scope of work template
							CBT 4 - Safety Equipment - Maintenance &
     Records & Safety Record Folder




                                     1
   Course Format

 Course is made up of this power point presentation
  accompanied by the short questionnaire next to you!
 We will also review the Hanseatic Safety Records
  Folder (SRF) regularly throughout this course
  (references to HSC are printed in brownish colour)
 Please ask an agency employee to assist whenever
  required.
 You can advance through the presentation by hitting
  the “ENTER” key with your desired speed!
 You should be able to complete in 2.5 hours
                                                  2
          Check on yourself
Please read the questionnaire and answer
the questions to your best knowledge
without consulting this presentation or an
instructor.
Be fair to yourself!
Complete it (not more than 8-10 minutes),
turn it around and continue here.
                                      3
           Course Contents
1. Introduction   (slide 5)


2. Maintenance and Recording of Maintenance, Test
   & Inspection for Life Saving Appliances (slide27)

3. Maintenance and Recording of Maintenance, Test
   & Inspection for Fire Fighting Appliances (slide 59)

4. Maintenance and Recording of Maintenance, Test
   & Inspection for Miscellaneous Items (slide 98)


                                                    4
                      1. Introduction
                                  -    References -
   To assist the officers in charge of maintenance and those performing
    the inspection and maintenance, the following publications have been
    used as reference in the preparation of this presentation: -

   HSC Safety Records Folder (Ref HSC/SER01/98 REV 00);
   HSC Quality & Fleet Manuals Volume 1, 2 & 3;
   HSC Operational Procedures & Contingency Plans Manual (OPCP);
   SOLAS 2001 Edition;
   OCIMF Vessel Inspection Questionnaire (2nd Edition 2000);
   CDI Ship Inspection Report 2000 Edition with further reference to the
    IBC Code & BCH Code; &
   ISGOTT 23rd Edition.

! Important ! On board please consult the latest editions of above publications or documents!
                                                                                        5
Cross Referencing

         Wherever relevant
          publications are indicated -
          these documents MUST be
          consulted for more detailed
          information;
         SOLAS is in a continual
          state of update and
          amendment and every
          effort is made by Hanseatic
          to keep the SRF updated.

                                  6
     Instructions for Onboard
           Maintenance

Instructions should include:
 Checklist for use when carrying out the inspection;
 Maintenance & repair instructions;
 Schedule of periodic maintenance;
 Diagram of lubrication points with recommended
  lubricant;
 List of replaceable spare parts;
 List of sources of spare parts (authorized dealers);
 Log for maintaining records of inspections &
  maintenance.
                                                         7
Responsibility for Maintenance

            Overall responsibility lies with
             the Master;
            However, the Chief Officer is
             designated as the Safety
             Officer onboard and he is to be
             assisted by the Second
             Engineer;
            Actual inspection and
             maintenance work may be
             delegated to Junior Officers and
             Ratings, provided they are
             competent to carry it out.
                                            8
Responsibility for Maintenance


           Duties must only be delegated if
            the Master & Chief Officer consider
            the Junior Officer and/or Rating
            proficient;
           If required, training must be given
            to any person(s) delegated to carry
            out maintenance work;
           However, under all circumstances,
            the responsibility lies with the Chief
            Officer and ultimately, the Master.
                                             9
Maker’s Instructions

          Must be available for all safety
           equipment onboard the ship;
          MUST always be referred to
           when scheduling maintenance
           and inspection;
          If appropriate, can be kept in
           the relevant section of the SRF
           for easy reference;
          Maker’s instructions and
           guidance must be complied
           with at all times.

                                       10
Safety of Personnel
  Crewmembers carrying out maintenance &
   inspection of safety equipment MUST always
   follow laid down safety procedures to prevent
   accidents or injury;
  Adhere to check lists where required
   and carry out a risk assessment;
  Communication is important, as always;
  Equipment must be isolated (if required) and
   warning notices posted;
  When working outside the accommodation,
   etc assess the weather conditions and always
   use PPE and additional safety harness &
   working life vest; &
  Verify that task is clearly understood by
   personnel and can be carried out
                                               11
State of Readiness

         Information given on
          maintenance & inspection
          is for guidance only;
         YOU must determine the
          level of maintenance
          required in order to keep
          the equipment in a
          constant state of
          readiness.

                                 12
do not “OVER” inspect

          It is NOT a requirement that
           every piece of equipment
           listed in the SRF is inspected
           every week;
          This leads to “over”
           inspection and it becomes a
           verification that the
           equipment is in place;
          Such practices DO NOT allow
           sufficient time for thorough
           maintenance and inspection
           of the equipment.
                                      13
        do not “OVER” inspect

 Many people believe it is the records that we must
  maintain;

 This is NOT true, records will NOT save your life!!!;

 SOLAS II-2, Reg 21 & SOLAS III, Reg 20 give clear
  information regarding the frequency of inspections and
  readiness for use of all fire fighting and life saving
  appliances;

 Plan your inspections and maintenance to meet the
  stated requirements and ensure that all safety
  equipment is well maintained - take your time and do
  the job properly.
                                                           14
Hanseatic Safety Records
     Folder (SRF)
             Contains details of all Safety
              Equipment carried onboard
              your vessel; &

             Identifies the
              maintenance &
              inspections that are to be
              carried out to the Safety
              Equipment so as to meet
              the requirements of
              SOLAS, CDI & the OCIMF
              VIQ.
                                        15
 Hanseatic Safety Records
      Folder (SRF)
                        This is the only document
                         onboard for maintaining
                         records relating to the
                         safety equipment;

Safety Record   .0      The latest test certificates
Folder (SRF)    fety     form shore side testing
                         centres must be kept in
                         Master’s File 2.0 (Minor
                         Certificates - Safety);
                        MUST be maintained on
                         the Bridge.
                                                 16
Initial Completion of the SRF
              Indicate the number of units
               carried onboard & the
               number required to be
               carried;
              Vessel will usually carry more
               than is required;
              Accurate information can be
               gathered from ship’s plans,
               certificates & Safety
               Equipment Survey
               attachment to the certificate.
                                         17
   Not Applicable Sections of
            the SRF
 Designed for use onboard any type of vessel;
 Includes requirements for equipment carried by all
  ship types;
 Some parts of the folder may not apply to all
  vessels;
 Can be removed and a notation “Not Applicable to
  this ship” made against the relevant section in the
  List of Contents - refer to HSC Operational Bulletin
  QA/004/AW/98.

