure transmitters and Wireless Gateways
                                                                                                       to monitor and manage 120 steam injection wells. ProGauge worked with PXP and Emerson
                                                                                                       to collect wellhead pressure data, calculate steam rate, and provide the PXP operating and
                                                                                                       engineering staff with the injector data in a format to easily monitor and manage the injectors.

Wireless Applications             308     Mobile Worker Unshackles AMS                                 Having implemented a wireless Ethernet backbone in the facility, technicians and operators
                                                                                                       are free to roam with a thin-client window to a fully functional DeltaV workstation. With the
                                                                                                       ability to call up operator displays and AMS from anywhere in the plant, the need for local
                                                                                                       indicators, hand-held calibrators, and separate AMS systems is greatly diminished.

Wireless Applications             345     Advanced Wireless Application for Critical Service Valves    Aera Energy in Huntington Beach , California uses 4 Rosemount 702s to communicate
                                                                                                       the condition of 4 64" critical gate valves. This information is communicated to a centrally
                                                                                                       mounted Emerson 1420 Gateway. This Gateway communicates the information to an
                                                                                                       ioSelect 900mhz radio, which transmits the information 2.5 miles away to the control room
                                                                                                       delivering confirmation that the valves are or are not closed.




                                                                                 Page 87 of 91                                                                                      (Rev. 051010)
                                                                     2010 Emerson Global Users Exchange
                                                                                Workshops


                                Session
                        Track                                         Title                                                                        Abstract
                                   ID
Wireless Applications             360     Wireless the Power Solution!!!                                A 500 MW combined cycle natural gas co-generation plant consisting of two units has
                                                                                                        recently made the initial leap into the wireless arena. They did this by purchasing the
                                                                                                        following:
                                                                                                          1.) 9 DVCs with the PD tier (4 of them being on non-Fisher valves)
                                                                                                          2.) 7 AC tier to PD tier step-ups
                                                                                                          3.) 1 1420 Wireless Gateway
                                                                                                          4.) 16 775 THUMs
                                                                                                          5.) 1 475 HART Communicator
                                                                                                          6.) AMS system w/ Valvelink
                                                                                                         The system will be live in June and the 2 technicians that were designated by the plant to
                                                                                                        be site experts are planning to attend Emerson training within this calendar year.
Wireless Applications             409     Threat Level Orange: Department of Homeland Security          This paper intends to:
                                          evaluates Emerson’s Smart Wireless
                                                                                                         Highlight the Department of Homeland Security (DHS) Control System Security Program's
                                                                                                        (CSSP) mission, capabilities and specifically their ongoing assessment activities
                                                                                                         Discuss an actual assessment of Emerson's WirelessHART compliant systems
                                                                                                         Disclose what was found
                                                                                                         Detail Emerson's response
                                                                                                         Discuss possible future activities

Wireless Applications             411     Smart Wireless Technology brings in Critical Points with      This presentation will cover the current installation (ULC section) and future installations
                                          tremendous upside savings                                     (UU4 & AU2) of wireless product to monitor the Z-Purge junction boxes throughout the the
                                                                                                        BP Texas City Refinerary. BP Texas City has changed its standard practices to require
                                                                                                        continuous monitoring of Z-purged electrical enclosures. Previously the purges were
                                                                                                        allowed to be monitored on operator rounds.

Wireless Applications             413     Easy Goes It: Southern Power's Wireless Approach to           Southern Power is a leading producer of electricity in the US with a generating capacity of
                                          Diagnostics with Legacy Controllers                           42,000 megawatts. Most of their plant is connected to AMS Device Manager to monitor
                                                                                                        device and process health. However 3 combustion turbines, each with 25 devices are
                                                                                                        controlled by a GE control system which is not connected to AMS. By using the Smart
                                                                                                        Wireless THUM Adapter Southern Power was able to connect the 75 devices from these 3
                                                                                                        turbines into their AMS system without any change to their control system.

