Embed
Email

canopy ice shield divider

Document Sample

Shared by: dfgh4bnmu
Categories
Tags
Stats
views:
32
posted:
10/27/2011
language:
English
pages:
124
L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









7777 Hollister

W. Little York

Hollister









W. Tidwell

290









Beltway 8

Sam Houston Parkway

Bingle









45

59

W. Little York

Hollister









Tidwell

Clay

290 43RD







610



10





10









59

610

45









7777 Hollister, Houston, Texas 77040 • Phone: 713.856.9696 • Fax: 713.856.9686 • 1.800.356.7746 • Email: info@mpvent.com • www.mpvent.com

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









VENTILATOR AND LOUVER SIZING PROGRAM





This program is designed to provide guideline calculations necessary to determine the

size and quantity of gravity ridge ventilators and wall intake louvers to ventilate a

building. In order to link to this program you will need Microsoft Excel. Turn all the

add-ins on for this program to function properly.









CLICK ON THE VENTILATOR ICON TO START THE PROGRAM









Enter the following information:



1. Enter (a) for Continuous Ridge Ventilators - or - (b) for Round Ventilators

2. Building Length

3. Building Width

4. Eave Height

5. Roof Pitch

6. Minutes per Air Change (Ex: 10 minutes = 6 Air Changes per Hour)

7. Throat Size of Ventilator

8. Temperature Differential

9. Wind Velocity





Contact Metallic Products for technical assistance.









7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: mpv@mpvent.com · www.mpvent.com

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









COMPANY PROFILE

Since its founding in 1962, Metallic Products Corp. has grown to become an industry leader in the field of design and

manufacturing of ridge vents, roof curbs, wall louvers and door canopies for the steel building industry.

Back in the early 60’s, most metal building manufacturers made their building components themselves — a process

which they found both costly and time consuming. Metallic Products’ founder, Roy Hairston, began with the idea that

through specialization, both higher quality and lower costs could be achieved. This allowed his customers to concentrate on

producing the items which were profitable to manufacture. Through the years, we have remained committed to these ideals

of higher quality and lower costs. And now, because of our dedicated commitment to service, our customers have helped us

attain heights never imagined by Mr. Hairston back in 1962.

By our implementation of Total Quality Management techniques in 1992, our customers have been able to enjoy

significantly lower costs and increased product quality with shortened lead times. We feel this increase in customer satisfaction

is based upon the quality of our workforce. Of our 66 employees, 18 have at least 10 years experience with the company.

This dedication and experience gives you the benefits of flexibility in getting both standard and custom-made products to

meet your high standards of price, quality and service.

For your reference, here is an up-to-date profile of Metallic Products...

Ownership: Daryl Wendt, President / CEO (50% owner) e-mail: daryl@mpvent.com

Mike Hairston, Vice President (50% owner) mikeh@mpvent.com

Key

Personnel: Coy Poret, Vice President of Operations coy@mpvent.com

Sam Gray, QHSE Manager / VP Mfg sam@mpvent.com

Paul Walton, VP of Finance paul@mpvent.com

Henry Anglés, National Accounts Manager hangles856@aol.com

Debbie Arnett, Major Accounts Manager info@mpvent.com

Gary Lawson, Sales / Customer Service gary@mpvent.com

Lisa Stockton, Sales / Customer Service lisa@mpvent.com

Pam Maldonado, Sales / Customer Service pam@mpvent.com

Mike Bischof, Purchasing Manager mikeb@mpvent.com

Kurt Nietz, Shipping / Receiving kurt@mpvent.com

Lauren Hillier, Administrative Assistant lauren@mpvent.com



Plant Size: Over 73,250-sq. ft. of manufacturing facilities and offices located in Houston, Texas.

Mission Statement

The entire Metallic Products organization will continue our commitment to our valued customers. Our purpose is to

provide you with the highest quality products along with the highest levels of service. We pledge to listen and respond to our

customer’s needs and to earn your continued business every day. We understand that suppliers and customers are partners

with common goals of quality and performance. We strive everyday to uphold our end of that partnership. Finally, we need

and appreciate your business to help us continue to grow and to satisfy all your metal building component needs.









7777 Hollister, Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









CONTINUOUS VENTILATORS …









…used on metal roofing systems roofs conform to MP’s high standards and specifications which have been

developed, tested and proven over many years. They provide an excellent value for the user.



Standard Size Bird Screen

9" throat and 12" throat— 10 foot sections. Other sizes Fully protected by 4 x 4 mesh galvanized hardware cloth.

available upon request. Low profile design can be used for Construction

single unit or continuous run installation with no disassem- Durable 26 gauge exterior combined with internal compo-

bly. nents of 24, 20 and 18 gauge die formed sheet metal and

Integral Dampers machined parts for long service life.

Easy-moving damper opens to any degree from fully open Finish

to completely closed. Pre-painted or galvalume is standard. Other materials and

Design finishes available upon request.

Aerodynamically proportioned to exclude weather — pro- Drainage Area

tects air passages and full outlet area. Continuous slot — bottom of both sides of windbands.







BUILDINGS MUST BREATHE!



Ventilators manufactured by Metallic Products are in accor- moisture problems, such as rust and deterioration of insulation or

dance with the highest design requirements and specifications. the damage to stored products.

25 years plus of experience in furnishing stationary, gravity- The Metallic Products’s ridge ventilator is a manufactured

flow, continuous ridge ventilators has proven their efficient in 10-foot lengths which can be installed as individual units or in

performance and lasting quality. continuous runs. Vents may be furnished with or without dampers

A properly engineered ventilation system using continuous to control the flow of air. Operation of dampers is standard by pull

ridge ventilators will control the movement of fresh air through chains (Please specify when ordering), multiple damper operation

the building removing hot, stale air and air contaminated by is available for up to 5 or more units.

manufacturing or production processes. Summer heat is released Ventilators are shipped with a 1:12 end cap and can be field

naturally through gravity ridge ventilators. During winter proper modified to accommodate up to a 6:12 roof pitch.

ventilation can assist in the control of condensation and other

7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com

CV-01 / Rev. 8/01

DIMENSIONS AND TECHNICAL DATA

B

BIRD SCREEN A

DIE-FORMED BAFFLE DIMENSIONS (In Inches)

RAIN SHIELD Throat* A B C D E

DAMPER 9 13 211⁄4 141⁄2 18 281⁄4

LIFTER ARM C *12 17 281⁄2 18 22 33

SADDLE STRAP

SHIPPING WEIGHTS

SIDE SKIRT

Standard

Size Boxed Pkg. Size

Crated

9" 124 lbs 209 lbs 1241⁄2" X 191⁄2" X 301⁄2"

THROAT

12" 148 lbs 218 lbs 1241⁄2" X 23" X 35"

D

E * Other sizes available upon request.









TURNBUCKLE PULL BAR END CAP OF VENT END CAP OF VENT END CAP OF VENT







POP RIVET END

CAP TO DRAIN

ASSEMBLY



PULL BAR CONNECTION: DRAIN AT MULTI- DRAIN AT CAP

UNIT SPLICE OF END VENT

Install turnbuckles between

STOVE BOLT adjacent pull bars. With the ROOF PANEL MAJOR RIB ROOF PANEL MAJOR RIB

dampers in the closed position, NOTE:

adjust turnbuckles starting at BREAK DRAIN ASSEMBLY TO

one end of the run. FOLLOW EXACT ROOF SLOPE.









RAIN SHIELD RAIN SHIELD

DAMPER DAMPER

END CAP END CAP









PIVOT BRACKET & LIFTER ARM

PIVOT BRACKET & SADDLE STRAP LIFTER ARM GUIDE ROD

SADDLE STRAP

PULL BAR GUIDE ROD PULL BAR SPRING

PULLEY AT FRAME OR WALL SPRING





CHAIN CATCH (OPT.)

CHAIN WITH HANDLE PULL CHAIN MUST BE

REMOVED FOR CONTINUOUS

PULL BAR IN CLOSED POSITION 2" TRAVEL OPTIONAL PULL CHAIN OPERATION RUN OPERATION

STANDARD CABLE OPERATION (SINGLE UNITS ONLY)

TO CLOSE DAMPER, PULL CABLE









Chain-operated damper utilizes a rugged sash chain through chain locking device. Damper is spring-loaded to open and can

be adjusted to any opening from fully open to fully closed. Optional operator packages for multiple units or wall operation are

available. (See below.)





PERFORMANCE DATA

Throat Size Vent Above Ground CFM COLUMN



10' 1323 LEVER

20' 1890 PIVOT

HANDLE

PLATE WELDED

CLAMP

9" 30' 2241 ANGLE TO COLUMN



40' 2511

EYEBOLT s ‘S’ HOOK



10' 1764 BOAT WINCH



20' 2520 GIRT



12" 30' 2988

40' 3348 FOR CONTINUOUS RUNS FOR CONTINUOUS RUNS

Assumes 10° Temperature differential and 5 mph wind speed UP TO 5 UNITS UP TO 10 UNITS





METALLIC PRODUCTS • Houston, Texas 77040

(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









9" CONTINUOUS VENTILATOR SPECIFICATIONS

Ventilators are of low profile design to provide gravity type ventilation.

Birdscreen is provided to prevent nesting and each unit contains flashing for either

single unit or continuous-run installation.



Each unit is 9" x 10' with a base ventilating capacity of 2700 CFM at 20°

temperature differential with a 25' stack height.



Exterior parts are 26GA. G90 galvanized, painted galvanized or galvalume.

ASTMA446.



Interior parts are all of G90 galvanized steel.



Substructure consists of 10GA. saddle straps with interior baffles of 24GA.

Pull bars and pivot brackets are of 20GA. Lifter arms and damper slides are of

18GA.



Manual operation is through activation of pull bar, which is attached to bell-

cranked type lifter arms connected to damper with teflon coated pins through

damper slides.



Dampers are spring loaded to remain in open position until pull bar is

operated and locked in the closed position. Dampers operate in vertical manner.



Birdscreen is 4x4 mesh galvanized hardware cloth.









7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com

CV-01.1 / Rev. 8/01

B

A









C









THROAT

D

E



DIMENSIONS (In Inches)



Throat A B C D E

4 61⁄4 121⁄2 9 10 18

9 13 211⁄4 141⁄2 18 281⁄4

12 17 281⁄2 18 22 33

18 263⁄4 455⁄8 305⁄8 30 49

24 331⁄2 57 383⁄8 361⁄8 581⁄8

36 471⁄2 811⁄4 535⁄8 55 831⁄2

SHIPPING WEIGHTS

Size Boxed Standard Crated Pkg. Size

9" 124 lbs 209 lbs 1241⁄2" X 191⁄2" X 301⁄2"

12" 148 lbs 218 lbs 1241⁄2" X 23" X 35"









DATE:

8/18/994/22/97

TITLE:

FLAT SKIRT

DIMENSIONS

APPLICATION

7777 Hollister Road PART:



Houston, TX 77040 RIDGE VENT

CONTINUOUS VENT

(713) 856-9696 • 1-800-356-7746

E-mail: info@mpvent.com VS-1

CV-04 / Rev. 00/00

CV-01.2 / Rev. 8/99

WELDED FRAME RIDGE VENTILATORS

B

E



SIDE

BIRD SCREEN

F

EXTERIOR FRAME D

RAIN SHIELD



J

M

INTERIOR FRAME

SADDLE STRAP C

G L









SKIRT

H









K









A (THROAT)

P N



NOTE: EXTERIOR AND INTERIOR FRAME MADE OF 1⁄8" X 1 1⁄2" X 1 1⁄2" ANGLE HOT-DIPPED GALVANIZED AFTER

WELDING. ALL OTHER PARTS MADE OF 22 GA. SHEET METAL, STANDARD WHITE OR GALVALUME.

WELDED FRAME VENTILATOR DIMENSIONS

A A/2 B C D E F G H J K L M N P WT.



15 71⁄2 39 261⁄2 8 223⁄4 113⁄8 113⁄8 97⁄8 5 61⁄2 71⁄2 167⁄8 8 25



18 9 455⁄8 305⁄8 105⁄8 263⁄4 133⁄8 133⁄8 11 57⁄8 81⁄4 9 185⁄8 91⁄2 30 275#



20 10 49 325⁄8 101⁄4 283⁄4 143⁄8 143⁄8 113⁄8 8 91⁄8 10 173⁄4 9 33



24 12 57 383⁄8 117⁄8 331⁄2 163⁄4 163⁄4 135⁄8 81⁄8 91⁄4 12 211⁄2 11 361⁄8 324#



30 15 701⁄8 459⁄16 143⁄8 41 201⁄2 201⁄2 14 91⁄2 115⁄8 16 265⁄8 113⁄8 491⁄4



36 18 811⁄4 535⁄8 167⁄8 471⁄2 233⁄4 233⁄4 191⁄2 123⁄8 121⁄2 18 261⁄2 141⁄4 55 428#



42 21 94 61 187⁄8 56 2613⁄16 265⁄16 221⁄2 141⁄2 139⁄16 21 311⁄4 165⁄8 62



48 24 106 657⁄8 191⁄4 671⁄4 271⁄4 271⁄4 267⁄8 167⁄8 135⁄16 24 341⁄8 201⁄8 671⁄2 550#



DATE:

4/22/97

9/20/99

TITLE:

Purlin Spacing = “P” Plus 3" Each Side FLAT SKIRT

DIMENSIONS

APPLICATION

7777 Hollister Road PART:



Houston, TX 77040 WELDED FRAME

RIDGE VENT

(713) 856-9696 • 1-800-356-7746 CONTINUOUS VENT

E-mail: info@mpvent.com

CV-04 / Rev. 00/00

CV-01.3 / Rev. 9/99

Table of Capacities for Continuous Ventilators









MP









CAPACITY:

To determine capacity per unit, multiply “Base Rating” by “Temperature-Height Factor”: CFM = Base x

Temperature-Height Factor

Based on fresh air intake area 11/2 times ventilator throat area. Assumes 5 mph wind speed.



Temperature-Height Factors

Temperature Difference Base Ratings

Height 5° 10° 15° 20° 25° 30° 35° 40° 45° Size C.F.M.

10' .37 .49 .58 .64 .70 .76 .81 .86 .95 4" 1200

15' .42 .60 .71 .80 .86 .92 .99 1.05 1.09 9" 2700

20' .53 .70 .81 .92 .99 1.07 1.14 1.22 1.26 12" 3600

25' .58 .77 .89 1.00 1.08 1.18 1.25 1.33 1.39 15" 4500

30' .63 .83 .97 1.08 1.17 1.28 1.36 1.45 1.50 18" 5400

35' .66 .87 1.02 1.14 1.24 1.35 1.44 1.51 1.58 24" 7200

40' .70 .93 1.08 1.22 1.30 1.41 1.50 1.61 1.68 30" 9000

45' .74 .96 1.12 1.28 1.38 1.48 1.59 1.68 1.75 36" 10800

50' .77 1.01 1.18 1.33 1.44 1.56 1.67 1.75 1.83 42" 12600

55' .80 1.06 1.23 1.39 1.50 1.64 1.72 1.83 1.92 48" 14400

60' .83 1.09 1.28 1.44 1.55 1.69 1.79 1.90 2.00

65' .85 1.12 1.32 1.48 1.61 1.74 1.85 1.97 2.06

70' .88 1.17 1.36 1.53 1.67 1.79 1.89 2.02 2.11

75' .90 1.19 1.39 1.57 1.69 1.83 1.96 2.06 2.17

80' .93 1.22 1.42 1.61 1.72 1.86 2.00 2.11 2.20



Height = vertical rise from inlets near floor to ventilator.

Temperature = estimated temperature difference between middle of air intake near the floor and ventilator with

dampers open.



CV-01.4 / Rev. 8/99

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









METALLIC PRODUCTS CONTINUOUS VENTILATOR

DESIGN EVALUATION AND CERTIFICATION



This is to certify that the construction of the Metallic Products 10ft. sections of ridge ventilators with 10

ga. Base Straps, 24 ga. Baffles, and 26 ga. Sides, Ends, Skirts and Dampers will withstand wind loads

of 100 MPH when adequately supported by the roof panel to which it is attached. Minimum required

attachment is No. 14 self tapping screw to the top of each major roof panel rib.



Wind load is determined in accordance with the MBMA Design Manual procedure. The following analysis

could be construed as Parts and Portions of the building structure, such as load supporting systems of

structural roof panels, purlins, bracing, and framing.



The typical installation procedure for vents is to fasten each side skirt to the roof panel with a minimum

of 1-#14 STS @ 12" o.c. (2 fasteners per linear foot of vent). Various Manufacturers test data has indicated

that the resistance of these fasteners exceeds the design values used by Metallic Products by a factor

in excess of 2 1/2 to 1. This design value is 50 lbs. pull out and 100 lbs. shear per fastener when installed

in 26 ga. galvanized panels of 50,000 psi minimum yield stress.



The probable extreme standard condition would be a roof with mean height of 60 ft. and a slope between

10 and 30 degrees (4/12 included).



1. Assume the clear distance at the ventilator between roof sheets to be 24" max. (This is probably

greater than would occur for a 12" throat vent.)



2. Assume total vent is in “Z” edge strip. Building would have to be at least 100 ft.wide and 25 ft.

high at the eave.



3. Velocity Pressure q = 30.4 PSF (100 MPH) (Table 5.2b in the MBMA Low Rise Building Systems

Manual)



4. Se @ Interior edge from figure 5.5c, with roof angle between 10 and 30 degrees = 2.1



5. Uplift Pressure = 30.4 x 2.1 = 63.84 PSF.



6. Reduce because it is due to wind = 63.84 x 3/4 = 47.88









7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com

CV-01.5/1 / Rev. 8/01

Page 2









METALLIC PRODUCTS CONTINUOUS VENTILATOR

DESIGN EVALUATION AND CERTIFICATION







12" Standard Throat Ventilator: The 24 inch ridge opening results in 2 x 47.88 = 95.76 lbs. per ft. uplift on

ventilator or 47.88 lbs per fastener which is less than the 50 lbs. per fastener design stress. The ventilator

is less than 2 ft. high resulting in a shear stress of less than 50 lbs./fastener from an equal horizontal wind

load.



The building design used to create this wind loading exceeds the dimensional parameters of most

standard buildings offered by Metal Building Manufacturers. The location of the vent at the very end of

the building ridge (within the “Z” edge strip) is not unusual when continuous vents are used for the full

building length. However, a more common arrangement is to place the vents, one in the center of each

bay or to begin the continous run, one ventilator back from the end wall peak.



Evaluation conducted by:_______________________________ May 7, 1997

John M. Reynolds, P.E.









CV-01.5/2 / Rev. 5/97

END CAP OF VENT END CAP OF VENT

POP RIVET END CAP TO

DRAIN AT END OF VENT DRAIN ASSEMBLY

DRAIN AT MULTI-UNIT

SPLICE (WEEP)

CAULK HERE ROOF PANEL MAJOR RIB

CAULK HERE



ROOF PANEL MAJOR RIB



NOTES:

NOTE: BE SURE WEEPS ARE LEFT OPEN

BREAK DRAIN ASSEMBLY TO FOLLOW FOR 5:12 AND UP ROOF PITCHES,

EXACT SLOPE OF ROOF THE TWO BOTTOM RIVETS MUST BE

REMOVED BEFORE END SKIRT MAY

BE PLACED ON VENT. REPLACE

RIVET WITH SCREW.

SIDE

RIDGE VENT FLASHING

SKIRT WITHOUT DIE-FORMED SKIRTS

FASTENER

DATE:

1/4/99

CLOSURE WITH SEALANT T&B TITLE: FLASHING

WITHOUT DIE-FORMED

7777 Hollister Road

SKIRTS

PART:



END VIEW Houston, TX 77040 CONTINUOUS VENT

(713) 856-9696 • 1-800-356-7746

E-mail: info@mpvent.com DRAWING #2

CV-01.6/ Rev. 03/00

END SKIRT DETAIL AND

CONTINUOUS VENTILATOR CONTINUOUS VENT SPLICE

DIE-FORMED SKIRT









CHANNEL SUPPORT







END CAP OF VENT END CAP OF VENT

CHANNEL

GUTTER

TAPE SEAL

ROOF PANEL

GUTTER SUPPORT









END OF VENT DETAIL





DATE:

4/22/97

TITLE:

DIE-FORMED

7777 Hollister Road

SKIRT APPLICATION

PART:



Houston, TX 77040 CONTINUOUS VENT

(713) 856-9696 • 1-800-356-7746

E-mail: info@mpvent.com VFSS-1

CV-01.7 / Rev. 03/00

CONTINUOUS VENTILATOR

FLAT SKIRT





CLOSURE (Not by MP)





END OF VENT DETAIL





END CAP OF VENT



POP RIVET END

CAP TO DRAIN

DRAIN AT END OF VENT ASSEMBLY







CLOSURE (Not by MP)

CAULK HERE ROOF PANEL

MAJOR RIB





END SKIRT DETAIL AND

END CAP OF VENT

CONTINUOUS VENT SPLICE



DRAIN AT MULTI-UNIT SPLICE



DATE:

4/22/97

FLAT SKIRT

TITLE:









7777 Hollister Road

APPLICATION

CAULK HERE ROOF PANEL PART:



MAJOR RIB Houston, TX 77040 CONTINUSOUS VENT

(713) 856-9696 • 1-800-356-7746

E-mail: info@mpvent.com

CV-01.8 / Rev. 03/00

BIRD SCREEN END CAP

DAMPER GUIDE ROD

BAFFLE PUNCH MARKS BLIND RIVETS (2) REQ’D



RAIN SHIELD FIELD CUT FOAM CLOSURE

DAMPER

END SKIRT

DAMPER SLIDE

LIFTER ARM

6:12 PEAK PANEL

5:12

4:12

SADDLE STRAP 3:12

PIVOT BRACKET 2:12





SKIRT

OPERATOR BAR

END CAP DETAIL ROOF PITCH LESS THAN 1:12 INSTALLATION:

THROAT NOTE: DOTTED LINE INDICATES

INSTALL END SKIRT FOR 1:12 ROOF SLOPE AND FOAM CLOSURE WITH

FIELD CUT FOR 6:12 ROOF TAPE SEALER TOP AND BOTTOM.

SLOPE. OTHER SLOPES

AS NOTED. ROOF PITCH GREATER THAN 5:12 INSTALLATION:

REMOVE TWO BOTTOM RIVETS BEFORE INSTALLING END SKIRT.

RAIN SHIELD REPLACE THE RIVETS WITH SHEETING SCREWS ONCE END SKIRT IS

DAMPER IN PLACE.

END CAP







PIVOT BRACKET & SADDLE STRAP LIFTER ARM

PULL BAR GUIDE ROD

PULLEY AT FRAME OR END WALL SPRING









PULL BAR IN CLOSED POSITION 2" TRAVEL PULL BAR CONNECTION

TO CLOSE DAMPER, PULL CABLE

STANDARD CABLE OPERATION DETAIL





RAIN SHIELD

DAMPER

END CAP









PIVOT BRACKET & LIFTER ARM

SADDLE STRAP GUIDE ROD

PULL BAR SPRING





DATE:

1/04/99

TITLE:

CHAIN CATCH (OPT.) INSTALLATION

CHAIN WITH HANDLE PULL CHAIN MUST BE

REMOVED FOR CONTINUOUS 7777 Hollister Road

DETAILS

OPTIONAL PULL CHAIN OPERATION RUN OPERATION

Houston, TX 77040

PART:

FLAT SKIRT

(SINGLE UNITS ONLY) (713) 856-9696 • 1-800-356-7746 CONTINUOUS VENT

E-mail: info@mpvent.com

CV-01.9 / Rev. 03/00

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









CONTINUOUS VENT OPERATORS

DRAWING VEW-1



DETAIL 3 - TYPE A OPERATOR #616

OPERATOR #624 - HAND PULL-CABLE 1 Lever Handle Mounting Hardware

35 ft. Plastic Coated Cable

2 Cable Clamps OPERATOR #619 - EXT.

I Chain Catch 50 ft. Cable

2 Pulleys 3 Eye Bolts

2 Cable Clamps

DETAIL 3 - TYPE B

OPERATOR #634A

OPERATOR #634 - HAND PULL-CHAIN

10 ft. Chain

35 ft. Chain

I Pulley

2 Pulleys

I Chain Catch

I Chain Catch



OPERATOR #634B

DETAIL 3 - TYPE C

4 ft. Chain

OPERATOR #618 - LEVER TYPE I Pulley

40 ft. Cable I Chain Hook

2 Pulleys

2 Cable Clamps

SINGLE UNIT OPERATOR FOR

I Lever Handle

Mounting & Installation Hardware MONOVENT

10 ft. Chain Installed

DETAIL 3 - TYPE D

OPERATOR #632 - BOAT WINCH TYPE

60 ft. Cable

2 Pulleys

I Boat Winch

Mounting & Installation Hardware









7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com

CV-01.10 / Rev. 8/01

DATE:

OCT. 1, 1983

TITLE:

OPERATOR A: 3/16" UNCOATED AIRCRAFT CABLE WITH CABLE KEEPER 3 UNITS MAX. END WALL

OPERATOR B: NO. 35 ZINC COATED SASH CHAIN WITH CHAIN KEEPER 3 UNITS MAX.