                                                     18
Entries into SRF
      Entries must contain specific details
       of what action or maintenance has
       been taken;
      Entries must also include reference
       to other instruction, i.e. “checks
       carried out as per maker’s
       instructions section 8.5 - dogs on
       access doors lubricated and
       adjusted”;
      Each entry must be signed by the
       appropriate person carrying out the
       work - if an engineer or electrician
       tests the emergency lighting, they
       must sign the entry.
                                        19
SRF v Deck Log Book

       Is an appendix to the Deck Log Book
        and MUST be completed in INK;
       Time & Type of drill must be
        recorded in the Deck Log Book;
       Full details of Drills, Inspections
        and Maintenance of Safety
        Equipment must be made in the
        SRF;
       Please note that the Official
        Logbook must still contain
        entries regarding Drills &
        Inspections and Maintenance of
        Safety Equipment.
                                       20
Copying Pages

       Only original pages of the
        present revision of the SRF
        must be used;
       DO NOT make photocopies or
        reproduce pages on a
        computer; &
       If you require additional
        pages use the pages in
        section 6 of the SRF or
        contact HSC QMS Dept.

                                    21
Form 67 A/B
   The SRF is an “onboard” record
    of the testing, inspection and
    maintenance of all safety
    equipment;
   Under ISM 10.2, details of such
    maintenance and testing must be
    reported to the Company;
   Form 67 A/B has been issued for
    the purpose of reporting; &
   Form is to be sent monthly to the
    Technical Dept.
                                 22
  The SRF Section by Section

 Section 1 - Introduction & Record of Revision;
 Section 2 - Life Saving Appliances;
 Section 3 - Fire Fighting Appliances;
 Section 4 - Miscellaneous Items;
 Section 5 - Records of Drills & Inspections; &
 Section 6 - Spare Record Sheets.

                                                   23
1.1 Master’s Verification

            Once a month, the Master
             is to inspect the SRF and
             ensure that all regulations
             and requirements are
             being met;
            He must sign in the space
             provided as evidence that
             he accepts that the records
             are a true and accurate
             reflection of the status of
             the equipment and the
             drills carried out.       24
1.2 Safety Officer Onboard
            This section is used to
             identify the name of the
             ship’s Safety Officer and his
             time onboard;
            The Safety Officer is the
             Chief Officer (QM Ch 4
             Addendum 01);

            His duties are clearly stated
             (FM Vol 3, Ch 3, Appendix 01),
             reference should also be
             made to the Code of Safe
             Working Practices.
                                              25
1.3 Onboard Review of
     Procedures
        Reviewed once during each Master’s
         contract;
        One review must be in October of
         each year to coincide with the
         annual Management Review ashore;
        Any changes to onboard procedures
         MUST be forwarded to the
         Designated Person and reference to
         this message stated here;
        If no changes are required - this
         must also be stated as “System
         Reviewed & Satisfactory”.
                                         26
      Section 2 - Life Saving
            Appliances
   Lifeboats;
   Rescue Boat;
   Liferafts;
   Lifejackets;
   Lifebuoys;
   Portable Radios/EPIRB/SART;
   Immersion Suits/TPA;
   Pyrotechnics;
   SOLAS Training Manual;
   Muster Lists;
   Emergency Lighting;&
   Safety Signs
                                  27
                       2.1 - Lifeboats
 SOLAS III, Reg 20.6; OCIMF 5.16
  & CDI Section 10 - lifeboats and
  their launching equipment must be
  in good condition;
 Weekly inspection of lifeboat &
  davits to confirm they are ready for
  use;
 Falls are to be inspected to see that
  wires are undamaged and that the
  wire is laying correctly on the
  winch drum;
 Securing devices, hooks, pennants,
  harbor pins, etc must be secure,
  yet easily released.
                                          28
     Lifeboat - Weekly Inspection
 All items on the davits are to be thoroughly checked as
  part of this inspection, particular attention must be paid to
  the brake cut-out (limit switches). These must be
  thoroughly tested each time the boat is lowered out of its
  stowed position - any deficiency must be rectified
  immediately;
 All grease points are to well lubricated and fall wires are to
  be greased - during the routine lowering of the boat, check
  that all davit sheaves are turning smoothly;
 The lifeboat hull is to be inspected to verify good order;
 CDI 10.28 - Markings (retro-reflective tape, identification
  from above, etc.); &
 The disengaging gear is to be inspected.
                                                               29
             Weekly Inspection continued
 A thorough external inspection is to be
  made including: -
 Rudder & Propeller;
 All ropework (including painters if
  applicable) is to be inspected to ensure
  that it is secured and in good condition;
 Embarkation Ladders (if applicable) -
  SOLAS III Reg 11.7, CDI 10.32 -
  remove canvas cover, “air” the ladder
  and check condition of ropework and
  steps ; &
 Records of weekly inspection &
  maintenance to be recorded in SRF
  Section 2.1.                                30
       Lifeboat Monthly Inspections
 SOLAS III, Reg 20.7 - monthly
  inspection of each item of
  lifeboat equipment is to be made
  to ensure that it is in place and
  in good order with particular
  attention to the following:
 First Aid Kit, secure & dry;
 Pyrotechnics, secure & dry;
 Torch operational & spare
  batteries available;
 Water tanks full (date last
  changed);
 If freefall boat - one SART must
  be located inside the boat; &
 Food Rations, secure & dry.
                                      31
     Monthly Inspections continued
 Fuel tank(s) full;
 Fire Extinguisher in good order -
  recharged as required;
 Electrical & Hydraulic systems in good
  order;
 Self contained air system fully
  charged - date last serviced;
 Lifeboat Compass in good order;
 Oars & Crutches (if applicable);
 Drain valve cap or plug + marking; &
 Records of monthly inspection &
  maintenance to be recorded in SRF
  Section 2.1.
                                           32
             Seating Arrangements


   CDI Section 10.21;
   Seating positions within the
    lifeboat must be clearly
    marked;
   For a freefall lifeboat, a
    seating arrangement plan
    must be posted at suitable
    locations around the vessel.




                                    33
                         Seat Belts

   CDI Section 10.23;
   Lifeboat seatbelts must be
    checked and their condition
    maintained;
   The securing point is to be
    strong;
   The webbing strap is to
    remain in good condition; &
   The buckle is to be free to
    operate smoothly.


                                      34
               Non Skid Surfaces


   CDI Section 10.24;
   Lifeboat surfaces on which
    persons might walk must
    have non skid surfaces;
   This applies to both
    internal & external
    surfaces.



                           Non Skid Surface   35
               Watertight Hatches

   CDI Section 10.25;
   Watertight hatches must be
    maintained in good
    condition;
   Hinges & Rubber seals must
    be in good condition;
   Hatch must provide a good
    seal with all dogs secured; &
   All securing dogs must be
    free to move with the open
    or closed position, marked.
                                    36
               2.2 Rescue Boat
   SOLAS III, Reg 14, 17, 19
    3.3.6 & 7, 20, 31.2, 35 & 36;
   CDI 10.48 - 10.59;

   SOLAS III Reg 20.6.1 -
    Weekly inspection and
    maintenance as for lifeboat is
    to be carried out to ensure
    that Rescue boat is ready for
    use;
 Records of weekly inspection
  & maintenance to be
  recorded in SRF Section 2.2.