Wireless Applications             414     What Do You Know About Wireless DP Flow? Explore the         Can I use WirelessHART for my DP Flow applications? What are my options for wireless
                                          Possibilities for Incorporating Wireless into your DP Flow   multivariable measurement? This workshop will demonstrate how to maximize the value of
                                          Applications                                                 your new and existing DP Flow measurements by utilizing WirelessHART. This workshop
                                                                                                       will also discuss actual installations that have shown the benefits that can be achieved with
                                                                                                       wireless DP Flow.
Wireless Applications             448     Got Wireless?: Prepare your plant for modernization with ROI Many process plants only invest in new technology to modernize operations during a
                                          today                                                        scheduled turnaround for reasons of cost, compexity, and risk. Unfortunatley, market forces
                                                                                                       do not wait for scheduled maintenance to affect your bottom line. Smart Wireless solutions
                                                                                                       can be implemented in a hot process with unprecedented ease of use, scalability, and
                                                                                                       forward operability to ensure ROI achieved today seemlessly integrates into your future
                                                                                                       modernized control system. Learn how to acheive benefits of wireless today with an eye
                                                                                                       towards tomorrow.




                                                                                 Page 88 of 91                                                                                      (Rev. 051010)
                                                                     2010 Emerson Global Users Exchange
                                                                                Workshops


                                Session
                        Track                                            Title                                                                   Abstract
                                   ID
Wireless Applications             451     Wireless Plant of the Future                                What does a plant of the future look like when there are so many new technologies? Where
                                                                                                      does one use HART, WirelessHART, Foundation Fieldbus instrument technologies let alone
                                                                                                      modern control systems and asset management solutions all tied together with a plant wide
                                                                                                      network of mobile workers and asset tracking? This paper explores a vision of the future and
                                                                                                      reveals the stepping stones to achieving unprecedented business results by using
                                                                                                      technology to unleash the greatest asset: people.


Wireless Applications             452     Hear the Heat: Steam Trap Monitoring                        Steam traps are generally required to have checks done to them on a regular basis.
                                                                                                      However, resources are sometimes not available and steam traps fail and it could be
                                                                                                      months before the problem is realized. With the new acoustic transmitter, companies can
                                                                                                      have insight on the health of their steam traps without having a dedicated person walking
                                                                                                      around the plant verifying each steam trap. The purpose of this topic is to describe the
                                                                                                      energy losses that a company has due to faulty steam traps.
Wireless Applications             453     WirelessHART Vibration Monitoring                           The P-25 Platform :
                                                                                                       P-25 is a petroleum platform from Petrobras Brazil and is located at Albacora field, in
                                                                                                      Macae - Rio de Janeiro - Brazil .
                                                                                                       This platform was installed in 1996, is a semi-submersible platformand has a installed
                                                                                                      capacity of 100 k barrels/day and 3000 m3 gas/day.
Wireless Applications             454     Wireless monitoring of pH to meet EPA-regulated effluent
                                          requirements at plant perimeter                              Weyerhaeuser needed to meet EPA compliance regulations for the pH of effluent water
                                                                                                      exiting the plant. Alternative reporting solutions were defined and cost-quantified including
                                                                                                      a) 4000 ft. runs of twisted pair wire from three devices to the DCS and b) rerouting analog
                                                                                                      signals through the OPC server to the host, about 1000 ft.

Wireless Applications             461     Does Anyone Hear Me: Your Plant is Crying Out for Help      Every facility has processes going on all the time. It would be impossible for a person to
                                                                                                      manage everything that the plant does. With high work loads, how can a person get the
                                                                                                      information they need to make improvements to their processes? It would be helpful to have
                                                                                                      something looking at every part of the plant but who has time or energy to install and
                                                                                                      maintain a system like that? A company can gain insight into their plant by installing
                                                                                                      Wireless Acoustic Transmitters. The transmitters are easy to install and give valuable
                                                                                                      information that can be used to diagnose problems in the plant.
Wireless Applications             464     Using Wireless to Solve the Chalenges of Remotely Located   This presentation covers a wireless installation located in a remote tank farm at Lubrizol in
                                          Tank Farm                                                   Deer Park , Texas . The project is a fully integrated wireless network into a Delta V version
                                                                                                      9 control system that allowed for pressure and temperature measurements with easy
                                                                                                      expansion capabilities.
Wireless Applications             465     Wi-Fi Asset Tracking and Management                         This presentation will outline and discuss a number of best practices of Wi-Fi real-time
                                                                                                      location solutions (RTLS) and how it can: -Save time in locating staff -Reduce costs by
                                                                                                      tracking and positioning valuable equipment -Allow safety personnel to receive immediate
                                                                                                      alerts about the location, status and condition of staff and guests -Help to automatically
                                                                                                      assign maintenance tasks to the nearest qualified employee and provide valuable feedback
                                                                                                      in terms of forecasting future equipment and staffing needs.