OPERATOR C: HAND LEVER TYPE 6 UNITS MAX.

7777 Hollister Road

INSTALLATION

PART:

OPERATOR D: BOAT WINCH TYPE 12 UNITS MAX.

Houston, TX 77040 CONTINUOUS VENT

(713) 856-9696 • 1-800-356-7746

E-mail: info@mpvent.com VEW-1

CV-01.11 / Rev. 10/83

DATE:

OCT. 1, 1983

OPERATOR A: 3/16" UNCOATED AIRCRAFT CABLE WITH CABLE KEEPER 2 UNITS MAX.

TITLE:

SIDE WALL

OPERATOR B: NO. 35 ZINC COATED SASH CHAIN WITH CHAIN KEEPER 2 UNITS MAX.

OPERATOR C: HAND LEVER TYPE 5 UNITS MAX. INSTALLATION

OPERATOR D: BOAT WINCH TYPE 10 UNITS MAX.

7777 Hollister Raod PART:



Houston, TX 77040 CONTINUOUS VENT

(713) 856-9696 • 1-800-356-7746

E-mail: info@mpvent.com VSW-1

CV-01.12 / Rev. 10/83

DATE:



TITLE:

WORM GEAR

7777 Hollister Road PART:

ASSEMBLY

Houston, TX 77040 CONTINUOUS VENT

(713) 856-9696 • 1-800-356-7746

E-mail: info@mpvent.com

CV-01.13 / Rev. 10/83

Hardwood Crating









60 – 9” x 10’ Vents Per Truck Load

(15 – 9” x 10’ Vents Per 10” of Trailer Space)



44 – 12” x 10’ Vents Per Truck Load

(11 –12” x 10’ Vents Per 10” of Trailer Space)



120 – 20” Round Vents with Peak Base Per Truck Load

(30 – 20” Round Vents Per 10” of Trailer Space)



48 – 20” Round Vents with Hillside Base Per Truck Load

(12 – 20” Round Vents Per 10” of Trailer Space)

Ridgeline Coravent









LOW PROFILE VENTILATORS









Prevent

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









LOW PROFILE FLOATING RIDGE VENT…

RIDGE LINE









...featuring Cor-A-Vent® ventilation core is designed specifically for architectural standing-seam retrofit applica-

tions and some residential applications where maximum ventilation is required in an attractive, very low-profile unit..



Standard Size Construction

Each ten-foot unit features 180 square inches of free area Unit is factory assembled and ready for installation. Vent

with a base rating of 450 CFM’s of air movement. Units in features the Cor-A-Vent® ventilation core — a time-tested,

lengths of other than ten feet can be manufactured upon economical, self-cleaning and durable core which has

request. Throat size is determined by roof pitch. been in service since 1970. All steel parts are 24 gauge.



Design Finish

Aerodynamic, low-profile design enhances the looks and Steel parts match roof type and color finish. All paint types

performance of architectural roof systems. The unit moves and colors are available including Kynar.® Please specify

toward the ridge on floating roofs. Vents are made to match roof system, paint system and color when ordering.

roof slope to maintain low-profile appearance.





BUILDINGS MUST BREATHE!

One of the most overlooked components of design and tions. 25 years plus of experience in furnishing stationary,

installation of architectural roofing systems, both in new con- gravity-flow, continuous ridge ventilators has proven their effi-

struction and retrofit applications, is ventilation. A properly cient performance and lasting quality.

engineered ventilation system using a continuous ridge vent in Lo-profile floating ridge vents are a low-profile, aestheti-

conjunction with an under soffit intake will provide proper fresh cally pleasing and extremely efficient means of ventilating

air movement through the roofing system removing hot, stale air. standing seam roofs. Each unit is manufactured in 10' lengths and

Summer heat is released naturally, extending both the life and can be installed as a single unit or can be butted together to form

performance of the roof. During winter proper ventilation can a continuous run. By lapping the furnished joint covers over the

assist in the control of condensation and other moisture problems top of the butted joints in a continuous run, the vent has the

such as rust and insulation deterioration. appearance of a single unit.

Ridge ventilators manufactured by Metallic Products are in When ordering please specify roof slope, roof system, paint

accordance with the highest design requirements and specifica- system, and color.



7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com

SV-01 / Rev. 2/01

DIMENSIONS AND TECHNICAL DATA









Ventilation Core









Floating Ridge Cap



Ventilation Core



Skirt

12 Existing Roof System

1⁄2" * ROOF SLOPE

3"

31⁄2"

SECTION A

Floating Ridge Cap

A 8 1⁄2"

Ventilation Core

5 1⁄2"

Skirt









2"

1"

11⁄8"

Existing Roof System

Closure Strip

THROAT * NOTE: Throat Varies with Roof Slope



TABLE A TABLE B

Air Movement per Lineal Foot Factors Wind Velocity Factors

HEIGHT Temperature Difference WIND Factors

IN FEET 5° 10° 15° 20° 25° 30° M.P.H. A B C D

10 16.65A 22.05A 26.10A 28.80A 31.50A 34.20A 3 1.14 1.09 1.05 1.02

15 18.90A 27.00A 31.95A 36.00A 38.70A 41.40B 5 1.25 1.18 1.13 1.09

20 23.85A 31.50A 36.45A 41.40A 44.50B 48.15B 7 1.41 1.29 1.22 1.16

25 26.10A 34.65A 40.05A 45.00B 48.60B 53.10C 9 1.62 1.43 1.33 1.25

30 28.35A 37.35A 43.65B 48.60B 52.65C 57.60C 11 1.82 1.57 1.43 1.32

35 29.70A 39.15B 45.90B 51.30B 55.80C 60.75C

40 31.50B 41.85B 48.60B 54.90C 58.50C 63.45C TOTAL CFM = (Table A) X (Table B) X Length

45 33.30B 43.20B 50.40B 57.60C 62.10C 66.60C

50 34.65B 45.45B 53.10C 59.85C 64.80C 70.20D TABLE C

Throat Size (Determined by Roof Pitch)

Pitch Throat Size Pitch Throat Size

Note: If material is furnished by customer, the following

1:12 61⁄2" 7:12 41⁄8"

must be supplied for each 10' section:

2:12 61⁄8" 8:12 31⁄2"

Painted Screws 3:12 55⁄8" 9:12 3"

1 Sheet for Metal Roof, 2 for Shingle 4:12 51⁄4" 10:12 21⁄2"

15 Self-Tapping Screws 1⁄4" x 11⁄2" 5:12 47⁄8" 11:12 21⁄8"

Type A W/Washers 6:12 45⁄8" 12:12 13⁄4"









METALLIC PRODUCTS • Houston, Texas 77040

(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746

NOTE:

NOTE: RIDGE VENT OPENINGS WILL REQUIRE

DO NOT CUT ANY SLOTS IN THE EXISTING SPECIAL ATTENTION TO AVOID

DECK ONE TRUSS BAY EITHER SIDE OF A INTERRUPTION OF ANY FIRE WALL

DRAFT BARRIER WALL. 8 1/ INTEGRITY

2"

THROAT VARIES WITH ROOF PITCH





FLOATING RIDGE CAP



VENTILATION CORE 2" 8 1/

2"





5 1/2

"

1 1/8

"



6"



2"



SHINGLES







CUT SLOTS STAGGERED

EACH SIDE OF RIDGE BEAM









7 1/2" MIN.









DATE:

10/12/98

TITLE:

1:12 TO 5:12

7777 Hollister Road

PITCH

PART:



Houston, TX 77040 SHINGLE TYPE

(713) 856-9696 • 1-800-356-7746 CORAVENT

E-mail: info@mpvent.com

SV-01.1 / Rev. 03/00

NOTE:

DO NOT CUT ANY SLOTS IN THE EXISTING NOTE:

DECK ONE TRUSS BAY EITHER SIDE OF A RIDGE VENT OPENING WILL REQUIRE

DRAFT BARRIER WALL. SPECIAL ATTENTION TO AVOID

INTERRUPTION OF ANY FIRE WALL

THROAT VARIES WITH ROOF PITCH INTEGRITY

10

1/2

"

FLOATING RIDGE CAP



VENTILATION CORE





2"

81

/2"







51

1 1/ /2"

8"



6"





2"







CUT SLOTS STAGGERED SHINGLES

EACH SIDE OF RIDGE BEAM









7 1/2" MIN.









DATE:

10/12/98

TITLE:

6:12 TO 12 :12

7777 Hollister Road

PITCH

PART:



Houston, TX 77040

SHINGLE TYPE

(713) 856-9696 • 1-800-356-7746 CORAVENT

E-mail: info@mpvent.com

SV-01.2 / Rev. 3/00

NOTE:

DO NOT CUT ANY SLOTS IN THE EXISTING

DECK ONE TRUSS BAY EITHER SIDE OF A

DRAFT BARRIER WALL.





10" NOTE:

RIDGE VENT OPENINGS WILL REQUIRE

SPECIAL ATTENTION TO AVOID

INTERRUPTION OF ANY FIRE WALL

10"

INTEGRITY







FLOATING RIDGE CAP



VENTILATION CORE 2"

81

/2"







51

1 1/ /2"

8"









2"







SHINGLES









3 3/4" MIN.



DATE:

10/12/98

TITLE:

ROOF TO

7777 Hollister Road

WALL

PART:



Houston, TX 77040

SHINGLE TYPE

(713) 856-9696 • 1-800-356-7746 CORAVENT

E-mail: info@mpvent.com

SV-01.3 / Rev. 03/00

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









PREVENT









…is one of our inVentive answers which features eave and ridge/hip components for an efficient, maintenance-

free roof ventilation system.



Standard Size Construction

Each section of PreVent comes in standard eight or ten- PreVent features Cobra® Ridge Vent material — a main-

foot lengths. Custom lengths are available. tenance-free, lightweight, polyester composite product.

It will not dent, crack, or rust. Model R-24 is made from

Design 24-gauge Galvalume® material. Models E-18 and E-16

All R-(ridge) series models are designed to work in con- are made of 18- and 16-gauge galvanized material,

junction with standard closures and ridge caps furnished by respectively.

your building or roof system supplier. The E-(eave) series

models are designed for eave venting and can be custom Advantages

formed to fit your application (Specify roof slope when Low cost. Ease of installation. No moving parts to wear out.

ordering.) All models feature a series of slots die cut the Energy efficient. Architecturally attractive. Adaptable to

entire length allowing 16.9 square inches of free area per many different roofing systems. No leaks. No snow infiltra-

linear foot. tion. No bird nesting. No wind-driven rain infiltration. No

heat and moisture buildup in attics.





BUILDINGS MUST BREATHE!

One of the most overlooked components of design and Ridge ventilators manufactured by Metallic Products are in

installation of roofing systems, both in new construction and accordance with the highest design requirements and specifica-

retrofit applications, is ventilation. A properly engineered venti- tions. 35 years plus of experience in furnishing stationary,

lation system using a proper ridge vent in conjunction with an gravity-flow, continuous ridge ventilators has proven their effi-

under soffit intake will provide proper fresh air movement cient performance and lasting quality.

through the roofing system removing hot, stale air. Summer heat PreVent ridge vents are a low-profile, aesthetically pleasing

is released naturally, extending both the life and performance of and extremely efficient means of ventilating metal roofs. Each

the roof. During winter proper ventilation can assist in the control unit is manufactured in 8 or 10' lengths and can be installed as a

of condensation and other moisture problems such as rust and single unit or can be butted together to form a continuous run,

insulation deterioration. creating the effect of a seamless design.



7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com

SV-02 / Rev. 2/01

Dimensions and Applications Ridge Cap

PreVent

Model R-24

PreVent Roof Panel

Model E-16



Air Flow









Support Framing

Eave

Support

Air Flow



Closure



RETRO FIT ROOF APPLICATION

Ridge and Eave Vents

Ridge Cap





1⁄2" 13⁄32"









Air Flow

ARCHITECTURAL RIDGE DETAIL

2"









1 1 ⁄ 2"



Cobra® Ridge Vent Material

11⁄2"









VENTILATING SLOTS

Used on all models

4" 1 ⁄2"

Cobra® Ridge Vent Material Technical Data:

Property Test Values

Air Permeability ASTM D737 >>760 cu. ft. per minute MODEL R-24

Tear and Tensile Strength ASTM D1294-86 Tear: Machine 25 p.p.i. 11⁄2"

Counter 25 p.p.i.

ASTM D2261-83 Tensile: Machine 25 p.p.i.

Counter 25 p.p.i.

Cobra® Ridge Vent Material

Self-Ignition Temperature ASTM D1929 963° F.

11⁄2"









Cold Crack Resistance LOREN C115 -25° F.

Snow Infiltration CRL 5704 —0—





S SI FI E Roof

LA BOCA 21⁄2" 31⁄2" Slope

D

C









See BOCA Evaluation Services, Inc.

Research Report #93-49



Made from over

90% recycled fiber:

over 30% post-consumer content

DADE COUNTY

Acceptance #94-0907.01 MODELS E-16 & E-18









METALLIC PRODUCTS • Houston, Texas 77040

(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746

Apex Ventilator

Round Ventilator







ROUND VENTILATORS









Turbine Ventilator

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









ROUND GRAVITY VENTILATORS









Standard Size Bird Screen

Round gravity ventilators are available in standard 12, Assembly is completed by the installation of a 4 x 4 bird

20, and 24 - inch diameter throat sizes. Other sizes up screen in the opening between the inner band and the

to 48 - inch available through special orders. rainshield to resist the entry of birds into the vent area.



Integral Dampers Finish

The addition of a vertical-lift type damper completes the Vents are furnished standard with white or galvalume

weather-tightness of the unit. The damper is supported finish, but are available in special colors when specifically

in the open position by four strong springs and is closed ordered.

by a long pull chain. Damper may be locked in any

position by the use of an optional key type chain lock Base Design

(please specify when ordering.) Ventilator may be fur- The base is specifically designed for the final installation,

nished without damper if desired. However, overspray with specified roof slope; either ridge or single slope, and

or driven rain may enter the vented space. Ventilator either flat or mounted into customer- furnished roof

with damper may function as a smoke exhaust vent by panel. Base and ventilating unit are furnished pre-as-

including a fusible link in the chain operator. sembled ready for installation. Single slope bases are

mounted directly into roof panel and are placed in such a

Construction way as to prevent damming.

26 gauge inner and outer bands, rainshield, and base

assembly are assembled with four pre-formed baffles Design

into a simple yet sturdy ventilation unit. This design Round gravity roof ventilators are designed for economi-

achieves a free unobstructed flow of ventilation air. cal, low volume air movement to ventilate warehouses,

light industrial buildings, attics, lofts and other buildings

requiring gravity or relief ventilation. They also are adapt-

able for use as discharge heads for mechanical or forced

air ventilation systems. The volume of gravity air move-

ment can be controlled by the adjustable damper. The

damper is also effective in controlling water intrusion

from wind-driven rain and back draft conditions.

Installation is by use of standard formed closures, tape sealant, caulking and fasteners as indicated on standard assembly

drawings. When ordering, please specify roof slope and base type. A wooden crate is included in price.

7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com

RV-01 / Rev. 8/01

DIMENSIONS AND TECHNICAL DATA



W W

OUTER

OUTER BAND

RAIN DAMPER BAND

SHIELD RAIN

SCREEN DAMPER

SHIELD SCREEN









H DAMPER

CLOSURE

H DAMPER

CLOSURE



TH TH

SPRING (4)

SPRING (4) INNER BAFFLE (4)

BAFFLE (4) BAND

INNER CHAIN CATCH PULL CHAIN (5 FT.)

BAND CHAIN CATCH

(OPTIONAL) PULL CHAIN (5 FT.)







RIDGE BASE RIDGE BASE

THROAT OPENING THROAT OPENING



12, 16, 24, 36 and 48" Throat Ventilators

20" Throat Ventilators





DIMENSIONS (In Inches) SHIPPING WEIGHT

Throat* W H TH LBS.

12 18 71⁄2 141⁄2 38

20 30 10 171⁄2 65

24 36 12 231⁄2 73









Type 1 Type 2









Type 3 Type 4



METALLIC PRODUCTS • Houston, Texas 77040

(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









Table of Capacities for Round Ventilators

TO ESTIMATE VENTILATOR CAPACITY:

Determine the height of vent above the air intakes and the “Temperature Difference” between inlet air temperature

and outlet air temperature with these two constants find the “Factor” from Table “A.” Multiply base rate C.F.M. from

“Table C” by the factor from “Table A.” The result is approximate vent capacity at “0” M.P.H. outside wind velocity.

Beside the factor in Table A is the letter A, B. C or D. This letter refers to a factor in Table “B.” Multiply vent capacity

for “0” M.P.H. wind by appropriate factor from Table “B” for vent capacity under the given wind condition.



EXAMPLE:

Use Ventilator Size 20"

Ventilator Height Above Intake 20'

Factor From Table “A” is .76A at 15 Temperature

Difference Multiply: .76 x 712 = 541 CFM at “0” M.P.H.

Using 3 M.P.H. Wind Vent Capacity is 541 x 1.14 = 617

C.F.M.



TABLE B

TABLE A

Wind Velocity Factors

Wind Factors

Height and Temperature Factors

M.P.H. A B C D

Temperature Difference 3 1.14 1.09 1.05 1.02

HEIGHT

IN FEET 15 20 25 30 35 40 50 5 1.25 1.18 1.13 1.09

15 .64A .78A .84A .90B .96B 1.02B 1.10C 7 1.41 1.29 1.22 1.16

20 .76A .86A .93B 1.00B 1.07B 1.13C 1.22C 9 1.62 1.43 1.33 1.25

25 .84A .95B 1.02B 1.10C 1 18C 1.25C 1.34C 11 1.82 1.57 1.43 1.32

30 .91B 1.03B 1.12C 1.20C 1.29C 1.36C 1.47D

35 .97B 1.09B 1.18C 1.27C 1.36C 1.43D 1.55D TABLE C

40 1.02B 1.15C 1.25C 1.34C 1.43D 1.52D 1.64D Base Ratings Per Unit

45 1.07B 1.20C 1.30C 1.40C 1.50D 1.58D 1.71D Size 12" 18" 20" 24"

50 1.11C 1.26C 1.36C 1.46D 1.56D 1.65D 1.78D C.F.M. 256 577 712 1026

RV-01.1 / Rev. 5/00









7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: mpv@mpvent.com · www.mpvent.com

DATE:



TITLE:

INSTALLATION

7777 Hollister Road

DETAILS

PART:



Houston, TX 77040 ROUND GRAVITY

(713) 856-9696 • 1-800-356-7746 VENT

E-mail: info@mpvent.com RV-5

RV-01.2 / Rev. 2/01

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









APEX VENTILATOR









...is designed specifically for architectural standing-seam retrofit applications and new construction applications

where maximum ventilation is required in an attractive, compact-profile unit.





Standard Size Construction

The Apex Ventilator comes standard in a 12-inch throat Screened outlet area prevents birds from entering venti-

size. Other sizes available upon request. lated area. All steel parts are 24 gauge steel. Screen is

expanded aluminum.

Design

The compact profile is an attractive design which allows for Finish

self-acting ventilation of standing-seam roofs. There are no Galvalume® finish is standard, and colors are available

moving parts to wear and no operating costs. No field including Kynar.® Please specify roof system, paint system

assembly means quick and easy installation. and color when ordering.









BUILDINGS MUST BREATHE!



One of the most overlooked components of design and Ventilators manufactured by Metallic Products are in accor-

installation of architectural roofing systems, both in new con- dance with the highest design requirements and specifications.

struction and retrofit applications, is ventilation. A properly 25 years plus of experience in furnishing stationary, gravity-

engineered ventilation system using a continuous ridge vent in flow, continuous ridge ventilators has proven their efficient

conjunction with an under soffit intake will provide proper fresh performance and lasting quality.

air movement through the roofing system removing hot, stale air. Apex Ventilators are a compact-profile, aesthetically pleas-

Summer heat is released naturally, extending both the life and ing and extremely efficient means of ventilating standing seam

performance of the roof. During winter proper ventilation can roofs. The units are effective in the ventilation retrofit applica-

assist in the control of condensation and other moisture problems tions or in new construction.

such as rust and insulation deterioration.



7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com

SV-03 / Rev. 2/01

DIMENSIONS AND TECHNICAL DATA



W







Cap





Rain Shield Angle Upper Outer Band

Damper

H Screen



Eye Bolt Baffle

TH

Lower Outer Band

Spring







Guide Rod Inner Band

Guide Rod Angle

Base



THROAT







DIMENSIONS (In Inches)

Throat* W H TH

12 18 6 13

16 27 113⁄8 20

20 331⁄2 15 22







TABLE OF CAPACITIES FOR APEX VENTILATOR FOR WHOLE BUILDING VENTILATION

TO ESTIMATE VENTILATOR CAPACITY:

Determine the heights of vent above the air intakes and the “Temperature Difference” between inlet air temperature and outlet

air temperature. With these two constants, find the “Factor” from Table “A.” Multiply 256 (Base Rating for a 12" Apex Vent) by

the factor from “Table A.” The result is approximate vent capacity at “0” m.p.h. outside wind velocity. Beside the factor in “Table

A” is the letter A, B, C or D. This letter refers to a factor in Table “B.” Multiply vent capacity for “0” m.p.h. wind by appropriate

factor from Table “B” for vent capacity under the given wind condition.



EXAMPLE: Ventilator Height Above Intake = 20'

A measured 15° Temperature Difference yields .76A from “Table A”

Multiply .76 x 256 = 194.56 C.F.M. at “0” m.p.h.

At 3 m.p.h Wind Velocity, Vent Capacity is 194.56 x 1.14 = apprx. 221.8 C.F.M.







TABLE A TABLE B

Air Movement per Lineal Foot Factors Wind Velocity Factors

HEIGHT Temperature Difference WIND Factors

IN FEET 15° 20° 25° 30° 35° 40° 50° M.P.H. A B C D

15 .64A .78A .84A .90B .96B 1.02B 1.10C 3 1.14 1.09 1.05 1.02

20 .76A .86A .93B 1.00B 1.07B 1.13C 1.22C 5 1.25 1.18 1.13 1.09

25 .84A .95B 1.02B 1.10C 1.18C 1.25C 1.34C 7 1.41 1.29 1.22 1.16

30 .91B 1.03B 1.12C 1.20C 1.29C 1.36C 1.47D 9 1.62 1.43 1.33 1.25

35 .97B 1.09B 1.18C 1.27C 1.36C 1.43D 1.55D 11 1.82 1.57 1.43 1.32

40 1.02B 1.15C 1.25C 1.34C 1.43D 1.52D 1.64D

45 1.07B 1.20C 1.30C 1.40C 1.50D 1.58D 1.71D

50 1.11C 1.26C 1.36C 1.46D 1.56D 1.65D 1.78D







METALLIC PRODUCTS • Houston, Texas 77040

(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









TURBINE VENTILATORS









Turbine ventilators are available in 4" to 24" throat sizes. Vents are mounted in standard metal building peak or

hillside base to pitch of building.