                                     37
    Rescue Boat Weekly Inspection

   Weekly inspection and
    maintenance should include: -
   Engine & Propeller;
   Rudder, Tiller & Towing Device;
   Remote Launching Device must be
    tested and reset; &
   SOLAS III Reg 20.6.2 - Weekly run
    engine(s) for 3 minutes and test
    engaging of gear box provided the
    ambient temperature is above the
    minimum required for starting and
    running the engine.

                                        38
Rescue Boat Monthly Inspection

   Monthly inspections must check the condition of: -
   Waterproof Torch/Flashlight;
   Searchlight;
   Thermal Protective Aids; &
   Other small equipment.

   Weathertight stowage arrangements must also be
    checked; &

   Records of monthly inspection & maintenance to be
    recorded in SRF under Section 2.2.
                                                         39
                     2.3 Liferafts
   SOLAS III Reg 11, 12, 13.4, .5, & .6,
    16, 19.4.2.1 & 4.3, 20, 35 & 36;
   CDI Section 10.61 - 10.75;
   OCIMF 5.16.2;

   Weekly inspection and
    maintenance to be carried out to
    ensure that liferafts are ready for
    use;
 Records of weekly inspection &
  maintenance to be recorded in
  SRF Section 2.3.
                                            40
          Liferaft Weekly Inspection
   Casing undamaged and seals are
    intact;
   Container is correctly marked;
   Painter is correctly secured to
    the hydrostatic release;
   Hydrostatic release “weak link”
    is correctly secured between the
    ship and hydrostatic release or
    painter;
   Holding cradle is securely
    attached to vessel; &
   Removable handrails or chains
    are free and easy to release.


                                       41
           Liferaft Monthly Inspection
   SOLAS III, Reg 20.7;
   CDI Section 10.72 & 10.77 & 10.78;

   In addition to the weekly inspection,
    once a month, the following must be
    inspected and maintained: -
   Condition of Embarkation ladder
    ropework and steps must be checked -
    remove the canvas cover and “air” the
    ladder;
   Liferaft operating instructions must be
    displayed in the vicinity of the liferaft; &
   Records of monthly inspection &
    maintenance to be recorded in SRF
    under section 2.3.
                                                   42
                Davit Launched Liferaft
                Operating Instructions


   SOLAS III, Reg 9;
   CDI Section 10.78;

   Instructions for the use of davits
    and davit launched life rafts
    must be posted in the vicinity of
    the liferaft embarkation area.

   Remember two types of
    launchable liferaft – padeye
    inside or outside the casing!
    Check the label and familiarize
    your crew



                                          43
                  2.4 Lifejackets
   SOLAS III Reg 7.2, 20, 32, 35 & 36;
   CDI Section 10.80;

   Lifejackets need only to be inspected
    and maintained monthly in order to
    verify: -
   they are to be located as per list,
    including jackets for persons on watch
    or for use at remotely located survival
    craft stations;
   tapes are secure; &
   vessel’s name is clearly indicated.
   Record of inspection and any
    maintenance must be recorded under
    section 2.4 of the SRF.
                                              44
                Lifejackets continued
   Monthly inspection and
    maintenance must also include: -
   Jacket must be fitted with a whistle
    and retro-reflective tape;
   Self Igniting Light is fitted and
    expiry date or date of last battery
    change or battery expiry date is
    available;
   Also check for manufacturer’s name
    or trade mark, class society
    endorsement (if any), name or
    brand of the lifejacket; &
   The jacket should be marked with
    the words “Person of 32 Kg or
    more” in 12mm high letters.

                                           45
               Lifejackets continued

   Monthly inspection and maintenance must
    also include: -
   Verification that the year of manufacture
    is shown on the jacket - maybe together
    with manufacturer’s details; &
   The word “Front” is also visible on the
    front part of the jacket.
   The location of lifejacket storage boxes
    must be identified by IMO approved
    signs; &
   The condition of external lifejacket
    storage boxes must be verified - hinges,
    rubber seals and open/close
    arrangements.
                                                46
                   2.5 Lifebuoys
   SOLAS III Reg 7.1, 20, 32.1, 35 & 36;
   CDI Section 10.83 - 10.84;
   OCIMF VIQ 5.16.5;
   Lifebuoys need only to be inspected and
    maintained monthly in order to verify
    that each lifebuoy: -
   is marked with ship’s name & port of
    registry;
   is fitted with 4 bands of retro-reflective
    tape - tape must be in good condition; &
   has a grabline (of not less that 9.5mm
    diameter) secured around it in 4 places -
    line must be in good condition.
                                                 47
                  Lifebuoys continued

   For those lifebuoys fitted with a
    buoyant line, the line must be at
    least 8mm in diameter and non
    kinking;

   Length of line should be not less
    than twice the height which it is
    stored above the waterline in the
    lightest sea going condition or 30 m
    whichever is greater;

   It must also be resistant to
    deterioration from sunlight; &

   Records of maintenance &
    inspection must be kept in section
    2.5 of the SRF.                        48
         Lifebuoys with Self Igniting
                   Lights
   For those lifebuoys fitted with a self
    igniting light: -

   All attachments and securing
    arangements must be in good order;

   Check condition of cabinet hinges and
    open/close arrangements;

   Battery operated lights must be
    inspected monthly - watertightness &
    brightness of light verified;

   Date that batteries were changed must
    be marked on body of the light and
    recorded in the maintenance section of
                                             Check condition of
    the SRF under section 2.5.
                                              “o” ring or seal
                                                           49
           Lifebuoys with Self Activating
               Light & Smoke Floats

   For those lifebuoys fitted with a self    Release Lever
    activating light & smoke float: -

   All attachments must be in good order;

   Release lever must be free and easily
    identified;

   Weight of the lifebuoy must be at least
    4 Kg and the line between the float and
    the lifebuoy must be 4 m long;

   Date that batteries were changed must
    be marked on body of the float and
    recorded in the maintenance section of
    the SRF under section 2.5.
                                                       50
2.6 Portable Radios, EPIRB & Radar
           Transponder
   SOLAS III, Reg 6; CDI 1.4.16 - 18; OCIMF VIQ
    5.16.3;

   To be inspected at least monthly, follow
    manufacturer’s test and maintenance instructions for
    individual units;

   SART can be tested during lifeboat drills - their signal
    should be visible on the ship’s radar - if a freefall
    lifeboat is fitted, one SART must be permanently
    stored inside the boat;

   Date of last battery change or battery expiry must be
    shown on the exterior of the unit;

   For EPIRB, inspection and maintenance must also
    include hydrostatic release; &

   Records of inspection, test and maintenance must be        51
    kept in the SRF under section 2.6.
          2.7 Immersion Suits &
          Thermal Protective Aids
   SOLAS III, Reg 7.3, 32.3, 35 & 36;
   CDI Section 10.55;

   To be inspected at least monthly;

   Verify that suits are stored in the
    correct location and that suits are
    suitably protected from damage;

   Check condition of self igniting light and
    check battery expiration date; &

   Records of inspection, test and
    maintenance must be kept in the SRF
    under section 2.7.
                                                 52
        2.8 Bridge Pyrotechnics &
        Line Throwing Appliances
   SOLAS III, Reg 6, 18, 19, 20, 35 & 36;
   CDI Section 10.90 - 93; OCIMF 5.16.6;