Wireless Applications             471     Control Freak? Fully Wireless Control for Tomorrow.         To date, wireless control applications have typically consisted of a wireless measurement,
                                                                                                      control host, and a wired valve. Thisworkshop will explore new products, technologies,
                                                                                                      andinnovations in a quest to find fully wireless control. Topics will include current wireless
                                                                                                      control, self-organizing mesh technology, fast updates, wireless output devices, and power
                                                                                                      considerations. If applicable, a demonstration of wireless control output will be given.




                                                                                 Page 89 of 91                                                                                     (Rev. 051010)
                                                                      2010 Emerson Global Users Exchange
                                                                                 Workshops


                                Session
                        Track                                           Title                                                                      Abstract
                                   ID
Wireless Applications             475     Emerson helps PEMEX Revitalize Aging Oil Field                This will be a project study demonstrating how Emerson's Smart Wireless technology was
                                                                                                        applied to an unmanned offshore oil field in Mexico. This oil field, one of the largest in the
                                                                                                        world, has seen a 50% production decline in the past 7 years. The presentation will
                                                                                                        emphasize the problem areas the oil field was experiencing, the innovative solutions that
                                                                                                        have been implimented as well as the additional benefits available with our wireless
                                                                                                        technology.
Wireless Applications             478     Budget and Schedule Savings using Wireless Steam              A major international oil and gas exploration and production company uses Steam Injection
                                          Injection Flow Monitoring                                     for Enhanced Oil Recovery in Oman. They were using Dynamic Flow Computers to monitor
                                                                                                        the steam flow into each well, and bringing this data back using an RTU. They investigated
                                                                                                        the use of Emerson's Smart Wireless to bring the same data back more economically. Pilot
                                                                                                        installations proved that the technology worked in their application; an initial trial
                                                                                                        demonstrated installation time savings.
Wireless Applications             486     WirelessHART Reliability…      …after 100 Million Hours of    By the first quarter of 2010, some analysts have estimated that fields instrumentation
                                          Operation                                                     enabled by WirelessHART has achieved more than 100 Million hours of reliable and secure
                                                                                                        operation in the most demanding environments across the world.

                                                                                                         This short course focused on introducing the technology underpinnings that enables
                                                                                                        WirelessHART to achieve high levels of operational reliability and security. The course is
                                                                                                        crafted in a language suitable for technology managers and decision makers in the process
                                                                                                        control space.
Wireless Applications             513     Blast Furnace nozzle monitoring using wireless transmitters   The blast furnace in the plant has 24 nozzles located around it that supply hot air and
                                                                                                        carbon dust to achieve even heating in the furnace. Flow through the nozzles should be
                                                                                                        even and constant to have optimal energy consumption and proper operation. Continuous
                                                                                                        nozzle issues lead ArcelorMittal automation department to find out a way to identify nozzle
                                                                                                        problems so that they are corrected as soon as possible.
Wireless Applications             521     Good Vibes about Wireless at Chevron – Best Practices for     Chevron has conducted extensive research into emerging options for wireless monitoring.
                                          Wireless Vibration Monitoring                                 This session will highlight their experience with Emerson's wireless monitoring system as it
                                                                                                        applies to various asset types including pumps and reciprocating compressors. Vibration
                                                                                                        monitoring is central to these applications, but it is combined with other parameters for
                                                                                                        maximum effectiveness. [Note: There is an intended co-presenter from Chevron pending
                                                                                                        mgmt approval, but I could not enter his name yet.]

Wireless Applications             523     Geothermal field monitoring using Fieldbus and wireless       Cerro Prieto is the second largest geothermal field in the World. There are 165 steam wells
                                          instrumentation                                               in operation that supply around 42.15 million tons of steam per year and produced 4,935
                                                                                                        Gigawatts hour during 2009.
                                                                                                        To be able to manage the steam wells properly, Comision Federal de Electricidad is
                                                                                                        automating the field. The first phase of the project is a SCADA system with foundation
                                                                                                        Fieldbus and wireless transmitters for 19 wells.

