PULSE TRANSFORMERS

TRANSFORMER EQUIVALENT CIRCUIT:



The influences of a transformer’s parameters can best be understood by considering the equivalent

circuit in below.

This ciruit shows a typical output pulse waveform. Assuming that this output pulse is the result of

injecting an ideal rectangular input pulse, one can see that a number of parameters are distorted.

Overshoot, droop, back swing, rise time, etc. appear as unwanted signal distortion on the output pulse.

Assuming the pulse transformer is properly matched and the source is delivering an ideal rectangular

pulse, the transformer should have low values of leakage inductance and distributed capacitance while

having a high open circuit inductance. This will limit the deterioration of the pulse shape. Also, the fact

that the source will never produce an ideal rectangular pulse adds to the problems of distortion.





& 36

/3 / 6

6285&( 5! 5$

5J L

S LV

&3 5& &6 5/

(J /! /$



1 31 6



Transformer Equivalent Circuit.



Where:

Rg = Internal resistance of the driving source.

Eg = Open circuit source voltage.

RP = DC Resistance of the primary winding.

RS = DC Resistance of the secondary winding.

RL = Load Resistance on the secondary winding.

RC = Core losses expressed as a shunt resistance in parallel with the primary windings.

CP = Primary shunt and distributed capacitance.

CS = Secondary shunt and distributed capacitance.

CPS = Primary-to-Secondary capacitance (inter-winding capacitance).

LP = Primary inductance that is mutually coupled to the secondary.

LS = Secondary inductance that is mutually coupled to the primary.

LP1 = Primary inductance that does not link the secondary (Primary leakage inductance).

LS1 = Secondary inductance that does not link the primary (Secondary leakage inductance).

iP = Current in the primary turns.

iS = Current in the secondary turns.

NP = Number of turns on the primary.

NS = Number of turns on the secondary.









Specifications subject to change without notice.

Rhombus 8

15801 Chemical Lane, Huntington Beach, CA 92649-1595

Industries Inc. Tel: (714) 898-0960 • Fax: (714) 896-0971



Related docs
Other docs by mardisana nama...
circuit
Views: 1  |  Downloads: 0
0qk1k6oc02kyzqy3gjdzc9laf2cy
Views: 0  |  Downloads: 0
nte5661
Views: 0  |  Downloads: 0
01_trigg
Views: 0  |  Downloads: 0
e22229322
Views: 0  |  Downloads: 0
mXyzyvq
Views: 0  |  Downloads: 0
dbt139f-600_ul_
Views: 0  |  Downloads: 0
pg20
Views: 0  |  Downloads: 0
transformer isolated gate drive
Views: 8  |  Downloads: 1
By registering with docstoc.com you agree to our
privacy policy

You are almost ready to download!

You are almost ready to download!