They are constructed of 24 gauge galvanized steel with

bottom thrust-type oil impregnated ball bearings. Vents When ordering, specify throat size, slope, screen or

are externally braced with aluminum painted steel brac- damper.

ing. Dampers are available upon request. Damper has

pull-chain operator. Turbines are shipped wood crated.









Type 1 Type 2









Type 3 Type 4





7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com

SV-04 / Rev. 2/01

EXHAST APPROX.

W T H W

CAP

4MI WIND SHIPPING

WEIGHT

CFM

OILLESS BEARIMG 19

10 17 425 17

OUTSIDE BRACE

12 20 19 531 21

14 20 1/2 22 700 28

CROWN 16 23 1/4 25 950 35

18 24 1/4 27 1/2 1200 36

20 26 30 1700 47

BLADE 24 31 1/4 35 2350 77

36 43 56 4600 225



NOTE: VENTS UP TO 16" HAVE THREE OUTSIDE BRACES.

VENTS 18" AND UP HAVE FOUR.





CROWN BLADE THROAT

"T" DIM. GALV.

GALV. GALV.

GAUGE GAUGE GAUGE

H

10 22 28 26



12 22 28 26

SEE ENLARGED DETAIL

OF SHAFT END 24

14 22 26

GREASE RESERVOIR

IN SHAFT HOUSING 24

16 20 26

18 20 26 24

20 20 26 24

24 20 26 24

T 36 20 24 20



SHAFT

DATE:

PRESS FIT STUD DATE

MAY 3, 1997

TITLE:



INTO SHAFT

BALL BEARING

SPECIFICATIONS

LOWER BEARING FOR 7777 Hollister Road PART:



VENTILATORS 14" FOR VENTS UP TO Houston, TX 77040

THRUS BEARING (713) 856-9696 • 1-800-356-7746 TURBINE VENT

AND UP & INCLUDING 12"

E-mail: info@mpvent.com

Commercial Fans



Domex





POWER VENTILATORS









HI-EX Fans

Industrial Fans

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









COMMERCIAL FANS









STANDARD FEATURES: OPTIONS:



• Wall-mount and roof-mount fans designed for • Dual-speed switch

heavy-duty usage

• Timer (12 hour)

• Belt drive

• Combination dual-speed switch and timer

• Single-speed motors up to 5 hp (See options for

• Interior fan guard

two speed motors)

• Exterior weather hood (helps prevent entrance of

• Balanced steel blades

moisture when fans are used for intake ventilation)

• Vibration tested assembly

• Large capacity motors (up to 5 hp, 230/460 volts,

• Self-lubricating ball bearings with dual-speeds)

• Standard motors are open drip-proof (ODP), 60Hz, • Two-speed motors, available on V series fans up

single phase, unless otherwise specified (See to 1/2 hp (CFM is reduced approximately 32% at

options for additional motor types) low speed)

• Crated for shipment • Totally enclosed and explosion proof motors are

available for all VI series fans



NOTE: Fans are available with automatically-opening wall

shutters. Also available installed in roof curb with “Air Intake

and Exhaust-Hoods.”









7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com

PV-01 / Rev. 2/01

EASY SIX-STEP INSTALLATION:

1. Construct a frame of 8 inches or 10 inches “C” channels 1/4 inch

larger than the overall fan size.

2. After mounting “C” channel frame to the building structure, cut

opening in exterior metal siding for shutter frame.

3. Place the shutter in opening with flange under siding and attach

with self tapping or sheet metal screws. After shutter is in-

stalled, caulk all four exterior sides of shutter.

4. Install fan in position leaving a min. of 4 inches between front

of fan and shutter. Fan mounts to “C” channels with self tapping

screws or machine bolts with lock washers.

5. With fan and shutter installed, proceed with electrical wiring.

See the motor label for proper wiring procedures.

6. Install IG or VIG guard on fans mounted less than 7 ft. above

the floor.









SPECIFICATIONS



BLADE SHIPPING O/O SQ. FLANGE

MODEL HP CFM AMPS VOLTS DEPTH

SIZE WT. (LBS) SIZE SIZE

V-SERIES COMMERCIAL

V 2412 1/3 5,100 4.5 24" 115 44 30" 11 ⁄ 2 " 131⁄2"

V 3012 1/3 7,500 4.5 30" 115 52 34" 11 ⁄ 2 " 131⁄2"

V 3613 1/3 12,500 7.8 36" 115 66 40" 2" 131⁄2"

V 4213 1/2 14,445 7.8 42" 115 72 46" 2" 131⁄2"

V 4813 1/2 17,025 7.8 48" 115 81 52" 2" 131⁄2"

V 4814 3/4 20,100 11.2/5.6 48" 115/230 89 52" 2" 131⁄2"

VI-SERIES INDUSTRIAL

VI 3613 1/2 11,800 7.8 36" 115 150 40" 2" 20"

VI 3614 3/4 12,100 11.2/5.6 36" 115/230 153 40" 2" 20"

VI 3615 1 12,560 11.0/5.5 36" 115/230 TE 158 40" 2" 20"

VI 4213 1/2 17,175 7.8 42" 115 158 46" 2" 20"

VI 4214 3/4 17,550 11.2/5.6 42" 115/230 168 46" 2" 20"

VI 4215 1 17,900 11.0/5.5 42" 115/230 TE 173 46" 2" 20"

VI 4216 1 1 ⁄2 18,425 4.6/2.3 42" 230/460/60/3 175 46" 2" 20"

VI 4814 3/4 20,100 11.2/5.6 48" 115/230 182 52" 2" 20"

VI 4815 1 20,950 11.0/5.5 48" 115/230 TE 184 52" 2" 20"

VI 4816 1 1 ⁄2 21,820 4.6/2.3 48" 230/460/60/3 190 52" 2" 20"

VI 4817 2 22,760 6.2/3.1 48" 230/460/60/3 197 52" 2" 20"

VI 4818 3 26,180 8.8/4.4 48" 230/460/60/3 210 52" 2" 20"

VI 5417 2 27,000 6.2/3.1 54" 230/460/60/3 338 62" 2" 24"

VI 5418 3 30,900 8.8/4.4 54" 230/460/60/3 343 62" 2" 24"

VI 5419 5 36,200 14.4/7.2 54" 230/460/60/3 343 62" 2" 24"

VI 6017 2 32,500 6.2/3.1 60" 230/460/60/3 410 68" 2" 24"

VI 6018 3 36,200 8.8/4.4 60" 230/460/60/3 418 68" 2" 24"

VI 6019 5 44,200 14.4/7.2 60" 230/460/60/3 422 68" 2" 24"







METALLIC PRODUCTS • Houston, Texas 77040

(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









FAN SHUTTERS & ACCESSORIES









SHUTTERS



STANDARD FEATURES: SPECIFICATIONS

• Shutter frames are heavy-gauge steel with rigidly

WALL

welded corners and finished with a tough, powder MODEL FAN WT.

DESCRIPTION OPENING

coated finish NUMBER SIZE (LBS)

SIZE

• Aluminum shutter blades are attached with heavy- Shutter

duty nylon fasteners IWS 24 33 3/8" x 33 3/8" 24" 31" x 31" 11

Shutter

• Automatic open/close operation as fan is turned

IWS 30 36 3/8" x 36 3/8" 30" 34" x 34" 15

on/off

Shutter

• Interlocking blades for maximum weather seal IWS 36 42 3/8" x 42 3/8" 36" 40" x 40" 21

• Double-panel units constructed with rigid “T” sec- Shutter

tion center member IWS 42 48 3/8" x 48 3/8" 42" 46" x 46" 25

Shutter

• Open depth of shutters is 4"

IWS 48 54 3/8" x 54 3/8" 48" 52" x 52" 30

Shutter

OPTIONS:

*IWS 54 64 3/8" x 64 3/8" 54" 61" X 61" 48

• Manual pull chain and chain latch

Shutter

• Motor operator, 115/230 volts (relieves starting *IWS 60 70 3/8" x 70 3/8 60" 67" X 67" 56

load on fan motor)

* INDICATES DOUBLE PANEL SHUTTER

• Electrostatic powder coated finish, a standard

color









7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com

PV-02 / Rev. 3/01

FAN GUARDS WEATHER

HOODS









The “IG” and “VIG” series Industrial Fan Guards should be

used on all fans mounted less than 7 ft. above the floor, to STANDARD FEATURES:

meet OSHA requirements. The grill has black powder-coat

finish. Offers protection from the elements when installed over

intake or exhaust fans, or over wall openings

The “VIG” guard for “VI” series fans consists of the grill only

which attaches to the fan housing on the intake side. • Heavy-duty galvanized construction

• Galvanized angle frames

The “IG” guard for “V” series fans is complete with 14 inch

deep galvanized housing and grill. It mounts on the intake • Flange frame for securing to building structure

side of the fan and is shipped unassembled. • Standard sizes to accommodate 24", 30", 36", 42",

and 48" fans

Fits • 1/2 inch mesh birdscreen at opening

V Series Fans • Assembled and crated



MODEL FAN SHIPPING

NUMBER SIZE WT. OPTIONS:

IG 3000 24 43

• Insect screen

IG 3600 30 50

IG 4200 36 58 • Filter frames

IG 4800 42 65 • Electrostatic powder-coated finish (2 mil)

IG 5400 48 73

• Shipped “KD” (knocked-down) for field assembly

• Also available in aluminum and Galvalume™ fin-

Fits ishes

VI Series Fans • Custom sizes available



MODEL FAN SHIPPING

NUMBER SIZE WT.

VIG 36 36 27

VIG 42 42 31

VIG 48 48 34

VIG 54 54 38

VIG 60 60 45









METALLIC PRODUCTS • Houston, Texas 77040

(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746

BREEZEWAY WALL MOUNTED EXHAUST PROPELLER FANS

ACCESSORIES AVAILABLE:

• WALL SHUTTER (GRAVITY)

• WALL MOUNTING COLLAR (KNOCKED DOWN)

• FRONT AND BACK GUARD







DIRECT DRIVE (TYPE P)

Versatile fans from 10” to 24” utilizing multi-speed motors

in selected sizes, using fabricated props, with performances

up to 6500 cfm.



BELT DRIVE (TYPE BLL)

Low cost fans designed specifically for low pressure applica-

tions, utilizing steel props, available in the three most popular

Penn Ventilation certifies that the Breezeway Models sizes 24”, 30”, & 36”, with performances to 14,000 cfm.

are licensed to bear the AMCA Seal. The ratings

shown are based on tests and procedures performed in

accordance with the AMCA Publication 211 and BELT DRIVE (TYPE BFM)

Publication 311 and comply with the requirements of Suitable in medium pressure applications beyond the BLL, uti-

the AMCA Certified Ratings Program. lizing steel props, available in all sizes from 24” to 48”, with

performances up to 32,400 cfm.

Breezeway fans carry the UL label, UL705, (ZACT),

File #E28413. Check Underwriters Laboratories Re-

Examination Service for specific units listed. PDQ models are exhaust only. Fans for supply applications are

available through normal channels with standard lead times.

Penn Breezeway Fans are also certified by the

Canadian Standard Association (File #LR13309)









DIMENSIONAL DATA







TYPE P

WALL APPROX

DIA. MAX. MAX.

MODEL A B C E F G H OPENING SHIP WT. PANEL

Wo (LBS.) GAUGE

P10 15 10-3/4 2-1/2 1 1-1/4 6-1/2 3/4 15-3/4 12 18

P12 17 12-1/4 3-1/4 1 1 7-1/2 1-7/8 17-3/4 14 18

P16 22-3/4 16-3/4 3-3/4 1 2-1/4 11-1/4 2-7/8 23-1/2 30 18

P18 24-1/4 18-3/4 3-3/4 1 2 9-1/8 3-5/8 25 40 18

P20 26-3/4 20-7/8 3-3/4 1 1-3/4 12-1/2 3-1/4 27-1/2 50 18

P24 32-1/4 25 4-1/4 2 2-3/8 12-7/8 11

4- /16 33 76 18

All wire frames are 11 gauge.









MAX.









215.464.8900 • Penn Ventilation

E

A F









MODEL BLL

DIA.

B

A MODEL A B D E F

BLL24 28 25 16 3 3

BLL30 34 31 18 2-1/2 3

BLL36 40 37 20 3 4-3/4





DMAX.



E

A F



MODEL BFM

MODEL A B D E F

BFM24 28 25 16 3 3

BFM30 34 31 18 2-1/2 3

A BDIA.

BFM36 40 37 20 3 4-3/4

BFM42 46 43 22 3-3/4 4-1/2

BFM48 54 49 25 2-3/4 4-3/4









DMAX.





Available for shipment from Junction City, KY, Reno, NV &

BREEZEWAY DIRECT DRIVE - P SERIES 24 MM UPS - P10VA thru P20SA Farnham, Quebec, Canada.

MAX TIP FAN CAPACITY IN CUBIC FEET PER MINUTE (CFM)

MODEL HP WATTS RPM SPEED 0.000" SP 0.100" SP 0.125" SP 0.150" SP 0.200" SP 0.250" SP 0.300" SP 0.375" SP 0.500" SP 0.625" SP

(FPM) CFM SONES CFM SONES CFM SONES CFM SONES CFM SONES CFM SONES CFM SONES CFM SONES CFM SONES CFM SONES

P10VA 1/30 80 1050 2749 753 4.6 531 7.5 457 7.9 385 7.2 239 6.7

P10RA 1/12 115 1550 4058 841 5.8 699 6.5 631 7.3 570 8.5 486 10.8 425 12.5 387 12.9 321 13.2

P12VA 1/12 147 1050 3299 1343 10.7 1177 9.5 1123 9.9 1057 10.5 874 11.1 689 10.1 433 10.0

P12RA 1/4 174 1550 4869 1489 10.3 1367 9.8 1326 10.1 1281 10.5 1160 11.7 1046 13.2 882 15.5 798 16.9 568 19.6 210 20

P16VA 1/3 463 1050 4398 2546 9.1 2088 8.8 1859 8.7 1699 8.6 1257 8.3

P16SA 1/2 550 1300 5445 3143 13.7 2933 14.0 2856 14.1 2758 14.3 2495 14.6 2244 15.0 1982 15.3 1671 15.4

P16RA 1/2 724 1550 6492 3555 14.0 3301 14.1 3256 14.1 3211 14.2 3102 14.5 2955 15.3 2736 16.9 2514 18.3 1979 20 1772 21

P16Q1A 3/4 962 1650 6911 3760 16.3 3557 16.6 3508 16.7 3459 16.7 3358 16.9 3256 17.1 3123 17.6 2864 18.9 2369 22 2032 24

P18VA 1/2 522 1050 4948 4210 15.2 3845 15.1 3768 15.1 3661 15.1 3370 15.3 3030 15.1 2719 13.6 2215 13.1

P18RA 3/4 1265 1550 7304 5233 20 4971 21 4971 21 4919 21 4787 22 4633 23 4383 25 4029 28 3547 35 3083 34

P20TA 3/4 815 1140 5969 4852 16.2 4449 16.4 4318 16.5 4185 16.7 3898 17.1 3570 17.7 3278 18.4 2717 20 1969 24 1200 25

P20SA 1 1415 1300 6807 6063 22 5786 22 5692 21 5597 21 5397 21 5149 21 4835 21 4466 21 3909 22 3121 23

P24VA 3/4 1117 1050 6597 6562 14.6 6210 14.6 6136 14.7 6063 14.7 5917 14.7 5758 14.9 5576 15.2 5249 15.8 4065 19.3 3654 21

Performance shown is for installation Type A: Free Inlet, Free Outlet. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are for loudness values in fan sones

at 5’0” (1.5m) in a hemispherical free field per AMCA Standard 301. Values shown are for Installation Type A: free inlet fan sone levels. Performance ratings include the effect of backguard in the airstream. For

models shown on this page, the AMCA Certified Ratings Seal applies to air and sound. See page 33 for accessories. See page 34 for speed control availability.





BREEZEWAY V-BELT DRIVE - TYPE BLL 24 MM Available for shipment from Junction City, KY & Farnham, Quebec, Canada.

TIP FAN CAPACITY - CUBIC FEET PER MINUTE (CFM)

MODEL HP RPM SPEED 0.000" SP 0.100" SP 0.125" SP 0.150" SP 0.200" SP 0.250" SP 0.300" SP 0.375" SP 0.500" SP

(FPM) Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP

1/4 737 4631 4771 4209 4010 3798 3120 2353

15.5 0.28 14.4 0.30 14.3 0.30 14.2 0.30 14.2 0.30 14.7 0.30

1/3 792 4976 5127 4620 4456 4266 3753 3095

16.9 0.35 15.9 0.36 15.7 0.37 15.6 0.37 15.6 0.37 15.9 0.37

BLL24 1/2 912 5730 5904 5465 5355 5226 4906 4484 3934 3010

22 0.53 21 0.55 20 0.55 20 0.56 19.4 0.57 19.1 0.57 19.1 0.57 19.6 0.57

3/4 1048 6585 6785 6402 6306 6211 5996 5718 5432 4735 3405

25 0.81 24 0.83 24 0.83 24 0.84 23 0.85 23 0.86 23 0.86 24 0.87 24 0.87

1 1124 7062 7277 6920 6831 6742 6563 6333 6066 5567 4426

31 1 29 1.02 29 1.02 29 1.03 28 1.04 27 1.05 27 1.06 27 1.07 27 1.07

1/4 531 4170 6739 5320 4767 4029 2138

12.2 0.26 12.0 0.29 12.2 0.29 12.4 0.27 13.7 0.28

1/3 572 4492 7260 6007 5567 5025 3123 1995

13.8 0.33 13.7 0.36 13.8 0.36 14.0 0.36 14.8 0.33 15.9 0.36

BLL30 1/2 657 5160 8339 7299 6988 6632 5732 4020 2762 1675

18.1 0.50 18.0 0.53 18.0 0.54 18.0 0.54 18.5 0.54 19.5 0.51 21 0.53 22 0.57

3/4 756 5938 9595 8671 8461 8212 7612 6844 5908 3619 1887

21 0.76 21 0.80 21 0.80 21 0.81 21 0.83 22 0.82 22 0.79 24 0.79 26 0.87

1 810 6362 10281 9406 9210 9015 8512 7891 7129 5107 2842

23 0.94 22 0.98 23 0.98 23 0.99 23 1.01 23 1.02 23 1.01 24 0.95 27 1.01

Performance shown is for installation Type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. The sound ratings shown are for loudness values in fan sones at 5’0” (1.5m) in a hemi-

spherical free field per AMCA standard 301. Values shown are for installation Type A: Free inlet fan sone levels. Performance ratings do not include the effects of appurtenances in the airstream. See page 33 for

accessories.





Penn Ventilation • 215.464.8900 24 MM Motors Mounted, complete ready to ship within 24 hours

BREEZEWAY V-BELT DRIVE - TYPE BLL 24 MM

TIP FAN CAPACITY - CUBIC FEET PER MINUTE (CFM)

MODEL HP RPM SPEED 0.000" SP 0.100" SP 0.125" SP 0.150" SP 0.200" SP 0.250" SP 0.300" SP 0.350" SP

(FPM) Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP

1/4 381 3561 9017 5770 3780 2949

9.9 0.25 9.6 0.26 10.3 0.27 10.6 0.29

1/3 410 3832 9703 7170 5052 3829

11.4 0.31 10.6 0.33 11.3 0.31 11.8 0.34

BLL36 1/2 472 4411 11170 9272 8626 7417 4361

15.3 0.48 14.2 0.50 13.8 0.51 14.3 0.50 15.6 0.52

3/4 543 5075 12851 11260 10819 10302 8471 5522 4295

18.9 0.73 18.4 0.76 18.2 0.76 18.0 0.77 18.3 0.76 19.3 0.77 19.8 0.85

1 582 5440 13774 12296 11913 11473 10238 7234 5508 4505

19.8 0.90 20 0.93 20 0.94 20 0.94 19.9 0.95 20 0.90 21 0.98 21 1.05

Performance shown is for installation Type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. The sound ratings shown are for loudness values in fan sones at 5’0” (1.5m) in a hemi-

spherical free field per AMCA standard 301. Values shown are for installation Type A: Free inlet fan sone levels. Performance ratings do not include the effects of appurtenances in the airstream. See page 33 for

accessories.









BREEZEWAY V-BELT DRIVE - TYPE BFM 24 MM

TIP FAN CAPACITY - CUBIC FEET PER MINUTE (CFM)

MODEL HP RPM SPEED 0.000" SP 0.100" SP 0.125" SP 0.150" SP 0.200" SP 0.250" SP 0.375" SP 0.500" SP 0.625" SP

(FPM) Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP

1/4 677 4342 5290 4524 4250 3936 3192 1898

14.7 0.29 13.9 0.30 13.7 0.30 13.6 0.30 13.4 0.30 13.4 0.30

1/3 728 4669 5688 5007 4771 4508 3902 2934

16.0 0.36 15.4 0.37 15.0 0.37 14.6 0.37 14.5 0.37 14.5 0.37

1/2 838 5375 6548 5992 5822 5625 5176 4657 2489

BFM24 19.7 0.55 19.2 0.56 18.9 0.56 18.6 0.56 18.0 0.57 17.8 0.56 17.7 0.56

3/4 963 6177 7525 7061 6925 6788 6451 6068 4919 2788

24 0.84 23 0.84 23 0.84 23 0.85 22 0.86 22 0.86 21 0.86 21 0.86

1 1032 6619 8064 7643 7515 7388 7104 6773 5771 4201

26 1.03 25 1.03 25 1.04 24 1.04 24 1.05 24 1.06 23 1.05 23 1.06

1-1/2 1186 7607 9267 8903 8812 8704 8482 8243 7500 6597 5390

31 1.56 30 1.57 30 1.57 30 1.57 29 1.58 29 1.59 28 1.61 28 1.59 28 1.61

1/4 442 3529 6875 5618 5065 3891

15.1 0.29 14.8 0.30 14.7 0.30 14.4 0.28

1/3 476 3801 7404 6297 5906 5311 3514

15.0 0.36 14.7 0.37 14.7 0.37 14.5 0.37 14.0 0.36

1/2 547 4368 8508 7589 7314 6996 6056 4248

16.8 0.55 16.7 0.57 16.6 0.57 16.5 0.57 16.1 0.57 15.4 0.54

BFM30 3/4 629 5022 9784 9013 8793 8557 8025 7275 4306

20 0.83 19.8 0.86 19.7 0.86 19.5 0.86 19.4 0.86 19.2 0.87 18.2 0.86

1 675 5390 10499 9794 9592 9385 8940 8393 5342

23 1.03 22 1.06 22 1.06 22 1.07 22 1.07 22 1.06 20 1.01

1-1/2 775 6188 12055 11451 11289 11118 10758 10370 9040 6038

28 1.56 27 1.59 26 1.60 26 1.61 25 1.61 25 1.61 26 1.62 25 1.53

2 855 6827 13299 12760 12614 12467 12153 11822 10861 9276 6505

33 2.09 31 2.13 31 2.14 30 2.15 30 2.16 29 2.17 29 2.16 30 2.16 28 2.08

1/4 364 3431 8137 5969 5109

8.5 0.26 9.1 0.30 9.4 0.30

1/3 392 3695 8763 7051 6106 5365

9.7 0.32 10.2 0.37 10.5 0.37 10.8 0.37

1/2 451 4251 10082 8838 8301 7517 6138

12.0 0.49 12.2 0.55 12.4 0.56 12.8 0.57 13.5 0.57

3/4 518 4882 11579 10601 10266 9852 8563 7335

BFM36 16.2 0.75 16.0 0.81 16.0 0.83 15.9 0.85 16.4 0.86 17.1 0.85

1 556 5240 12429 11542 11269 10927 10026 8698

18.0 0.92 17.6 1.00 17.6 1.01 17.6 1.03 17.5 1.06 18.4 1.06

1-1/2 639 6022 14284 13541 13327 13098 12533 11778 9144

27 1.40 26 1.49 25 1.51 25 1.53 24 1.57 24 1.61 24 1.61

2 704 6635 15738 15076 14892 14696 14273 13719 11526 9390

27 1.87 26 1.97 26 1.99 26 2.01 26 2.06 25 2.10 26 2.16 27 2.17

3 808 7615 18062 17494 17347 17186 16850 16487 15245 13124 11221

39 2.83 38 2.94 38 2.96 38 2.99 37 3.04 37 3.09 35 3.22 35 3.26 35 3.26

1 403 4431 15483 13597 12906 12076 10151 7012

18.1 1.03 17.1 1.06 16.7 1.07 16.3 1.05 15.9 1.01 16.4 1.02

1-1/2 463 5091 17788 16241 15785 15201 13802 12064

22 1.56 21 1.60 21 1.61 21 1.62 20 1.59 19.7 1.53

BFM42 2 511 5619 19632 18267 17875 17469 16389 15026 10227

27 2.10 26 2.15 25 2.15 25 2.16 24 2.17 24 2.13 23 2.04

3 586 6443 22514 21367 21038 20695 19983 19059 15925 11359

32 3.17 31 3.22 31 3.23 31 3.24 30 3.26 30 3.28 28 3.13 28 3.08

5 696 7653 26740 25775 25533 25290 24714 24137 22251 19604 16948

40 5.30 40 5.37 40 5.39 40 5.40 39 5.43 39 5.45 38 5.49 37 5.3 37 5.19

3/4 315 3958 17478 14975 14138 13265 9778

13.5 0.75 12.9 0.84 12.9 0.85 13.0 0.86 13.4 0.85

1 338 4247 18754 16504 15767 14979 12841 9510

15.4 0.93 14.7 1.03 14.6 1.04 14.6 1.05 14.9 1.06 15.4 1.06

1-1/2 389 4888 21584 19726 19169 18556 17203 15621

BFM48 18.8 1.42 17.8 1.54 17.7 1.56 17.5 1.58 17.4 1.61 17.5 1.62

2 429 5391 23803 22159 21690 21184 20046 18806 13159

22 1.90 21 2.04 21 2.07 20 2.09 20 2.13 20 2.16 21 2.15

3 492 6183 27299 25906 25516 25115 24244 23269 20490 14860

31 2.87 30 3.03 30 3.07 29 3.10 29 3.16 29 3.20 28 3.27 30 3.25

5 584 7339 32404 31260 30951 30631 29970 29270 27209 24926 20362

44 4.80 43 5.00 43 5.05 42 5.09 42 5.18 42 5.25 41 5.38 41 5.46 41 5.41

Performance shown is for installation Type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. The sound ratings shown are for loudness values in fan sones at 5’0” (1.5m) in a hemi-

spherical free field per AMCA standard 301. Values shown are for installation Type A: Free inlet fan sone levels. Performance ratings do not include the effects of appurtenances in the airstream. See

page 33 for accessories. See page 34 for speed control availability.