Wireless Applications             524     DeltaV plus Delta Vibration - Integrating vibration into a    This workshop will outline the best practices for integrating wireless vibration monitoring into
                                          Process Automation System                                     a DeltaV system for process automation - including lessons learned from a test installation
                                                                                                        at RockTenn facility. [The end user at this site is submitting another paper to present at
                                                                                                        Exchange, and has expressed strong interest in partcipating in this workshop as well.
                                                                                                        However, I don't have written approval to list him as a co-presenter yet, although I am quite
                                                                                                        sure that this guy will come through.]




                                                                                   Page 90 of 91                                                                                     (Rev. 051010)
                                                                     2010 Emerson Global Users Exchange
                                                                                Workshops


                                Session
                        Track                                          Title                                                                        Abstract
                                   ID
Wireless Applications             527     PEMEX Intelligent Field using wireless technology              PEMEX's Cantarell field is one of the largest oil fields in the world, on 2003, was contributing
                                                                                                         60 percent of Mexico's crude oil production. However, the field has been declining to about
                                                                                                         30%. Operations consist of 200 production wells on more than 50 platforms, which have
                                                                                                         limited or non-existent power availability and communications infrastructure to transmit data
                                                                                                         back to the onshore operations facility. PEMEX installed wireless technology to enable
                                                                                                         better management of the field, increase worker safety and improve environmental protection

Wireless Applications             532     Four for One: Increasing Process Efficiency using Wireless     A major Chemical manufacurerfound throughanalysis and lab testing, that improved
                                          Technology                                                     monitoring of concentration and temperature of a chemical reagent could increase
                                                                                                         throughput and reduce process costs, but individual monitoring of numerous chambers
                                                                                                         placed estimated implementation above threshold for project approval. The use of dual input
                                                                                                         conductivity analyzers for concentration and temperature measurement mated to THUM
                                                                                                         Smart Wireless Adapter, allowed the desired data to be transmittedeconomically toplant
                                                                                                         historian for report generation and alerting.
Wireless Applications             545     Intrusive and Non-Intrusive Corrosion Monitors Integrated      Opportunity crudes (where corrosives vary) have increased the focus on corrosion
                                          Into One Online System                                         monitoring. Roxar is the only provider of both intrusive and non-intrusive corrosion
                                                                                                         monitoring that can be combined into an integrated online corrosion system for improved
                                                                                                         economic performance and integrity in refineries and upstream operations. With reference to
                                                                                                         Reliance Industries' Jamnagar Refinery (India), this paper highlights how Roxar's CorrOcean
                                                                                                         CorrLog, FSMLog, Fieldwatch software and Emerson's Smart Wireless infrastructure, are
                                                                                                         maximizing the benefits of corrosion monitoring and integrity management.

Wireless Applications             552     Tattletales Will Tell "No Tales, No More": How Wireless   It is best practice to install rupture disks in front of pressure relief valves (PRVs), in services
                                          HART Improves Safety and Reliability at Oxy Vinyls VCM    where leakage of chemicals through a relief valve are harmful to people or environment. If
                                          Facility                                                  back pressure builds up in the space between the disc and the pressure relief valve, a
                                                                                                    rupture disc will not burst at design pressure. This could occur should leakage develoop in
                                                                                                    the rupture disc due to corrosion creep, fatigue, or physical damage. In many cases, a
                                                                                                    gauge (tattletale) is used to identify leaks. Operators are required to make rounds to check
                                                                                                    "tattletales", which is time intensive (costly).
Wireless Applications             554     Monitoring Explosion Hazards With Wireless and Foundation An explosion and fire at a sugar factory two years ago brought a renewed interest in
                                          Fieldbus                                                  monitoring potentially hazardous sources in the manufacturing, handling, and storage of
                                                                                                    sugar. American Crystal Sugar proactively put together a plan to address these potential
                                                                                                    hazards in the Class II, Division 1 & 2 Group G areas. To eliminate the chance for explosion
                                                                                                    this project includes the removal of ignition sources and the monitoring of sources that could
                                                                                                    become ignition sources using wireless and bus technologies.




                                                                                  Page 91 of 91                                                                                       (Rev. 051010)

								