Water Heater Refrigerator Freezer Dishwasher Disposal
GAS 1,400 VA 600 VA 1,030 VA 690 VA 1/4hp
4,500 VA 1,500 VA 700 VA 1,100 VA 828 VA 1/3hp
3,500 VA 1,600 VA 800 VA 1,200 VA 1,127 VA 1/2hp
6,000 VA 1,700 VA 900 VA 1,300 VA 1,587 VA 3/4hp
9,000 VA 1,800 VA 1,000 VA 1,400 VA 1,840 VA 1 hp
1,900 VA
2,000 VA
Central Vac Mini Refrigerator Jenn-aire -
1,440 VA 170 VA VA
1,600 VA 230 VA 8,000 VA
1,800 VA 340 VA 9,600 VA
1,100 VA
Central Air Strip Heat Units
Select Blower/fan Total Load Blue cells are fixed and the first value
5kW + 800VA Blower 5,800 VA cell is the default
7.5kW + 800VA Blower 8,300 VA
8kW + 800VA Blower 8,800 VA
9.6kW + 1.2kVA Blower 10,800 VA
10kW + 1.2kVA Blower 11,200 VA
12.5kW + 1.6kVA Blower 14,100 VA Yellow cells are for Your entries
15kW + 1.6kVA Blower 16,600 VA
17.5kW + 1.6kVA Blower 19,100 VA
20kW + 1.6kVA Blower 21,600 VA
+
+
+
+
+
Trash Compactor Microwave
780 VA 1,630 VA
1,000 VA
1,100 VA
1,200 VA
1,300 VA
1,400 VA
1,500 VA
Ironing Center
1,500 VA
1,800 VA
2,400 VA
s are fixed and the first value
ells are for Your entries
Residential Standard Calculation 9/25/1997 Job Name
by: John Sokolik Version 7.0
STEP 1 Article 220-11 and 16 (a) & (b) Company Name
sq. ft 2040 General Lighting load 6,120 VA Company Address
2 Small Appliance 3,000 VA City, Stste, Zip
2 Laundry circuit 3,000 VA Telephone and Fax
Gen.Lgt.,Sm App.& Laun. Load 12,120 VA 8/18/2009 13:20
3,000 VA @ 100%= 3,000 VA
9,120 VA @ 35% = 3,192 VA
VA @ 25% = VA
General Lighting Demand Load 6,192 VA
STEP 2 Article 220-14 & 15
3 ton 4,700 VA AHU 1 10kW 11,200 VA Total Heat Load 11,200 VA
A/C #2 VA AHU 2 Select VA Total CU Load 4,700 VA
A/C #3 VA AHU 3 Select VA Greater of Heat @ 100% vs.A/C @ 100% 11,200 VA
A/C #4 VA AHU 4 Select VA
A/C #5 VA AHU 5 Select VA
STEP 3 Article 220-17 Appliance Demand Load 21,055 VA
4,500 VA 1 Water Heater 4,500 VA
1,400 VA 1 Refrigerator 1,400 VA Dryer Demand Load 5,000 VA
700 VA Freezer VA
1,030 VA 1 Dishwasher 1,030 VA Range Demand Load 8,000 VA
690 VA 1 Disposal 690 VA
780 VA Trash Compactor VA Service Demand 51,447 VA
1,630 VA 1 Microwave 1,630 VA
1,440 VA Central Vac VA Demand Load 214 A
170 VA 1 Mini Refrigerator 170 VA
8,000 VA Jenn-aire VA Neutral Demand 80 A
- VA
1,500 VA Ironing Center VA Min.Service Req. 225 A
select Jacuzzi Tub VA
select Sprinkler Pump VA Min. Feeder size 3/0
1.5 hp Well Pump 2,300 VA Min. Neutral size 4
select VA Eq. Grding Cond. 6
select VA Copper
Pool Equip. Panel 12,265 VA 100% Demand
VA No Demand
VA No Demand Total Appliance Load 23,985 VA
4 or more demand @ 75% plus 100% demand loads 21,055 VA
STEP 4 Article 220-18
Electric Clothes Dryers 5,000 VA
STEP 5 Article 220-19
Electric Ranges 12,000 W Col A. demand 8,000 W
Number of appliances
Cooktop Col C demand
Check Box for Gas Range Cooktop Col C demand
Oven(s) Col C demand
Oven(s) Col C demand
Number of appliances 0 Dem. Factor 0%
Cooktop & Oven Demand Load W
jmp1jds@earthlink.net
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>><<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<
Pool Panel Feeder Calculation (See Note) A B N Continuous Non-continuous
Continuous Motors 1,840 . . . . . . 920 920 0 Motors Motors
Non-continuous 0 ...... 0 0 0 1 hp 240v select 240v
Spa heater 11 kVA ...... 0 0 select 240v select 240v
Pool heater 3.5 ton ...... 0 0 select 240v select 240v
Pool heater 5 ton 1 ...... 5063 5063 select 240v select 240v
Pool Light 300 0 ...... 300 0 300 select 240v select 240v
Blower select 0 240v 0 0 0
space 0 240v 0 0 0 0.0 Motor Neutral Load
space 0 240v 0 0 0
Copper Pool Feeder 52.354167 52 A 50 A 3A Max.Unbalanced Neutral Load
Phase Amperes Neut. load
Company Name
Company Name
Address
Company Address
City, State, Zip Code
City, Stste, Zip
Telephone & Fax
Telephone and Fax
Serial Number