Available for shipment from Junction City, KY & Farnham, Quebec, Canada. 215.464.8900 • Penn Ventilation

HI-EX VERTICAL DISCHARGE AIR EXHAUSTERS

AVAILABLE WITH:

• MOTOR (SEE PAGE 34)

• DISCONNECT SWITCH

• INLET GUARD

• MAGNETIC LATCHES

• REMOTE DRIVE (HC AND HF ONLY)







A continuing demand exists in commercial and industrial buildings for high

velocity roof ventilators which exhaust foul air and disperse it high above the

roof. The HI-EX is ideal for the “spot” ventilation of specific problem areas

where rapid air removal is necessary or for general plant ventilation. This

“plug-in” or package ventilation is easily installed out of the way, up on the

roof. It is accessible and yet does not use valuable interior areas nor does it

require costly duct systems.

Dampers open automatically when the fan is started. The airstream holds the

dampers open and excludes weather until the power is shut off. Then, the

dampers automatically close tight as the air blast diminishes.

All units are galvanized construction.









DIMENSIONAL DATA HI-EX MODELS HC, HF



L



V - BELT DRIVE MODELS HC, HF

FABRICATED A

FAN UNIBEAM GAUGE

DIAM. A H CURB H

L Ro T E

O2 T2 STEEL

24 26 40 33 26 331/2 35 301/2 331/2 16-20

30 32 44 39 32 391/2 41 361/2 391/2 16-20

36 38 48 45 38 451/2 47 421/2 451/2 16-20 E SQ. INSIDE BASE

42 44 51 51 44 511/2 53 481/2 511/2 14-18 T2

48 50 60 57 51 581/2 60 551/2 581/2 14-18

O2



R0







HI-EX MODEL HC (CAST ALUMINUM PROP) 10 QB

TIP FAN CAPACITY C.F.M.

MODEL RPM SPEED 0”S.P. .125”S.P. .250”S.P. .375”S.P. .500”S.P. .750”S.P. 1.000”S.P.

F.P.M. CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP

1105 6943 4895 0.29 4350 0.32 3610 0.33 2730 0.33 2015 0.35

1265 7948 5600 0.43 5150 0.46 4505 0.49 3850 0.49 3080 0.49 1895 0.55

HC24

1450 9111 6420 0.65 6030 0.68 5555 0.72 4935 0.74 4370 0.74 3030 0.77 2115 0.83

1595 10022 7065 0.87 6715 0.90 6315 0.95 5800 0.97 5240 0.99 4080 0.98 3045 1.05

890 6690 8485 0.42 7525 0.46 6415 0.49 4545 0.48 2120 0.45

1020 8011 9725 0.63 8920 0.69 8025 0.72 6785 0.74 5075 0.72

HC30 1125 8836 10725 0.84 10010 0.92 9180 0.95 8310 0.99 6980 1.00 3300 0.92

1285 10092 12250 1.26 11640 1.35 10925 1.40 10200 1.44 9430 1.48 6985 1.46 3525 1.37

Power rating (BHP) does not include drive losses. Performance shown is for installation Type A: Free inlet, Free outlet. Performance ratings include the effects of the dampers. See page 31 for

roof curb availability.







10 QB Quick Build, 10 day custom build program. Available for shipment from Junction City, KY & Farnham, Quebec, Canada.



215.464.8900 • Penn Ventilation

HI-EX MODEL HC (CAST ALUMINUM PROP) 10 QB

TIP FAN CAPACITY C.F.M.

MODEL RPM SPEED 0”S.P. .125”S.P. .250”S.P. .375”S.P. .500”S.P. .750”S.P. 1.000”S.P.

F.P.M. CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP

635 5985 11585 0.69 10150 0.73 8080 0.74 4455 0.67

700 6597 12770 0.92 11500 0.97 9780 1.00 7590 0.97 3955 0.88

HC36 800 7540 14595 1.37 13515 1.44 12225 1.48 10490 1.48 8455 1.44

880 8294 16055 1.83 15085 1.90 13970 1.86 12550 1.98 10995 1.96 5575 1.75

1010 95196 18425 2.76 17595 2.85 16675 2.92 15660 2.98 14340 2.99 11415 2.92 6280 2.64

550 048 14775 0.94 12845 0.98 9775 0.98 5870 0.94

630 6927 16925 1.41 15300 1.47 13025 1.48 9945 1.47 6495 1.40

HC42 695 7642 18670 1.89 17225 1.97 15450 1.98 12895 1.99 9895 1.97

795 8742 21360 2.84 20120 2.92 18705 2.96 16840 2.98 14570 2.97 9240 2.85

945 10391 25390 4.76 24365 4.88 23250 4.95 22055 4.97 20445 5.00 1660 4.98 12085 4.85

540 6787 20740 1.40 18060 1.45 14775 1.44 9805 1.35

600 7540 23045 1.92 20660 1.98 17935 2.00 14605 1.94 8295 1.82

HC48 685 8608 26310 2.86 24245 2.93 21995 2.98 19410 2.96 16410 2.88

810 10179 31110 4.72 29385 4.81 27565 4.89 25595 4.93 23415 4.91 18515 4.72

Power rating (BHP) does not include drive losses. Performance shown is for installation Type A: Free inlet, Free outlet. Performance ratings include the effects of the dampers. See page 31 for

roof curb availability.









HI-EX MODEL HF (STEEL PROP) 10 QB

TIP FAN CAPACITY C.F.M.

MODEL RPM SPEED 0”S.P. .125”S.P. .250”S.P. .375”S.P. .500”S.P.

F.P.M. CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP

611 3839 4890 0.30 4075 0.30 2565 0.29 1735 0.33

672 4222 5375 0.39 4685 0.40 3190 0.38 2325 0.41

HF24

750 4712 6000 0.55 5410 0.55 4190 0.52 3155 0.54 2495 0.58

857 5385 6855 0.82 6320 0.81 5680 0.81 4320 0.78 3550 0.80

943 5925 7545 1.09 7065 1.08 6555 1.10 5470 1.04 4425 1.04

440 3465 6640 0.29 4525 0.28 2280 0.31

484 3801 7305 0.39 5655 0.38 2450 0.40

HF30 538 4225 8120 0.54 6775 0.54 3815 0.52 2775 0.57

615 4830 9280 0.80 8225 0.82 6190 0.76 3530 0.80 3085 0.86

678 5325 10230 1.08 9335 1.10 7845 1.05 5205 1.02 3325 1.10

775 6087 11695 1.61 10970 1.64 9860 1.62 8200 1.54 5785 1.53

370 3487 9445 0.40 6950 0.37

412 3883 10515 0.55 8265 0.52 3875 0.51

470 4430 11995 0.82 10120 0.78 7570 0.75 3135 0.78

HF36 520 4901 13270 1.11 11640 1.07 9705 1.02 5585 1.02

594 5598 15160 1.65 13815 1.60 12060 1.56 10115 1.51 6090 1.52

654 6164 16690 2.20 15500 2.15 13980 2.10 12530 2.05 10190 2.02

750 7069 19140 3.32 18135 3.26 16895 3.20 15505 3.15 14275 3.08

391 4299 14530 0.81 12940 0.81 7480 0.80

430 4728 15980 1.08 14735 1.09 10485 1.05 5830 1.13

HF42 492 5410 18285 1.62 17370 1.64 15090 1.57 10210 1.59

542 5960 20145 2.17 19355 2.19 17765 2.15 14030 2.09 9765 2.14

620 6817 230 3.25 22410 3.28 21370 3.28 19555 3.17 15760 3.13

735 80824 27315 5.41 26830 5.45 26115 5.47 25090 5.45 23665 5.30

323 059 18195 0.81 13475 0.82

355 4461 20000 1.08 16030 1.09 9080 1.13

HF48 407 5115 22930 1.62 19810 1.65 14585 1.65

448 5630 25235 2.16 22595 2.20 18310 2.20 12585 2.24

513 6447 28900 3.25 26810 3.30 23500 3.30 19230 3.30 14060 3.37

608 7640 34250 5.41 32680 5.49 30245 5.49 27235 5.49 23625 5.50

Power rating (BHP) does not include drive losses. Performance shown is for installation Type A: Free inlet, Free outlet. Performance ratings include

the effects of the dampers. See page 31 for roof curb availability.









10 QB Quick Build, 10 day custom build program. Available for shipment from Junction City, KY & Farnham, Quebec, Canada.







Penn Ventilation • 215.464.8900

HITESAVER MODEL HS V-BELT DRIVE

RECOMMENDED FOR COMMERCIAL USE

For applications where height is a consideration, Penn introduces the HiteSaver, Model HS.

The HiteSaver features an extra-low profile. The propeller, motor and drive are recessed into

the roof opening and extend below the roof line. This design provides for convenient access

from the building interior when structural members provide clearance.

The windband is constructed of galvanized steel and contains two reinforcing ribs. This

assembly is supported by the curb base and steel brackets. The curb base is all-welded heavy

gauge galvanized steel with a deep spun venturi to smooth airflow. External bracing pro-

vides extra rigidity. Integral lifting lugs are included.



Penn Ventilation certifies that the Model HS Roof Exhausters

shown are licensed to bear the AMCA Seal. The ratings shown are

based on tests and procedures performed in accordance with

AMCA Publication 211 and Publication 311 and comply with the

requirements of the AMCA Certified Ratings Program.



PERFORMANCE DATA 10 QB

TIP FAN CAPACITY – C.F.M. SONES

MODEL RPM SPEED 0" S.P. .125" S.P. .250" S.P. .375" S.P. .500" S.P. @

F.P.M. CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 0.125"

743 5836 9174 0.78 8309 0.83 7258 0.87 15.4

HS30 797 6260 9841 0.96 9039 1.02 8105 1.06 17.9

915 7186 11298 1.45 10611 1.52 9838 1.58 8968 1.62 23

1008 7917 12446 1.94 11831 2.02 11156 2.09 10410 2.14 9586 2.17 27

514 4844 12345 0.78 10563 0.84 15.8

HS36 551 5193 13234 0.96 11578 1.03 9831 1.08 17.0

633 5966 15203 1.45 13775 1.53 12265 1.60 19.6

697 6569 16740 1.94 15447 2.03 14108 2.11 12731 2.17 22

465 5113 17921 1.50 15971 1.57 13683 1.63 16.7

513 5641 19770 2.01 18029 2.09 15986 2.15 20

HS42 588 6465 22661 3.03 21162 3.12 19467 3.19 17654 3.27 26

698 7675 26900 5.07 25638 5.17 24325 5.27 22827 5.35 21297 5.44 35

799 8785 30793 7.60 29690 7.72 28586 7.84 27386 7.95 26037 8.03 44

391 4913 21647 1.45 18724 1.54 14310 1.54 6884 1.62 17.0

431 5416 23862 1.94 21390 2.05 17699 2.09 12463 2.06 20

HS48 495 6220 27406 2.94 25370 3.07 22454 3.15 19095 3.17 14094 3.13 25

587 7376 32499 4.91 30793 5.05 28783 5.19 26130 5.28 23272 5.29 32

673 8457 37261 7.39 35772 7.56 34212 7.73 32142 7.86 29828 7.96 39

Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. The sound ratings shown are for loudness values in fan sones

at 5'0" (1.5m) in a hemispherical free field per AMCA Standard 301. Values shown are for installation type A: free inlet fan sone levels. Performance ratings include the effect of

backdraft damper in the airstream.









DIMENSIONAL DATA

FAN DIAM. H L Ro E F

30 24 36 34 38-1/2 15

36 26 42 40 44-1/2 15

42 30 48 46 50-1/2 18

48 32 54 52 56-1/2 18

ALL DIMENSIONS IN INCHES.







This model also available UL Listed for Heat & Smoke Control

through normal channels with standard lead time.









10 QB Quick Build, 10 day custom build program. Available for shipment from Junction City, KY & Farnham, Quebec, Canada.





215.464.8900 • Penn Ventilation

DOMEX CENTRIFUGAL ROOF EXHAUSTERS

Domex spun aluminum centrifugal roof fans are ideal for high volume, lower pressure air exhaust.

These durable products are found on roofs throughout the world in a wide range of commercial,

industrial and institutional buildings. Domex units include deep spun venturis, all aluminum non-

overloading wheels and can include optional Lektrol speed controller (Direct Drive only) and curb.

These models carry the AMCA Certified Ratings seal, UL and CSA labels.



DIRECT DRIVE V-BELT DRIVE

ALL UNITS STOCKED WITH: ALL UNITS STOCKED WITH:

• 115/1/60 OPEN DRIP PROOF MOTOR • MOTOR (SEE PAGE 34)

• POLARIZED DISCONNECT PLUG • POWER DISCONNECT SWITCH

• INTERNAL WIRING • INTERNAL WIRING

• ALUMINUM BIRD SCREEN • ALUMINUM BIRD SCREEN

• BACKDRAFT DAMPER • BACKDRAFT DAMPER







DOMEX HIGH CAPACITY V-BELT DRIVE

Penn Ventilation certifies that the Domex Direct and Penn Ventilation certifies that the Domex High

Belt Drive Models shown are licensed to bear the Capacity Belt Drive Models shown are licensed to

AMCA Seal. The ratings shown are based on tests bear the AMCA Seal. The ratings shown are based on

and procedures performed in accordance with tests and procedures performed in accordance with

AMCA Publication 211 and Publication 311 and AMCA Publication 211 and Publication 311 and

comply with the requirements of the AMCA Certified comply with the requirements of the AMCA Certified

Ratings Program. Ratings Program.



DIMENSIONAL DATA - DIRECT & V-BELT DRIVE

MODELS DX08, DX10, & DX11 MODEL DX13 MODELS DX06B, DX08B, & DX11B MODELS DX12B, DX14B, DX16B,

L (Dia.)

DX18B, DX24B, DX30B, & DX36B*

L (Dia.) L (Dia.) L (Dia.)









H H









E (Sq., inside base)

E (Sq., inside base)

E (Sq., inside base) E (Sq., inside base)

MODEL DX16 L (Dia.)

L (Dia.)



High Capacity Models KB420 & JB48



H Belt Drive Models DX06B -

DX30B available:



24 MM

Models DX36B - JB48 avail-

able from Tabor City, NC only:



E (Sq., inside base) 10 QB

E (Sq., inside base)

DIA.

MODEL L H E* Roof Opening

Direct Drive Models available: DX06B 21-11/16 18-13/16 18-1/2 X 18-1/2 11-1/2 X 11-1/2

DX08B 21-11/16 18-13/16 18-1/2 X 18-1/2 11-1/2 X 11-1/2

24 MM Motors Mounted, complete ready to ship within 24 hours DX11B 28-1/2 25-7/16 20-1/2 X 20-1/2 16 X 16

DX12B 33-1/2 29 24-3/4 X 24-3/4 16 X 16

MODEL DIA. H E* Roof Opening DX14B 33-1/2 29 24-3/4 X 24-3/4 16 X 16

L

DX08S/R 20-7/8 13-3/8 18-1/2 X 18-1/2 9X9 DX16B 39 31 28-1/2 X 28-1/2 20 X 20

DX10S/R 20-7/8 13-3/8 18-1/2 X 18-1/2 11-1/2 X 11-1/2 DX18B 39 31 28-1/2 X 28-1/2 20 X 20

DX11V/S/R & Q 20-7/8 13-3/8 18-1/2 X 18-1/2 11-1/2 X 11-1/2 DX24B 46 33-1/2 33-1/2 X 33-1/2 25 X 25

7 DX30B 53-1/2 35-1/2 36-1/2 X 36-1/2 28 X 28

DX13V/S/R & Q 21- /16 14-3/4 18-1/2 X 18-1/2 11-1/2 X 11-1/2

DX36B 66 41 44-1/2 X 44-1/2 36 X 36

DX16V/S/R, Q1 & Q2 28-1/2 22-1/2 20-1/2 X 20-1/2 16 X 16

KB420 63 38 52-1/2 X 52-1/2 44 X 44

JB48 73 45-1/2 59 X 59 50 X 50



215.464.8900 • Penn Ventilation

DOMEX DIRECT DRIVE 24 MM UPS - DX08S THRU DX13Q

FAN CAPACITY – CUBIC FEET PER MINUTE (CFM)

Fan Nominal Tip Speed 0.000" SP 0.125" SP 0.250" SP 0.375" SP 0.500" SP 0.625" SP 0.750" SP 0.875" SP 1.000" SP 1.250" SP

Model HP Max Watts RPM FPM CFM SONES CFM SONES CFM SONES CFM SONES CFM SONES CFM SONES CFM SONES CFM SONES CFM SONES CFM SONES



DX08S 1/50 44 1300 3361 237 1.5 161 2.2 114 3 69 3.8



DX08R 1/30 55 1550 4007 290 2.4 223 2.8 171 3.5 129 4.1 84 4.9



DX10S 1/25 82 1300 3361 385 3.9 316 3.5 257 4.8 207 5.1 168 5.2 129 5.6 82 6.1



DX10R 1/12 121 1550 4007 559 6.1 501 5.9 446 6.1 394 6.5 338 6.8 267 7 187 7.2 100 7.4



DX11V 1/25 111 1050 3058 388 1.8 223 2.2 148 3.1 112 3.7 80 4.5 49 5.3



DX11S 1/11 142 1300 3786 503 3.4 397 3.6 320 4.3 262 5 201 5.5 149 6 104 6.5



DX11R 1/7 201 1550 4514 736 6.7 659 6.4 577 6.6 502 6.9 432 7.6 356 7.9 274 7.9 188 7.9 100 7.9



DX11Q 1/5 268 1725 5024 997 10.2 921 9.7 850 9.5 768 9.5 685 9.4 598 9.2 511 9 409 8.7 294 8.6



DX13V 1/20 92 1050 3221 661 4.4 479 3.1 341 2.8 262 3.6 207 4.3 161 5.1 115 5.9 79 6.6 44 7.4



DX13S 1/12 120 1300 3988 869 8 749 6.4 632 5.3 510 5.4 418 6 349 6.4 290 6.7 226 7 158 7.4



DX13R 1/6 201 1550 4755 1054 10.5 988 9.9 917 9.2 839 8.9 736 8.5 651 8.2 579 7.9 510 7.9 428 8 191 8.5



DX13Q 1/4 314 1725 5292 1280 16 1226 15.3 1170 14.6 1112 14 1053 13.4 995 13 936 12.5 868 12 796 11.5 630 11



DX16V 1/6 453 1050 3788 1738 9.9 1489 8 1256 6.6 1032 6.1 884 6.6 772 7.1 682 7.9 598 9.9 529 10.1 392 10.2



DX16S 1/3 510 1300 4690 2021 12 1822 10.6 1637 9.5 1428 8.7 1256 8.4 1094 8.5 943 9.3 850 10.2 775 11 606 12.3



DX16R 1/2 574 1550 5592 2346 13.8 2176 12.8 2014 12 1853 11.3 1685 10.7 1532 10.4 1384 10.1 1247 10 1115 10.4 881 12.4



DX16Q1 1/2 688 1650 5953 2701 16.9 2576 16.4 2465 15.9 2352 15.5 2228 15 2096 14.4 1966 14 1839 13.6 1700 13.5 1401 13.5



DX16Q2 3/4 866 1725 6223 3016 17.7 2921 17.1 2829 16.7 2747 16.3 2665 15.9 2575 15.5 2484 15 2371 14.6 2256 14.2 2005 13.3



Performance shown is for installation Type A: Free Inlet, Free Outlet. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are for loudness values in fan sones at

5'0" (1.5m) in a hemispherical free field per AMCA Standard 301. Values shown are for Installation Type A: free inlet fan sone levels. See page 34 for speed control availability. Performance ratings do not include

the effects of appurtenances in the airstream. See page 31 for roof curb availability.