   Line Throwing Appliances & 12
    Parachute Flares and Hand flares - to
    be inspected monthly;

   Verify that units are stored in the
    correct location and suitably protected
    from damage;

   Check expiration date of projectiles and
    igniters (shown on unit casing); &

   Records of inspection and maintenance
    must be kept in the SRF under section
    2.8.
                                               53
     2.9 SOLAS Training Manuals,
    Muster Lists & SOLAS Certificates

   SOLAS III, Reg 35; CDI SIR 1.2.2; OCIMF VIQ 5.15;
   SOLAS Training Manual - to be inspected quarterly to
    ensure that all information is up to date and ship specific;

   SOLAS III, Reg 8 & 37; CDI Section 7.47; OCIMF 5.1.9;
   Fleet Manual Vol 1, Chapter 3, Section 9.1
   Muster Lists - to be updated immediately after every crew
    change;
   Must contain all information required by SOLAS; &
   Must give full name & rank of crewmember and be signed
    by present Master.

                                                             54
        SOLAS Training Manuals, Muster
          Lists & SOLAS Certificates
   SOLAS I, Reg 16; Fleet Manual Vol 1, Chapter 3, Section 2.5

   Certified copies of ALL SOLAS certificates must be posted in
    the accommodation: -
   Cargo Ship Safety Construction Certificate;
   Cargo Ship Safety Equipment Certificate;
   Cargo Ship Safety Radio Certificate;
   International Loadline Certificate;
   IOPP; &
   ISM DoC & SMC.

   Records of inspection and amendment must be kept in the
    SRF under section 2.9.

                                                              55
          2.10 Embarkation Deck
             Emergency Lighting
   SOLAS II, Reg 43 & SOLAS III, Reg 11.4 &
    16.7; CDI 10.79;

   Emergency Embarkation Lighting is to be
    tested at each Abandon Ship Drill;

   Inspect and test all emergency lighting and
    ensure that it functions from the emergency
    power source;

   If maintenance is required on “gas tight”
    fittings, ensure appropriate precautions are
    taken and power supply is isolated until
    fitting is secure; &

   Records of inspection and maintenance
    must be kept in the SRF under section 2.10.
                                                   56
             2.10 Safety Signs
   SOLAS II-2, Reg 28.1.10 & III,
    Reg 11.5; CDI 10.96; OCIMF
    VIQ 5.1.9;

   To be inspected monthly and if
    necessary, luminescence
    verified;

   Inspect condition of emergency
    exit signs and ensure that they
    “glow in the dark”;

   If not, they must be replaced.

   Records of inspection and
    maintenance must be kept in
    the SRF under section 2.10.
                                      57
Take a break, before you carry on! 10 minutes.




                                            58
    Section 3 - Fire Fighting
          Appliances
 Fire/Foam Hydrants;
 Fire/Foam Hoses & Nozzles;
 Fire/Foam Isolation Valves;
 Portable Extinguishers;
 Fixed Dry Powder System;
 Fixed CO2 System;
 Fixed Foam System;
 Fixed Halon System;
 Cargo Hold Sprinkler System; &
 Deck Water Spray Systems.
                                   59
    Section 3 - Fire Fighting
       Appliances (cont)

 Fireman’s Outfits;
 Paint Locker Extinguishing
  System;
 Portable Foam Equipment;
 International Shore Connection; &
 Fire Control Plans.




                                      60
   3.1/3.3 - Fire/Foam Hydrants
 SOLAS II-2, Reg 4 & 21; CDI SIR 9.24;
  OCIMF VIQ 5.9.2;
 Quarterly inspection of fire hydrants to
  confirm they are in good condition &
  ready for use;
 Check condition of rubber washers -
  correctly fitted and not perished;
 Any leaks must be repaired;
 Protective caps must be fitted when not
  in use; &
 If coupling has a spring clip
  arrangement - must be inspected and
  lubricated to maintain good order.
                                             61
      3.2/3.4 - Fire/Foam Main,
          Hoses & Nozzles
 SOLAS II-2, Reg 4, 21 & 61.7,
  FM Vol 2, Ch 4; CDI SIR 9.23, 9.26 -
  9.29; OCIMF VIQ 5.9.2;
 Each hose and hose box is to be
  marked with identification number
  corresponding to ID number in SRF;
 Quarterly inspection & testing of
  hoses- ensure that hoses are in
  correct location; &
 Verify condition of hose box - hinges
  and open/close arrangements.
                                          62
      Fire/Foam Main, Hoses & Nozzles


 A Fire Box contains a workable
  nozzle, a fire hose and a spanner
  (in some cases the spanner might
  be located close to the hydrant)
 If hose couplings have spring clip
  retainers, ensure these are
  lubricated, free to operate and
  undamaged; &
 Condition of securing bands must
  also be inspected.

                                       63
                   Hose Couplings


 Quarterly inspection of fire
  hoses must also verify
  condition of hose couplings;
 Rubber seals must be
  inspected to ensure they are
  fitted correctly and have not
  become brittle; &
 In most cases, lubrication
  need NOT be applied to the
  couplings.



                                    64
       Fire Hose - Pressure Test
 Refer FM Vol 2, Ch 4, Section 6.3 vii, Paragraph 91.25-20( 4);
 To be carried out ANNUALLY - Test to working pressure of
  the system but not less than 100 psi;
 Fire pump running and one valve (anchor wash) or hydrant
  open to release fire main pressure;
 THIS IS A 2 MAN JOB - One man to control the nozzle, one
  man to control the hydrant;
 Hydrant and nozzle both open - once hydrant full open, nozzle
  to be closed gradually - check hose and couplings for leaks;
 Close hydrant & drain hose - if OK, leave to dry and place in
  hose box. If damaged, replace with spare. Make notation in
  SRF.
                                                            65
      Fire Hose - Miscellaneous
 Fire hoses/nozzles are provided as
  per ship’s Safety Plans;
 Such fire hoses are NOT to be
  used for taking fresh water or
  washing down decks or cargo
  holds;
 This will dramatically shorten the
  useful life of a fire hose;
 Condemned, old or only hoses
  specifically provided for this
  purpose MUST be used; &
 Hoses used for fresh water or
  washing down, MUST be marked
  accordingly.

                                       66
Nozzles

   Should also be numbered and
    stored at the appropriate
    location;
   Quarterly inspection must
    also verify condition of
    nozzles;
   For Jet/Spray type nozzles -
    must be free to move and
    lubricated if necessary; &
   Rubber seals must be
    inspected to ensure they are
    fitted correctly and have not
    become brittle.

                                67
    3.5 - Isolation Valves
 SOLAS II-2, Reg 4, Section 6.3 & 21;
  CDI SIR 9.25; OCIMF VIQ 5.9.4;
 Quarterly inspection of isolation
  valves to confirm they are in good
  condition & ready for use;
 Valves should be lightly lubricated,
  turned the full length of the spindle
  and reset to their normal operating
  position;
 Spindle to be lightly lubricated again.


