MINI-TIMER TO LIGHTS AND APPLIANCES ON command in the evening followed by an

OFF command some time late at night or early

Automatic timed events are possible from AM. You may not want the lights to burn all

a simple desk top “alarm-clock-looking” plug- night, so you could program an OFF com-

in device called the PHT02 Mini-Timer. mand sometime around your bedtime, and a

second ON command in the morning (for early

risers) followed by an OFF sometime around

Dawn.

No more than 2 ON and OFF times can

be programmed under a rocker on the Mini-

Timer at a time, else an error 18:88 (see pro-

gramming manual in last section) appears on

the screen warning you that there already ex-

ists a second command for that Unit Code.

At the time of programming, the Security

Decoratively styled and equipped with a button can be pressed to cause the ON/OFF

buzzer, the PHT02 is capable of being a wake times to be varied, otherwise they will occur

up alarm clock. Additionally it can turn ON a exactly at the same time every 24 hours.

single X10 Receiver concurrent with the

buzzer to aid in waking you up. You can also program a Unit Code for an

The top of the Controller has several rock- XPS2, 240V 20A Wall Switch to run a Pool/

ers and buttons for operation, and also has Spa filter pump every day for a few hours while

on-board memory to program and store up to you are not at home.

2 ONs and 2 OFFs for up to 4 X10 Unit Code At any time you may manually press any

addresses. of the Unit Code rockers to send an ON/OFF,

A selector switch allows sequence 1-4 or BRIGHTEN/DIM or ALL LIGHTS ON/ALL

5-8 to be the Unit Codes controlled. A House UNITS OFF command.

Code selector wheel on the control panel al- Requires a 9V battery for memory backup

lows you to set the X10 House in case of power failure.

Code that matches the installed FEED FROM

STREET TRANSFORMER



Receivers.

MAIN DISCONNECT



Flexible control program- NEUTRAL BAR



PHASE A

PHASE B

120VAC



ming; the Mini-Timer can be pro- 120VAC

FEEDS TO

OUTLETS

FEEDS TO

OUTLETS

AND

AND SWITCHES

grammed to vary the ON/OFF SWITCHES







times daily to not look like a timed

automatic function. This is a EARTH GROUND

ELECTRICAL PANEL

great deterrent to would-be bur-

glars who are watching your

home.

The Mini-Timer can be pro- 13

1





9

5 M

A





I

E









grammed to turn on a Wall OFF ON









Switch that operates the lighting N F

O O F





M





1

A



I

E





9

13

M

A





I

1





9

E









5









around your outside walkways.

Simply set the Wall Switch

(ie. XPS3 Decorative 20A Wall

Switch) to match one of the pos-

sible 1-4 or 5-8 Unit Codes.

Program the Timer for an





83 C Rev 5/2001

APPLICATIONS

SEVEN DAY TIMER WALL CONTROLLER

Lets say you own a horse ranch and ev-

Similar in function, but very different in ery day you have an electrified fence turn on

design from the Mini-Timer, the XPPC ex- while you are at work. But on Saturdays you

pands on the ability to control timed events are home and want the fence to be off. Simply

(up to 63 events) and spreads them out over program the XPPC to control a PAM02 (3-Pin

a seven day period rather than every 24 hours; Appliance Module to run the transformer for

plus spans all the X10 House Codes rather the fence). Have it run a Mon-Fri routine and

than having to select only one (A-P). leave it off on Saturdays until around Dusk.

Then, on Sundays you can have it turn ON

while you are away in the morning, and OFF

around the time you arrive back home. The

seven day programming allows you the flex-

ibility that you need for such an operation.

Lets not forget Holidays when all the rela-

tives and their children come to visit, simply

program the XPPC to “Holiday Mode” for one

day during the coming week and the Control-

ler will skip routines for that day.







FEED FROM

STREET TRANSFORMER

The programming is

done through an LCD NEUTRAL BAR

MAIN DISCONNECT



front display and uses PHASE A

PHASE B

120VAC

step by step forward and 120VAC

FEEDS TO

FEEDS TO

OUTLETS

OUTLETS AND

back buttons to select AND

SWITCHES

SWITCHES



between Day, Time,

House Code, Unit Code

and X10 Command to

EARTH GROUND

perform. ELECTRICAL PANEL

The XPPC has a

unique Holiday feature

that allows you to skip a

specific program for a cer-

tain day in every week. 1 A

13 5 M E









This allows you to be in

9 I









control of manual func- OFF ON









tions when home for a O O





M





1

N F

F

A



I

E





9

M







13

A



I

1





9

E









5









Holiday, rather than the

scheduled timed func-

tions.

A program could be

run weekly for lighting, ir-

Hot

rigation and common ap-

pliance control eliminating Neutral





tedious manual tasks.





84 C Rev 5/2001



Related docs
Other docs by yurtgc548
The Universe
Views: 0  |  Downloads: 0
The Universe of Planet Ziggy
Views: 0  |  Downloads: 0
The Universe Galaxies_ Stars_ and Nebulae
Views: 0  |  Downloads: 0
The United Nations MDG Strategy
Views: 0  |  Downloads: 0
The United Kingdom
Views: 0  |  Downloads: 0
The Uniqueness of Jesus
Views: 0  |  Downloads: 0
The Union In Peril
Views: 0  |  Downloads: 0
The Underground Railroad
Views: 0  |  Downloads: 0
By registering with docstoc.com you agree to our
privacy policy

You are almost ready to download!

You are almost ready to download!