DOMEX V-BELT DRIVE 24 MM UPS - DX06 & DX08B

TIP FAN CAPACITY - CUBIC FEET PER MINUTE (CFM)

MODEL HP RPM SPEED 0.000" SP 0.125" SP 0.250" SP 0.375" SP 0.500" SP 0.625" SP 0.750" SP

(FPM) Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP

1/6 1240 3612 873 783 675 547 389 158

DX06B 8.2 0.17 7.6 0.17 6.9 0.16 6.4 0.15 5.8 0.14 5.3 0.11

1/4 1437 4185 1011 933 845 750 638 509 347

10.1 0.26 9.5 0.26 9.1 0.25 8.5 0.25 8.0 0.24 7.9 0.22 7.9 0.20

1/6 1240 3804 956 885 803 719 626 509 279

DX08B 10.4 0.16 9.4 0.16 8.6 0.17 8.1 0.17 7.7 0.17 7.4 0.16 6.8 0.14

1/4 1437 4185 1108 1049 979 909 836 756 669

12.5 0.25 11.8 0.25 11.1 0.26 10.5 0.26 9.9 0.26 9.8 0.26 9.8 0.26





TIP FAN CAPACITY - CUBIC FEET PER MINUTE (CFM)

MODEL HP RPM SPEED 0.000" SP 0.125" SP 0.250" SP 0.375" SP 0.500" SP 0.625" SP 0.750" SP 0.875" SP 1.000" SP 1.125" SP

(FPM) Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP

1/4 1093 3943 1884 1768 1639 1496 1329 1111 758

10.2 0.23 9.6 0.24 9.1 0.24 8.3 0.25 7.9 0.26 7.7 0.26 7.7 0.23

1/3 1191 4297 2053 1948 1834 1708 1568 1406 1193 883

DX11B 11.5 0.29 11.0 0.30 10.5 0.31 9.8 0.32 9.0 0.34 8.8 0.34 8.6 0.34 8.6 0.31

1/2 1369 4939 2360 2271 2172 2069 1959 1838 1703 1556 1352 1095

14.0 0.44 13.6 0.46 13.2 0.47 12.8 0.48 12.1 0.48 11.4 0.51 11.0 0.52 10.8 0.52 10.9 0.51 10.9 0.48

3/4 1575 5682 2716 2638 2555 2468 2377 2282 2180 2073 1952 1825

17.4 0.67 17.2 0.69 16.9 0.71 16.6 0.72 16.3 0.73 15.6 0.74 15.0 0.76 14.4 0.78 14.3 0.79 14.3 0.79



TIP FAN CAPACITY - CUBIC FEET PER MINUTE (CFM)

MODEL HP RPM SPEED 0.000" SP 0.125" SP 0.250" SP 0.375" SP 0.500" SP 0.625" SP 0.875" SP 1.000" SP 1.125" SP 1.250" SP

(FPM) Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP

1/4 1039 4318 2027 1894 1737 1597 1422 1219

13.7 0.21 13.2 0.22 12.6 0.24 12.2 0.25 11.7 0.26 11.6 0.26

1/3 1132 4705 2208 2091 1946 1813 1673 1503 1058

DX12B 15.0 0.27 14.4 0.28 13.9 0.30 13.4 0.31 13.0 0.33 12.7 0.34 12.5 0.33

1/2 1302 5411 2540 2439 2319 2195 2082 1963 1668 1503 1280 869

18.1 0.40 17.6 0.42 17.1 0.44 16.6 0.46 16.0 0.48 15.4 0.49 14.7 0.52 14.9 0.52 15.2 0.51 14.5 0.45

3/4 1497 6222 2921 2833 2737 2627 2520 2421 2212 2091 1953 1811

22.0 0.61 21.0 0.63 21.0 0.65 20.0 0.68 19.7 0.71 19.2 0.72 18.1 0.75 17.5 0.77 17.2 0.78 17.3 0.79

Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. FanSizer software automatically calculates drive losses when selecting equipment. The sound

ratings shown are for loudness values in fan sones at 5'0' (1.5m) in a hemispherical free field per AMCA Standard 301. Values shown are for installation Type A: free inlet fan sone levels. Performance ratings do

not include the effects of appurtenances in the airstream. See page 31 for roof curb availability.



24 MM Motors Mounted, complete ready to ship within 24 hours. Available for shipment from Tabor City, NC, Reno, NV & Farnham, Quebec, Canada.



Penn Ventilation • 215.464.8900

DOMEX V-BELT DRIVE 24 MM

TIP FAN CAPACITY - CUBIC FEET PER MINUTE (CFM)

MODEL HP RPM SPEED 0.000" SP 0.125" SP 0.250" SP 0.375" SP 0.500" SP 0.625" SP 0.750" SP 1.000" SP 1.250" SP 1.500" SP

(FPM) Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP

1/4 958 3982 2606 2415 2226 1977 1699 1355

11.8 0.23 11.2 0.24 10.6 0.26 10.0 0.26 8.8 0.26 7.6 0.25

1/3 1044 4339 2840 2662 2499 2292 2044 1788 1445

13.1 0.29 12.6 0.31 12.1 0.33 11.4 0.34 10.7 0.34 9.4 0.34 8.4 0.32

DX14B 1/2 1200 4987 3264 3109 2965 2812 2627 2412 2191 1629

17.3 0.45 16.8 0.46 16.3 0.48 15.8 0.50 15.1 0.52 14.4 0.52 12.9 0.52 10.6 0.49

3/4 1380 5735 3754 3619 3488 3367 3229 3071 2891 2507 2080 699

19.5 0.68 19.1 0.70 18.6 0.72 18.2 0.74 17.8 0.76 17.2 0.78 16.6 0.79 14.9 0.79 13.1 0.76 12.9 0.45

1 1498 6226 4075 3951 3826 3714 3602 3465 3317 2974 2618 2200

22.0 0.87 22.0 0.89 21.0 0.91 21.0 0.93 20.0 0.96 19.8 0.98 19.3 1.00 18.1 1.01 16.3 1.00 14.6 0.97

1/4 694 3395 2889 2677 2450 2212 1707

10.4 0.23 10.0 0.24 9.7 0.26 9.3 0.27 8.8 0.25

1/3 755 3694 3142 2950 2744 2528 2266 1620

11.9 0.30 11.6 0.31 11.1 0.33 10.7 0.34 10.3 0.34 9.7 0.31

1/2 868 4247 3613 3447 3271 3088 2900 2690 2314

DX16B 14.3 0.45 13.9 0.47 13.5 0.49 13.2 0.50 12.8 0.51 12.3 0.52 11.6 0.51

3/4 997 4878 4150 4005 3856 3701 3540 3377 3212 2608

17.4 0.68 17.1 0.70 16.7 0.72 16.4 0.74 16.0 0.76 15.7 0.78 15.2 0.79 13.9 0.77

1 1081 5289 4500 4366 4231 4088 3943 3794 3643 3299 2484

18.9 0.87 18.6 0.89 18.3 0.92 17.9 0.94 17.6 0.96 17.2 0.97 16.8 0.99 15.9 1.01 14.7 0.93

1 1/2 1241 6072 5166 5050 4933 4812 4688 4563 4432 4170 3884 3398

23.0 1.31 23.0 1.34 22.0 1.37 22.0 1.39 22.0 1.42 21.0 1.44 21.0 1.46 20.0 1.50 19.1 1.53 17.8 1.51

1/4 635 3366 3345 3037 2711 2291

10.1 0.22 9.7 0.24 9.1 0.26 8.3 0.26

1/3 691 3663 3640 3360 3062 2751 2162

10.9 0.28 10.5 0.31 10.1 0.33 9.3 0.34 8.5 0.34

1/2 794 4209 4182 3943 3685 3424 3150 2684 1604

14.2 0.43 13.7 0.46 13.2 0.48 12.5 0.50 11.6 0.52 10.6 0.51 10.3 0.41

DX18B 3/4 912 4835 4804 4595 4376 4151 3923 3684 3376 1675

17.1 0.65 16.8 0.68 16.3 0.71 15.8 0.74 15.1 0.76 14.3 0.78 13.4 0.78 12.3 0.59

1 989 5243 5209 5017 4819 4612 4403 4190 3969 3213

19.9 0.82 19.6 0.87 19.2 0.90 18.7 0.92 18.2 0.95 17.5 0.98 16.7 1.00 14.9 0.99

1 1/2 1136 6022 5984 5816 5649 5470 5289 5108 4925 4543 3945 2625

23.0 1.25 23.0 1.30 22.0 1.34 22.0 1.34 22.0 1.37 21.0 1.44 21.0 1.47 19.2 1.52 17.7 1.49 16.8 1.29

2 1252 6637 6595 6443 6291 6134 5970 5806 5641 5307 4958 4399

26.0 1.67 26.0 1.73 26.0 1.78 26.0 1.82 25.0 1.85 25.0 1.88 24.0 1.92 23.0 1.99 22.0 2.05 21.0 2.00

1/4 448 2906 4306 3873 3251 2278

8.6 0.22 7.9 0.25 7.3 0.26 4.7 0.24

1/3 488 3166 4690 4303 3766 3087

9.7 0.28 9.1 0.32 8.4 0.34 6.9 0.33

1/2 561 3640 5392 5075 4650 4142 3517

11.6 0.43 11.0 0.47 10.4 0.49 9.6 0.51 8.2 0.50

DX24B 3/4 645 4185 6200 5926 5601 5196 4747 4226 3466

14.5 0.65 14.0 0.71 13.4 0.73 12.6 0.76 11.9 0.78 10.8 0.76 8.8 0.73

1 700 4541 6728 6477 6191 5847 5450 5031 4531

15.5 0.83 15.0 0.89 14.5 0.93 13.9 0.96 13.3 0.99 12.6 1.00 11.5 0.97

1 1/2 805 5223 7738 7519 7298 7022 6713 6374 6009 5182 3788

19.1 1.27 18.6 1.33 18.1 1.40 17.6 1.42 17.0 1.45 16.5 1.50 15.9 1.51 14.1 1.48 12.0 1.35

2 887 5755 8526 8327 8129 7898 7648 7352 7046 6384 5561 4317

21.0 1.69 21.0 1.77 20.0 1.84 19.7 1.89 19.2 1.91 18.6 1.95 18.1 2.00 17.0 2.04 15.3 1.97 13.9 1.83

1/3 372 2983 5753 5164 4386 3184

8.7 0.27 8.0 0.30 7.4 0.33 6.6 0.32

1/2 428 3432 6619 6120 5514 4747 3627

10.4 0.41 9.7 0.45 9.0 0.49 8.3 0.51 7.4 0.49

3/4 492 3945 7609 7183 6695 6136 5430 4490

13.1 0.62 12.1 0.67 11.0 0.71 10.3 0.76 9.4 0.78 8.7 0.76

1 534 4281 8259 7871 7443 6939 6375 5691 4760

14.7 0.79 13.9 0.85 13.2 0.89 12.4 0.94 11.6 0.98 10.6 1.00 9.5 0.97

DX30B 1 1/2 614 4923 9496 9162 8801 8405 7964 7493 6917 5412

17.4 1.20 16.9 1.27 16.2 1.32 15.6 1.37 14.9 1.43 14.2 1.49 13.2 1.50 10.9 1.47

2 677 5428 10471 10168 9848 9513 9129 8724 8302 7235 5744

19.5 1.61 19.0 1.69 18.6 1.75 18.2 1.80 17.7 1.86 16.9 1.92 16.1 1.99 14.2 2.03 12.5 1.96

3 777 6230 12018 11754 11488 11196 10905 10569 10224 9485 8564 7426

23.0 2.44 22.0 2.53 22.0 2.61 22.0 2.67 21.0 2.73 21.0 2.79 20.0 2.86 18.7 3.01 17.1 3.06 15.5 3.01

5 923 7400 14276 14054 13831 13603 13357 13112 12859 12284 11680 11001

29.0 4.09 29.0 4.19 29.0 4.30 28.0 4.39 28.0 4.46 28.0 4.53 28.0 4.60 27.0 4.75 25.0 4.95 23.0 5.07

Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. FanSizer software automatically calculates drive losses when selecting equipment. The sound

ratings shown are for loudness values in fan sones at 5'0' (1.5m) in a hemispherical free field per AMCA Standard 301. Values shown are for installation Type A: free inlet fan sone levels. Performance ratings do

not include the effects of appurtenances in the airstream. See page 31 for roof curb availability.









24 MM Motors Mounted, complete ready to ship within 24 hours. Available for shipment from Tabor City, NC, Reno, NV & Farnham, Quebec, Canada.







215.464.8900 • Penn Ventilation

DOMEX V-BELT DRIVE 10 QB

TIP FAN CAPACITY - CUBIC FEET PER MINUTE (CFM)

MODEL HP RPM SPEED 0.000" SP 0.125" SP 0.250" SP 0.375" SP 0.500" SP 0.625" SP 0.750" SP 1.000" SP 1.250" SP 1.500" SP

(FPM) Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP

1/2 307 2989 9057 8105 6994

8.0 0.39 7.7 0.46 7.6 0.51

3/4 352 3427 10385 9613 8675 7497

10.6 0.58 10.2 0.65 9.5 0.74 9.1 0.79

1 382 3719 11270 10589 9705 8809 7438

12.4 0.75 12.1 0.82 11.3 0.92 10.6 0.99 9.9 1.00

DX36B 1 1/2 439 4274 12951 12397 11627 10904 10089 8939

16.1 1.13 16.1 1.23 15.4 1.33 14.7 1.43 14.0 1.50 13.1 1.53

2 484 4712 14279 13798 13139 12432 11778 10998 9945

18.8 1.52 18.8 1.63 18.6 1.71 18.0 1.85 17.2 1.95 16.5 2.02 15.8 2.06

3 555 5403 16374 15969 15452 14826 14223 13662 13039 11292

23.0 2.29 23.0 2.43 23.0 2.50 22.0 2.65 22.0 2.80 21.0 2.91 20.0 3.00 18.9 3.09

5 659 6416 19442 19101 18722 18255 17730 17205 16722 15732 14438 12737

29.0 3.83 29.0 4.00 29.0 4.13 29.0 4.22 28.0 4.38 28.0 4.57 27.0 4.74 26.0 4.97 24.0 5.17 23.0 5.10

Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. FanSizer software automatically calculates drive losses when selecting equipment. The sound

ratings shown are for loudness values in fan sones at 5'0' (1.5m) in a hemispherical free field per AMCA Standard 301. Values shown are for installation Type A: free inlet fan sone levels. Performance ratings do

not include the effects of appurtenances in the airstream. See page 31 for roof curb availability.









DOMEX HIGH CAPACITY MODELS 10 QB

TIP FAN CAPACITY - CUBIC FEET PER MINUTE (CFM)

MODEL HP RPM SPEED 0.000" SP 0.125" SP 0.250" SP 0.375" SP 0.500" SP 0.625" SP 0.750" SP 1.000" SP 1.250" SP 1.500" SP

(FPM) Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP

3/4 283 3223 9967 8479 6607

7.6 0.77 7.4 0.78 7.1 0.77

1 308 3508 10847 9497 7905 5889

8.4 0.99 8.1 1.01 7.8 1.00 7.5 0.95

1 1/2 354 4031 12467 11307 10017 8492 6700

9.8 1.49 9.4 1.51 9.0 1.51 8.6 1.49 8.4 1.42

2 390 4441 13735 12682 11565 10299 8785 7013

KB420 11.2 1.98 10.7 2.01 10.3 2.01 10.0 2.00 9.6 1.96 9.5 1.86

3 447 5091 15743 14824 13889 12852 11732 10422 9019

13.2 2.97 12.7 2.99 12.2 3.01 11.8 3.01 11.6 3.00 11.4 2.95 11.3 2.87

5 532 6059 18737 17964 17192 16390 15523 14603 13621 11334

15.9 4.97 15.3 5.01 14.8 5.04 14.2 5.05 13.8 5.04 13.8 5.03 13.7 5.02 13.6 4.87

7 1/2 599 6822 21096 20410 19724 19038 18306 17535 16725 14978 12909

18.5 7.08 17.9 7.12 17.3 7.16 16.7 7.19 16.1 7.19 15.7 7.18 15.7 7.17 15.7 7.13 15.7 6.95

3/4 205 2683 14390 11552 7750

6.8 0.77 6.4 0.78 6.2 0.71

1 225 2945 15794 13298 10237

7.6 1.02 7.3 1.03 7.0 0.99

1 1/2 255 338 17900 15809 13195 10060

8.9 1.49 8.5 1.51 8.1 1.48 7.6 1.39

2 280 3665 19655 17829 15448 13008 9318

JB48 9.9 1.97 9.5 2.00 9.1 1.97 8.6 1.92 8.1 1.72

3 320 4189 22463 20890 18960 16853 14669 11625

12.0 2.94 11.6 2.98 11.1 2.97 10.5 2.93 10.1 2.86 9.7 2.66

5 380 4974 26675 25387 23940 22198 20396 18673 16640

15.1 4.92 14.6 4.97 13.9 4.99 13.2 4.97 12.5 4.92 12.1 4.86 11.9 4.73

7 1/2 430 5629 30185 29048 27829 26419 24867 23270 21783 18188 11780

17.6 7.12 16.9 7.19 16.2 7.23 15.5 7.23 14.7 7.19 14.0 7.13 13.5 7.08 13.4 6.79 13.4 5.65

10 480 6283 33695 32676 31616 30496 29131 27737 26307 23555 20246 15161

20.0 9.91 19.8 9.98 19.7 10.03 19.7 10.07 19.7 10.04 19.7 10.00 19.7 9.93 19.7 9.79 19.7 9.43 19.7 8.45

Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. FanSizer software automatically calculates drive losses when selecting equipment. The sound

ratings shown are for loudness values in fan sones at 5'0' (1.5m) in a hemispherical free field per AMCA Standard 301. Values shown are for installation Type A: free inlet fan sone levels. Performance ratings do

not include the effects of appurtenances in the airstream. See page 31 for roof curb availability.









At Penn Ventilation’s option, large frame motors may be removed after testing and shipped separately.









10 QB Quick Build, 10 day custom build program. Available for shipment from Tabor City, NC & Farnham, Quebec, Canada.







Penn Ventilation • 215.464.8900

Gable Louvers





Dormer Louvers









LOUVERS







Fixed and Adjustable Louvers

Round Louvers

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









WALL LOUVERS









Frame: 18 gauge galvanized steel. edge of each blade to ensure virtual air tightness in the

Blades: 20 gauge roll-formed galvanized steel. closed position.

Features: Louvers are self mulling. Louvers are self- Insect screen: 18/16 aluminum mesh installed in an

flashing and self-framing. No other trim required. extruded removable, re-wireable aluminum frame.

Before painting, louvers are steam-cleaned and treated. Blade Operators: Twin link brackets plated steel

Louvers can be painted to match pre-selected colors by assembled with double brass pivot and set screw.

manufacturer. Standard paint is an electrostatically applied Connecting Rod: 1/4 " zinc plated steel.

polyester paint, 2 mil thick oven baked finish. Operator: Standard operator is by a reinforced cast

For adjustable louvers: After the paint process is aluminum hand crank. OPTIONAL: Chain operator of #35

completed, an extruded weather stripping is applied to the sash chain, with plastic-coated chain pull handle.





Wall Louvers as manufactured by Metallic Products are Fixed louvers feature 45° roll-formed blades, with 4" depth,

specifically designed for pre-engineered metal building wall pan- and riveted to louver frame for security. Fixed louvers have 55%

els. Both fixed and operable models are available. Louvers are self- free area, beginning of water penetration 600 FPM.

flashing requiring no additional flashing to complete installation in Adjustable louvers feature roll-formed blades with plated

standard “R” and “A” type wall panels. Additionally, the frame twin link pivot brackets riveted to blade and connected with 1/4"

design allows the louvers to be installed individually, one above zinc plated rod and assembled with brass pivot and set screw for

the other or side by side, without the need for additional mullions smooth, noncorrosive, long-lasting operation. Standard operator is

or frames. by reinforced cast aluminum hand crank. Louver can be factory or

Modular Louvers are constructed of 18GA. frames and 20GA. field modified for chain operation when louver is installed where

blades, G90 galvanized steel. Frame construction enables easy hand crank is not accessible. Motorized operators are also avail-

installation of single or multiple units interconnected. The self- able. Blade edge seals are installed for maximum air sealing.

flashing frame is designed specifically for either “A” type or “R” Adjustable louvers have 77% free area, beginning of water

type flanges. Please specify panel type when ordering. The frame penetration 500 FPM.

has a recessed head to accept the wall panel and side flanges fit Louvers are available with galvanized finish or can be factory

specified panel profile on 1' modules. The sill is tapered to provide painted utilizing an eletrostatic polyester powder paint and oven

drainage and exclude moisture. Flat flange louvers are also avail-

baked for long lasting and durable finish. Additional materials

able for installation into framed openings. (Note: Self-flashing

available are stainless steel, aluminum and aluminized zinc. All

louvers can be made to fit framed openings if specified when

louvers are shipped with an 18/16 aluminum insect screen mounted

ordering.) All welds are water tight and made from noncorroding

in a removable, rewireable frame. Hardware cloth is also available.

siliconized bronze wire and finished after fabrication.

louvers are shipped individually in heavy duty cardboard cartons.

7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com

SL-01 / Rev. 2/01

13⁄ 4"

41⁄ 8"

11⁄ 2" COVER









VERTICAL SECTION

WITH R PANEL JAMB

SCREEN









NOMINAL

11⁄ 2"



ELEVATION

13⁄ 4"

OPERATOR

45⁄ 8"









VERTICAL SECTION - FIXED BLADES

SCREEN HORIZONTAL SECTION









WITH A PANEL JAMB

SEE JAMB TYPES BELOW

SCREEN



11⁄ 4"

11⁄ 2" 11⁄ 2"



13⁄ 8" ⁄ 8"

7



1⁄ 4"

3⁄ 4" 7

⁄ 8"

NOMINAL NOMINAL NOMINAL



A PANEL R PANEL FLAT FLANGE

JAMB TYPES

1⁄ 4"









NOTE: Any combination

NOMINAL









NOMINAL









of head and sill types

can be ordered.

SELF-FLASHING FLAT FLANGE

HEADER TYPES

NOMINAL









NOMINAL









1⁄ 4"





SELF-FLASHING FLAT FLANGE MULTI-UNIT INSTALLATION

SILL TYPES (SELF MULLING)



METALLIC PRODUCTS • Houston, Texas 77040

(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746

SL-02/1 / Rev. 3/94

SL-02/2 / Rev. 06/00

POWDER PRODUCTS INC.









SL-03/1 / Rev. 2/01

POWDER PRODUCTS INC.