                                            68
    Fixed Fire Fighting System -
          Isolation Valves
 SOLAS II-2, Reg 4, Section 6.3 & 21; CDI SIR 9.25;
  OCIMF VIQ 5.9.4;
 Quarterly inspection of isolation valves to confirm they
  are in good condition & ready for use;
 Should be easily identified by color or number - marking
  to be renewed if required;
 Valve numbers must always correspond to operating
  instructions;
 Valves should be lightly lubricated, turned the full length
  of the spindle and reset to their normal operating
  position;
 Spindle to be lightly lubricated again.
                                                           69
   3.6 - Portable Extinguishers
 SOLAS II-2, Reg 6 & 21;
  CDI SIR 9.36 - 9.42; OCIMF VIQ 5.9.5;
  FM Vol 2, Chapter 4.6

 All portable extinguishers to be
  individually numbered and entered into
  SRF;
 Monthly inspection of portable
  extinguishers to confirm they are in
  good condition, correctly color coded,
  stored in their mounting brackets &
  ready for use; &
 Spare charges and refills must be
  available and inventory recorded.
                                           70
        Portable Extinguishers
 Quarterly inspection of portable
  extinguishers to check: -
 Activation & delivery devices in
  good order;
 Water level verified;
 Liquid foam level to verify (if
  possible); &
 Open up casing top, inspect,
  remove and weigh CO2 charges -
  full and empty weight is stamped
  on neck of CO2 cartridge.

                                     71
       Portable Extinguishers

 Quarterly inspection of portable
  extinguishers to check: -
 Carbon Dioxide extinguishers -
  take off bracket and weigh;
 If showing less than 90% of
  specified weight - extinguisher to
  be replaced and shore based
  servicing arranged; &
 Dry Powder extinguishers must
  be removed from bracket and
  shaken in order to “fluff up”
  powder.
                                       72
             E/Room Dry Powder
                Extinguishers

 Quarterly inspection of portable
  extinguishers to check: -
 Activation & delivery devices in
  good order;
 Every 6 months - pressure of
  activation cylinder to be verified;
 Dry Powder extinguishers must
  be opened and the powder
  “fluffed up”.

                                        73
     3.7 - Fixed Dry Powder Systems
 SOLAS II-2, Reg 6 & 21;
 CDI SIR 9.55 - 9.59; OCIMF VIQ 5.9.10;
 Quarterly inspection to check: -
 All valves to be clearly numbered and
  corresponding to operating instructions;
 Valves tested (where possible) for ease
  of operation - DO NOT activate N2
  cylinders; &
 Pressures of pilot & activation bottles to
  be verified; &
 Every 6 months, open up tank and fluff
  up powder.
                                               74
        Fixed Dry Powder Systems


 Quarterly inspection of hoses &
  nozzles to check: -
 Nozzles are in good condition;
 Free to open and close;
 Lubricated as required; &
 Strongly connected to discharge
  hose.



                                    75
        Fixed Dry Powder Systems

 Quarterly inspection of hoses &
  nozzles to check: -
 Hose box hinges and securing
  arrangements are in good
  condition;
 Rubber seals are in good
  condition to prevent water
  ingress;
 Hoses are in good condition - no
  splits, cuts or tears; &
 No damage due to kinking or
  incorrect stowage.                 76
          Fixed Dry Powder - Monitors

 Quarterly inspection of monitors to check: -
 Unit is lubricated and free to turn;
 Test monitor and remote activation points where
  feasible - refer maker’s instructions.




                                                    77
      3.8 - Fixed CO2 Systems
 SOLAS II-2, Reg 5 & 21; CDI SIR 9.33 -
  9.35; OCIMF VIQ 5.9.10;
 Provided for E/Room, Cargo Pump Room,
  Cargo Holds or a combination of any or all of
  these areas;
 Monthly inspection to verify that all CO2
  cylinders are secure - check the securing
  arrangements for each cylinder;
 Check activation mechanism and confirm that
  links to each bank of cylinders are in good
  condition;
 Operating instructions are clearly posted; &
 If room is locked - key(s) must be readily
  accessible close to the door - lock must be
  lubricated and easy to operate.                 78
          Fixed CO2 Systems
 Quarterly inspection to check: -
 All valves are clearly numbered and corresponding to
  operating instructions; &
 Alarms tested in the spaces being protected. Alarms must
  be tested in an organized manner, with warnings issued to
  advise all personnel - combine test with E/Room fire drill
  for onboard training; &

 Every 6 months - fixed piping is to be “blown through”
  with compressed air. Visual inspection must be made to
  ensure that all fixed piping is clear and free from blockage
  or damage. Follow maker’s instructions.
                                                          79
3.9 - Fixed Foam Systems
 SOLAS II-2, Reg 8, 9, 21 & 61; CDI SIR 9.47 - 9.54;
 OCIMF VIQ 5.9.10;

 Provided for E/Room, Boiler Room, Cargo Pump Room,
  Main Deck or a combination of any or all of these areas;
 Quarterly inspection to check that: -
 All valves, hydrants, nozzles, etc are located and
  maintained as per previous instructions;
 Nozzles are clean and free from obstruction; &
 Foam pumps/metering pumps are tested - can be part of a
  Manifold Fire Drill, used as a Foam System demonstration
  for applicable crew members.
                                                         80
       Foam Sample Analysis


 A sample of the foam concentrate is to be sent ashore for
  analysis ANNUALLY; &

 Certificate of this test must be maintained in the SRF.




                                                            81
   3.10 - Fixed Halon Systems
 SOLAS II-2, Reg 5.3 & 21; CDI SIR 9.33 - 9.35;
 OCIMF VIQ 5.9.10;

 Provided for E/Room, Cargo Pump Room and Cargo Spaces
  intended solely for carriage of vehicles which are not
  carrying any cargo;
 Quarterly inspection to check that: -
 All cylinders and activation mechanisms are in good
  condition - follow maker’s instructions; &
 Alarms tested in the spaces being protected. Alarms must
  be tested in an organized manner, with warnings issued to
  advise all personnel - combine test with fire drill for
  onboard training.
                                                        82
         3.11 - Cargo Hold
         Sprinkler Systems
 SOLAS II-2, Reg 21 & 53;
 Quarterly inspection to check that: -
 Hose couplings and valves are lubricated and in
  satisfactory condition;
 Each time a cargo hold is empty, make a visual inspection
  of the sprinkler nozzles; &

 Test the system ANNUALLY whilst the holds are empty -
  incorporate the test into a fire drill and use for crew
  training/familiarization.

                                                        83
3.12 - Deck Water Spray Systems
        SOLAS II-2, Reg 21 & 54 Section
         2.1.3; CDI SIR 9.60 - 9.64; &
         OCIMF VIQ 16.15.1
        Quarterly inspection to check that
         pipelines, couplings, valves and
         spray heads are secure and in good
         condition;
        Lubricate as necessary; &
        Ensure that activation points are
         clearly marked.