SL-03/2 / Rev. 2/01

DATE:



TITLE:

SECTION

7777 Hollister Road

DRAWINGS

PART:



Houston, TX 77040 LOUVER

(713) 856-9696 • 1-800-356-7746

E-mail: info@mpvent.com FREE-FLOW

SL-01.1 / Rev. 2/01

GALVANIZED STEEL STATIONARY LOUVER



Standard Construction Frame Features

4" deep 18 gauge galvanized steel * Architecturally styled

* All galvanized steel construction

Blade Options

20 gauge galvanized steel, 45° angle, spaced 39⁄16"

Changes to the basic design of this louver are

center to center

available at additional cost. They include:

Screen 1. Extended sill

Expanded 18-16 aluminum insect screen in 2. A variety of bird or insect screen

3. Selection of finishes: Baked enamel, polyurethane

removable frame. 4. Mullions if needed

Finish (Not for A Panel or R Panel Type)

Mill









HEADER TYPES

1/4"

NOMINAL NOMINAL







SILL TYPES

NOMINAL NOMINAL

1/4"

SELF FLASHING FLAT FLANGE



A DIM

JAMB TYPES

A PANEL R PANEL FLAT FLANGE

B DIM









1 1/4" NOMINAL 1 1/2" NOMINAL 1/4" NOMINAL









ORDERING INFORMATION

Circle Panel Type Above

QTY. A DIM B DIM OPTIONS SIDE

PROFILE

NOTE:

MINIMUM SIZE IS 12" X 12"



DATE:

4/22/97

6/27/00

TITLE:

FLAT SKIRT

GALVANIZED

7777 Hollister

APPLICATION

STEEL

PART:



Houston, TX 77040 STATIONARY

RIDGE VENT

(713) 856-9696 • 1-800-356-7746 LOUVER

E-mail: info@mpvent.com

CV-04 / Rev. 00/00

SL-01.3 / Rev. 06/00

GALVANIZED STEEL FIXED LOUVER

WITH STORM-PROOF BLADES

Standard Construction Frame Features

4" deep 18 gauge galvanized steel * Architecturally styled

* All galvanized steel construction

Blade • Blade and Jamb Seals

20 gauge galvanized steel Options

Screen Changes to the basic design of this louver are

18-16 aluminum insect screen in removable frame. available at additional cost. They include:

1. Extended sill

Finish 2. A variety of bird or insect screen

Mill 3. Selection of finishes: Baked enamel or epoxy color

match.( )









HEADER TYPES

1/4"

NOMINAL NOMINAL







SILL TYPES

NOMINAL NOMINAL

1/4"

SELF FLASHING FLAT FLANGE







A DIM

JAMB TYPES

A PANEL R PANEL FLAT FLANGE

B DIM









1 1/4" NOMINAL 1 1/2" NOMINAL 1/4" NOMINAL

BLADE

PROFILE

ORDERING INFORMATION

Circle Panel Type Above

Indicate FINISH in Options Above SIDE

QTY. A DIM B DIM OPTIONS PROFILE

NOTE:

MINIMUM SIZE IS 12" X 12"



DATE:

4/22/97

6/27/00

TITLE:

FLAT

STEEL SKIRT

7777 Hollister Road

APPLICATION

LOUVER

PART:



Houston, TX 77040 STORM-PROOF

RIDGE VENT

(713) 856-9696 • 1-800-356-7746 BLADES

E-mail: info@mpvent.com

CV-04 / Rev. 00/00

SL-01.4 / Rev. 06/00

GALVANIZED STEEL FIXED GABLE LOUVER



Standard Construction Frame Features

4" deep formed 18 gauge galvanized steel * Architecturally styled



Blade Options

20 gauge galvanized steel, 45° angle, spaced 3 ⁄16"9 Changes to the basic design of this louver are

between blades available at additional cost. They include:

1. A variety of bird or insect screen

Flange Type 2. Selection of finishes: Baked enamel, polyurethane

Flat flange ( )

3. Sheeted above and below

Screen 4. Sheeted below only

Expanded aluminum birdscreen

Finish

Mill









3"

1 1/2"



BACK VIEW









ACCORDING TO PITCH









BASE DIMENSION



FRONT VIEW









ORDERING INFORMATION

Indicate FINISH in Options Above BLADE PROFILE SIDE PROFILES

QTY. BASE PITCH OPTIONS









DATE:

4/22/97

6/27/00

TITLE:

FLAT SKIRT

GALVANIZED

7777 Hollister

APPLICATION

STEEL

PART:



Houston, TX 77040 FIXED VENT

RIDGE

(713) 856-9696 • 1-800-356-7746 GABLE LOUVER

E-mail: info@mpvent.com

00/00

CV-04 / Rev. 06/00

AL-02

ALUMINUM STATIONARY STORMPROOF BLADE LOUVER



Standard Construction Frame Features

4" deep formed .080 aluminum * Architecturally styled

* All aluminum construction for low maintenance and

Blade high resistance to corrosion

Extruded aluminum.080 J type blade, 45° angle, Options

spaced 4" center to center Changes to the basic design of this louver are

Screen available at additional cost. They include:

Expanded 18-16 aluminum insect screen in remov- 1. Extended sill

2. A variety of bird or insect screen

able frame 3. Selection of finishes: Baked enamel, polyurethane

Finish or anodized.( )

Mill 4. Mullions if needed

(Not for A panel or R panel type)









HEADER TYPES

1/4"

NOMINAL NOMINAL







SILL TYPES

NOMINAL NOMINAL

1/4"

JAMB TYPES SELF FLASHING FLAT FLANGE

A PANEL R PANEL FLAT FLANGE

A DIM

B DIM









1 1/4" NOMINAL 1 1/2" NOMINAL 1/4" NOMINAL

BLADE

PROFILE

ORDERING INFORMATION

Circle Panel Type Above SIDE

Indicate FINISH in Options Above

PROFILE

QTY. A DIM B DIM OPTIONS



NOTE:

MINIMUM SIZE IS 12" X 12"



DATE:

4/22/97

6/27/00

TITLE:

FLAT SKIRT

ALUMINUM

7777 Hollister Road

APPLICATION

STATIONARY

PART:



Houston, TX 77040 STORMPROOF

RIDGE VENT

(713) 856-9696 • 1-800-356-7746 BLADES

E-mail: info@mpvent.com

CV-04 / Rev. 00/00

SL-01.5 / Rev. 06/00

ALUMINUM STATIONARY LOUVER

WITH DRAINABLE BLADES

Standard Construction Frame Features

* Architecturally styled

4" deep formed .080 aluminum * All aluminum construction for low maintenance and

Blade high resistance to corrosion

Drainable extruded aluminum .080 J type blade, 45° Options

angle, spaced 4" center to center Changes to the basic design of this louver are

Screen available at additional cost. They include:

1. Extended sill

Expanded 18-16 aluminum insect screen in 2. A variety of bird or insect screen

removable frame. 3. Selection of finishes: Baked enamel, polyurethane

Finish or anodized.( )

Mill 4. Mullions needed for continuous run









HEADER

1/4"

NOMINAL







SILL



NOMINAL



1/4"

FLAT FLANGE





A DIM

B DIM









JAMB BLADE

PROFILE



ORDERING INFORMATION

Indicate FINISH in Options Above

QTY. A DIM B DIM OPTIONS

SIDE

PROFILE

NOTE:

MINIMUM SIZE IS 12" X 12"



DATE:

4/22/97

6/27/00

TITLE:

FLAT SKIRT

ALUMINUM

7777 Hollister Road

APPLICATION

STATIONARY

PART:



Houston, TX 77040 DRAINABLE

RIDGE VENT

(713) 856-9696 • 1-800-356-7746 BLADE

E-mail: info@mpvent.com

CV-04 / Rev. 00/00

SL-01.6 / Rev. 06/00

ALUMINUM FIXED GABLE LOUVER



Standard Construction Frame Features

3" deep formed .080 aluminum * Architecturally styled

* All aluminum construction for low maintenance and

Blade high resistance to corrosion

Extruded aluminum .080 J type blade, 45° angle, Options

spaced 33⁄4" between blades Changes to the basic design of this louver are

Flange Type available at additional cost. They include:

Flat flange 1. A variety of bird or insect screen

2. Selection of finishes: Baked enamel, polyurethane

Screen or anodized ( )

Expanded aluminum birdscreen 3. Sheeted above and below

4. Sheeted below only

Finish

Mill









3"

1 1/2"



BACK VIEW









ACCORDING TO PITCH









BASE DIMENSION



FRONT VIEW









ORDERING INFORMATION

Indicate FINISH in Options Above BLADE PROFILE SIDE PROFILES

QTY. BASE PITCH OPTIONS









DATE:

4/22/97

6/27/00

TITLE:

FLAT SKIRT

ALUMINUM

7777 Hollister Road

APPLICATION

PART:



Houston, TX 77018 FIXED VENT

RIDGE

(713) 856-9696 • 1-800-356-7746 GABLE LOUVER

E-mail: info@mpvent.com

00/00

CV-04 / Rev. 06/00

AL-03

ALUMINUM ROUND LOUVER

WITH STORM-PROOF BLADES

Standard Construction Frame Features

3" deep formed .080 aluminum * Architecturally styled

* All aluminum construction for low maintenance and

Blade high resistance to corrosion

Extruded aluminum .080 J type blade, 45° angle, Options

spaced 4" center to center Changes to the basic design of this louver are

Screen available at additional cost. They include:

Expanded aluminum birdscreen 1. A variety of bird or insect screen

2. Selection of finishes: Baked enamel, polyurethane

Finish or anodized ( )

Mill 3. Mullions if needed









WEATHER BAND









LOUVER









BLADE PROFILE





SIDE PROFILE

ORDERING INFORMATION

Indicate PANEL TYPE for weather band

QTY. DIAMETER PANEL TYPE OPTIONS



NOTE:

MINIMUM SIZE IS 24" DIAMETER



DATE:

4/22/97

6/27/00

TITLE:

FLAT SKIRT

ALUMINUM

7777 Hollister Road

APPLICATION

ROUND LOUVER

PART:



Houston, TX 77040 STORM-PROOF

RIDGE VENT

(713) 856-9696 • 1-800-356-7746 BLADES

E-mail: info@mpvent.com

00/00

CV-04 / Rev. 6/00

AL-01

INSTALLATION INSTRUCTIONS FOR

ALUMINUM ROUND LOUVER









LOUVER WEATHER BAND SHEETS HOLE









1. CUT HOLE IN SHEET

2. PUT WEATHER BAND IN OPENING

3. SCREW WEATHER BAND TO SHEETS AND CAULK

4. PUT LOUVER INSIDE WEATHER BAND

5. SCREW LOUVER TO WEATHER BAND









DATE:

4/22/97

6/27/00

TITLE:

FLAT SKIRT

ALUMINUM

7777 Hollister Road

APPLICATION

ROUND LOUVER

PART:



Houston, TX 77040 INSTALLATION

RIDGE VENT

(713) 856-9696 • 1-800-356-7746 INSTRUCTIONS

E-mail: info@mpvent.com

CV-04 / Rev. 00/00

AL-01.1 / Rev. 06/00

DATE:



TITLE:

CHAIN PULL

7777 Hollister Raod

INSTA LLATION

PART:



Houston, TX 77040 LOUVER

(713) 856-9696 • 1-800-356-7746

E-mail: info@mpvent.com VARI-FLOW

SL-01.2 / Rev. 2/01

ADJUSTABLE GALVANIZED STEEL BACK PIVOT LOUVER



Standard Construction Frame Finish

4" deep 18 gauge galvanized steel channel type Mill



Blade Features

9 * Architecturally styled

20 gauge galvanized steel, 85° and spaced 3 ⁄16" * All galvanized steel construction

center to center * Blade and jamb seals

Operator Type Options

Hand Crank Changes to the basic design of this louver are

Screen available at additional cost. They include:

1. Extended sill

18-16 aluminum insect screen in removable frame. 2. A variety of bird or insect screen

3. Selection of finishes: Baked enamel, polyurethane

color match.( )

4. Pull Chain Operators available

5. Motor available

6. Mullions if needed

(Not for A panel or R panel type)







HEADER TYPES

1/4"

NOMINAL NOMINAL





SILL TYPES

NOMINAL NOMINAL



1/4"

SELF FLASHING FLAT FLANGE



A DIM

JAMB TYPES

A PANEL R PANEL FLAT FLANGE

B DIM









1 1/4" NOMINAL 1 1/2" NOMINAL 1/4" NOMINAL









ORDERING INFORMATION

Circle Panel Type Above

Indicate FINISH in Options Above

SIDE

QTY. A DIM B DIM OPTIONS

PROFILE

NOTE:

MINIMUM SIZE IS 12" X 12"



DATE:

4/22/97

6/27/00

TITLE:

FLAT SKIRT

GALVANIZED

7777 Hollister Road

APPLICATION

STEEL

PART:



Houston, TX 77040 BACK PIVOT

RIDGE VENT

(713) 856-9696 • 1-800-356-7746 LOUVER

E-mail: info@mpvent.com

CV-04 / Rev. 00/00

SL-01.7 / Rev. 06/00

ADJUSTABLE GALVANIZED STEEL CENTER PIVOT LOUVER



Standard Construction Frame Finish

4" deep 18 gauge galvanized steel channel type Mill



Blade Features

9 * Architecturally styled

20 gauge galvanized steel, 45° and spaced 3 ⁄16" * All galvanized steel construction

center to center * Blade and jamb seals

Operator Type Options

Hand Crank Changes to the basic design of this louver are

Screen available at additional cost. They include:

1. Extended sill

18-16 aluminum insect screen in removable frame. 2. A variety of bird or insect screen

3. Selection of finishes: Baked enamel, polyurethane

color match.( )

4. Pull Chain Operators available

5. Motor available

6. Mullions if needed

(Not for A panel or R panel type)







HEADER TYPES

1/4"

NOMINAL NOMINAL





SILL TYPES

NOMINAL NOMINAL



1/4"

SELF FLASHING FLAT FLANGE



A DIM

JAMB TYPES

A PANEL R PANEL FLAT FLANGE 3 9/16"

B DIM









1 1/4" NOMINAL 1 1/2" NOMINAL 1/4" NOMINAL









ORDERING INFORMATION

Circle Panel Type Above 4"

Indicate FINISH in Options Above

QTY. A DIM B DIM OPTIONS SIDE

PROFILE

NOTE:

MINIMUM SIZE IS 12" X 12"



DATE:

4/22/97

6/27/00

TITLE:

FLAT SKIRT

GALVANIZED

7777 Hollister Road

APPLICATION

STEEL

PART:



Houston, TX 77040 CENTER PIVOT

RIDGE VENT

(713) 856-9696 • 1-800-356-7746 LOUVER

E-mail: info@mpvent.com

CV-04 / Rev. 00/00

SL-01.8 / Rev. 06/00

ADJUSTABLE GALVANIZED STEEL CENTER PIVOT

CHANNEL TYPE LOUVER

Standard Construction Frame Finish

4" deep 18 gauge galvanized steel channel type Mill



Blade Features

9 * Architecturally styled

20 gauge galvanized steel, 45° and spaced 3 ⁄16" * All galvanized steel construction

center to center * Blade and jamb seals

Operator Type Options

Hand Crank Changes to the basic design of this louver are

Screen available at additional cost. They include:

1. Extended sill

18-16 aluminum insect screen in removable frame. 2. A variety of bird or insect screen

3. Selection of finishes: Baked enamel, polyurethane

color match.( )

4. Mullions needed for continuous run

5. Pull Chain Operators available

6. Motor available









3/4"





3/4"





1 9/16"









A DIM





4" MULLION 3 9/16"

B DIM









4" MULLION









ORDERING INFORMATION 4"

Indicate FINISH in Options Above

QTY. A DIM B DIM OPTIONS SIDE

PROFILE

NOTE:

MINIMUM SIZE IS 12" X 12"



DATE:

4/22/97

6/27/00

TITLE:

FLAT SKIRT

GALVANIZED

7777 Hollister Road

APPLICATION

STEEL

PART:



Houston, TX 77040 CENTER PIVOT

RIDGE VENT

(713) 856-9696 • 1-800-356-7746 CHANNEL TYPE

E-mail: info@mpvent.com

CV-04 Rev. 06/00

SL-01.9 / / Rev. 00/00

ADUSTABLE ALUMINUM STORMPROOF BLADE LOUVER



Standard Construction Frame Features

4" deep formed .080 aluminum * Architecturally styled

* All aluminum construction for low maintenance and

Blade high resistance to corrosion

Extruded aluminum.080 J type blade, 45° angle, Options

spaced 4" center to center Changes to the basic design of this louver are

Screen available at additional cost. They include:

Expanded 18-16 aluminum insect screen in remov- 1. Extended sill

2. A variety of bird or insect screen

able frame 3. Selection of finishes: Baked enamel, polyurethane

Finish or anodized.( )

Mill 4. Mullions if needed

(Not for A panel or R panel type)









HEADER TYPES

1/4"

NOMINAL NOMINAL







SILL TYPES

NOMINAL NOMINAL

1/4"

JAMB TYPES SELF FLASHING FLAT FLANGE

A PANEL R PANEL FLAT FLANGE

A DIM

B DIM









1 1/4" NOMINAL 1 1/2" NOMINAL 1/4" NOMINAL

BLADE

PROFILE

ORDERING INFORMATION

Circle Panel Type Above

Indicate FINISH in Options Above

SIDE

QTY. A DIM B DIM OPTIONS PROFILE

NOTE:

MINIMUM SIZE IS 12" X 12"



DATE:

2/20/014/22/97

TITLE:

T

FLA SKIRT

ADJUSTABLE

T

APPLICAION

ALUMINUM

7777 Hollister Road PART:



Houston, TX 77040 STORMPROOF

RIDGE VENT

(713) 856-9696 1-800-356-7746 BLADE

E-mail: info@mpvent.com

CV-04 Rev. 00/00

SL-01.10 // Rev. 06/00

Standard Cupola

Deluxe Cupola







Cupolas









Stamped Cupola

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









DELUXE CUPOLA









Standard Size Screen

Standard sizes include: Hardware cloth

2' wide x 2' long x 2'-0" high 18/16 Insect screen

3' wide x 3' long x 3'-0" high

4' wide x 4' long x 4'-0" high

Construction Options

The sides of the cupola are .080 aluminum with mitered and Optional weather vanes are available

welded blades at a 45 degree angle. The tops are made of Insulation for the roof curb

.050 aluminum. The cupola is placed on a roof curb of 16 Two tone colors

gauge aluminized zinc with minimum of 6" high side.









CURB TYPES









Hillside Curb Peak Curb



7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com

SI-02 / Rev. 2/01

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









STAMPED CUPOLA









Standard Size Screen

Standard sizes include: Hardware cloth

2' wide x 2' long x 2'-0" high 18/16 Insect screen

3' wide x 3' long x 3'-0" high

4' wide x 4' long x 4'-0" high

Construction

The sides of the cupola are 26 gauge galvalume or Options

“precoated material.” The material is then stamped with 2 Weather vanes are available

rows of 4" wide louvers. The tops are made of 22 gauge Insulation for the roof curb

material. The cupola is placed on a roof curb of 16 gauge Two tone colors

aluminized zinc with minimum of 6" high side.









CURB TYPES









Hillside Curb Peak Curb



7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com

SI-03 / Rev. 2/01

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









STANDARD CUPOLA









Standard Size Screen

Standard sizes include: 2 Mesh Birdscreen

2' wide x 2' long x 2'-0" high 18/16 Insect screen

3' wide x 3' long x 3'-0" high

4' wide x 4' long x 4'-0 high



Construction Options

The sides of the cupola are constructed of 45 degree fixed Weather vanes

louver blades. Coupolas are designed to be installed on Insulation for the roof curb

roof curbs. Please specify type and roof slope when order- Two tone colors

ing. Operable Louver Blades









CURB TYPES









Hillside Curb Peak Curb



7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com

SI-06 / Rev. 8/01

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









ROOF CURBS…









...used on all types of metal roofing systems and conform to MP’s high standards and specifications which have

been developed, tested and proven over many years.

Construction: water penetration. Hillside mounted curbs have a water

Rugged, 16 gauge 55% aluminum-zinc coated sheet meets diverting angle to deflect water around the unit. A cricket

ASTM A792-89. Corners are mitered and welded water can be substituted for the diverter angle if desired. Hillside

tight using a siliconized bronze wire for a long lasting and mounted curbs can also be constructed utilizing a two-

non-corrosive finish. Welds are finished with a protective piece design with a separate under-panel diverter to achieve

zinc primer. FSK faced rigid board insulation is optional. shingling effect without the need to cut into roof panels.

Design: Finish:

Curbs are made to match any roof slope and can be either Curbs are supplied with a 55% aluminum-zinc finish and

peak or hillside mounted. Curb corrugations match virtually can be factory painted to match almost any color.

any available roof configuration and can be factory welded Ordering:

into curb skirts or shipped loose for field installation. “R” When ordering, please indicate size, roof panel type,

panel configurations can be die-formed directly into curb whether or not insulated, and roof slope. Convenient order

skirts to reduce the amount of welding and the possibility of forms available upon request.









Roof curbs manufactured by Metallic Products for the metal weather tightness by utilizing the curbs integral flange to mesh

roofing market are in accordance with the highest design require- with the roof panels. Curbs can mesh with any metal roof panel

ments and specifications. and are made to match specified roof slope either hillside or peak

Roof curbs are constructed of 16 gauge galvalume sheet to mounted. Standard diverter angles keep water away from equip-

provide the ultimate in strength for any roof-top accessory ment and crickets are available as an option.

including A/C units, fans, skylights, refrigeration units, pipes, Curbs can be insulated to prevent energy loss and can also be

stacks, etc... factory painted to match any metal roof color to perfectly blend

Curbs also provide a level mounting surface for mechanical in to any architectural application.

equipment to insure their long life and additionally provide



7777 Hollister Rd Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com

RC-01 / Rev. 2/01

END CAPS – RIB PROFILE









IB

OR R

ROOF CURB

NOTCHED FOR PANEL RIBS

MAJ

L F

⁄4"

C O

2 3⁄4" 2 3









Note: Sealant Tape Must Be Applied

to All Four Sides

3"



NOTE:

Field Notch Skirt for

Lower Edge Ribs.

END CAP

(OVER PANEL)



SEALANT TAPE







Structure -

Not by M.P.

RIBBED ROOF PANEL SEALANT

PREPARED FOR CURB LOWER EDGE DETAIL TAPE







CURB DIM. O/D CURB ROOF PANEL SIDE DETAIL

11⁄2" OPENING DIM. 11⁄2" OPENING 11⁄2"



4"

SEALANT TAPE



END CAP

(UNDER PANEL)

3"

Structure - 6" 3"

Not by M.P. 9" Structure -

3" 3" STD.

Not by M.P. SEALANT TAPE

6"

STD. SECTION THRU ROOF SLOPE SECTION @ SIDE UPPER EDGE DETAIL

DATE:

9/95

TITLE:

INSTALLATION

7777 Hollister Road PART:

INSTRUCTIONS

Houston, TX 77040 ROOF CURB

(713) 856-9696 • 1-800-356-7746

E-mail: info@mpvent.com MPD-25

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









ROOF CURBS

WHY A ROOF CURB AND NOT A SIMPLE ROOF PENETRATION?

Let’s start with a definition of what a roof curb is:

A roof curb is a structure that creates a level surface on a sloped roof for mounting and supporting

roof top equipment while retaining weather tightness.





1)STRUCTURAL STRENGTH: The curb is made of 16GA. welded steel. Each curb can hold

thousands of pounds. Also, the curb is usually supported with a “red iron” package so the curb

becomes part of the structure of the building and not just a cap that sits unsupported on the roof

sheets. Together, the curb and the support form a strength not found by just setting the equipment

on the roof without a curb.



2)WEATHER TIGHTNESS: The sides of the curb become an integral part of the roof itself. The curbs

mesh with the roof sheets to form a weather tight barrier. In other words, the flanges of the curb are

a part of the roof sheets. Also, these curbs have a water diverter angle to shed water around the curb

and away from your rooftop equipment.



3)LEVEL MOUNTING SURFACE: As curb manufacturers, we rarely know what equipment will be

mounted on our curbs. Usually, some type of motorized equipment is used; a fan, an air conditioner,

an exhaust unit, a refrigeration unit, or a ventilator. Almost all motorized equipment is designed to

work from a level mounting surface.



4)INSULATION: Optional 1 1/2" - 3lb density fiberglass insulation









7777 Hollister Rd Houston, Texas 77040 · Phone: 713.856.96964 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com

RC-02 / Rev. 2/01

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









FABRICATED METAL BUILDING ROOF CURBS

1 – GENERAL

A – The general conditions and supplemental general conditions of the contract apply to this

section as if completely written herein.

B – The General Contractor shall provide all labor, material and equipment to completely install

fabricated metal roof curbs.

C – Fabricated metal roof curbs shall be used at all roof penetrations including, but not limited to,

HVAC units, skylights, duct openings, pipe penetrations, column penetrations, and exhaust

fans.



2 – PRODUCTS

A – Fabricated metal roof curbs shall be models MP-RC (specify #1 #2, #3, #4, #5, #6 or #7) as

manufactured by:

METALLIC PRODUCTS , 7777 Hollister Road, Houston, Texas 77040, (713) 856-9696.



3– CONSTRUCTION

A – Curbs shall be constructed of 16 gauge galvanized steel,

(to 10 gauge depending on loading), with fully mitered and

welded corners, integral base plates, factory insulated with

11Ú thick aluminum faced 3 pound density fiberglass insulation,

2"



with water diverter angle.

B – Standard height of curb shall be 8" above finished roof (or as specified).

C – Curbs shall be constructed to match slope of roof and provide a level top surface for mounting

of mechanical equipment.

D – Additional Options

1 – Galvalume Construction 5 – Neoprene Foam Gasket

2 – Aluminum Construction 6 – Extended Base Plate

3 – Treated Nailers 7 – Temporary Cover

4 – Solid Top





4 – INSTALLATION

A – Curbs shall be installed in strict accordance with manufacturers printed instructions and as

detailed on the drawings.









7777 Hollister Rd Texas 7

Houston, 7040 Phone:713.856.96964 Fax: 713.856.9686 1. 800.356.7746 m

Email: info@mpvent.co www.mpvent.com

RC-03/1 / Rev. 2/01

Metallic Products

SLOPE MOUNT, TWO PIECE CONSTRUCTION

Customer: ROOF CURB

Shingle Type, Field Located

MP-RC1



STANDARD FEATURES

1. 16 gauge galvanized steel shell and baseplate

2. Corners mitered and welded watertight

3. Welds prime painted after fabrication

Ship To:

4. Internal angle reinforcing when specified

5. Water diverter angle

6. 6" minimum height on ridge side

7. 1-1/2" – 3# density insulation when specified





Order No.:

ADDED OPTIONS

Job No.: 1.

2.

Order Date:

3.

Due Date: MATCH ROOF PANEL______________________









NO. REQ'D DIM. A DIM.B H L DIM.C DIM.D TAG DESCRIPTION









Page ______ of _______ METALLIC PRODUCTS • Houston, Texas 77040

RC-1 / Rev. 2/01 (713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746

INSTALLATION INSTRUCTIONS for MP-RC1

TWO PIECE CONSTRUCTION TO BE INSTALLED ON

COMPLETED ROOF DECK









A. B.

1. Using curb ribs as a guide, layout and mark roof open- 3. Apply wide tape caulk to diverter plate top sides and

ings on completed roof deck as outside curb width by upper edge.

outside curb length plus 9" for diverter plate. 4. Align diverter plate ribs with roof deck ribs and slide

2. Cut openings in roof panel and install support framing diverter plate beneath roof panel.

for roof curb and equipment loads. Support at least two 5. Fasten diverter plate to roof panel and sub-framing

parallel curb walls. Avoid cantilever sections over 1' in using suitable fasteners compatible with roof system. A

length. minimum of four fasteners per side spaced on 3" centers

or less as roof system permits. Fasteners should withstand

a minimum pullout force of 150# each.









C. D.

6. Apply continuous tape caulk at least 2 -1/2" wide around 9. Inspect all joints and fasteners in curb flanges. Caulk

remaining roof opening. diverter plate and roof curb flanges to seal out moisture.

7. Position curb so that corrugation on curb flanges mate 10. Apply a closed cell neoprene strip to top rail of roof

on top of corresponding corrugations of roof panel on eave curb before setting a rooftop unit. Equipment should be

side of opening. fastened directly to curb wall using compatible fasteners.

8. Fasten curb to roof panel and diverter plate in accor-

dance with step 5.

MP-RC1

Metallic Products

RIDGE MOUNT ROOF CURB

Customer:

Factory Installed Corrugation

MP-RC2



STANDARD FEATURES

1. 16 gauge galvanized steel shell and baseplate

2. Corners mitered and welded watertight

3. Welds prime painted after fabrication

Ship To: 4. Internal angle reinforcing when specified

5. Water diverter angle

6. 6" minimum height on ridge side

7. 1-1/2" – 3# density insulation when specified





Order No.: ADDED OPTIONS

1.

Job No.:

2.

Order Date: 3.

MATCH ROOF PANEL______________________

Due Date:









NO. REQ'D DIM. A DIM.B DIM.C H L TAG DESCRIPTION









Page ______ of _______ METALLIC PRODUCTS • Houston, Texas 77040

RC-2 / Rev. 2/01 (713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746

INSTALLATION INSTRUCTIONS for MP-RC2

FOR INSTALLATION OVER ROOF PANELS









A. B.

1. On fully sheeted roof, locate and mark center line of roof 3. Cut out roof opening to I.D. of curb, plus an additional 1-

opening on ridge. 1/2" of the major ribs on the eave sides of the opening to

2. Using distance from center line to major ribs as a guide, allow the curb to seal to flat of roof deck.

layout and mark roof opening to curb inside dimensions. 4. Install structural support framing for roof curb and

equipment loads beneath roof curb and equipment loads

beneath roof curb walls and flanges around opening. Keep

I.D. clear.









C. D.

5. Turn roof curb upside down and apply tape caulk to curb 7. Seal edge of roof curb flange with silicone caulk to

flanges. assure watertight weather seal.

6. Press the curb in place on the roof deck. Fasten curb to 8. Apply a closed cell neoprene strip to top rail of roof curb

support steel through curb flange and roof deck using before setting a rooftop unit. Equipment should be fas-

suitable fasteners compatible\with roof system. A minimum tened directly to curb wall using compatible fasteners.

of four fasteners per side spaced on 3" centers or less as

roof system permits. Fasteners should withstand a mini-

mum pullout force of 150# each.





RC-2/2

Metallic Products

RIDGE MOUNT ROOF CURB

Customer: No Corrugation

MP-RC3



STANDARD FEATURES

1. 16 gauge galvanized steel shell and baseplate

2. Corners mitered and welded watertight

3. Welds prime painted after fabrication

4. Internal angle reinforcing when specified

Ship To: 5. Water diverter angle

6. 6" minimum height on ridge side

7. 1-1/2" – 3# density insulation when specified





ADDED OPTIONS

Order No.: 1.

Job No.: 2.

3.

Order Date:

Due Date:









NO. REQ'D O.D. DIM. H L TAG DESCRIPTION









Page ______ of _______ METALLIC PRODUCTS • Houston, Texas 77040

RC-3 / Rev. 2/01 (713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746

INSTALLATION INSTRUCTIONS for MP-RC3

RIDGE MOUNT ROOF CURBS

To Be Installed Beneath Roof Deck









A. B.

1. After building framing is complete, locate roof opening 3. Cut roof panels to fit snugly around curb walls.

and install support framing for roof curb and equipment 4. Apply a wide band of tape caulk to top side of curb

loads. flanges.

2. Set and secure roof curb in place on support framing. At 5. Install and seal closure strips as required. Press roof

least two parallel curb walls must be on support framing. panels into position.

Loads shall not be supported by a cantilever section

exceeding 1' in length.









C. D.

6. Fasten roof panel through curb flanges to support steel 7. Inspect installation and fasteners. Apply silicone sealant

using suitable fasteners compatible with roof system. A to seal seams around all sides of curb to assure a water-

minimum of four fasteners per side spaced on 3" centers tight seal.

or less as roof system permits. Fasteners should withstand 8. Apply a closed cell neoprene strip to top rail of roof curb

a minimum pullout force of 150# each. before setting a rooftop unit. Equipment should be fas-

tened directly to curb wall using compatible fasteners.









RC-3/2

Metallic Products

SLOPE MOUNT ROOF CURB

Customer:

Over Panel Installation, Shop Located, Factory

Installed Corrugation

MP-RC4



STANDARD FEATURES

1. 16 gauge galvalume steel shell and baseplate

2. Corners mitered and welded watertight

Ship To: 3. Welds prime painted after fabrication

4. Additional reinforcing when specified

5. Water diverter

6. 6" minimum height on ridge side

7. 1-1/2 " 3# density insulation when specified



Order No.: ADDED OPTIONS

1.

Job No.:

2.

Order Date: 3.

MATCH ROOF PANEL

Due Date:









NO. REQ'D DIM. A DIM.B DIM.C H L TAG DESCRIPTION









Page ______ of _______ METALLIC PRODUCTS • Houston, Texas 77040

RC-4 / Rev. 2/01 (713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746

INSTALLATION INSTRUCTIONS for MP-RC4

FOR INSTALLATION OVER ROOF PANELS









A. B.

1. On fully sheeted roof, locate and mark center line of roof 3. Cut out roof opening to O.D. of curb, plus an additional

opening. 6" of the major ribs on the ridge side of the opening to

2. Using distance from center line to major ribs as guide, allow the curb's water diverter area to seal to flat of roof

layout and mark roof opening to curb outside dimensions. deck.

4. Install structural support framing for roof curb and

equipment loads beneath roof curb walls and flanges

around opening. Keep I.D. clear.









C. D.

5. Turn roof curb upside down and apply tape caulk to curb 7. Seal edge of roof curb flange with silicone caulk to

flanges. assure watertight weather seal.

6. Press the curb in place on the roof deck. Fasten curb to 8. Apply a closed cell neoprene strip to top rail of roof curb

support steel through curb flange and roof deck using before setting a rooftop unit. Equipment should be fas-

suitable fasteners compatible with roof system. A minimum tened directly to curb wall using compatible fasteners.

of four fasteners per side spaced on 3" centers or less as

roof system permits. Fasteners should withstand a mini-

mum pullout force of 150# each.





RC-4/2

Metallic Products

SLOPE MOUNT ROOF CURB

Customer: Shop Located, Shingle Type, Factory Installed

Corrugation

MP-RC5



STANDARD FEATURES

1. 16 gauge galvalume steel shell and baseplate

2. Corners mitered and welded watertight

3. Welds prime painted after fabrication

Ship To:

4. Additional reinforcing when specified

5. Water diverter

6. 6" minimum height on ridge side

7. 1-1/2" – 3# density insulation when specified





Order No.:

ADDED OPTIONS

Job No.: 1.

2.

Order Date:

3.

Due Date: MATCH ROOF PANEL









NO. REQ'D DIM. A DIM.B DIM.C H L TAG DESCRIPTION









Page ______ of _______ METALLIC PRODUCTS • Houston, Texas 77040

RC-5 / Rev. 2/01 (713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746

INSTALLATION INSTRUCTIONS for MP-RC5

ONE PIECE CONSTRUCTION

Must Be installed as Deck is Being Laid









A. B

1. As roof sheets are being installed, locate roof curb 4. Set curb in place and press flanges into mastic. Curb

opening and install support framing for roof curb and should be secured through roof deck to sub-framing using

equipment loads. Support at least two parallel curb walls. suitable fasteners compatible with roof system. A minimum

Avoid cantilever sections over 1' in length. of four fasteners per side spaced on 3" centers or less as

2. Trim and install panels on the left, right and below (eave roof system permits. Fasteners should withstand a mini-

side) of roof opening. Take care to keep area of curb I.D. mum pullout force of 150# each.

clear.

3. Apply tape caulk to roof deck around roof opening, 2"

from edge of opening.









C. D.

5. Apply sealant tape to leading edge of curb flange and 6. Check tightness of fasteners and curb installation, caulk

press ridge side roof panels into position over flange and perimeter edge of curb and flanges of roof panel to seal

corrugation closure ribs. Seam roof panels and secure moisture out.

through curb flange into support steel as in step 4. Seal 7. Apply a closed cell neoprene strip to top rail of roof curb

end of corrugation to pre-formed metal rib to prevent before setting a rooftop unit. Equipment should be fastened

capillary action of moisture. directly to curb wall using compatible fasteners.





RC-5/2

Customer:

Metallic Products

SLOPE MOUNT ROOF CURB

No Corrugation, For Over & Under Deck

Installation

MP-RC6

STANDARD FEATURES

1. 16 gauge galvalume steel shell and baseplate

2. Corners mitered and welded watertight

Ship To: 3. Welds prime painted after fabrication

4. Additional reinforcing when specified

5. Water diverting cricket

6. 6" minimum height on ridge side

7. 11/2" – 3# density insulation when specified

ADDED OPTIONS

Order No.: 1.

2.

Job No.: 3.

MATCH ROOF PANEL

Order Date:

(LOOSE RIBS)

Due Date:





FRONT FLANGE UNDER PANEL AND REAR FLANGES OVER PANEL

DIM. A 11⁄2"

9" CURB O.D. 6"





Insulation

6"









A A





Section A-A

Insulated

CURB O.D.

DIM. B









When

L









Specified

C









11⁄2"

6"









PLAN



Section A-A

H Uninsulated

L

12

ELEVATION

PITCH

NO. TAG

DIM. A DIM B H L

REQ’D DESCRIPTION









Page of METALLIC PRODUCTS • Houston, Texas 77040

RC-6 / Rev. 2/01 (713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746

END CAPS – RIB PROFILE









IB

OR R ROOF CURB

NOTCHED FOR PANEL RIBS

MAJ

L F

⁄ 4"

C O

2 3⁄4" 2 3









Note: Sealant Tape Must Be Applied

to All Four Sides

3"



NOTE:

Field Notch Skirt for

Lower Edge Ribs.

END CAP

(OVER PANEL)



SEALANT TAPE







Structure -

Not by M.P.

RIBBED ROOF PANEL SEALANT

PREPARED FOR CURB LOWER EDGE DETAIL TAPE







CURB DIM. O/D CURB ROOF PANEL SIDE DETAIL

1 ⁄2 "

1

OPENING DIM. 1 ⁄2 "

1

OPENING 1 ⁄2 "

1









4"

SEALANT TAPE



END CAP

(UNDER PANEL)

3"

Structure - 6" 3"

Not by M.P. 9" Structure -

3" 3" STD.

Not by M.P. SEALANT TAPE

6"

STD. SECTION THRU ROOF SLOPE SECTION @ SIDE UPPER EDGE DETAIL

DATE:

9/95

TITLE:

INSTALLATION

3306 Ella Blvd.

INSTRUCTIONS

PART:



Houston, TX 77018 ROOF CURB

(713) 688-6624 • 1-800-356-7746

E-mail: info@mpvent.com MPD-25

Metallic Products

SLOPE MOUNT ROOF CURB

Customer: Floating Curb w/Sub Framing

MP-RC7



STANDARD FEATURES

1. 16 gauge galvalume steel shell and baseplate

2. Corners mitered and welded watertight

3. Welds prime painted after fabrication

Ship To: 4. Internal angle reinforcing when specified

5. 6" minimum height on ridge side

6. 1-1/2" – 3# density insulation when specified





ADDED OPTIONS

Order No.: 1.

2.

Job No.: 3.

Order Date:

Due Date:









NO. REQ'D DIM. A DIM.B H L TAG DESCRIPTION









Page ______ of _______ METALLIC PRODUCTS • Houston, Texas 77040

RC-7 / Rev. 2/01 (713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746

Curb Sub Framing Detail

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









ROOF ACCESS HATCHES …









…used on metal roofing systems roofs conform to MP’s high standards and specifications which have been

developed, tested and proven over many years. They provide an excellent value for the user.



Custom Sizes Security

Virtually any size is available because each hatch is cus- Hatches are pad-lockable from either inside or outside.

tom manufactured. Construction

Roof Panel Configuration Durable 16 gauge galvalume steel construction. Optional

Hatch is built-in to roof curb to match roof slope and foil-backed fiberglass insulation available. All welds are

corrugations. made with bronze wire that will never rust. .080 Aluminum

Design is available upon request.

Hatch can be manufactured to open in any direction. They Finish

feature gas-charged opening devices and automatic hold- Long-lasting, heat-fused electrostatic powder factory ap-

open latch. plied to match any architectural color.





ROOF ACCESS!





Roof hatches manufactured by Metallic Products re- standards and specifications which have been developed,

quire no additional roof curb… because they are designed tested and proven since 1962.

with the curb built in! M.P.’s roof hatches are built to match Call (713) 856-9696 (toll free (800) 356-7746) or fax

any roof slope and corrugations match virtually any avail- (713) 856-9686 for ordering and/or additional information.

able roof panel. They can be made to match any architec- When you call, be sure to inquire about Metallic Product’s

tural color with our factory applied electrostatic powder many other metal building components; such as louvers,

heat-fused to 16 gauge galvalume steel. They are pad- ventilators, roof curbs, door canopies and specialty items.

lockable from either inside or out and feature gas-charged

opening devices as well as an automatic hold-open latch.

Best of all, they conform to Metallic Product’s high



7777 Hollister Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com

RH-01 / Rev. 2/01

DIMENSIONS AND TECHNICAL DATA



Each roof access hatch is custom manufactured to your specified opening and height dimensions and mounted in

the roof panel of your choice. They are furnished with or without insulation.





FRONT UNDER ROOF PANEL REAR OVER ROOF PANEL 1 1 ⁄2 " 1 1 ⁄2 "

DIM. A

3" 6" CURB O.D. 3"

Insulation

3"









4"





Double Handle

A A Lockset





Section A-A Section A-A

Uninsulated Insulated

CURB O.D.









Guide

DIM. C

DIM. B









When

L

Specified

C





Lift & Cushion Stay-Bar

Cylinder Brace

3"









6" Min.



PLAN



Piano Hinge

H (Cont.)

L LONG SECTION BRACE SECTION



12

ELEVATION

PITCH







ORDERING INFORMATION



Our customer service representatives are eager to assist you with placing your order, either by telephone, fax or

mail. We have ordering sheets available to simplify your ordering procedures and to ensure the accuracy of your

order. The information needed to complete your order include roof panel, opening length and width, panel width,

roof slope, height, width, hinge location, color, and whether to insulate or not.









METALLIC PRODUCTS • Houston, Texas 77040

(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746

Customer:

Metallic Products

SLOPE MOUNT ROOF ACCESS HATCH

Shop Located, Shingle Type, Factory Installed

Ribs

MP-RH1



STANDARD FEATURES

1. 16 gauge galvalume steel shell and baseplate

Ship To: 2. Corners mitered and welded watertight

3. Curbs prime painted after fabrication

4. Positive hold-open device

5. Water diverting cricket

6. 6" minimum height on ridge side

7. 11⁄2" – 3# density insulation when specified

8. Gas-charged opening device

Order No.:

ADDED OPTIONS

Job No.: 1.

Order Date: 2.

3.

Due Date: MATCH ROOF PANEL





FRONT UNDER ROOF PANEL REAR OVER ROOF PANEL 11⁄2" 11⁄2"

DIM. A

3" 6" CURB O.D. 3"

Insulation

3"









4"





Double Handle

A A Lockset





Section A-A Section A-A

Uninsulated Insulated

CURB O.D.









Guide

DIM. C

DIM. B









When

L









Specified

C









Lift & Cushion Stay-Bar

Cylinder Brace

3"









6" Min.









PLAN



Piano Hinge

H (Cont.)

L LONG SECTION BRACE SECTION



12

ELEVATION

PITCH

NO. HINGE TAG

DIM. A DIM B DIM C. H L

REQ’D LOCATION* DESCRIPTION









* Hinge may be located on any side. Please indicate RIDGE, EAVE, LEFT or RIGHT.





Page of METALLIC PRODUCTS • Houston, Texas 77040

RH-1 / Rev. 2/01

(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746

Customer:

Metallic Products

SLOPE MOUNT ROOF CURB

Flat Mounting Flange

MP-RH2



STANDARD FEATURES

1. 16 gauge galvalume steel shell and baseplate

2. Corners mitered and welded watertight

Ship To: 3. Curbs prime painted after fabrication

4. Positive hold-open device

5. Water diverting cricket

6. 6" minimum height on ridge side

7. 11/2" – 3# density insulation when specified

8. Gas-charged opening device specified



Order No.: ADDED OPTIONS

1.

Job No.: 2.

Order Date: 3.



Due Date: MATCH ROOF PANEL

(LOOSE RIBS)



FRONT FLANGE UNDER PANEL AND REAR FLANGES OVER PANEL

1

1/2" 11/2"



DIM. A

9" CURB O.D. 3"

Insulation





4"

3"









Double Handle

Lockset

A A



Section A-A Section A-A

Uninsulated Insulated

When Guide

CURB O.D.









Specified

DIM. B









L

C









Lift & Cushion

L Stay-Bar

Cylinder Brace

6" Min.

3"









PLAN

Piano Hinge

(Cont.)

H LONG SECTION BRACE SECTION

L

12

ELEVATION

PITCH

NO. HINGE TAG

DIM. A DIM B H L

REQ’D LOCATION* DESCRIPTION









* Hinge may be locatedon any side. PleaseindicateRIDGE, EAVE, LEFT or RIGHT.





Page of METALLIC PRODUCTS • Houston, Texas 77040

RH-1 / Rev. 2/01

(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746

Customer:

Metallic Products

SLOPE MOUNT ROOF ACCESS HATCH

Shingle Type, Factory Installed Ribs

MP-RH DD



STANDARD FEATURES

1. 16 gauge galvalume steel shell and baseplate

2. Corners mitered and welded watertight

3. Curbs prime painted after fabrication

Ship To:

4. Additional reinforcing when specified

5. Water diverter or cricket

6. 6" minimum height on ridge side

7. 11/2" – 3# density insulation when specified





Order No.:

ADDED OPTIONS

Job No.: 1.

2.

Order Date:

3.

Due Date: MATCH ROOF PANEL





11⁄2" 11⁄2"

DIM. A

3" 6" CURB O.D. 3"

Insulation

Section A-A Section A-A

Uninsulated Insulated

3"









4" When

Specified



A A





Double Handle

Lockset

CURB O.D.

DIM. C

DIM. B









CL









Lift & Cushion

Cylinder

3"









PLAN

6" Min.









H

L

12 Piano Hinge

ELEVATION (Cont.)

PITCH LONG SECTION





NO. HINGE TAG

DIM. A DIM B DIM C. H L

REQ’D LOCATION* DESCRIPTION









* Hinge may be located on any side. Please indicate RIDGE, EAVE, LEFT or RIGHT.





Page of METALLIC PRODUCTS • Houston, Texas 77040

RH-2 / Rev. 2/01

(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746

Customer:

Metallic Products

SLOPE MOUNT ROOF CURB

Flat Mounting Flange

MP-RH DD2



STANDARD FEATURES

1. 16 gauge galvalume steel shell and baseplate

2. Corners mitered and welded watertight

Ship To: 3. Curbs prime painted after fabrication

4. Positive hold-open device

5. Water diverting cricket

6. 6" minimum height on ridge side

7. 11/2" – 3# density insulation when specified

8. Gas-charged opening device specified



Order No.: ADDED OPTIONS

1.

Job No.: 2.

Order Date: 3.



Due Date: MATCH ROOF PANEL

(LOOSE RIBS)



1

FRONT UNDER PANEL AND REAR OVER PANEL 1/2" 11/2"







DIM. A Insulation

9" CURB O.D. 3"

3"









4"





A A Section A-A Section A-A

Uninsulated Insulated

When

Specified

CURB O.D.

DIM. B









Double Handle

L









Lockset

C









Lift & Cushion

Cylinder

3"









PLAN

6" Min.









H

L

12

ELEVATION Piano Hinge

LONG SECTION

PITCH (Cont.)



NO. HINGE TAG

DIM. A DIM B H L

REQ’D LOCATION* DESCRIPTION









* Hinge may be locatedon any side. PleaseindicateRIDGE, EAVE, LEFT or RIGHT.





Page of METALLIC PRODUCTS • Houston, Texas 77040

RH-1 / Rev. 2/01

(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746

Personnel Door Canopies









CANOPIES / ICE SHIELDS









Ice Shields

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









PERSONNEL DOOR CANOPIES









...attractive and efficient while eliminating the need and expense of drafting and manufacturing canopies as part

of the building package.





Construction Finish

Canopies are constructed of 26 gauge material around an 26 gauge galvanized steel or aluminum. Unit can be

18 gauge galvanized frame. Telescoping channels mount painted after assembly to match most metal building colors

between girts on the interior of the building. Channels will to properly accent building trim.

accommodate girt spacing of up to 7'6". l/2" threaded rod Standard Size

connects channels to canopy frame. All hardware neces- 4'0" projection from face of wall, available in 4'6" width for

sary for installation is included. single doors and 7'6" width for double doors.



Design Loading

Incorporates a flat soffit and an integral gutter drain. Canopy 4'6" wide canopy rated for 55#PSF gravity loading and 49#

drains against building to the outside of the door jambs. PSF wind uplift = 114 MPH if canopy is mounted no more

Canopy can be installed in conjunction with any panel type than 20' from the ground.

or panel location. Units can be flashed together for continu- (Optional 100#PSF available upon request).

ous applications. 7'6" wide canopy rated for 55#PSF gravity loading and 38# .

PSF wind uplift = 100 MPH if canopy is mounted no more

than 20' from the ground.