        Test the system at EACH DRILL
         and verify that spray heads are free
         from obstruction- use for crew
         training/familiarization.
                                                84
       3.13 - Fireman’s Outfits
 SOLAS II-2, Reg 17 & 21;
 CDI SIR 9.8 - 9.14;
 OCIMF VIQ 5.9.6;

Location must be clearly marked by SOLAS
   label!

 Consists of: -
 Suit of Protective Clothing;
 Boots & Gloves;
 A rigid helmet;
 Safety Lamp;
 An Axe with insulated handle;
 Fireproof line; &
 Self Contained Breathing Apparatus.
                                           85
            Fireman’s Outfits
Monthly inspections must include:
 Inspection of all pieces of equipment to ensure that
  outfits are ready for immediate use;
 Safety lamp - test for brightness, replace batteries as
  required;
 BA Set - inspection of mask (faceplate and rubber
  material), securing straps, harness and waistband,
  demand valve and low pressure whistle are to be tested
  and satisfactory;
 If any problems are discovered, BA set is to be
  immediately removed from service until repairs are
  completed.                                                86
                Fireman’s Outfits

 BA sets should be stored in
  two widely separate locations,
  each location must be clearly marked;

 Individual units must be stored in readily accessible
  condition to enable any user to “don” the set in
  minimum time;
 BA set inspection including verification of all cylinder
  pressures (in use & spares); &
 Each BA cylinder must have been pressure tested within
  the last 6 years - date stamped on neck of bottle and
  recorded in SRF.

                                                             87
         Fireman’s Outfits
 All BA cylinders must be
  numbered, individual
  pressures recorded and
  any alarming reduction
  in pressure must be
  considered as leakage
  and cylinder sent ashore
  for repair; &
 Leaking cylinders must
  stored away from spare
  cylinders for use and
  marked accordingly.

                             88
            3.14 - Paint Locker
           Extinguishing System
 SOLAS II-2, Reg 18.7 & 21;
  CDI SIR 9.67; OCIMF VIQ
 Activation Valve must be clearly
  marked;
 Quarterly inspection of operating
  valve - ensure lubricated and free to
  turn;
 Inspect internal sprinkler heads,
  ensure they are not blocked.
 For fixed gas type - activation alarm
  must also be tested.
                                          89
3.15 - Portable Foam
     Applicator
 SOLAS II-2, Reg 6.4 & 21;
  CDI SIR 9.36; OCIMF VIQ 5.9.5;

 Consists of: -
 Portable tank containing 20 litre of
  foam making liquid;
 Fire Hose;
 Air-Foam nozzle, inductor type; &
 One spare 20 litre tank.


                                         90
Portable Foam Applicator
   Inspect MONTHLY to verify that: -
   All parts are complete and in good
    condition;
   Check hose for heat degeneration, &
    that coupling rubber seals and bindings
    are not damaged; &
   Foam liquid containers are full.

   Pressure test fire hose ANNUALLY as
    per section 3.2;

   Foam making liquid will have an expiry
    date - ensure that it is marked on each
    container and in the SRF.
                                              91
     3.16 - International Shore
             Connection
 SOLAS II-2, Reg 19 & 21;
 CDI SIR 9.30 - 9.31;
 OCIMF VIQ 5.9.9;

 This equipment must NEVER
  be used for routine ship’s
  activities or connecting to
  shore based water supply
  during repair periods;

 It is supplied SOLELY to
  connect the shore based
  emergency services to the
  ship’s fire main.
                                  92
International Shore Connection

       Inspected MONTHLY to
        ensure that: -
       Rubber seal is in good
        condition and fitted correctly;
       Connection is complete,
        including gasket, nuts, bolts
        and washers; &
       Properly secured in its
        designated place with clearly
        identifiable markings.


                                          93
         3.17 - Fire Control Plans
 SOLAS II-2, Reg 20 & 21; CDI SIR 9.1 - 9.7; OCIMF 5.1.8;
 Fire Control Plan must be posted within the accommodation
  detailing the location of all fire fighting appliances and other
  fire control measures;
 IMO standard symbols must be used to identify the various
  pieces of equipment;
 Additionally, all instructions concerning maintenance and
  operation of all firefighting equipment are to be kept under
  ONE cover, readily available and in an accessible position;
 The SRF is the ideal place to keep operation and maintenance
  instructions - if upon inclusion of maker’s instructions the
  folder is too bulky - it can be split into different sections in
  different folders.
                                                               94
              Fire Control Plans
 ISGOTT 4.7;
 A duplicate plan is to be stored in a
  watertight container, located outside of
  the accommodation for assistance of the
  shorebased fire fighting personnel;

 Container should include: -
 General Arrangement Plan indicating
  location of all fire fighting appliances and
  other fire control measures;
 Copy of the present load/discharge plan
  including stability information; &
 A copy of the very latest crewlist.

                                                 95
             Fire Control Plans

 Ensure that container is inspected
  MONTHLY to ensure that: -
 Contents are dry and in good readable
  condition;
 Open/Close arrangements are free and
  easy to operate - lubricate if necessary; &
 Ensure that information is maintained up
  to date at all times - each time info is
  updated, it must be recorded in the SRF.




                                                96
Take a break, before you carry on! 10 minutes.




                                            97
  Section 4 - Miscellaneous
            Items
 General Alarm System;
 Fixed Fire Detection System;
 Cargo Hold Smoke/Fire Detection
  System;
 Fixed Sensor Gas Detection
  System;
 Remote Trips/Shut Offs
 Lifeboat Engine;
 Emergency Power Supplies;
 Fire Pumps; &
 Watertight & Fire
  Doors/Emergency Escapes.
                                    98
  Section 4 - Miscellaneous
            Items
 Breathing Air Compressor;
 Oxygen Resuscitation Equipment;
 Vents/Fire Dampers;
 Gas Tanker Additional Rqmnts;
 Chemical Tanker Additional
  Requirements;
 Signaling Lamp;
 Safety Training Videos;
 Personal Protective Equipment; &
 Miscellaneous Alarms.

                                     99
    4.1 - General Alarm System
 SOLAS II-2, Reg 13 & 21;
  CDI SIR 9.45 - 9.46; OCIMF 5.11;
 If possible, General Alarm activation
  points must be tested on a rotation
  basis;
 The general alarm should be
  activated from a different location at
  each drill;
 The SRF record should state which
  activation point was tested;
 The alarm bells or sirens must also
  be inspected and it must be
  confirmed that each unit is in good
  working order.
                                           100
   4.2 - Fixed Fire Detection
             System
 SOLAS II-2, Reg 13, 14 & 21;
  CDI 9.43 - 9.44; OCIMF 5.11.1;

 Weekly, one detector head/sensor from each zone is to
  be tested;
 Ensure that within 3 months, ALL detectors/sensors in
  the entire system have been tested;
 C/O & C/E to draw up a plan and designate person(s)
  responsible for carrying out tests;
 Each weekly test need not be recorded - only the
  completion of the system test schedule & system
  maintenance need be recorded in the SRF.              101
       4.3 - Cargo Hold Smoke/
        Fire Detection System

 SOLAS II-2, Reg 53;

 System is to be tested on a monthly
  basis and must be continuously
  running when cargo is being carried
  in the holds;

 For routine maintenance - refer to
  maker’s instructions; &

 Open ended detector lines must be
  blown through with compressed air
  once every 6 months.

                                        102
      4.4 - Fixed Sensor Gas
        Detection System
 SOLAS II-2, Reg 13-1, ISGOTT 7.8, 8.2, 18.5 & OCIMF
  VIQ 5.12;

 Usually fitted on tankers and maybe of the combustible
  element or infra red type;
 The equipment must be in operation at all times whilst
  the vessel is in service;
 For full system maintenance, refer to maker’s
  instructions; &
 It is not necessary to record the zero and span test
  results in the SRF, these should be recorded on HSC
  Form 70 - Calibration Records.
                                                           103
Fixed Sensor Gas Detection System


  Zeroing & Spanning of the system must be carried out
   as per the following schedule: -

  Zero Test - Mechanical   Weekly
  Zero Test - Nitrogen     Daily
  Span Test                Weekly & prior to commencing
                            cargo operations.




                                                          104
4.5 - Remote Trips/Shut Offs

       Maybe electrically,
        mechanically, pneumatically or
        hydraulically activated;
       ALL remote trips and shut off
        devices are to be tested on a
        QUARTERLY basis;
       Testing must be carefully
        planned and with the full
        knowledge and agreement of
        all parties concerned; &
       For further details, refer to
        maker’s instructions.

                                         105
Remote Trips/Shut Offs

    Entries into the SRF are only
     required to show the actual
     date that any inspection or
     maintenance work was carried
     out;
    The actual result of testing
     each individual trip or shut off
     must be recorded elsewhere,
     i.e. cargo log book, engine log
     book or QMS forms.


                                        106
           4.6 Lifeboat Engines
   SOLAS III, Reg 20.6
   CDI Section 10, item 20;
   OCIMF VIQ 5.16.1;
 Lifeboat engine operating instructions are
  to be legible and mounted in a
  conspicuous place;
 Weekly run engine(s) for 10 minutes
  and test engaging of gear box unless
  operation without the propeller
  submerged will cause damage - in which
  case refer to maker’s instructions.
 CDI 10.29 - Ensure that batteries &
  battery charging system are in good
  condition.
                                               107
               Lifeboat Engines

 An engineer must conduct a
  thorough inspection of the
  lifeboat engines, reversing gear
  etc on a MONTHLY basis;
 Routine maintenance as per
  maker’s instructions must also
  be carried out at this time; &
 This is to include checks on oil
  and fuel levels.

 SRF records must be in detail, all
  tests and maintenance carried
  out on the lifeboat engines.
                                       108
            Testing in the Water

   SOLAS III, Reg 19, 3.3.3; CDI 10.30/31; OCIMF 5.17.1;
   Davit Launched lifeboat shall be launched and
    manoeuvred in the water at least once every 3 months
    during an abandon ship drill;
   SOLAS III, Reg 19, 3.3.4;
   Free Fall lifeboat can be lowered into the water every 3
    months, provided that it is free fall launched once every
    6 months
   The Fire Protection System is to be tested when any
    lifeboat is waterborne; &
   Records of each launching must be recorded in the SRF
    Section 5.4.
                                                           109
      4.7 - Emergency Power
             Supplies
 SOLAS II-1 Part D, Reg 43;
  OCIMF VIQ 12.6.2 - 12.6.5;
 The emergency source of electrical
  power (generator or batteries) is
  to be tested on a weekly basis; &
 Weekly checks must also include
  oil levels and verification that the
  fuel tank is full.

 Emergency generator maintenance
  must be carried out as per maker’s
  instructions and details recorded in
  the SRF.
                                         110
              4.8 - Fire Pumps
 SOLAS II-2 Reg 4; CDI SIR 9.18 - 9.22;
  OCIMF VIQ 5.9.2;
 The main and emergency fire pumps are
  to be test run on a weekly basis; &
 Test must ensure that 2 jets of water
  can be maintained, one from the bridge
  wing and one from the foc’sle;
 All valves must be clearly labeled and
  correspond to the posted starting
  instructions.
 Fire Pump maintenance must be carried
  out as per maker’s instructions and
  details recorded in the SRF.             111
4.9 - Watertight Doors/Fire
Doors/Emergency Escapes
   SOLAS II-1 Reg 24;
   All watertight doors, fire doors &
    emergency escapes must be kept clear
    of obstructions at all times;
   Watertight doors are to be tested on a
    weekly basis from both remote and
    local operating positions; &
   Internal fire doors must be inspected
    and tested to ensure they close
    properly including doors that are held
    open magnetically.
   All dates of testing, and details of
    maintenance done must be recorded.
                                             112
    4.10 - Breathing Apparatus
            Compressor

 CDI SIR 9.15 - 9.17;
  OCIMF 15.13.3 & 16.14.2;
 A log of the running hours is
  to be maintained at the
  compressor;
 For maintenance - refer to
  maker’s manual; &

 Details of equipment
  maintenance and servicing
  are to be recorded in the SRF.


                                   113
4.11 - Oxygen Resuscitation
        Equipment
     OCIMF VIQ 5.16.7;
     Inspect unit monthly;
     Verify that cylinders in use and
      spares are full and that empty
      bottles are re-charged ashore as
      soon as possible; &
     Ensure that all required
      components are kept within the
      unit and the unit is maintained in
      a clean and hygienic condition.
     Details of recharging or unit
      maintenance must be recorded in
      the SRF.
                                           114
4.12 - Vents & Fire Flaps
  OCIMF VIQ 5.10 - All vents, flaps and
   dampers etc are to be regularly inspected
   and operated - a good routine must be
   established to ensure none are omitted;
  They must be greased/lubricated, rubber
   seals inspected & replaced as necessary;
  All dogs, clips, operating handles, wires,
   etc are to be well maintained;
  Open & Closed markings must be clearly
   visible as an indicator to identify which
   position the vent is in; &
  Vent type doors must be kept free of
   obstructions.                                115
  4.13 - Gas Tanker
Additional Requirements
   OCIMF VIQ Chapter 16;
   Contained in IMO publication “Code
    for the Construction & Equipment
    of Ships Carrying Liquefied Gases
    in Bulk”;
   Additional requirements include
    fireman’s outfits, gas masks,
    escape sets, showers and eye
    washes, deck water spray systems
    and ESD’s etc; &
   Actual requirements depend upon
    ship type, age of vessel & cargoes
    carried - consult the Code.
                                         116
         Gas Tanker Additional
            Requirements
 The SRF must contain details of
  all additional equipment carried
  or fitted;
 It’s location and activation point
  (if relevant); &
 Details of maintenance and test
  must also be recorded in the
  SRF; &
 Under the IGC Code - PPE and
  BA sets are to tested by an
  expert annually.
                                       117
  4.14 - Chemical Tanker
  Additional Requirements
 OCIMF VIQ Chapter 15;
 For ships built before 01 July 1986, contained in
  IMO publication “Code for the Construction &
  Equipment of Ships Carrying Dangerous Chemicals
  in Bulk - BCH Code)”; or

 For ships built after 01 July 1986, contained in IMO
  publication “International Code for the
  Construction & Equipment of Ships Carrying
  Dangerous Chemicals in Bulk - IBC Code)”.