(Optional 100# PSF avaliable upon request)





An efficient and practical canopy for personnel soffit and an integral gutter drain. Finishes are avail-

doors ships as a complete unit, ready for installation. able in 26 gauge galvanized steel or aluminum and can

This canopy extends 4' from the wall and comes in two be painted before shipment to match any color to

standard widths: 4'6" for single doors and 7'6" for properly accent building trim. Unit comes with all

double doors. Integral framing is 18 gauge galvanized necessary hardware for mounting. Canopies mount

steel with telescoping channel for interior of building against any type of wall panel or masonary wall.

for girt spacing up to 7'6". Design incorporates a flat

7777 Hollister Rd Houston, Texas 77040 · Phone: 713.856.96964 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com

SI-01 / Rev. 2/01

GIRT SPACING (2'9" TO 6')

4'6" X 4' CANOPY 38" Center to Center









BACK TO BACK CLIP 403

7'6" X 4' CANOPY 86" Center to Center

CLIP 403

* 21/ 2"BOL T 402

TS O







COL 402 INSIDE

29" T 34"

O COL 401



CLIP 403

2 - #14 STS TYP



* GIRT OVER DOOR







DETAIL 1: INSTALL SUPPORT COLUMNS



CASE 1 CASE 2 BUILDING EXTERIOR WALL

9"

UPPER HANGER ROD

WALL PANEL Seal Before

DRILL 9/16 " HOLE, Tightening Nut

SEAL AFTER ERECTION HEX NUTS (2) HEX NUTS (2) HEX NUTS (2)

CANOPY BRACKET

UPPER HANGER ROD WASHER

BOLT OPTIONAL EXTERIOR

WASHER MOUNTING BRACKET

PIPE SLEEVES (2) Y ALL)

(MASONAR W

COL 402

PLAN VIEW



DETAIL 3

1 / 2"

1

Seal HEX NUTS (2)

DETAIL 2: INSTALL HANGER ROD 404



29"

HANGER ROD 404 BOLT 405 PLAN VIEW

NUT AND WASHER DETAIL 4: INSTALL LOWER BOLTS 405

NUT

6" 1

/ 2" BOLTS (2)

1

/ 2" BOL X 3"

T







ADJUSTING NUTS

CLOSURE AND SEALANT HEX NUTS (2) DOOR JAMB

BETWEEN CANOPY AND EXTENSION

CLIP 403

WALL (BY OTHERS DATE:

GIRT DETAIL 6 3/29/00

TITLE:



DETAIL 5: INSTALL CANOPY SUPPORT RODS FIELD ERECTION

PROCEDURE

7777 Hollister Road PART:



Houston, TX 77040

CANOPY

(713) 856-9696 • 1-800-356-7746

E-mail: info@mpvent.com CP-445

SI-01.1 / Rev. 3/00

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









Heavy Duty

PERSONNEL DOOR CANOPIES

“High Wind/Snow Loads”









Masonry mount with

optional decorative wall accents

(Inset — metal wall mount)









Up to 140 mph wind speeds and 100 lb snow loads *



Construction Finishes

• Economical and attractive overhead protection from • Galvalume steel

the elements • All standard metal building colors available in silicone

• Specifically designed for high wind load and heavy polyester, Kynar and powder coated finishes

snow load areas • Custom color matching

• 24 gauge flat soffit and integral gutter with rear • Single color or two tone (contrasting gutter/ fascia and

mounted drains soffit)

• 16 gauge galvanized internal frame

• 18 gauge telescoping support channels mount behind

wall panel between girts, mounting clips and fasteners Options

included • Masonry mount (anchors by others)

• ½" or ¾" galvanized pipe hangers with adjustable rod • Decorative wall accents

ends • Front mounted drains

Sizes

• Standard sizes for single door (4'-6" X 4'-0") and Design Specifications

double door (7'-6" X 4'-0"). Also available in 3' and 5' • Exposure category ‘B’; Importance factor, I = 1.0

projections • Topographic factor, K.zt = 1.0

• Can be mulled together for continuous run • Wind directionality, k.d. = 0.85

applications • Elevation of canopy no more than 30 ft above ground









* Wind speed and snow load requirements are specified when ordering and may effect installation requirements



7777 Hollister, Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com

SI-10 / Rev. 9/10

Metallic Products • Houston, Texas 77040

(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









CANOPY ERECTION INSTRUCTIONS - CASE 1

• Install vertical support columns to girt framing. Girt spacing should be between 2í9" and 6'0".

• Locate center of canopy and door. Adjust towards knob so that rod supports pierce wall panel

on high or low flat areas. Mark girts at desired length.

• Attach clip angles 403 to inside bottom of column 401 and to inside top of column 402 with 2 1/

2" bolts each. Insert column 402 inside column 401 (see Detail 1).

• Adjust columns to proper length to fit between girts. Secure 401 and 402 together with 6 #14

sts on each column (2 ea fl. & Web). (See detail #1). With columns assembled, drill 9/16"

diameter holes through 402 using holes in 401 flanges as guide.

• Locate columns in place back to back exactly 2'-10" apart at bottom (1'-5 1/8" each side of

length of canopy). Attach to girts with 2-#14 sts at each end of column.

• Install upper hanger rod 404 (see detail 4).

• Using upper holes as guide, locate and drill a 9/16" hole in a wall panel.

• Insert long end of rod through wall (from exterior) and through one flange of column. Put one

nut on rod and leave 1 1/2" thread. Place washer insert through inside flange. Place washer

and second nut. Snug tight.

• Install lower support bolts 405 (see detail 4).

• Using lower holes in column as guide, drill two 9/16" holes in wall panel (3'-0" c/c).

• Insert bolt with washer through inside flange, through pipe sleeve, outside flange, 2 hex nuts

and through wall panel. Tighten nut against column. Space last nut snug against inside of wall

panel for low conditions (see detail 3). Add nuts as follows: From exterior, thread one nut tight

against panel with sealant under nut; thread 2nd nut and locate at face of wall panel. This will

position canopy (bolts 3'-0" c/c).

• Install canopy to support rods (see detail 5). Thread nut onto upper hanger rod. For high

condition of wall panel (see detail 4), add sealant around bolt. Position canopy so that the two

lower bolts enter holes nearest center with back of canopy resting on bolts. Add washer to

upper rod, insert upper rods thru holes in top of supports beams. Add washer and hex nuts.

Add washer and nuts to bolts.

• Raise lower nuts on upper rod until canopy slopes 1⁄2" to 1" towards building. Tighten all nuts.

• Finish with closure and sealant by others as recommended.







ERECTION INSTRUCTIONS - CASE-2

• Locate desired bottom of canopy elevation on door jamb extensions. Measure up 3” and

drill 2 9/16” holes 3’-3” apart (one each jamb) for lower support bolts. (It may be

necessary to drill from exterior).

• Install vertical support columns for upper hanger rod same as case 1, except center on

holes in door jamb exterior and drill 9/16” holes 2-11⁄2” above holes in door jamb

exterior.

• Install upper hanger rod (same as case 1).

• Install lower support bolt (see detail 6).

• Install canopy to supports (same as case 1).









7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com

SI-01.2 / Rev. 2/01

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









ICE SHIELDS…









…engineered specifically for heavy snow and ice areas and provides protection from dangerous eave ice shear.





Construction Finish

Fabricated from 10 gauge structural plate. G-90 galvanized. Powdercoat painted to match most metal

All welded construction. building colors after fabrication.



Sizes Design Specifications

Available in single or double door sizes. Standard nominal 125 mph, BOCA 96, I=1.0.

projections of 2 ft., 3 ft., and 4 ft. 40 lb psf Roof Snow and Live Load.

57 lb psf Gravity Snow Load.









7777 Hollister Rd Houston, Texas 77040 · Phone: 713.856.96964 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com

SI-09 / Rev. 10/01

Ice Shield Kit Components:

• Ice Shield (10 Ga.)

Perimeter “J” Trim Ice Shield • Perimeter “J” Trim (26 Ga.)

A • Sheeting Angle (16 Ga.)

• Fasteners (#12 x 1 SDS)

• Sealant Caulk (Clear)

12 Quantities & lengths of components vary

4

1'-3"









based on size required.

C







B Fasteners Special Considerations:

Sheeting Angle

(not shown) Ice shield wall plates are pre-punched for

fastening to wall framing at predetermined

locations. If hole edge distance on standard ice

Walk Door shields requires modification to accommodate

5' Ice Shield - Single Door

special framing, please specify when ordering.

Ice shields are provided with stiffening angles

6'45⁄8"

welded to back side of wall plate. To

accommodate block wall installations, additional

7"-95⁄8" mounting holes replace stiffener angles (for flat

surface mounting). Please note this condition

when ordering.

Perimeter “J” Trim Ice Shield

A Fasteners for block wall mounting are not

provided by Metallic Products.



12

1'-7 5/8"









4



C







Fasteners

B Sheeting Angle

DATE:

(not shown) 8/24/01

TITLE:

ICE SHIELD

7777 Hollister RD PART:

COMPONENTS

7' Ice Shield - Double Door Walk Door

Houston, TX 77040

(713) 856-9696 • 1-800-356-7746 ICE SHIELD

E-mail: info@mpvent.com

SI-09.1 / Rev. 08/01

Wall Girt 5'-10"



Nominal Projection (-2")

Support Header

Support Jamb Support Jamb Wall Panel

8 x 4 Channel

(8 x 4 Channel) Support Header (8 x 4 Channel) Head Trim

(8 x 4 Channel)









2

A Ice Shield









1

Outline of Ice Shield









1'-2"

1'-2"

#12 SDS









2

C

Outline of Ice Shield Wall Girt

Stiffener Angles 8 x 21⁄2" Zee









5









7'-01⁄2" 3 5⁄8"

(shop welded to









7'-3 ⁄2"

Wall Girt

wall plate)









7'-31⁄2"

1

B

Sheeting Angle Walk Door Frame Sheeting Angle

(5 x 11⁄4") (5 x 11⁄4") Door Frame







3'-0" Section - A

Typical Ice Shield Wall Framing (Single Door) Single door w/o Subframe





Wall Girt 5'-10"



Nominal Projection (-2")

Support Header

Support Jamb Support Jamb Wall Panel

8x4 Channel

(8 x 4 Channel) Support Header (8 x 4 Channel) (8 x 4 Channel) Head Trim

A









2

Ice Shield









1

Outline of Ice Shield









1’-3 1⁄4"









1’-3 ⁄4"

2

#12 SDS









1

C

SubFrame

8x2 ⁄2" Channel

1









5

Stiffener Angles









7'-0 ⁄2" 3 ⁄8"

(shop welded to









7’-2 1⁄4"

Wall Girt Walk Door









5

B Subframe Header Wall Girt wall plate)









7’-2 ⁄4"

Sheeting Angle

Sheeting Angle









1

(5 x 1 ⁄4") Walk Door

1



(5 x 1 ⁄4")

1









1

Subframe Jambs

Door Frame





3'-41⁄4"

Typical Ice Shield Wall Framing (Single Door w/Subframe) Section - A

Single door w/Subframe

Wall Panel Support Header



Framing Note: Head Trim

Framing shown is based on industry standards for Ice Shield

typical walk door framing on metal buildings. Actual door

#12 x 1 SDS

and wall conditions may vary.

5'-10"

2 Wall Girt

Support Jamb Sill Trim

8 x 4 Channel







7'-31⁄2"

Stiffener Angle

#12 x 1 SDS 5 x 11⁄4" Shtg. Angle

7'-01⁄2"









Wall Panel (3-Places) DATE:

Field cut to length &

attach to wall girt

8/24/01

TITLE:



1

Ice Shield wall plate SINGLE DOOR

Jamb Trim

5'-6"

Section - B 7777 Hollister Rd

FRAMING INST.

PART:

Section - C Houston, TX 77040

Single door (713) 856-9696 • 1-800-356-7746 ICE SHIELD

E-mail: info@mpvent.com

SI-09.2 / Rev. 08/01

8'-1 ⁄8"

5



Wall Girt

Nominal Projection (-2")

Support Header

Wall Panel

8 x 4 Channel

Support Jamb Support Jamb

(8 x 4 Channel) (8 x 4 Channel) Head Trim

Support Header









2

A (8 x 4 Channel)

Ice Shield









1









1'-65⁄8"

Outline of









2

Ice Shield #12 SDS









1'-6 ⁄8"

5

C Wall Girt

Stiffener Angles 8 x 21⁄2" Zee









7'-01⁄2" 3 5⁄8"

(shop welded to









5









7'-3 1⁄2"

Wall Girt wall plate)

7'-3 1⁄2"









7'-31⁄2"

B

Sheeting Angle Walk Door Frame Sheeting Angle

(5 x 1 ⁄ ")

1

4 (5 x 11⁄4") Door Frame







6'-0" Section - A

Double door w/o Subframe

Typical Ice Shield Wall Framing (Double Door)



8'-1 ⁄8"

5



Wall Girt





Nominal Projection (-2")

Support Jamb Support Jamb Support Header

(8 x 4 Channel) Wall Panel

(8 x 4 Channel) Support Header 8 x 4 Channel

Support Header

(8 x 4 Channel) A (8 x 4 Channel) Head Trim









2

Outline of Ice Shield









1

Ice Shield









1'-77⁄8"

7'-77⁄8"









2

#12 SDS

C

SubFrame

Stiffener Angles 8 x 21⁄2" Channel









7'-0 ⁄2" 3 ⁄8"

5

(shop welded to

Wall Girt









5

7'-3 1⁄2"









Walk Door wall plate)









7'-21⁄4"









7'-2 1⁄4"

B Subframe Header Wall Girt

Sheeting Angle Walk Door Walk Door Sheeting Angle









1

(5 x 1 ⁄ ") (5 x 1 ⁄4")

1 1

4

Subframe Jamb Subframe Jamb Door Frame





6'41⁄4"

Section - A

Typical Ice Shield Wall Framing (Double Door w/Subframe) Double door w/Subframe

Framing Note: Wall Panel Support Header

Framing shown is based on Head Trim

industry standards for typical Ice Shield

walk door framing on metal 8'-15⁄8"

#12 x 1 SDS

buildings. Actual door and 2

wall conditions may vary. Support Jamb

8 x 4 Channel Wall Girt

Sill Trim

#12 x 1 SDS Stiffener Angle

Wall Panel



7'-31⁄2"

(5-Places) DATE:



5 x 11⁄4" Shtg. Angle

8/24/01

7'-01⁄2"









TITLE:



1

Ice Shield wall plate

Field cut to length &

attach to wall girt

DOUBLE DOOR

Jamb Trim 7'-95⁄8"

7777 Hollister Rd

FRAMING INST.

PART:

Section - C Section - B Houston, TX 77040

Double door (713) 856-9696 • 1-800-356-7746 ICE SHIELD

E-mail: info@mpvent.com

SI-09.3 / Rev. 08/01

Standard Building Trim









TRIM / FLASHING









Die Formed Flashing

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









STANDARD FEATURES:

n

Available in running lengths up to 21 ft.

n

Constructed of 26 gauge material

(see OPTIONS for additional gauges)

n

Available in Galvalume™, white or standard colors

(see OPTIONS for additional materials/finishes)

n

Boxed for shipment.





OPTIONS:

n

Additional metal thicknesses from 14 to 26 gauge

n

Additional materials/finishes:

– Galvanized

– Aluminum

– Stainless Steel

– Kynar 500™









STANDARD TRIM ITEMS:

n

Box Gutter n

Downspout Offset n

Sill Trim

n

Sculptured Gutter n

Sculptured Eave Trim n

Drip Trim

n

Box Rake Trim n High Side Eave Trim n

Cap Trim

n Sculptured Rake Trim n Simple Eave Trim n

Starter Trim "A" Panel

n Peak Boxes n Corner Trim "R" Panel n

Transition Trim

n Corner Boxes n Corner Trim "U" Panel n

Ridge Cap

n Downspout (straight) n Inside Corner “R” Panel n

Soffit/Valley Flashing

n

Downspout (with kickout) n Inside Corner “U” Panel n Valley Flashing

n Downspout Outlet n Jamb Trim n Die-Formed Flashing

n Downspout Elbow n

Head Trim









7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: mpv@mpvent.com · www.mpvent.com

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









TRIM PROFILES





BOX GUTTER - EG1 BOX RAKE TRIM - RT1 JAMB TRIM - JT17

PANEL

OPTIONAL 1" LEG 5 3/8" DEPTH

3/4"



2 1/2"

1/2"

1" 2 3/4"

3/4"

6 3/4"

1 1/2"



4 1/4" 4 1/2"







1 1/2"

1/2" 1 1/4"



5 1/4"

2"

3/4"







SCULPTURED GUTTER - EG2 SCULPTURED RAKE TRIM - RT2 HEAD TRIM - HT18



PANEL

OPTIONAL 1" LEG 5 3/8"

3/4" DEPTH





3 1/2" 2 3/4"

3 1/8"

3 1/8" 1 3/4"



6 9/16" 3/4"

6 9/16"

1/2"

4 1/2"

3 5/8" 1"

3 5/8"

COLOR

1 1/2"

1/2"



4 1/2"

2"









DRIP TRM - DT21 SILL TRIM - ST20 HEAD TRIM - HT19

1 5/16"









2 5/8" 2 3/4"

2"

1 3/8" 2 1/2" 1/2"

1"

1/2"

1/2"





OPTIONAL DT _ _ _ 1 3/4"









7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: mpv@mpvent.com · www.mpvent.com

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









TRIM PROFILES



SCULPTURED EAVE TRIM - ET3 CORNER TRIM "R" PANEL - CT6 STARTER TRIM "A" PANEL - ST26



6 5/8"





3 3/4" 1/2"



2" COLOR

1 1/4""



3 1/4" 1 1/8"



3 5/8"

3 1/2" 1"



1 1/2"

3/4"



1/2"

2"



HIGH SIDE EAVE TRIM - ET4 CORNER TRIM "U" PANEL - CT7 TRANSITION TRIM - TT27





7 3/8"



3 1/8" 3 1/4"

COLOR

3/4" 5 1/4"

1/2" PANEL

3 1/4" DEPTH

3 5/8"





1 1/2" 3/4" 5"



2" 1/2"" 3/4"



SIMPLE EAVE TRIM - ET5 INSIDE CORNER "R" PANEL - CT8

INSIDE CORNER "U" PANEL -CT9



4"

3" 3"



1 1/4"

3/4"



4"

3"

4" COLOR



COLOR

3/4"

3/4"



1/2"









7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: mpv@mpvent.com · www.mpvent.com

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









TRIM PROFILES

PEAK BOXES DOWNSPOUT OUTLET-DS14 RIDGE CAP -RC22









11 1/2"

4"







2' - 0"

3 5/8" 4 1/8"



o

CORNER BOXES DOWNSPOUT ELBOW 45 - DS15 RIDGE CAP - RC23









4" 6 1/2"



4"

1"



2 3/4"









DOWN SPOUT (STRAIGHT) DS12 DOWNSPOUT OFFSET - DS16 VALLEY FLASHING - SV25





4 1/4"

4"



1"

3 3/4"









6"



4"





SPECIFY





DOWN SPOUT (WITH KICKOUT) -DS13 SOFFIT/VALLEY FLASHING - SV24 CAP TRIM - CT26





8 1/8"





2 7/8" 2 7/8"

6" 1/2" 1/2"









7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: mpv@mpvent.com · www.mpvent.com

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









DIE FORMED FLASHING









“R” Panel “M” Panel









Standard Features: Applications

10 ft. coverage. Wall-to-Roof Transition Flashing

“R” Panel and “M” Panel profiles Ventilator Skirt Flashing

AZ-55 Galvalume or Polar White Roof and Wall Penetrations

(additional colors available upon request) High-Side Eave Flashing









WALL PANEL DIE FORM FLASHING

WALL PANEL

OVER ROOF PANEL

ROOF PANEL



DIE FORM FLASHING

OVER ROOF PANEL

DIE FORM FLASHING

OVER ROOF PANEL

WALL PANEL





EAVE STRUT

ROOF PANEL

ROOF PANEL

Wall-to-Roof Flashing High-Side Eave Flashing



“R” PANEL “M” PANEL

12 1⁄2"

4" 12 1⁄2"

4"



1 1⁄4"

3

⁄4 "

2" 2" 2" 2"





7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com

SI-05 / Rev. 10/01

METALLIC PRODUCTS

7777 Hollister Road • Houston, TX 77040

(713) 856-9696 Toll: 800-356-7746

E-mail: info@mpvent.com

Roof Jack









Specialty Items









4" & 12" Stamped Louvers





Pipe Flashing

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









ROOF JACKS

Type S



Straight side roof jack, mounted in flat base or customer

panel with or without cap.









TYPE S

DIM. DIM. CAP PANEL

NO. REQ’D T H Y or N TYPE PITCH COLOR







H









T









Type T



Tapered roof jack, mounted in flat base or customer panel

with or without cap.









TYPE T



NO. REQ’D DIM. DIM. DIM. CAP PANEL PITCH COLOR

T B H Y or N TYPE





H









T

B







Please confirm dimensions when ordering roof jacks. Roof pitch must be specified.





7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com

SI-04 / Rev. 2/01

NOTES:

1. SLATS MAY BE PLACED AT ANY SPACING OR DATE:

QUANTITY. 4/22/97

TITLE:

2. DIMENSION IS PER CUSTOMER REQUEST. 12"FLAT SKIRT

3. INSECT SCREEN IS OPTIONAL. 7777 Hollister Road

APPLICATION

STAMPED

PART:

4. COLOR IS OPTIONAL. Houston, TX 77040 RIDGE

LOUVER VENT

5. SLATS ARE FIXED. (713) 856-9696 • 1-800-356-7746

E-mail: info@mpvent.com 12-SL

CV-04 / Rev. 00/00

AL-05 / Rev. 2/01

NOTES:

1. SLATS MAY BE PLACED AT ANY SPACING OR DATE:

QUANTITY. 4/22/97

TITLE:

2. DIMENSION IS PER CUSTOMER REQUEST. 4" FLAT SKIRT

3. INSECT SCREEN IS OPTIONAL. 7777 Hollister Road

APPLICATION

STAMPED

PART:

4. COLOR IS OPTIONAL. Houston, TX 77040 RIDGE

LOUVER VENT

5. SLATS ARE FIXED. (713) 856-9696 • 1-800-356-7746

E-mail: info@mpvent.com 4-SL

CV-04 / Rev. 00/00

AL-06 / Rev. 2/01

L o u v e r s · V e n t i l a t o r s · T r i m · R o o f C u r b s · S p e c i a l t y I t e m s









PIPE FLASHING



FEATURES:

n

Provides tight seal to pipe penetrations

n

Performance is unaffected by ice, snow, hail stones, vibration or expansion

and contraction

n

Heavy duty aluminum alloy base is highly flexiable and corrosion resistant

and is compatible with virtually any roofing material

n Stepped cone design easily adapts to any roof pitch

n Available in 10 sizes to fit pipe diameters from 1/8" - 26"

n

EPDM available in black or grey/ Silicone available in red

n

Optional split-side construction for wrap around applications

EPDM or Silicone

EPDM SILICONE

ADVANCED OZONE

RESISTANCE tested to 70 hours @ 500 pphm 70 hours @ 500 pphm

HIGH TEMPERATURE

RESISTANCE

tested to.....intermediate +135ºC (+275ºF) +260ºC (+500ºF)

continuous +100ºC (+212ºF) +225ºC (+437ºF)

LOW TEMPERATURE

RESISTANCE tested to

-55ºC (-65ºF) -74ºC (-100ºF)

TENSILE STRENGTH

minimum 10 MPa (1450 psi) 5MPa (700 psi)

COMPRESSION SET

maximum. 25% 50%



INSTALLATION:









1. TRIM 2. SLIDE 3. FORM 4. SEAL 5. FASTEN

Trim opening to 20% Slide down over pipe. Press down , bending flashing Apply sealant between Use fasteners to finish sealing.

smaller than pipe diameter. to fit irregularities. Use large Master Flash and roofing.

slot screwdriver to press into

tight angles.



Description Pipe Size Base Dimension Vendor No. Net Wt.

Master Flash 1/8 ” – ¾” 2 ¼” MINI .2#

Master Flash ¼” – 2 ” 4 ½” #1 .2#

Master Flash 1 ¼” – 3 ” 6” #2 .3#

Master Flash ¼” – 4 ” 8” #3 .5#

Master Flash 3” – 6 ” 10 ” #4 .8#

Master Flash 4” – 7 ” 11 ” #5 1#

Master Flash 5” – 9 ” 12 ” #6 1.2#

Master Flash 6” – 11 ” 14 ” #7 1.6#

Master Flash 7” – 13 ” 17 ” #8 2.6#

Master Flash 10 ” – 18 ” 25 ” #9 3.86#

Master Flash 13 ” – 26 ” 34 ” Maxi 5.12#



7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com



Related docs
Other docs by dfgh4bnmu
Miller Cement E _Apr 25 07_.pub
Views: 4  |  Downloads: 0
How Lean Thinking Helps Hospitals g p p
Views: 0  |  Downloads: 0
Disperse Dyes
Views: 2  |  Downloads: 0
SURGICAL GOWNS NEW ZEALAND
Views: 0  |  Downloads: 0
A Coarse to Fine Corner-Finding Method
Views: 0  |  Downloads: 0
I L COULD CONVEY.
Views: 0  |  Downloads: 0
Electrical Engineering
Views: 0  |  Downloads: 0
0501.April Newsltr Final.qxd
Views: 6  |  Downloads: 0
By registering with docstoc.com you agree to our
privacy policy

You are almost ready to download!

You are almost ready to download!