                                                    118
        Chemical Tanker Additional
             Requirements
 Additional requirements include fireman’s
  outfits, gas masks, escape sets, showers and
  eye washes, deck water spray systems and
  ESD’s etc; &
 Actual requirements depend upon ship type,
  age of vessel & cargoes carried - consult the
  applicable Code;
 The SRF must contain details of all additional
  equipment carried or fitted;
 It’s location and activation point (if relevant);
 Under the IBC Code - PPE and BA sets are to
  tested by an expert annually. &
 Details of maintenance and test must also be
  recorded in the SRF.
                                                      119
4.15 - Signalling Lamp

   SOLAS V, Reg 11; OCIMF 4.1.10;

   Must be available for use at all
    times;

   Monthly, inspect the casing and
    electrical connections for condition
    and tightness;

   Ensure that a spare bulb is always
    available.



                                           120
      4.16 - Safety Training
              Videos
 HSC has a rental contract with
  Videotel to place 12 training
  videos on board. Additional 12
  Waalport training videos are
  supplied!
 Additionally videos maybe
  placed permanently onboard by
  HSC - these are normally topic
  specific and remain the property
  of HSC; &
 The SRF must list any titles
  permanently carried onboard.

                                     121
  4.17 - Personal Protective
          Equipment
 An up to date inventory must
  be maintained for all
  equipment carried;
 Certain items must be
  available to all personnel i.e.
  safety helmets, therefore the
  SRF inventory should only
  indicate items in excess of
  this requirement; &
 Master & Safety Committee
  must decide on the minimum
  stock to be carried.

                                    122
   Personal Protective Equipment

 The SRF contains a detailed list of the
  PPE that is mandatory and
  recommended for use when working
  onboard - Master & Safety Committee
  must refer to this when making up list of
  minimum stock;
 OCIMF VIQ 5.1.10 - Inspection of PPE
  and inventory list must be updated
  QUARTERLY and requisitions submitted
  (every 4 months) to replenish
  diminished stock;
 Condition should be reported as new,
  used or poor.
                                              123
     4.18 - Miscellaneous Alarms
 Used to identify alarms onboard
  that are not covered elsewhere in
  the testing program;
 i.e. Provision Room Alarm or
  Hospital Alarm; Dead Man Alarm
 Once identified, additional alarms
  must be added to the list
  provided - their frequency of test
  & department or rank responsible
  for testing must also be indicated;
  &
 Dates of each test must also be
  maintained in the SRF.
                                        124
      Section 5 - Records of
       Drills & Inspections

 Weekly SOLAS inspections;
 Monthly SOLAS inspections;
 Emergency Situation Drill
  Program;
 Record of Emergency Drills;
 Emergency Steering Drills; &
 Oil Spill & Pollution Drills.


                                  125
 5.1 - Weekly SOLAS Inspection

 SOLAS III, Reg 20.6;
  CDI SIR 10.97;
 Following tests & inspections must be carried out: -
 All survival craft, rescue boats and launching appliances to
  ensure they are ready for use;
 Lifeboat engine(s) run as per SRF 4.6;
 The General Alarm must be tested as per SRF 4.1; &

 This is only a record of the inspection - details of any
  maintenance or testing carried out on SOLAS
  equipment, MUST be recorded under sections 2, 3 or 4
  of the SRF.
                                                            126
5.2 - Monthly SOLAS Inspection

 SOLAS III, Reg 20.7;
  CDI SIR 10.98;
 Following tests & inspections must be carried out: -
 All Life Saving Appliances including lifeboat equipment;
 Refer to HSC Form 67 A/B to assist with this inspection; &

 This is only a record of the inspection - details of any
  maintenance or testing carried out on SOLAS
  equipment, MUST be recorded under sections 2, 3 or
  4 of the SRF.


                                                         127
 5.3 - Emergency Situation Drill
           Program
 ISM Code Section 8.2;
 HSC requires that a drill covering at
  least one of the emergency situations
  shown in this section of the SRF is
  conducted each month;
 This must be in addition to drills
  specified elsewhere;
 Senior Officers are to make maximum
  use of the OPCP Manual when planning
  & preparing drill scenarios; &
 Drill analysis including
  recommendations must be forwarded
  to HSC QMS Dept.
                                          128
5.4 - Record of Emergency Drills


 SOLAS III, Reg 19;
 A record of every emergency drill
  carried out onboard is to be
  retained on board;
 Date, Time and Type of Drill in
  the Deck Logbook; &
 Full details (date, description of
  drill & outcome of drill etc) to be
  recorded in the SRF 5.4.

                                        129
5.5 - Emergency Steering Drills

 SOLAS V, Reg 19-2;
 To be carried out at intervals
  not exceeding 3 months;
 In Deck Logbook record date,
  time and type of drill;
 Full Details of Emergency
  Steering Drill (persons
  involved, situations simulated,
  outcome, etc) to be recorded
  in SRF section 5.5.

                                    130
  5.6 - Oil Spill & Pollution Drills

 Drills should also include
  familiarization with garbage
  disposal, sewage and atmospheric
  pollution regulations and related
  HSC procedures and instructions;
 Senior Officers should refer to the
  OPCP Manual & SOPEP and/or
  VRP when planning such drills;
 Drills should be varied and
  involve as many crewmembers as
  possible.

                                        131
       Oil Spill & Pollution Drills


 A record of all oil spill and pollution
  drills carried out onboard are to be
  retained on board;
 Date & Type of drill must be
  recorded in the Deck Logbook and
  SOPEP;
 Full details, persons involved,
  outcome of drill, etc are to be
  recorded in the SRF 5.6.


                                            132
                 Drill Plan
Drills are carried out in accordance with

• SOLAS requirements
• ISM Code requirements
• company requirements

It is recommended

• to vary scenarios
• to interchange roles of crew member
• to repeat drills if unsatisfactory carried out

                                                   133
End of course – Safety(maintenance)

         The final session has now been
         completed!
         Now you have had an review on different
         requirements on the maintenance of your safety
         equipment on board!

         If there is any open or unanswered question,
         please consult SOLAS or contact your agency
         instructor.
         With the knowledge you have now, please take
         the questionnaire and check on all questions
         again!

                                                134
                 Finally


We hope you will find this course useful and the content
will help you to prepare for the next forthcoming audit!
If you have any comments please write them down and
   send them to the HSC Crew Operation Manager!
 Thanks for participating and we wish you always safe
                       sailings!